• Title/Summary/Keyword: in-construction monitoring

Search Result 1,716, Processing Time 0.027 seconds

The Development of Measuring, Monitoring and Control System for Large Bridge Using Ubiquitous Computing Technology (유비쿼터스 컴퓨팅 기술을 활용한 대형교량의 계측, 모니터링, 통제시스템)

  • Lee Seung-Jae;Lim Jong-Kwon;Min Dae-Hong;Hwang Kyung-Hun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.182-187
    • /
    • 2004
  • Recently the application area of wireless LAN has been increased, rapidly. The application area was limited in indoor, but as the data throughput and performance of wireless LAN becomes better the application is to extend to the Internet connection and wireless(Ubiqitous) bridge in outdoor. In this paper, In this paper, the data throughput of wireless LAN in mobile environment is measured, and the usability of wireless LAN for develop bridge health monitoring system is confirmed.

  • PDF

Comparison of Time Series of Alluvial Groundwater Levels before and after Barrage Construction on the Lower Nakdong River (낙동강 하류 하천구조물 건설 전후의 충적층 지하수위 시계열 특성 비교)

  • Kim, Gyoo-Bum;Cha, Eun-Jee;Jeong, Hae-Geun;Shin, Kyung-Hee
    • The Journal of Engineering Geology
    • /
    • v.23 no.2
    • /
    • pp.105-115
    • /
    • 2013
  • Increasing the river cross-section by barrage construction causes rises in the average river water levels and discharge rates in the rainy season. The time series patterns for groundwater levels measured at 23 riverside monitoring wells along the lower Nakdong River are compared for two cases: before and after water-filling at the Changnyeong-Haman Barrage. Monthly average groundwater levels indicate a distinct increase in groundwater levels in the upstream riverside close to the barrage. River-water level management by barrage gate control in August, during the rainy season, resulted in a 0.1 m decrease in groundwater levels, while water-filling at the barrage in December caused a 1.3 m increase in groundwater levels. The results of hierarchical cluster analysis indicate that seven groundwater monitoring wells and river water levels were in the same group before barrage construction, but that this number increased to 14 after barrage construction. Principal component analysis revealed that the explanation power of two principal components corresponding to river fluctuation, PC1 and PC2, was approximately 82% before barrage construction but decreased to 45% after construction. This finding indicates that the effect of the river level component that contributes to change in groundwater level, decreases after barrage construction; consequently, other factors, including groundwater pumping, become more important. Continuous surveying and monitoring is essential for understanding change in the hydrological environment. Water policy that takes groundwater-surface water interaction into consideration should be established for riverside areas.

Material and geometric properties of hoop-type PZT interface for damage-sensitive impedance responses in prestressed tendon anchorage

  • Dang, Ngoc-Loi;Pham, Quang-Quang;Kim, Jeong-Tae
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.2
    • /
    • pp.129-155
    • /
    • 2022
  • In this study, parametric analyses on a hoop-type PZT (lead-zirconate-titanate) interface are performed to estimate the effects of the PZT interface's materials and geometries on sensitivities of impedance responses under strand breakage. The paper provides a guideline for installing the PZT interface suitable in tendon anchorages for damage-sensitive impedance signatures. Firstly, the concept of the PZT interface-based impedance monitoring technique in prestressed tendon anchorage is briefly described. A FE (finite element) analysis is conducted on a multi-strands anchorage equipped with a hoop-type PZT interface for analyzing materials and geometric effects. Various material properties, geometric sizes of the interface, and PZT sensor are simulated under two states of prestressing force for acquiring impedance responses. Changes in impedance signals are statistically quantified to analyze the effect of these factors on damage-sensitive impedance monitoring in the tendon anchorage. Finally, experimental analyses are performed to demonstrate the effects of materials and geometrical properties of the PZT interface on damage-sensitive impedance monitoring.

APPLICATION OF SATELLITE IMAGERY FOR DROUGHTS MONITORING IN LARGE AREA

  • Shin Sha-Chul;Jeong Soo;Kim Kyung-Tak;Kim Joo-Hun;Park Jung-Sool
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.398-401
    • /
    • 2005
  • Droughts have been an important factor in disaster management in Korea because she has been grouped into nations of lack of water. Satellite imagery can be applied to droughts monitoring because it can afford periodic data for large area for long time. This study aims to develop a method to analyze droughts in large area using satellite imagery. We estimated evapotranspiration in large area using NDVI data acquired from satellite imagery. For satellite imagery, we dealt with MODIS data operated by NASA. As the result of this study, we improved the usability of satellite imagery, especially in drought analysis.

  • PDF

Estimation of Extreme Heat Exposure at Outdoor Construction Sites through Wet Bulb Globe Temperature Modeling (습구흑구온도지수 모델링을 통한 옥외 건설 현장의 고열 노출수준 추정)

  • Saemi, Shin;Hea Min, Lee;Nosung, Ki;Jung Soo, Chae;Sang-Hoon, Byeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.402-413
    • /
    • 2022
  • Objectives: In this study, the scale of exceeding the extreme heat exposure standard at the construction site was estimated using the nationally approved statistical data and wet bulb globe temperature modeling method. By comparing and analyzing the modeling results with the existing work environment monitoring results, the risk of heat exposure at outdoor construction sites was considered. Methods: Using the coordinates of second level administrative districts and meteorological observatories as the key, the automated synoptic observing system data and building permit data for 2021 were matched. The wet-bulb temperature was obtained using Stull's formula, and the globe temperature was obtained using the TgKMA2006 model. WBGT was calculated using these. Excess rates were obtained compared to exposure limits for heavy work-continuous work and moderate work-25% rest. It was compared with the results of the work environment monitoring in 2020. Results: As a result, 1,827,536 cases were estimated for 11,052 workplaces in one year. This is much higher than the 5,116 cases of 3818 workplaces of the existing work environment monitoring results. It is confirmed that the exposure limit was exceeded in 10.6~24.0% of the entire period and 70.2~84.1% of the peak period of the heat wave. It is very high compared to 0.9% of the existing work environment monitoring result. Conclusions: It is necessary to improve the system of monitoring and statistics related to extreme heat. Additional considerations are needed regarding WBGT estimation methods, meteorological data, and evaluation time. Various follow-up risk assessment studies for other industries and time series need to be continued.

Construction and Monitoring of Test bed in Urban Sediment Disaster Prevention Technology (도심지 토사재해 방어기술 테스트베드 구축 및 모니터링 연구)

  • Lee, Jung-min;Kim, Hyo-Jin;Lee, Yoon-Sang;Jin, Kyu-Nam
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.161-169
    • /
    • 2017
  • In this study, sediment transfer and precipitation analysis of the test bed watershed was conducted through the model for the application and practical use of the urban sediment disaster prevention technology, and used this as an aid to design to secure reliability. In addition, conducted the test bed monitoring with the defense technology, analyzed the effect, and established the maintenance plan. Analyzed the change of soil deposition volume through arbitrary slope adjustment for the currently installed stormwater conduit of the test bed watershed. As a result, it is important to reduce the total sedimentation amount in the adjustment of the slope of the entire pipeline, but it is important that the sedimentation depth of each sediment does not rise to such a degree as to threaten the performance of the pipeline. Considering these matters, it is necessary to design the pipeline to prevent the clogging of the soil from the viewpoint of the reliability of the entire pipeline. The sediment disaster defense technology test bed is divided into a new city and an old city, and old city test bed is under construction. The result obtained through the monitoring of the test bed in the new city, sediment disasters such as debris can delay the time to reach the downtown area, and it is possible to secure the golden time, such as evacuation and rescue through the warning system. Also, the maintenance of the test bed application was suggested. Continuous and systematic monitoring is required for securing the reliability of element technology and successful commercialization.

Monitoring of Cleanliness Level in Hydraulic Systems: Obtaining Reliable On-Line data

  • Hong, Jeong-Hee;Day, Mike
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.28-38
    • /
    • 2012
  • Monitoring of system cleanliness levels and counting of particulate contaminant are fundamental to achieving hydraulic system reliability as any departure from the specified cleanliness level is often a precursor to future failures. On-line monitoring of cleanliness levels has the advantage of giving data both very quickly and accurately as environmental influences are eliminated. In this way, corrective actions can be promptly implemented. Most on-line instruments are sensitive to system conditions to a greater or lesser extent, but Automatic Particle Counters (APCs) working on light extinction principles are especially sensitive to the presence of optical interfaces caused by such conditions as fluid mixtures, emulsions, free water and air bubbles. These conditions give erroneous data and can result in drawing incorrect conclusions, wasting maintenance time and ultimately, reduced user confidence in cleanliness monitoring. This paper describes such conditions and shows how the correct selection of the analysis technique can result in reliable cleanliness level data.

An Experimental Study on the Monitoring of Corrosion of Rebar Embedded in Reinforced Concrete (철근콘크리트에 매립된 철근의 부식 모니터링에 관한 실험적 연구)

  • Park, Jang-Hyun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.262-263
    • /
    • 2019
  • In this study, a sensor for detecting corrosion of rebar embedded in reinforced concrete structures was fabricated and its performance was verified. In order to monitor the open circuit potential(OCP) of the rebar embedded in reinforced concrete, a concrete embedded solid electrode was constructed as a sensor using MnO2. The OCP of the rebar could be observed using a sensor and a data logger. The decrease of the OCP to -510mV (vs.MnO2) or less was judged to be corrosion of the rebar. Since it is a solid-mediated sensor, it is more stable and durable than an electrode using an aqueous solution, and it is considered that the corrosion state of the rebar can be monitored for a long period of time.

  • PDF

A MODEL FOR SELECTION, AWARDING, AND MONITORING OF PPP PROJECTS IN DEVELOPING COUNTRIES; HEALTH CARE FACILITIES IN COLOMBIA

  • Henry Arboleda-Mantilla;Carlos A. Arboleda
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.344-351
    • /
    • 2013
  • Private participation on public infrastructures projects is being promoted by governments of several developing countries, among them Colombia. As a result, several advantages such as service delivery efficiency, technology application and faster execution of the projects have been recognized. Hence, the Colombian Government is looking for schemes that allow the private investment in projects like hospitals, schools, prisons and public edification. In this paper, experiences in PPP from other countries were analyzed and adjusted to the Colombian environment. As a result, a model adapted to Colombia is presented, based on a well-developed case from Spain. The awarding process is defined by economic criteria, previous compliance of minimum technical exigencies. Once the infrastructure is operating, contractual periodical payments will be done, based on the performance of the facility.

  • PDF

A review of rotorcraft Unmanned Aerial Vehicle (UAV) developments and applications in civil engineering

  • Liu, Peter;Chen, Albert Y.;Huang, Yin-Nan;Han, Jen-Yu;Lai, Jihn-Sung;Kang, Shih-Chung;Wu, Tzong-Hann;Wen, Ming-Chang;Tsai, Meng-Han
    • Smart Structures and Systems
    • /
    • v.13 no.6
    • /
    • pp.1065-1094
    • /
    • 2014
  • Civil engineers always face the challenge of uncertainty in planning, building, and maintaining infrastructure. These works rely heavily on a variety of surveying and monitoring techniques. Unmanned aerial vehicles (UAVs) are an effective approach to obtain information from an additional view, and potentially bring significant benefits to civil engineering. This paper gives an overview of the state of UAV developments and their possible applications in civil engineering. The paper begins with an introduction to UAV hardware, software, and control methodologies. It also reviews the latest developments in technologies related to UAVs, such as control theories, navigation methods, and image processing. Finally, the paper concludes with a summary of the potential applications of UAV to seismic risk assessment, transportation, disaster response, construction management, surveying and mapping, and flood monitoring and assessment.