• Title/Summary/Keyword: impression tray

Search Result 82, Processing Time 0.025 seconds

Fabrication of mandibular suction denture for complete edentulous patient: A case report (하악 흡착식 의치를 이용한 완전 무치악 환자의 총의치 수복 증례)

  • Park, Minhyuk;Park, Sang-Won;Lim, Hyun-Pil;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.257-267
    • /
    • 2020
  • The goal of suction denture is to enhance retention of dentures by the formation of negative pressure between the denture base and the underlying tissue and sealing around the denture by the mucosa. This patient has been converted to a completely edentulous state after the extraction of residual teeth. Fabrication of suction denture was planned because it was estimated that the conventional compete would be hard to achieve retention due to the absorption of residual ridge and lack of sublingual fold. Through appropriate clinical and laboratory technique such as preliminary impression on the mandibular rest position, provisional vertical dimension determination with Centric Tray® (Ivoclar Vivadent AG, Schaan, Liechtenstein), closed mouth definitive impression and jaw relation record using individual tray with Gnathometer M® (Ivoclar Vivadent AG, Schaan, Liechtenstein), artificial teeth arrangement considering stability of the denture, and proper polymerization technique that minimizes polymerization shrinkage, restoring the patient with suction denture resulted in satisfaction throughout the function and asesthetics.

Implant-assisted removable partial denture for severely atrophied mandible (심한 하악 치조제 흡수를 가진 환자에서 임플란트를 이용한 가철성 국소의치로 수복한 증례)

  • Choi, Bada;Kim, Yeun Ju;Lee, Jae Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.171-175
    • /
    • 2019
  • Mandible with severe alveolar bone atrophy poses a significant challenge in terms of reproducing clinically acceptable anatomy for a removable prosthesis. To overcome this potential complication, altered cast impression technique is often recommended to capture accurate and functional gingiva tissues. It becomes possible to get proper anchors functional impression by placing 2 implants crowns which were impossible in previous implant overdenture impression technique. In this case, an 80-year old female patient with severe mandibular ridge atrophy was treated with an implant-assisted removable partial denture with two implant crowns on the canine area. An altered cast impression was taken with an individual tray on a metal framework of removable partial denture on both posterior edentulous areas. The patient was satisfied with the final prosthesis after failure of 2 previous prostheses. Clinician had a difficult time to manage disabled patient and patient were suffered with ill-fitting denture due to inaccurate impression in conventional overdenture condition. The oral rehabilitation was completed with placing 2 implants as proper anchor.

Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction

  • Pereira, Ana Larisse Carneiro;Medeiros, Vitoria Ramos;Campos, Maria de Fatima Trindade Pinto;Medeiros, Annie Karoline Bezerra de;Yilmaz, Burak;Carreiro, Adriana da Fonte Porto
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.212-222
    • /
    • 2022
  • PURPOSE. To evaluate and compare the effect of impression type (conventional vs digital) and the number of implants on the time from the impressions to the generation of working casts of mandibular implant-supported fixed completearch frameworks, as well as on patient satisfaction. MATERIALS AND METHODS. 17 participants, 3 or 4 implants, received 2 types of digital impression methods (DI) and conventional (CI). In DI, two techniques were performed: scanning with the scan bodies (SC) and scanning with a device attached to the scan bodies (SD) (BR 10 2019 026265 6). In CI, the making of a solid index (SI) and open-tray impression (OT) were used. The outcomes were used to evaluate the time and the participant satisfaction with conventional and digital impressions. The time was evaluated through the timing of the time obtained in the workflow in the conventional and digital impression. The effect of the number of implants on time was also assessed. Satisfaction was assessed through a questionnaire based on seven. The Wilcoxon test used to identify the statistical difference between the groups in terms of time. The Mann-Whitney test was used to analyze the relationship between the time and the number of implants. Fisher's test was used to assess the patient satisfaction (P<.05). RESULTS. The time with DI was shorter than with CI (DI, $\tilde{x}=02:58$; CI, $\tilde{x}=31:48$) (P<.0001). The arches rehabilitated with 3 implants required shorter digital impression time (3: $\tilde{x}=05:36$; 4: $\tilde{x}=09:16$) (P<.0001). Regarding satisfaction, the DI was more comfortable and pain-free than the CI (P<.005). CONCLUSION. Digital impressions required shorter chair time and had higher patient acceptance than conventional impressions.

