• Title/Summary/Keyword: in-line 측정법

Search Result 393, Processing Time 0.028 seconds

Gas Temperature Measurement in Supersonic Flows by N2+ Emission Spectroscopy (질소 이온 발광 분광법을 이용한 초음속 유동의 기체 온도 측정)

  • Shin, Ji-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.245-250
    • /
    • 2010
  • The procedure for estimating the gas (rotational) temperature of an air discharge in supersonic flows is presented in detail. Since direct measurement of the temperature in a supersonic flow is difficult, a nonintrusive measurement was performed by optical emission spectroscopy based on the emission spectra of nitrogen molecular ions. A detailed explanation, including the equations for emission line intensity, is presented in order to understand the structure of the emission spectra of nitrogen molecular ions. Using the obtained representation for emission spectrum, a synthetic spectrum of the first negative system of $N_2^+$ is obtained, and it is compared with the experimentally measured spectrum. Within a relative error of approximately 6.8% for the overall band spectra, the synthetic and measured spectra agree well. In the case of a 25-mA DC air discharge in a supersonic (Mach 3) flow, the gas temperature profile shows an approximately linear variation and a peak temperature of approximately 350 K.

Observation and Analysis of Dislocation Spacing in the Subgrain boundary on IN 617 (IN 617의 아결정립계의 전위간격 분석법에 관한 고찰)

  • An, Seong-Uk;Lee, Jong-Min
    • Korean Journal of Materials Research
    • /
    • v.5 no.2
    • /
    • pp.184-190
    • /
    • 1995
  • IN 617 was crept under stresses of 107 and 180 MPa with monotonic deformation to strains of $\varepsilon$= 0.03 - 0.30 at 1073K. In order to determine the distances between the subgrain boundaries, the deformed specimens were examined at magnifications of one hundred thousand times by TEM. In cases . where TEM observations were not possible, subgrain angles($\theta$_{s}=sin^{-1}$(b/s))were measured by Kikuchi diffraction lines. The $\theta$_{k}$ converted from s values measured directly by TEM agreed very well with those measured from Kikuchi lines. Therefore, it was found that the $\theta$_{k}$ values could be used in obtaining s, especially in cases where it is impossible to measure s by TEM.

  • PDF

Fundamental Studies on the Development of On-line Monitoring of Trace Mercury in Drinking Water (음용수 중 수은 연속자동측정시스템의 개발에 관한 연구)

  • Chang, Soo-Hyun;Kim, Hyo-Jin;Kim, Sun-Tae;Kim, Young-Man
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.299-305
    • /
    • 1999
  • The electrolyte cathode atomic glow discharge (ELCAD) is a new plasma source for direct determination of trace heavy metals in drinking and waste water. ELCAD has been successfully developed for on-line monitoring of heavy metals, however, shows difficulty to measure mercury. In this study, ELCAD has been modified to apply the atomic absorption spectrometry (AAS) for the direct determination of trace elements of mercury in flowing water.The fundamental characteristics of this new types of plasma source have been investigated and found that the pH of the solution, discharge voltage, and current are most important factors.The absorbance of 1.0 ppm Hg standard solution increases as pH of the solution increases from pH 1.0 to 3.0.However, % RSD of the absorbance also increases as the pH of solution increasesdue to plasma unstability.The detection limits of the standard solution of pH 1.5 and pH 3.0 are about 40 ppb and 10 ppb level, respectively.

  • PDF

A Study on the Correction of Spectral Line Overlaps for the Determination of Rare Earth Elements by X-Ray Fluorescence Spectrometry (X-선 형광분광법에 의한 희토류원소 분석에서 스펙트럼선 겹침 방해의 보정에 관한 연구)

  • Young-Man Kim;Young-Sang Kim;Yoon-Chang Park;Chong-Wook Lee
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.538-547
    • /
    • 1986
  • The 8 rare earth elements were determined in the monazite concentrates by X-ray fluorescence spectrometry. The spectral line overlapping interferences from the other elements were investigated and the correction methods of interferences were studied using line overlap coefficients. The coefficients were calculated from the ratios of the intensities measured at the diffracted angle (2${\theta}$) of the analytical lines of other elements to the intensity of pure rare earth oxide. The coefficients were used to correct the line overlaps by a regression analysis. The linearities of calibration curves from the corrected intensities were remarkably improved, and their standard deviations were decreased. The analytical results agreed with that of the inductively coupled plasma(ICP) spectrometry within an allowable error range.

  • PDF

A Study on Measurement Techniques of Absorbing Ability for a RAM (RAM 흡수능 측정기법 연구)

  • Choi, Chang-Mook;Lim, Bong-Taeck;Ko, Kwang-Soob
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.527-530
    • /
    • 2010
  • In this paper, measurement techniques of absorbing ability of a RAM for RCS reduction were studied. As for the measurement techniques of absorbing ability, the free space method and transmission line method were established. And we made real RAM sample, measured absorbing according to each, and compared the results. After comparison, electromagnetic wave absorbing ability was measured to be somewhat superior in free space method and overall uniform pattern was observed. Therefore, by applying measurement techniques by stage and by frequency we could develop RAM in a more efficient way.

