• Title/Summary/Keyword: impulse radio

Search Result 146, Processing Time 0.02 seconds

Smart Air Conditioning Service Using Bio-signal and Emotional Lighting (생체신호와 감성조명을 이용한 스마트 에어컨 서비스)

  • Kim, Jong-Min;Ryu, Gab-Sang
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.9
    • /
    • pp.31-37
    • /
    • 2021
  • Recently, in the market of home appliances, the technical differentiation of products using convergence technology has been receiving a lot of response to satisfy consumer demand. However, air-conditioner products are an area that requires research and development in the early stages of convergence technology. In this paper, it is developed that a non-contact bio-signal(respiration, movement) collection technology using IR-UWB(Impulse-Radio Ultra Wideband) technology, which controls the air-conditioner direction according to the user's location and also monitors sleep to provide an optimal sleep environment. In addition, emotional lighting and ASMR are developed to provide a comfortable and emotional place of life. Finally, based on the developed convergence technology, we develop intelligent smart air-conditioning services for the convenience of daily life and a comfortable resting space.

A Study and Design of Beam Scanning Array Antenna using IR-UWB (IR-UWB를 이용한 빔 스캐닝 배열 안테나 설계 및 연구)

  • Kim, Keun-Yong;Kang, Eun-Kyun;Kim, Jin-Woo;Ra, Keuk-Whan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.194-201
    • /
    • 2014
  • This paper is able to be solved by improving degradation in multi-path environment by adjust beam pattern angle through modifying pulse phase of each antennas by using TRM (Transmitter Receiver Module). Beam Scanning Array Antenna, which is transmitter/receiver that improves degradation in multi-path environment without any signal distortion, is designed and manufactured. Beam Scanning Array Antenna should be able to send/receive signal at the antenna's longitudinal part without distortion and should not influences other systems. Also, it should include target detecting ability by beam steering.Dispersion characteristic of Beam Scanning Antenna, which is designed, is analysed by using fidelity, and steering and radar resolution performance is verified by using $1cm{\times}1cm$ sized target. To manufacture Beam Scanning Array Antenna, control board and GUI, which is able to control Vivaldi Antenna for IR-UWB, Tri-Band Wilkinson power divider, and TRM (Transmitter Receiver Module), is designed. Throughout this research, developed Beam Scanning UWB Array Antenna system is adoptable for radar application field. and time domain analysis techniques by using network analyser made the antenna characteristics analysis for setting up antenna more accurate. In addition, it makes beam width checking without difficulties.

Properties of TiN films prepared by using the DC sputtering and HIPIMS. (DC 스퍼터링과 HIPIMS로 제조한 TiN 박막의 특성 비교)

