• 제목/요약/키워드: improve water quality

검색결과 1,185건 처리시간 0.026초

운암지 수변공원 설계 (Design of Unam-Ji Waterfront Park)

  • 박찬용
    • 한국조경학회지
    • /
    • 제28권4호
    • /
    • pp.117-124
    • /
    • 2000
  • This paper presents a design of urban waterfront park using agricultural reservoir in urban fringe area to meet increasing leisure demand for urban resident and to improve resident's quality of life through preventing the reservoir from urban use after reclamation. The site, Unam-Ji, is located on northern part of Taegu metropolitan area, having 17,791 square meters. We had designed this park from 1997 to 1998. After analyzed such factor as accessibility, current land uses, topography, hydrology, vegetation and landscape, climate, and soil, we constructed basic design scheme and principes such as conservation of natural resources, meeting user's recreation demands, providing opportunities for experiencing natural process, integrating naturalness and amenity of the site, and comfortable place with natural dynamism. Based on these principles, we have designed Unam-Ji waterfront park having intrinsic characteristics of the site, maintaining water quality and ecological restoration and improving water-based recreation opportunities. After evaluation of such criteria of design alternative as land use and circulation, spatial organization, convenience for use of and maintenance, conservation of natural environment, and degree of achieving planning and design goals, and maintaining landscape, we have visualized and formalized waterfront park in design process, which is consisted of four squares-- green square for multiple uses, water-based recreation square, pedestrian roads and decks near waterfront, performance square and fords near waterfront. In conclusion, this waterfront park design contributes to improve quality of urban development through preserving agricultural as an important component of urban water system and provide important planning and design implications in urban open space planning.

  • PDF

Quality Improvement of Rayon Grade Bamboo Pulp by Modified Bleaching

  • Tripathi, Sandeep;Mishra, Om Prakash;Sharma, Nirmal;Chakrabarti, Swapan Kumar;Varadhan, Raghavan
    • 펄프종이기술
    • /
    • 제43권2호
    • /
    • pp.1-8
    • /
    • 2011
  • The presence of high silica in bamboo hinders the use of this material for production of rayon grade pulp. Research has been carried out to overcome this deficiency and improve quality of rayon grade pulp with the modification in pulping and bleaching process. Effect of acid boosted water prehydrolysis, sulphuric acid pre-treatment of unbleached pulp, chlorination stage at lower pH and treatment of bleached pulp with $SO_2$ water were evaluated. Acid boosted water prehydrolysis of chips reduces prehydrolysis time by 50 minutes as compared to water prehydrolysis. Treatment of unbleached pulp with sulphuric acid reduces ash, acid insoluble, silica, calcium and iron contents of the pulp by 56, 31, 82, 84 and 60% respectively. The addition of acid, increase in kappa factor in $C_D$ stage and combination of both were effective in removing silica in the pulp. Treatment of final bleached pulp with $SO_2$ water removes silica to a great extent and improves optical properties of the pulp as compared to $H_2SO_4$ or PAA. Pretreatment of the pulp with acid and modification in the bleaching process can reduce silica substantially and improve the quality of rayon grade bamboo pulp.

수질계측센서의 성능분석 및 센서 융합기술에 관한 연구 (A study on performance analysis and merging techniques of sensors in water quality measurement)

  • 양근호;유병국
    • 융합신호처리학회논문지
    • /
    • 제7권3호
    • /
    • pp.143-148
    • /
    • 2006
  • 정수장에서 생산한 수돗물이 수용가까지 안전하게 공급하기 위해서는 관내 및 배수지 등의 공급과정에서 철저한 수질관 리가 필요하다. 그러나 배수지의 수질관리 및 모니터링이 전혀 이루어지지 않고 있다. 최근 정부는 먹는 물에 대한 수질관리기준을 강화하고 있으나, 먹는 물에 대한 수질측정 기반기술은 미국, 일본, 독일 등에 비하여 매우 빈약하다. 특히 수질 검사 및 분석기기의 핵심은 센서이나 이들 센서에 대한 기술이 매우 부족하다. 본 논문에서는 국내 먹는 물 수질관리에 대한 관계 법령 및 규정을 분석하고, 먹는 물 수질측정 기준에 적합한 pH, 전도도, 잔류염소, 탁도 및 수온에 대한 센서 및 측정기기의 최적 성능기준을 제안하고, 대표적인 전극센서인 pH, 전도도 및 잔류염소 센서의 상호간섭 및 영향을 분석한다.

