• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.031 seconds

A Study on the Development of the Photo-electric Single Station Smoke Alarm of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력의 광전식 단독경보형감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • This is a case report of a photo-electric single station alarm for residential fire prevention. The detector was developed for the certification in Japanese market which is more than 100 times bigger than Korean market. A comparison and review for test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively is also conducted. The detector alarms with a buzzer and an indicating LED. Operating period and time in alarm, low battery and fire situation is stated. The electronics circuit part to reduce its current and the detector's characteristics are described. It is explained that the measured current and experimental result of the battery discharge can meet the 10 years operation.

SSHG(Sag/swell and Harmonics Generator) Development for Actual Test of CPD(Custom Power Device) (전력품질 향상기기의 실증시험을 위한 SSHG 개발)

  • Kwon G. H.;Chung Y. H.;Kim H. J.;Park T. B.;Jeon Y. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.205-207
    • /
    • 2004
  • This paper proposes a new SSHG(Sag/swell and Harmonic Generator) injecting voltage by using series inverter. The proposed SSHG composes series inverter, DC capacitor as energy storage, rectifier and voltage clamp circuit. This SSHG is designed to generate typical power disturbances, such as voltage sag/swell, over/under voltage and voltage flicker. Also it is designed to generate unexpected voltage phase jumping waveform by controlling the series inverter. In this paper, three kinds of control methods for the proposed 2MVA SSHG are given. Typical voltage sag and swell waveforms are implemented by adopting simple control method. Also the voltage flicker is generated by changing the amplitude of the injected voltage in random. Owing to the limited bandwith of the proposed SSHG, high frequency transient waveforms can be obtained by using the open loop control. The simulation and experimental results are given to verify the operation of the proposed SSHG, Finally, conclusions are given.

  • PDF

OCI and ROCSAT-1 Development, Operations, and Applications

  • Chen, Paul;Lee, L.S.;Lin, Shin-Fa
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.4
    • /
    • pp.367-375
    • /
    • 1999
  • This paper describes the development, operations, and applications of ROCSAT-l and its Ocean Color Imager (OCI) remote-sensing payload. It is the first satellite program of NSPO. The satellite was successfully launched by Lockheed Martin's Athena on January 26, 1999 from Cape Canaveral, Florida. ROCSAT-l is a Low Earth Orbit (LEO) experimental satellite. Its circular orbit has an altitude of 600km and an inclination angle of 35 degrees. The satellite is designed to carry out scientific research missions, including ocean color imaging, experiments on ionospheric plasma and electrodynamics, and experiments using Ka-band (20∼30GHz) communication payloads. The OCI payload is utilized to observe the ocean color in 7 bands (including one redundant band) of Visible and Near-Infrared (434nm∼889nm) range with the resolution of 800m at nadir and the swath of 702km. It employs high performance telecentric optics, push-broom scanning method using Charge Coupled Devices (CCD) and large-scale integrated circuit chips. The water leaving radiance is estimated from the total inputs to the OCI, including the atmospheric scattering. The post-process estimates the water leaving radiance and generates different end products. The OCI has taken images since February 1999 after completing the early orbit checkout. Analyses have been performed to evaluate the performances of the instrument in orbit and to compare them with the pre-launch test results. This paper also briefly describes the ROCSAT-l mission operations. The spacecraft operating modes and ROCSAT Ground Segment operations are delineated, and the overall initial operations of ROCSAT-l are summarized.