  • Byeon, In-Seop;Yang, Ji-Hun;Jeong, Jae-Hun;Kim, Seong-Hwan;Jeong, Jae-In
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.102-102
    • /
    • 2016
  • 본 연구에서는 직류 전원(direct current; DC)을 이용한 스퍼터링과 고전력펄스 마그네트론 스퍼터링(high-power impulse magentron sputtering; HIPIMS)의 두 가지 방법과 빗각 증착을 적용하여 제조한 티타늄 질화물(TiN) 박막의 미세구조 변화가 물성에 미치는 영향을 확인하였다. TiN 박막은 99.5%의 Ti 타겟을 사용하고, Ar가스와 $N_2$ 분위기에서 스테인리스(SUS304)와 초경(cdmented carbide; WC-10wt.%Co) 기판위에 코팅하였다. 기판은 알코올과 아세톤으로 초음파 세척을 실시한 후 진공용기에 장착하고 기본 진공도인 ${\sim}2.0{\times}10^{-5}Torr$ 까지 진공배기를 실시하였다. 기판과 타겟 간의 거리는 DC 스퍼터링은 10 cm, HIPIMS 스퍼터링은 8.5 cm 이었다. 진공용기의 압력이 기본 진공도까지 배기되면 Ar 가스를 ${\sim}10^{-2}Torr$로 주입한 후 기판에 라디오 주파수(radio frequency; RF) 전원으로 약 -800 V의 전압을 인가하여 글로우 방전을 발생시키고 약 30 분간 청정을 실시하였다. 기판의 청정이 끝난 후 기본 진공도까지 배기한 후 Ar와 $N_2$ 가스를 ${\sim}10^{-3}Torr$로 주입하여 TiN 코팅을 실시하였다. 빗각의 크기는 $45^{\circ}$$-45^{\circ}$이며, TiN 박막의 총 두께는 약 $2.5{\sim}4.0{\mu}m$ 로 유지하였다. 공정조건에 따라 TiN 박막의 주상정은 형태와 기울어진 각도가 다른 것을 확인하였다. DC 스퍼터링으로 제조된 TiN 박막은 기판홀더에 약 -100 V 의 bias 전압을 인가하면 인가하지 않은 박막에 비해 치밀한 박막의 성장과 경도 값도 증가하는 사실을 확인하였다. 또한 빗각을 적용하고 bias 전압을 인가하지 않은 시편에서 박리현상이 일어났다. HIPIMS로 제조한 TiN 박막은 bias 전압을 인가한 박막과 인가하지 않은 박막의 주상정 형상과 경도 값에 큰 차이가 없었으며, 박막의 박리현상은 모든 시편에서 일어나지 않았다. DC 스퍼터링으로 제조한 TiN 박막은 bias 전압을 인가하지 않으면 색상이 노란색이 아닌 갈색으로 나타났으며, HIPIMS으로 제조한 박막은 bias 전압 인가 유무에 상관없이 노란색 색상을 나타냈다. 앞서 설명한 DC 스퍼터링과 HIPIMS의 공정조건에 따라 나타난 박막의 경도, 색상, 물성변화 차이는 DC 스퍼터링보다 높은 HIPIMS의 이온화율에서 기인한 것으로 생각된다. 본 연구결과를 이용하면 다양한 형태의 박막 구조 제어가 가능하고 이러한 미세구조 제어를 통해서 박막의 물성도 제어가 가능할 것으로 판단된다.

  • PDF

A Study on Male High School Students' Smoking Patterns (일부 남자 고등학생의 흡연 실태에 관한 조사연구)

  • Lee, Gi-Yeong
    • The Korean Nurse
    • /
    • v.36 no.5
    • /
    • pp.91-100
    • /
    • 1998
  • This study aims to investigate smoking patterns in high school student and to give student smoker effective information. The sample of 250 male highschool students out of two different schools in Tae-Jon was questioned from July 10th to 15th. 1995. In analyzing these date. the statistics shows the realities by means of number of students. The results are summarized into 17 items as follows. Regarding the level of smoking. 140 students out of 250 admit that they have ever smoked. 52.1% of smoking students say that the motivation of beginning smoking is mainly curiosity. The survey shows that 22.9% of smoking students feel very good when smoking. It also shows that 30.0% of smoking students began smoking in the first grade of high school. With regard to the volume of smoking per day. 41.4% of smoking students smoke variably. 42.1% drink when smoking. 15.0% spend more than W 70.000 a month. About the question who knows the fact of their smoking. 51.5% answer that their friends know the fact of their smoking. In regard to the resaltionship between smoking and school per-formance. 18.2% of non smoking students make poor grades as compared with 40% of smoking students. 9.3% of smoking students say that they are satisfied with the school life. but 35.7% of them are not satisfied. Regarding the attitude to smoking teachers. 35% of smoking students state that they are affected by them. 69.3% of smoking students say that they will stop smoking. while the remaining 30.7% say that they will keep smoking. The reason of 63.9% to stop smoking is that smoking is bad for the health. The reason of 46. 5% to keep smoking is the acquired habit of smoking. 97.2% know the fact that the major element of cigarettes is nicotine and it is very harmful to the health. 40.8% recognize the harmful effect of smoking by TV and radio programs. 97.2% know that smoking could cause lung cancer. From the above results. I propose as follows We should make specific plan to keep smoking by simple curiosity from being developed into habitual smoking. We should teach them how harmful smoking is and make them stop smoking by themselves. It is very essential for family members and teachers to give continuous interest since childhood. As the teacher affect the students very much, they should give up smoking first. The incidence of smoking should be identified in each of the middle and high schools. smoking prohibition programs relevant to each school should be developed and implemented. The local community should ban cigarette vending machines. Cigarettes should not be sold to adolescents. By setting every place where adolescents gather including schools nonsmoking area. we should decrease their impulse to smoke. then smoking opportunities. and harmful effects to them caused by passive smoking.