Digital impression taking for full-arch implant restoration to a patient with microstomia (디지털 인상채득을 이용한 소구증을 가진 환자의 전악 임플란트 수복)

  • Shim, Ji Suk;Ryu, Jae Jun
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.616-621
    • /
    • 2018
  • This clinical case highlights the failure of long length implants, and the prosthodontic procedures necessary to rehabilitate the maxillary dentition of a patient with microstomia. The integrated digital technology of intra-oral scanning, computer-aided design, and three-dimensional printing can provide an alternative method to make conventional impressions for patients with microstomia who cannot insert the appropriate tray in their mouths.

  • PDF

EFFECT OF IMPRESS10N TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS (인상채득법이 임플랜트 주모형의 정확성에 미치는 영향)

  • Kim Young-Oh;Yang Hong-So;Vang Mong-Sook;Park Sang-Won;Park Ha-Ok;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.63-72
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and Method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on future level (Group FIX-D), 2) Indirect method on fixture level(Group FIX-I), 3) Modified indirect method on fixture level(Group FD(-M), 4) Direct method on abutment level(Group AB-D) and 5) Indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^(R)$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results: The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2 In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error.

IN VITRO STUDY OF TOOTH TEMPERATURE CHANGE DURING POLYMERIZATION REACT10N OF THE COLD-CURED RESINS USED IN PROVISIONAL CROWN AND FIXED PARTIAL DENTURES (자가 중합 임시수복용 레진의 경화 시 외부환경 변화에 따른 치아의 온도변화)

  • Oh, Wu-Sik;Baik, Jin;Kim, Hyung-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.503-513
    • /
    • 2006
  • Statement of the problem: The cold-cured resins used in fabrication of the provisional crown and fixed partial dentures could cause pulpal damage by heat generated during exothermic polymerization reactions. Purpose: In this in vitro study investigates the how external conditions such as material of the matrix, thickness of the matrix and thickness of dentin affect the temperature of the tooth during polymerization reaction of the cold-cured resins. Material and methods : To measure the temperature of the resin, metal die was maintained to the temperature of $37^{\circ}C$ with water bath to simulate the temperature of thetooth and thermocouple was placed in the center of the metal die. Acrylic pipe was cut in height of 1, 2, 3, 6, 10 mm and placed on the metal die and mixed resin was pored in the acrylic pipe As the resin polymerized temperature was recorded with the thermometer. Temperature of the resin using matrix was recorded by using the individual tray relieved in different thickness 2, 5, 7, 10 mm. The material of the matrix was irreversible hydrocolloid impression material, vinyl polysilloxane impression material and vacuum-formed template Temperature rise of the resin using different thickness of tooth section was record ed by placing tooth section on the metal die and placing resin over the tooth section. Results : Conclusion : 1. Temperature rise increased as the thickness of the resin increased but there was no significant differences over 3 mm thickness of the resin. 2. The lowest temperature rise was showed in irreversible hydrocolloid impression material and vinyl polysilloxane impression material vacuum-formed template as in orders. 3, Temperature rise of the resin decreased regardless of the thickness of the matrix when vinyl polysilloxane impression material was used as the matrix. 4 When irreversible hydrocolloid impression material was used as matrix, the temperature rise of the resin decreased as the thickness of the matrix increased and there was no temperature rise when thickness of the matrix reached 10 mm, 5. The temperature rise of the resin did not decreased when Polypropylene vacuum-formed template was used as the matrix. 6, The temperature of the resin increased as the thickness of the dentin decreased.

Evaluation of functional suitable digital complete denture system based on 3D printing technology

  • Deng, Kehui;Chen, Hu;Wang, Yong;Zhou, Yongsheng;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.361-372
    • /
    • 2021
  • PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

THE CARE OF DELAYED MALUNION AFTER MAXILLARY FRACTURE BY DIFFERENT METHODS:REPORT OF THREE CASES (치료법을 달리한 상악골절후 부정유합 2예)

  • Yoo, Jae-Ha;Lee, Won-Yoo;Rew, Soo-Jang
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.117-127
    • /
    • 1991
  • When open reduction of maxilla fractures is postponed due to concurrent life-threatening injuries, delayed union may result with malunion or nonunion. If delayed malunion is occurred, significant facial deformity may result, including a dished-out face, irregular retromaxillism with Angle's class III malocclusion, open anterior bite, nasal collapse, telecanthus and malar flattening. The treatment planning for this problem includes cephalometric evaluation anterior and lateral tomograms, dental casts, orthodontic planning, dental planning and use of impression tray to rupture the fibrous tissue casts, orthodontic planning, dental planning and use of impression tray to rupture the fibrous tissue attachment at the fracture site. In this paper, one case presented a 58-year-old female patient with maxilla retrusion after comminuted fracture, who was treated with orthodontic methods of maxillary protraction headgear and Plaster headcap, whereas the other two cases were about male patients who were treated principally with surgically open reduction or Le Fort I-controlled transverse osteotomy with iliac bone graft.

  • PDF

Fabrication of complete denture using conventional method and monolithic digital denture system: a case report (전통적 제작법과 모놀리식(monolithic) 디지털 의치 시스템을 이용한 상·하악 총의치 동시 수복 증례)

  • Young-Baek Park;Ga-Hyun Lee;Young-Gyun Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.6-19
    • /
    • 2024
  • With the advancement of Computer-Aided Design/Computer-Aided Manufacturing (CAD-CAM) technology, fabrication of dentures using this technology has gained popularity. As one of CAD-CAM technologies, digital complete denture system has been introduced, which fabricates complete dentures using subtractive manufacturing of monolithic block containing both the color of a denture base and an artificial tooth. In this case, two pairs of upper and lower dentures were fabricated for two patients. Two pairs of complete dentures were fabricated for a 74-year-old male and a 73-year-old female respectively by conventional denture fabrication method and digital method of milling. To obtain a digital complete denture, monolithic block (Ivotion, Ivoclar Vivadent, Schaan, Liechtenstein) was chosen for the materials to fabricate the digital complete dentures. An individual tray was designed using CAD software and manufactured by 3D printing technique. The final impression and interocclusal relationship were recorded using the fabricated individual tray. The final impression was scanned, and the complete denture design and try-in denture were 3D printed using CAD-CAM software. Subsequently, the monolithic block was milled, and the final dentures were fabricated and tried on patients. Previously mentioned two patient cases compared and analyzed stability, fit, speaking, mastication, aesthetics, and patient satisfaction of two pairs of dentures: one fabricated using CAD-CAM system and the other using traditional methods. This was performed to evaluate and report the findings from both denture-making approaches.

THREE-DIMENSIONAL ANALYSIS OF THE NORMAL DENTITION AND EDENTULOUS MAXILLA OF KOREANS (한국인의 상악 유치악 치열 및 무치악 치조제에 관한 삼차원적 연구)

  • Kim Hyeong-Seop;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.191-203
    • /
    • 2005
  • Statement of problem. In Korea, the preliminary impression trays for dental and edentulous maxillae are manufactured on the base of the statistical value of Westerners. There had been less study on the dental and edentulous arches of Koreans. Purpose. The purpose of this study was to evaluate an average dental cast, preliminary impression trays, three-dimensional relation of dental and edentulous maxilla of Koreans Material and methods. The subjects for this study were 173 dental casts of maxilla (dental: 52, edentulous : 146) with ages $18\{\sim}60$ years old. Each of the master casts was measured 69 measuring points on the dental cast or maxilla, and 46 measuring points on the edentulous cast of maxilla with three-dimensional digital measuring machine. Each measuring points were analysed and were overlapped, that three dimensional dental graphic manufactured by CAD/CAM system. Results. 1. A standard of distribution to alveolar bone were width between left and right buccal border lines of the standard 3/4 line. The mean value of dental and edentulous casts were 67.27mm, 63.49mm respectively. 2. Morphological classification of dental casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 17%, 16%, 67%, respectively. Dimensional classification of the dental casts were divided into five groups of less than 63mm, 63 up to 65mm, 65 up to 67mm. 67 up to 69mm, more than 69mm, respectively. 3. Morphological classification of edentulous casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 18%, 17%, 65%, respectively Dimensional classification of the edentulous casts were divided into five groups of less than 57mm, 57 up to 61mm, 61 up to 65mm, 65 up to 69mm, more than 69mm, respectively. 4. Mean dental and edentulous cast of maxilla were overlapped, the proportion of bone resorption to alveolar bone is higher than that of palatal bone, its difference were higher anterior 2/4 area than posterior 3/4 area. Conclusion. It obtains information of preliminary impression trays for dental and edentulous maxilla of Koreans.