Effect of Fe(NO3)2 Concentration on Electrochemical Behavior of SCM430 in Zinc Phosphate Conversion Coating Solution (아연계 인산염 피막용액에서 Fe(NO3)2 농도가 SCM430 합금의 전기화학적 거동에 미치는 영향)

  • Kwon, Duyoung;Song, Pung-Keun;Moon, Sungmo
    • Journal of Surface Science and Engineering
    • /
    • v.52 no.4
    • /
    • pp.233-238
    • /
    • 2019
  • The formation behavior of zinc phosphate conversion coating (ZPCC) on SCM430 alloy was investigated in 25 vol.% of 1M ZnO + 170 ml/L solution containing various $Fe(NO_3)_2$ concentrations, using open-circuit potential(OCP), electrochemical impedance spectroscopy(EIS), cyclic polarization(CP) curve and tape peel test. OCP of SCM430 alloy and corrosion current density increased with increasing $Fe(NO_3)_3$ concentration. Resistance of films formed on SCM430 alloy by chemical conversion treatment decreased with increasing $Fe(NO_3)_3$ concentration. Color and adhesion of chemical conversion coatings became darker and worse, respectively, with increasing $Fe(NO_3)_3$ concentration. It is concluded that addition of $Fe(NO_3)_3$ into a zinc phosphating bath leads to faster reaction to form porous surface coatings with poor adhesion and corrosion resistance.

FPGA-Based Low-Power and Low-Cost Portable Beamformer Design (FPGA 기반 저전력 및 저비용 휴대용 빔포머 설계)

  • Jeong, GabJoong;Park, CheolYoung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • In this paper, we develop a beamforming front end platform with pipeline circuit configuration method that can apply various clinical diagnostic applications of ultrasound image technology. Hardware design targets compression applications as well as scalable applications where power, integration levels and replication possibilities are important. Firmware design was implemented to achieve optimal FPGA parallel processing level by constructing new IP and system-oriented design environment to accelerate design productivity with maximum productivity improvement using Vivado HLS tool, which is a next generation high level synthesis tool. Former supports the high-speed management function of scan data that can create an image area arbitrarily and can be appropriately corrected and supplemented when reconfiguring or changing system specifications in the future.

Development of Aging Diagnosis Device Through Real-time Battery Internal Resistance Measurement

  • Kim, Sang-Bum;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.129-135
    • /
    • 2022
  • Currently, the rapid growth of electric vehicles and the collection and disposal of waste batteries are becoming a social problem. The purpose of this paper is to propose a fast and efficient battery screening method through a safe inspection and storage method according to the collection and storage of waste batteries of electric vehicles. In addition, as the resistance inside the waste battery increases, an instantaneous voltage drop occurs, and there is a risk of overcharging and overdischarging compared to the initial state of the battery. Accordingly, there are great difficulties in operation, so the final goal of this study is to develop a device for diagnosing aging through real-time battery internal resistance measurement. Final result As a result of simulation of the internal resistance measurement test circuit through external impedance (AC), the actual simulation value was 0.05Ω, RS = Vrms / Irms => Vrms = 8.0036mV, Irms = 162.83Ma. Substitute the suggested method. The result was calculated as Rs = 0.0495Ω. It is possible to measure up to 64 impedances inside the aging diagnostic equipment that enables real-time monitoring of the developed battery cells, and the range can be changed according to the application method.

Drug distribution management system based on IoT

  • Liu, Zeliang;Zhang, Chunmei;Peng, Hui;Xu, Qin;Gao, Yubao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.2
    • /
    • pp.424-444
    • /
    • 2022
  • In hospitals and pharmacies, the distribution of medicines is an important part. Any mistakes, misses, fake medicines and expired medicines can cause medical accidents. With the widespread application of the Internet of Things technology (IoT), traditional drug distribution methods need to be upgraded. This article proposes a drug distribution management scheme based on the Internet of Things technology. In the production of drugs, a flexible RFID tag was printed on the packaging box, which stored a series of information such as drug name, dosage, raw materials, efficacy, production date, expiration date, and manufacturer. The use of a drug distribution management system combined with RFID readers can identify drug information and effectively prevent the occurrence of erroneous, missed, counterfeit, and expired drugs. It can also improve management efficiency, reduce management costs, and control management risks. Through the circuit design and software system development, the test results show that this solution is effective and feasible, the proposed method can achieve the expected results.

A Study on Developing of Soldering Flux (납땜 플럭스 개발에 관한 연구)

  • 이통영
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2000
  • Flux, essentially used in soldering process of PCB (Printed Circuit Board) in electronics industry, contains IPA (Isopropyl alcohol) and methanol, which are highly inflammable and explosive. Hazard Chemical Controlling Law classified methanol as toxic material and Environmental Law classified methanol as VOC (Volatile Organic Compound). So there have been pressing needs of developing substitutes for the existing Flux. New solvent which is non-flammable and main component is DCP having same specific character of the existing Flux. It's been combirated with proper composition ratio adding stabilizer. As a result, it relieved working Environment Allowance thickness 200 ppm to 470 ppm, chance of not been soldered 0.083% to 0%, spread 85% to 87%, power saving resistance 1.0$\times$$10^{12}$$\Omega$ to 6.9$\times$$10^{12}$$\Omega$, which means a lot better than the existing Flux. Therefore, Flux confirmed the chance of improving productivity, safety, environment safety and quality. Also, Flux got a satisfied result after product quality test and product reliability test.

  • PDF

Development of Implantable Blood Pressure Sensor Using Quartz Wafer Direct Bonding and Ultrafast Laser Cutting (Quatrz 웨이퍼의 직접접합과 극초단 레이저 가공을 이용한 체내 이식형 혈압센서 개발)

  • Kim, Sung-Il;Kim, Eung-Bo;So, Sang-kyun;Choi, Jiyeon;Joung, Yeun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.168-177
    • /
    • 2016
  • In this paper we present an implantable pressure sensor to measure real-time blood pressure by monitoring mechanical movement of artery. Sensor is composed of inductors (L) and capacitors (C) which are formed by microfabrication and direct bonding on two biocompatible substrates (quartz). When electrical potential is applied to the sensor, the inductors and capacitors generates a LC resonance circuit and produce characteristic resonant frequencies. Real-time variation of the resonant frequency is monitored by an external measurement system using inductive coupling. Structural and electrical simulation was performed by Computer Aided Engineering (CAE) programs, ANSYS and HFSS, to optimize geometry of sensor. Ultrafast laser (femto-second) cutting and MEMS process were executed as sensor fabrication methods with consideration of brittleness of the substrate and small radial artery size. After whole fabrication processes, we got sensors of $3mm{\times}15mm{\times}0.5mm$. Resonant frequency of the sensor was around 90 MHz at atmosphere (760 mmHg), and the sensor has good linearity without any hysteresis. Longterm (5 years) stability of the sensor was verified by thermal acceleration testing with Arrhenius model. Moreover, in-vitro cytotoxicity test was done to show biocompatiblity of the sensor and validation of real-time blood pressure measurement was verified with animal test by implant of the sensor. By integration with development of external interrogation system, the proposed sensor system will be a promising method to measure real-time blood pressure.

Design of an eFuse OTP Memory of 8bits Based on a Generic Process ($0.18{\mu}m$ Generic 공정 기반의 8비트 eFuse OTP Memory 설계)

  • Jang, Ji-Hye;Kim, Kwang-Il;Jeon, Hwang-Gon;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.687-691
    • /
    • 2011
  • In this paper, we design an 8-bit eSuse OTP (one-time programmable) memory in consideration of EM (electro-migration) and eFuse resistance variation based on a $0.18{\mu}m$ generic process, which is used for an analog trimming application. First, we use an external program voltage to increase the program power applied an eFuse. Secondly, we apply a scheme of precharging BL to VSS prior to RWL (read word line) activation and optimize read NMOS transistors to reduce the read current flowing through a non-programmed cell. Thirdly, we design a sensing margin test circuit with a variable pull-up load out of consideration for the eFuse resistance variation of a programmed eFuse. Finally, we increase program yield of eFuse OTP memory by splitting the length of an eFuse link.

  • PDF