Evaluation Technique for Ratio Error and Phase Displacement of Current Transformer Comparator (전류변성기 비교기의 비오차 및 위상오차 평가기술)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.437-443
    • /
    • 2008
  • We have developed an evaluation technique for both ratio error and phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique to equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors (or phase displacements) in the CT comparator. Thus we can evaluate ratio errors and phase displacement of CT comparator by comparing the calculated and measured ratio errors (or phase displacements). The method was applied to CT comparator under test with the ratio errors and phase displacement ranges of $0{\sim}{\pm}10%$ and $0{\sim}{\pm}7.5$ crad, respectively. Finally we have compared the ratio error and phase displacement of the CT comparator obtained in this method with specifications of two companies.

A Novel Hybrid Fault Location Sensor Employable to the Power Transmission Systems (가공 송전선의 사고 및 낙뢰 검출을 위한 새로운 하이브리드 센서)

  • Chang, Yong-Moo;Kang, Moo-Sung;Hwang, Ryul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.583-584
    • /
    • 2005
  • In this work, a novel hybrid FL sensor consisting of two Rogowski coils has been designed for the installation on the ground wire of the transmission tower. The operation range of these coils is as follows: 30kA for the fault current comingfrom the ground fault or short-circuit and for the lightning current up to 150kA over 500kHz. Thus, two important functions could be provided: one is to detect the fault current and the other one is to find the fault location between towers or the location of induced lightning stroke. The on-site investigation at 800kV test yard has been under progress for its on-site application.

  • PDF

Analysis of Impulse Response of Power Transformer using Electric Equivalent Circuit (등가회로를 이용한 전력용 변압기의 과도응답 특성 해석)

  • Chang, Kyung-Woon;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.97-99
    • /
    • 1998
  • This paper presents a numerical study of the behavior of the transformer winding, when stressed by the standard impulse voltage. The mathematical model of the transformer takes several points into the account. Capacitance of not adjacent winding as well as adjacent winding, eddy current loss caused by self and mutual inductance given as the functions of frequency. Not like the previous approach where calculation of capacitance is performed, in average sense. In this paper, capacitance of both adjacent and not adjacent winding is calculated using the numerical approach(B.E.M.), so they can get the more accurate value of capacitance. Because of frequency dependency of inductance, numerical-laplace-transform technique is required. Finally, to validate this approach, a simple test winding is simulated.

  • PDF

A Study on the Reliability of Plastic BGA Package (플라스틱 BGA 패키지의 신뢰성에 관한 연구)

  • Kim, Gyeong Seop;Sin, Yeong Ui
    • Journal of Welding and Joining
    • /
    • v.18 no.2
    • /
    • pp.222-222
    • /
    • 2000
  • PBGA(Plastic Ball Grid Array) is composed of some materials such as PCB(Printed Circuit Board), epoxy molding compound, die attach and so on. Reliability of PBGA package is weak compared with plastic packages. The weak points of reliability are the lower resistance to popcorn cracking, which is induced by moisture absorption in PCB, and the pressure cooker test corrosion, which is the basic problem due to the material characteristics of PCB. Introducing the PCB baking and the plasma treatment cleared the popcorn cracking phenomenon. The PCB baking and plasma treatment reduced the epoxy void by eliminating the source of moisture vaporization during the epoxy curing and enhanced the adhesion between PCB and epoxy. Also, plasma treatment enhanced the wettability of epoxy on PCB. The problem of corrosion is cleared using multi-functional epoxy. This type of EMC(Epoxy Molding Compound) is recommended in package using PCB as a substrate. (Received November 19, 1999)

A Study on the Reliability of Plastic BGA Package (플라스틱 BGA 패키지의 신뢰성에 관한 연구)

  • 김경섭;신영의
    • Journal of Welding and Joining
    • /
    • v.18 no.2
    • /
    • pp.95-99
    • /
    • 2000
  • PBGA(Plastic Ball Grid Array) is composed of some materials such as PCB(Printed Circuit Board), epoxy molding compound, die attach and so on. Reliability of PBGA package is weak compared with plastic packages. The weak points of reliability are the lower resistance to popcorn cracking, which is induced by moisture absorption in PCB, and the pressure cooker test corrosion, which is the basic problem due to the material characteristics of PCB. Introducing the PCB banking and the plasma treatment cleared the popcorn cracking phenomenon. The PCB banking and plasma treatment reduced the epoxy void by eliminating the source of moisture vaporization during the epoxy curing and enhanced the adhesion between PCB and epoxy. Also, plasma treatment enhanced the wettability of epoxy on PCB. The problem of corrosion is cleared using multi-functional epoxy. This type of EMC(Epoxy Molding Compound) is recommended in package using PCB as a substrate.

  • PDF

Performance test for transmitted noise reduction of smart panel using piezoelectric shunt damping (압전 션트를 이용한 패널의 투과소음 저감 성능에 관한 연구)

  • 최진영;김재환;이중근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1120-1125
    • /
    • 2001
  • A new concept of piezoelectric smart panels for noise reduction in wide band frequencies is proposed and their possibility is experimentally investigated. Multi-mode damping is studied by using a newly proposed tuning method. The proposed panels are based on passive shunt damping methods. This method is based on electrical impedance model and maximizing the dissipated energy at the shunt circuit. four PZT are attached on smart panel for improving performance of transmission noise reduction. 0 prove the concept of piezoelectric smart panels, an acoustic measurement experiment was performed. The smart panels exhibit a good noise reduction in middle and high frequency ranges due to the mass effects of absorbing materials or/and the air gap. The use of piezoelectric smart panel renders noise reduction at resonance frequency. Noise reduction at multiple resonance frequencies is experimentally investigaed.

  • PDF

Measurement of Gas Concentration and flow Rate Using Hot Wire (열선을 이용한 혼합기체의 농도와 유량의 측정)

  • Kim, Young-Han;Park, Jong-Jueng
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

Developement of Simulation Model for Analysis of Hydraulic Systems in Injection Molding Machine (1) (사출성형기 유압시스템 분석용 시뮬레이션 모델 개발 (1))

  • 신성철;박영진;김진영;이강걸
    • Journal of the Korea Society for Simulation
    • /
    • v.11 no.4
    • /
    • pp.25-32
    • /
    • 2002
  • Hydraulic systems of injection molding machine are modelled and simulated with AMESim which is a commercial program. Detail models of hydraulic components are simulated and simulation results are evaluated with maker's test results in catalog. Sub system models which is divided according to functional operation are made and its analysis results shows how design parameters work on operational characteristics like cylinder speed, cylinder displacement, pressure, flow rates at each node and so on. Total circuit model is also made and analyzed. The prediction made by simulation will be used design of hydraulic systems of injection molding machine.

  • PDF

Evaluation of Corrosion Resistance Properties of Hexagonal Boron Nitride Based Polymer Composite Coatings for Carbon Steel in a Saline Environment

  • Alabdullah, Fadhel T.;Ali, C.;Mishra, Brajendra
    • Corrosion Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.41-52
    • /
    • 2022
  • Herein, we report polyvinyl butyral composites coatings containing various loadings of 72-h bath sonicated hexagonal boron nitride particles (5 ㎛) to enhance barrier properties of coatings. Barrier properties of coatings were determined in 3.5 wt% NaCl after different time periods of immersion via electrochemical techniques such as open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization test. Coatings containing sonicated hexagonal boron particles exhibited improved corrosion resistance for longer periods of immersion compared to neat coating. We also discussed effects of hexagonal boron nitride on healing properties of polyvinyl butyral. Coatings containing 1.0 wt% loading of sonicated hexagonal boron nitride showed improved long-term barrier properties than coatings with other compositions. The presence of hexagonal boron nitride also affected the healing properties of polyvinyl butyral coatings besides their barrier properties. Such improved barrier properties of composites coatings were attributed to the high aspect ratio, plate-like shape, and electrically insulated nature of the filler.

Characteristics Operation of a Flux-offset Type Fault Current Limiter in a Double line-to-line Fault (2선 단락 사고 시 자속상쇄형 한류기의 동작 특성)

  • Choi, Hye-Won;Choi, Hyo-Sang
    • Journal of Advanced Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.131-135
    • /
    • 2014
  • In this paper was proposed a flux offset-type fault current limiter as means of reducing fault currents. To secure the operation reliability of a flux offset-type fault current limiter, constructed a simulation system to analyze its operation characteristics by generating a double line-to-line fault. According to the test results, the system performed stably without any impedance. However, when an accident occurred, the flux-offset of magnetic was not occurred. Because of this, any impedance occurred at circuit. It was confirmed that the impedance was low and fast to limit the fault current. At this time, the fault current limited rate was about 95%.