  • PDF

Design of Lake Ecological Observation Data Management

  • Ahn, Bu-Young;Jung, Young-Jin;Lee, Myung-Sun;Jeong, Choong-Kyo;Kim, Bom-Chul
    • International Journal of Contents
    • /
    • 제7권1호
    • /
    • pp.45-51
    • /
    • 2011
  • To protect water pollution and scarcity in lake and river, water quality monitoring applications have become important tools to understand the change of aquatic ecosystem. KLEON (Korean Lake Ecological Observatory Network) is designed to manage and share the ecological observations. The various kinds of water quality and phytoplankton observations are collected from the selected observatories such as seven lakes/rivers/wetlands. To deeply understand the collected observations with weather, KLEON also manages the observatory information such as lake, dam, floodgate, and weather. The accumulated observation and analyzed results are used to improve the water quality index of the observatories and encourage the ecologists' cooperation.

Optimum Sewage Discharge Strategy for Coastal Waters

  • Kang, Yun-Ho;Lee, Moon-Ock
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제10권S_3호
    • /
    • pp.97-106
    • /
    • 2001
  • To improve the water quality, particularly for sea bathers, the behaviour of wastewater from sewage outfalls in water adjacent to Swansea, UK, was studied using a mathematical model. The water quality in the sewage receiving basin was determined using factors like the outfall diffuser location(distance from land boundary), sewage treatment scheme, discharge time, and bacteria decay rate, etc. With respect to these factors, an optimal strategy for sewage discharge was then investigated to minimize bacteria levels along the bathing beaches. As water quality criteria, predicted faecal coliform levels were monitored along the coast adjacent to the outfall locations. The resultant values were compared with EC Mandatory(<2000, 95 % of 20 samples) and Guideline Standards(< 100, 80 % of 20 samples). For the advective-diffusion equation, the non linear advective terms were represented using the ULTIMATE algorithm and the third-order accurate QUICKEST scheme to avoid numerical diffusion. Details of the simulation results are then presented as an optimal policy for sewage discharge in the region.

  • PDF

갈수기 지하수 물 사용량 저감 및 기저유출 수질 개선 방안 연구 (A Study on How to Reduce the Amount of Groundwater Used in the Dry Season and Improve the Water Quality of the Base Runoff)

  • 강태성;양동석;유나영;신민환;임경재;김종건
    • 한국농공학회논문집
    • /
    • 제64권2호
    • /
    • pp.27-35
    • /
    • 2022
  • Based on the current status of groundwater usage in the dry season through field surveys, this study tried to suggest countermeasures to reduce groundwater usage and to improve the water quality of baseflow from agricultural fields. For this purposes, basins with water curtain cultivation preceded were targeted where decreases of groundwater due to continuous use of groundwater in spring and winter annually observed. From monitoring groudwater usage of the study watershed, 130,058, 130,105 m3/day of water was pumped in during the water curtain cultivation period (October-February) in the Shindun, Seokwon watershed respectively. And the pilot application of the smart automated sensor-based water curtain cultivation system (smart WC system) developed in this study to reduce groundwater consumption has been conducted. As a result, the efficiency of the smart WC system when threshold temperature is set as 6.3 ℃ was 21.1% compared to conventional cultivation and efficiency increased as threshold temperature gets lower. Lastly, in this study, culvert drainage and Bio-filters were installed and rainfall monitoring was performed 15 times in order to analyze the baseflow securement and pollutant loads behavior. As a result, the test-bed with culvert drainage and Bio-filter installed together generated 61.4% more baseflow (4.974 m3) than the test-bed with only culvert drainage was installed (3.056 m3). However, the total pollutant load of all water quality contents (BOD, COD, T-N, TOC) except for the SS and T-P was found to be greater in the culvert drain and Bio-filter installed than in the culvert drain test-bed.

Application of Water Quality Management System of Freshwater Lake

  • Kim, Sun-Joo;Kim, Phil-Shik;Lee, Joo-Young
    • 한국농공학회지
    • /
    • 제45권7호
    • /
    • pp.38-48
    • /
    • 2003
  • Lake water quality assessment information is useful to anyone involved in lake management, from lake owners to lake associations. It provides lake water quality criteria, which can improve the ways how to manage out lake resources and how to measure current conditions. It also provides a knowledge base so that the lakes can be protected and restored. Here, the Freshwater Lake Water Quality Management System(FLAQUM) was developed. The results of FLAQUM application by scenario proved that pollutant load at rainfall by the nonpoint sources was much more than normal times at rainfall. From the result of Scenario I (pollutant source increase case), the concentrations of Boryeong freshwater lake were BOD 9.43mg/L, T-N 4.53 mg/L and T-P 0.21 mg/L, respectively, and those values exceed the standard of agricultural water. And in case of Scenario I and II(the present case) excluding Scenario III (pollutant source decrease case), all of T-N and T-P are either mesotrophication or eutrophication, on the other hand when 60% of pollution source is removed, the concentrations of Scenario III were BOD 3.21 mg/L, T-N 0.95 mg/L, T-P 0.11 mg/L, respectively, and which satisfies the standard of agricultural water quality.

계층적 수질모의기법을 이용한 상수관망시스템의 시공간 잔류염소농도 예측 (Spatiotemporal chlorine residual prediction in water distribution networks using a hierarchical water quality simulation technique)

  • 정기문;강두선;황태문
    • 한국수자원학회논문집
    • /
    • 제54권9호
    • /
    • pp.643-656
    • /
    • 2021
  • 최근 국내 상수도 관리 기술은 고도로 발달하고 있으며, 이 과정에서 상수관망 내 용수공급 현황을 파악하고 예측하기 위한 컴퓨터 수리·수질 해석 모형은 핵심적인 역할을 수행하고 있다. 그러나 대규모 네트워크의 경우 컴퓨터 해석모형의 부담을 가중하고, 특히 짧은 계산시간 간격과 긴 모의 시간이 요구되는 수질해석의 경우, 막대한 계산시간이 소요되어 다양한 수질모의 및 분석이 어려운 경우가 발생한다. 본 연구에서는 대규모 상수관망시스템의 수질해석의 계산효율을 개선하기 위해 상수도 공급계통을 2단계로 계층화한 후, 계층화된 네트워크를 대상으로 수질모의를 수행하는 계층적 수질모의 기법을 제안하였다. 제안된 모의기법은 국내 대규모 상수도 네트워크에 적용하였으며, 다양한 염소투입농도 시나리오에 따른 잔류염소농도의 시공간적 분포를 모의하고 분석한 결과를 제시하였다.

Towards a novel approach to improve drinking water quality at Dhaka, Bangladesh

  • Serajuddin, Md.;Chowdhury, Md. Aktarul Islam
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.136-142
    • /
    • 2018
  • The river water source of Saidabad Surface Water Treatment Plant at Dhaka, Bangladesh, is deteriorated too much to be treated by conventional treatment process due to excessive ammonia pollution. In order to improve the raw water quality before it enters into the main treatment chain, a pilot study was conducted for pre-treatment of the raw water. The objective is to investigate the rate of reduction of ammonia using the Meteor pilot, a biological pretreatment system, which is a laboratory scale Moving Bed Biofilm Reactor with a nominal volume of hundred liters, filled with 50 L of Meteor 660 media. The reduction of ammonia was quite significant on average 73%, while the reduction of COD was in a range from 20 to 60%. The Meteor pilot was able to treat and nitrify the raw water and produce an effluent that respects the guarantee of ammonia < $4.0mg\;NH_3-N/L$ when the raw water ammonia concentration was < $15mg\;NH_3-N/L$. The study identified operating parameters necessary to achieve the desired goal of adequate ammonia removal. The study results would benefit a range of systems across the country by providing guidance on the design and operation of a biological pre-treatment system for ammonia removal.

개별배출시설 삭감잠재량 분석을 통한 수질오염총량제의 민간참여 활성화 방안 연구 (A Study on the Activation of Non-government Participation in Total Maximum Daily Load System using Private Discharge Facilities Reduction Potential Analysis)

  • 김홍태;신동석;김현정;최인욱;이미선;김용석
    • 한국물환경학회지
    • /
    • 제31권6호
    • /
    • pp.715-722
    • /
    • 2015
  • Four major river basin in Korea has been managed with Total Maximum Daily Load(TMDL) System. Water quality indicators as targeted pollutants for TMDL were BOD and TP. In order to satisfy water quality criteria, government allocation using public treatment facilities and its action plan has been used. However, the role to improve water quality were recently faced to its limitation. It is time to require the role of non-government allocation in private discharge facilities to control good water quality. This study investigated three different scenarios in reduction demands of non-government allocations about industry and private sewages. The three different scenarios were discharge under 1) legal water quality standard, 2) water quality level in 2011 and 3) current water quality level with maximum value in group. The results showed that reduction potential in water discharge for TP indicator was 1,118kg/day, under second scenario with 20% of deduction. This results arrived at 42% of whole reduction potential costs and 0.012mg/L improvement in water quality. In conclusion, to intrigue voluntary participation in non-government allocation, various benefits such as tax reduction, tax exemption, and water quality trading should be provided.