  • PDF

The Study on Change in Sex-Related Knowledge and Attitude through Sex Education : focusing on the 1st grade students in girls' junior high schools (성교육 실시에 따른 성지식, 성태도 변화 연구 -1학년 여중생을 대상으로-)

  • 계수연;문인옥
    • Korean Journal of Health Education and Promotion
    • /
    • v.16 no.2
    • /
    • pp.137-155
    • /
    • 1999
  • The purpose of this study was to assess the effect of sex education on knowledge and attitude related to sex. The subjects were taken from by 199 students in 3 classes from 1st grade in H girl's junior high school as the study group, and 2 classes from 1st grade in S girl's junior high school as control group. During the survey period(September 21, 1998 to September 30, 1998), 6 times in terms of one-hour class for sex education were taught to the study group. A pre-test was executed on September 19, 1998 and the post-test on September 30. The findings were as follows. 1. According to the research, 20.1% of the subjects have experienced sex education from parents and 89.9% from teacher. They have mostly obtained the sex-related information from teachers(59.8%), following movie, radio, TV, or video tape(40.7%), friends(35.2%), reading materials such as books, cartoons, news papers and magazines(31.7%), parents(15.6%), siblings(7.0%), PC(1.5%) and telephone service(1.5%). 2. 27.1% of the subjects reported that they had sex-related worry concerning from friendship with the opposite sex, following physiological phenomenon(31.5%), sex violence(11.1%), physical characteristics(7.4%), VD and contraception(5.6%), sexual impulse(5.6%), pregnancy and delivery(5.5%), and sexual behaviour(3.7%). The research showed that the adolescents usually solved their problems through the consultation with theifriends(44.4%). However, 16.7% of the subjects were turned out not to request any solution. The other minor routes to settle their problems were written materials such as books, magazines(13.0%), parents(13.0%), movie, radio, TV, or video tape(5.5%), acquainted female elders(3.7%) and teachers(3.7%). 3. The most interesting part regarding sex was the friendship with the opposite sex(61.8%), following adolescent's emotion(55.8%), physiological differences between two genders(52.8%), AIDS(48.7%), VD(46.7%), pregnancy(45.2%), contraception(45.2%), abortion(41.7%), intercourse(41.7%), masturbation(41.2%), sex violence(41.2%) and genital structure and secondary sexual characteristics(28.6%). 4. In regard to characteristics of the subjects influencing sex-related knowledge, the higher educational career of mother, living with at least either parent and the experience of sex education by teachers were statistically significant factors(p〈0.05). 5. In regard to characteristics of the subjects influencing attitudes toward sex, the experience of sex education by parents or teachers was a statistically significant factor(p〈0.05). 6. The analysis of knowledge score comparing results before and after sex education showed that control group's score decreased from 12.5 to 12.44 while the study group's score increased from 12.33 to 21.31, which was statistically significant(p〈0.001). 7. The analysis of the attitude scores before and after sex education showed that the control group's score slightly increased from 55.57 to 56.36, while the study group's score increased from 54.79 to 61.95, which was statistically significant(p〈0.001). 8. The level of sex-related concerns of the study group after sex education marked both the increase in some items and the decrease in others. 9. Most instructive session among the sex education was the third “to be a good friend to the opposite sex”(27.0%).

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF