• Title/Summary/Keyword: in-construction monitoring

Search Result 1,716, Processing Time 0.03 seconds

Development of a Prototype Monitoring Module for Steel Bridge Repainting Robots (강교량 재도장 로봇의 모니터링 모듈 시제품 개발)

  • Seo, Myoung Kook;Lee, Ho Yeon;Park, Il Hwan;Chang, Byoung Ha
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.15-22
    • /
    • 2020
  • With the need for efficient maintenance technology to reduce maintenance costs for steel bridges, repainting robots are being developed to automate the work in narrow and poor bridge spaces. The repainting robot is equipped with a blasting module to remove paint layers and contaminants. This study developed a prototype monitoring module to be mounted on the repainting robot. The monitoring module analyzes the condition of the painting surface through a camera installed in the front, guides the direction of movement of the robot, and provides the operator with a video to check the working status after blasting through a camera installed in the back. Various image visibility enhancement technologies were applied to the monitoring module to overcome worksite challenges where incomplete lighting and dust occurs.

A case study on squeezing behavior of Pinglin tunnel in Taiwan (Taiwan의 Pinglin 터널에서의 Squeezing 거동 분석 사례 연구)

  • Yun, Il-Joong;Yoo, Ki-Cheong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1358-1365
    • /
    • 2010
  • A case study deals with Squeezing behavior under tunneling. Squeezing stands for large time-dependent convergence during tunnel excavation. Squeezing can occur in both rock and soil as long as the particular combination of induced stresses and material properties pushes some zone around the tunnel beyond the limiting shear stress at which creep starts. Under squeezing rock conditions, If the support installation is delayed the rock mass moves into the tunnel and a stress redistribution takes place around it. On the contrary, if deformation is restrained, squeezing will lead to long-term load build-up of rock support. This paper shows analysis case mutually with monitoring and numerical analysis result of squeezing behavior of Pinglin tunnel in Taiwan.

  • PDF

A Study of the Real-time Sensing by the Optical Current Sensor for GIS

  • Park, Won-Zoo;Kim, Yeong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.75-80
    • /
    • 2009
  • In this study, a Web server was constructed using LabVIEW's DataSocket, which makes possible acquisition, analysis, and saving in real time. The output value of the optical current sensor at the web server PC was measured and the output value was displayed using the Web browser of the client PC. DataSocket by LabVIEW makes the construction of a Web server easier than other languages and is compatible with other application programs. An optical current sensor was composed using a 1310 [nm] laser diode, and 9/125 [${\mu}m$] standard single mode optical fiber and was created to be a close type sensor. Data measurement using Web servers has the advantage of monitoring electric power systems at a great distance and can fuse IT technology and electric power systems. Also, this measurement uses inexpensive mounting and programming when compared to existing measurement equipment allowing the construction of a measurement system in any situation or surrounding.

Compaction Management of Fill Materials for Concrete Faced Rockfill Dam Using Standard Void Ratio (표준간극비를 이용한 콘크리트 표면차수벽형 석괴댐 축조재료의 다짐 관리)

  • Kim Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.4
    • /
    • pp.59-66
    • /
    • 2006
  • In this study, construction modulus, void ratio and settlement characteristics of 38 CFRD in domestic and foreign countries were investigated from monitoring data. The effect of field dry density and void ratio to dam body was analyzed. The standard void ratio of CFRD that can be easily used by dam designers and field engineers was proposed from the monitoring data. It was confirmed that we can get the degree of compaction needed for reasonable compaction of dam body by calculating the field dry density from inverse operation of the standard void ratio. It was thought that the void ratio of CFRD depends on shape coefficient and in case of a high shape coefficient, the void ratio was high with its void ratio 0.17 -0.38.

The Effects of Self-management on Supervisory Behaviors at a Construction Site (자기-관리 기법이 건설 현장 일선 관리자들의 안전 관리 행동에 미치는 영향)

  • Lee, Kyehoon;Lee, Jaehee;Moon, Kwangsu;Oah, Shezeen
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.151-159
    • /
    • 2012
  • This study implemented self-management technique to improve supervisory behaviors at a construction site. Self-management in the current study consisted of goal setting, self-monitoring and providing reward for two supervisory behaviors; (1) conducting safety observations of workers safety behavior and (2) providing safe related feedback. Two supervisors severed as participants. An AB within-group design was adopted. After baseline(A), self-management technique was implemented(B). Results suggested that self-management was effective in increasing the two supervisory behaviors. Moreover, the increased supervisory behaviors were associated with improvement in workers' safety performance.

Development of a displacement measurement system for architectural structures using artificial intelligence techniques (인공지능 기법을 활용한 건축 구조물 변위측정시스템 개발)

  • Kang, Ye-Jin;Kim, Dae-Geon;Woo, Jong-Yeol;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.135-136
    • /
    • 2022
  • As a recent technology, it is possible to partially grasp the occurrence of displacement of the entire building through artificial intelligence technology for big data through scanning. However, scanning and data processing take a lot of time, so there is a limit to constant monitoring, so constant monitoring technology of building behavior that combines wireless remote sensors and 3D shape scanning is required. Therefore, in this study, artificial intelligence program coding technology is linked. In addition, a technology capable of real-time wireless remote measurement of structure displacement will be developed through technology development in response to safety management that combines existing building technologies such as sensors. Through this, it is possible to establish an integrated management system for safety inspection and diagnosis.

  • PDF

Exposure of Outdoor Workers to Particulate Matter in Construction Sites (건설업 옥외작업장 근로자의 미세먼지 노출 실태 조사)

  • Kim, Seung Won;Lee, Ga Hyun;Phee, Young Gyu;Yang, Won-Ho;Ha, Wonchul;Park, Hyunghee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.46-58
    • /
    • 2017
  • Objectives: Particulate matter (PM) at construction sites mostly originates from either construction activities or the atmospheric environment. This study was conducted to evaluate the exposure level to PM and the contribution ratio of atmosphere sources at construction sites. Methods: We reviewed literature and governmental systems related to PM exposure in occupational settings and summarized them. In the field evaluation, five construction sites and one golf course were selected: two from Gyeonggi-do Province and four from North Gyeongsang-do Province. For each site, personal samples from outdoor construction workers and area samples from the outdoor area around the construction site office were collected according to construction work types. PM concentrations reported from nearby National Ambient Air Monitoring Stations were recorded. Respirable dust concentrations, respirable silica concentrations, and several metal concentrations including Cd, Cr, Pb, and As were monitored over four months. In the end we suggested how to manage particulate matter exposure at construction sites. Results: There was little literature reporting on exposure levels of construction workers to PM. Respirable dust concentrations measured in Gyeonggi-do Province were higher than those measured in North Gyeongsang-do Province. The geometric means of respirable dust concentrations in personal samples and area samples were $37.89{\mu}g/m^3$ and $92.86{\mu}g/m^3$, respectively. The respirable dust concentrations were higher than the PM concentrations reported from nearby National Ambient Air Monitoring Station. The geometric means of respirable silica concentrations of personal samples and area samples were $1.3{\mu}g/m^3$ and $1.1{\mu}g/m^3$, respectively. All metal concentrations were lower than 10% of individual Korean occupational exposure limits. Conclusions: Assuming that personal samples consisted of ambient PM and dust originating from work activities and area samples only collected ambient PM, we concluded that the dust exposure of outdoor construction workers originated 40.8% from the atmosphere and 59.2% from construction activities. PM exposure at construction sites should be controlled by employers, as in the case of outdoor heat stress. The Korean government needs to consider setting an occupational exposure limit for respirable dust.

A Study on Applicability of Wireless Impedance Sensor Nodes Technique for Tensile Force Monitoring of Structural Cables (구조용 케이블의 인장력 모니터링을 위한 무선 임피던스 센서노드 기술의 적용성에 관한 연구)

  • Park, Jae-Hyung;Hong, Dong-Soo;Kim, Jeong-Tae;Na, Won-Bae;Cho, Hyun-Man
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.21-31
    • /
    • 2010
  • In this study, a technique that uses wireless impedance sensor nodes is proposed to monitor tensile force of structural cable. To achieve this goal, the following approaches were implemented. First, a wireless impedance sensor node was designed for automated and cost-efficient prestress-loss monitoring. Second, an impedance-based algorithm was embedded in the wireless impedance sensor node for autonomous structural health monitoring of structural cables. Third, a tensile force monitoring technique that uses an interface plate for structural cables was proposed to overcome the limitations of the wireless impedance sensor node such as its narrow-band measurable frequency ranges. Finally, the applicability of the wireless impedance sensor node and the technique that uses the interface washer were evaluated in a lab-scaled prestressed concrete (PSC) girder model with internal and external tendons for which several prestress-loss scenarios were experimentally monitored with the wireless impedance sensor nodes.

Correlation Analysis of Vegetation Index and Drought Index (식생지수와 가뭄지수의 상관성 분석)

  • Kim, Kyung Tak;Park, Jung Sool
    • Journal of Wetlands Research
    • /
    • v.8 no.1
    • /
    • pp.49-58
    • /
    • 2006
  • Drought is an natural phenomenon which effects greatly on our society. It has various time scale and it is difficult to define the beginning and the end. So we can't aware it quickly and the damage of drought become severe. To cope with these problems, it needs to construct drought monitoring system. And it is required that the definition of drought which is objective and can be applied widely and proper drought index for drought monitoring. Meteorology and hydrology have developed drought index for drought monitoring. There are many attempt to interpret the drought using NDVI(Normalized Difference Vegetation Index) or LST(Land Surface Temperature) in remote sensing. In this study, drought index and precipitation is used to find drought severity of last ten years in South Korea. NDVI and VCI is applied to perceive the state of drought. Finally, the possibility of drought monitoring and evaluating drought depth is estimated by analyzing the correlation between vegetation Index and drought index.

  • PDF

The Study on the Monitoring and Diagnostic System for Distribution Transformer Using Wireless Communication (무선통신을 이용한 배전용 변압기 모니터링 및 진단 장치 개발에 관한 연구)

  • Moon, Jong-Fil;Kim, Jae-Chul;Choi, Joon-Ho;Kim, Oun-Seok;Yoon, Yong-Han;Min, Kyeoung-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.214-216
    • /
    • 2001
  • In this paper, we developed the on-line Diagnostic & Monitoring system of distribution transformers using wireless communication. The Diagnostic system consists of the top oil temperature sensing, ambient temperature sensing. load current sensing, acoustic emission peak-value sensing, acoustic emission pulse counter and wireless communication part. The Monitoring system consists of the communication setting, online monitoring and database construction part. The Diagnostic system send the date acquired from the some sensors of the distribution transformers to the host PC. The Monitoring program of the host PC store the data to database. And the Monitoring system estimates the loss of life from the DB. Thus it could be managed the career and the functional lifetime of the transformer more efficiently than existing methodologies.

  • PDF