  • PDF

Characteristics of Insertion Loss of Transmission Line with Different Line Length Crossing a Rectangular Aperture in a Backplane (백 플레인의 개구를 통과하는 길이가 다른 전송 선로의 삽입 손실 특성)

  • Jung, Sung-Woo;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.237-243
    • /
    • 2008
  • This paper presents the backplane effects for two-wire transmission line with different line length crossing the rectangular aperture in an infinite ground backplane. The FDTD method is used to determine the characteristics of the backplane insertion loss and return loss of the transmission line in accordance with the transmission line spacing and additional wire lengths. The results show that the insertion gain is obtained for the narrow spacing of the transmission line and the insertion loss is appeared for the transmission line with the additional wire The measurements of return loss are performed to verify the theoretical analysis.

Method of Shape Error Measurement for the Optimal Blank Design of Shapes with 3D Contour Lines (목표윤곽선이 3 차원 곡선인 형상의 최적블랭크 설계를 위한 형상오차 측정법)

  • Shim, H.B.
    • Transactions of Materials Processing
    • /
    • v.24 no.1
    • /
    • pp.28-36
    • /
    • 2015
  • After a short review of the iterative optimal blank method, a new method of measuring the shape error for stamped parts with 3D contour lines, which is an essential component of the optimal blank design, is proposed. When the contour line of the target shape does not exist in a plane, but exists in 3D space, especially when the shape of the target contour line is very complicated as in the real automotive parts, then the measurement of the shape error is critical. In the current study, a method of shape error measurement based on the minimum distance is suggested as an evolution of the radius vector method. With the proposed method, the optimal blank shapes of real automotive parts were found and compared to the results of the radius vector method. From the current investigation the new method is found to resolve the issues with the radius vector method.

Accuracy of Intersection Counting Method in Measurement of Fiber Orientation Angle Distribution Using Image Processing (화상처리에 의한 섬유배향각 분포측정에 있어서 교차점합산법의 정밀도)

  • 이상동;박준식;이동기;한길영;김이곤
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.97-105
    • /
    • 1998
  • The fiber oriented condition inside fiber reinforced composite material is a basic factor of mechanical properties of composite materials. It is very important to meausure the fiber orientation angle for the determination of molding conditions, mechanical characteristics, and the design of composite materials. In the work, the fiber orientation distribution of simulation figure plotted by PC is measured using image processing in order to examine the accuracy of intersection counting method. The fiber orientation function measured by intersection counting method using image processing is compared with the calculated fiber orientation function. The results show that the measured value of fiber orientation function using intersection counting method is lower than the calculated value, because the number of intersection between the scanning line and the fiber with smaller fiber aspect ratio is counted less than with larger fiber aspect ratio.

  • PDF

Development of an On-line Measurement Method for Clean Biofuel Based on Near Infrared Spectroscopy and Chemometrics (근적외선 분광학과 화학계량학에 기반한 청정 바이오연료 실시간 품질 측정 기술 개발)

  • Cho, Hyeong-Su;Ryu, Jun-Hyung;Liu, J. Jay
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.215-224
    • /
    • 2011
  • It is an important issue to develop quality assessing system for biofuel for the purpose of accelerating the mass production of biofuel. It is particularly challenging to conduct testing method in the mass production of bioethanol while meeting quality specifications such as ASTM (American Society for Testing & Materials) D4806-10. In order to address this challenge, this paper proposes on-line spectroscopic quality assesment system based on Near Infrared spectrum and Partial Least Squares method in Chemometrics. As a result of testing a number of preprocessing methods and Partial Least Squares, it was found out that Savitzky-Golay method showed the best performance in terms of spectrum correction, noise reduction, and model maintenance. The proposed system allows us to assess multiple quality components continuously using spectroscopic facilities with the cheap cost. Since the value of R2 is more than 0.99, it is possible to replace the laboratory analysis.

Data Envelopment Analysis(DEA) using Length Rate-based Efficiency Measurement (길이 비율 효율성 측정법을 이용한 자료포락분석)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.3
    • /
    • pp.143-149
    • /
    • 2021
  • This paper proposes length rate measurement for relative efficiency that is a core of data envelopment analysis(DEA). It has been said that the linear programming(LP) is a unique method to get the relative efficiency. This method has drawback that applies fractional LP focusing on each DMU in turn. This paper draws bi-dimensional input-output relational graph and distinguishes between efficient and inefficient DMU. The relative efficiency of inefficient DUM is solve using length rate measurement. As a result of various experimental data, the LP shows mistake of application, but this method gets the correct relative efficiency at all times. Also, this method only gets the relative efficiency for only inefficient DMUs without efficient DUMs that already achieved 100% efficiency. This method solves the relative efficiency of inefficient DUM draws the line to efficient frontier and decides the reference set easily.