• Title/Summary/Keyword: implant survival

Search Result 324, Processing Time 0.025 seconds

Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study

  • Kim, Sung-Beom;Kim, Young-Kyun;Kim, Su-Gwan;Oh, Ji-Su;Kim, Byung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.6
    • /
    • pp.247-252
    • /
    • 2014
  • Purpose: This study compares the prognosis (the survival rate and marginal bone loss) of resorbable blasting media (RBM) surface implants and sandblasting with large-grit and acid-etching (SLA) surface implants in the early loading. Methods: This study targeted 123 patients treated by implants installation from January 2008 to March 2010. The loading was initiated in the maxilla within three to four months and in the mandible within one to two months. The types of restoration were single crown and fixed partial prosthesis. Those functioned over one year. The implants were classified by the surface of implants as Group 1: RBM surface (GS III; OSSTEM, Busan, Korea) and, Group 2: SLA surface (Superline; Dentium, Seoul, Korea). The groups were categorized by maxilla and mandible and compared by survival rate, marginal bone loss through clinical records evaluation, and radiographic measurements. Results: The marginal bone loss in the maxilla was $0.14{\pm}0.34mm$ (Group 1) and $0.30{\pm}0.37mm$ (Group 2), a statistically significant difference (P<0.05). In the mandible those were $0.28{\pm}0.54mm$ (Group 1) and $0.20{\pm}0.33mm$ (Group 2), not significant (P>0.05). There was no significant difference of marginal bone loss between maxilla and mandible by groups. During observation there was no implant failure, a survival rate of 100%. Conclusion: Both surfaces showed an excellent survival rate, and the marginal bone loss was not substantial.

The Distribution of Implant Patients and the Type of Implant Site (임플란트 환자의 분포 및 식립부 유형)

  • Park, Ji-Eun;Yun, Jeong-Ho;Jung, Ui-Won;Kim, Chang-Seong;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.4
    • /
    • pp.819-836
    • /
    • 2004
  • Nowdays, the awareness of implant treatment has grown rapidly among dentists and patients alike in Korea, as it becomes a widely accepted treatment. The reason is that unlike crown and bridge or denture treatment, implant treatment helps preserve existing bone and improve masticatory functions. So, It is needed understanding about the type, distribution of implant patient. The following results on patient type and implant distribution were compiled from 4433 implant cases of 1596 patients treated at the periodontal dept. of Y University Hospital during 1992 to 2004. 1. There are no dissimilarities between men and women, with patients in their 40, 50s accounting for 52.5% of patients and 57.5% of implant treatments; the largest share of patients and implant treatments. 2. Mn. posterior area accounted for 54.9% of implant treatments followed by Mx. posterior area(27.6%), Mx anterior area(11.9%) and Mn anterior area(5.6%). 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 97.5% and fully edentulous patient accounted for the remaining 2.5%. 4. The major cause of tooth loss is periodontal disease, followed by dental caries, trauma and congenital missing. Also, older people are more likely to suffer from tooth loss due to periodontal disease rather than dental caries. 5. In the distribution of bone quality for maxillae, type III was most, followed by type II, r type IV and r type I. As for mandible, type II was most, followed by type III, type IV and for type I. 6. In the distribution of bone quantity for maxillae, type C was most, followed by type B, type D, type A, and for type E. As for mandible, type B was 52% most, followed by type C, type D, type A and type E. 7. The majority of implants were those of 1O-14mm in length (85.2%) and regular diameter in width (64%). The results provided us with basic data on patient type, implant distribution, bone condition, etc. We wish that our results coupled with other research data helps assist in the further study for better implant success/survival rates, etc.

Evaluation of Crestal Bone Resorption of the TiUnite(R) Anodized Implant System

  • Kim, Young-Kyun;Ahn, Min-Seok;Lee, Yang-Jin;Yun, Pil-Young
    • Journal of Korean Dental Science
    • /
    • v.1 no.1
    • /
    • pp.4-9
    • /
    • 2008
  • Purpose : This study sought to examine the aspects of crestal bone resorption and to evaluate the clinical outcomes of the TiUnite$^{(R)}$ (Nobel Biocare, Sweden) anodized implant system. Materials and Methods : Among the 67 patients (211 fixtures) who were treated using TiUnite(r) implants at Seoul National University Bundang Hospital between March 2004 and January 2007, 26 (91 fixtures) were considered in this study. Initial and secondary stabilities were measured using Periotest$^{(R)}$ and Ostell(tm) Mentor. The radiographic evaluation of crestal bone resorption was carried out by measuring the change in crestal bone level at the time of surgery compared to that 1 year after loading. Panoramic radiograph and periapical radiograph were used. Based on the radiographic findings, the shapes of crestal bone resorption were classified. Results : The average amount of crestal bone resorption after 1 year of functional implant loading was 0.30 mm. There was no saucerization in 40 implant fixtures (43.9%), although more than 1 thread were exposed in 51 implant fixtures (56.6%). The success rate of the implants was 94.5%, and the survival rate was 100%. Conclusions : Good clinical outcomes and minor crestal bone resorption were noted in this study. Saucerization for the establishment of biological width was not a general finding in the TiUnite$^{(R)}$ anodized implant system.

  • PDF

The factors that influence postoperative stability of the dental implants in posterior edentulous maxilla

  • Kim, Yun-Ho;Choi, Na-Rae;Kim, Yong-Deok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.2.1-2.6
    • /
    • 2017
  • Background: All clinicians are aware of the difficulty of installing a dental implant in posterior maxilla because of proximate position of maxillary sinus, insufficient bone width, and lower bone density. This study is to examine which factors will make the implantation in the posterior maxilla more difficult, and which factors will affect the postoperative implant stability in this region. Methods: Five hundred seventy-three fixtures on the maxilla posterior were included for this study from all the patients who underwent an installation of the dental implant fixture from January 2010 to December 2014 at the Department of Oral and Maxillofacial Surgery in Pusan National University Dental Hospital (Yangsan, Korea). The postoperative implant stability quotient (ISQ) value, fixture diameter and length, presence of either bone graft or sinus lift, and graft material were included in the reviewed factors. The width and height of the bone bed was assessed via preoperative cone beam CT image analysis. The postoperative ISQ value was taken just before loading by using the OsstellTM $mentor^{(R)}$ (Integration Diagnostics AB, Gothenburg, Sweden). The t test and ANOVA methods were used in the statistical analysis of the data. Results: Mean ISQ of all the included data was 79.22. Higher initial bone height, larger fixture diameter, and longer fixture length were factors that influence the implant stability on the posterior edentulous maxilla. On the other hand, the initial bone width, bone graft and sinus elevation procedure, graft material, and approach method for sinus elevation showed no significant impact associated with the implant stability on the posterior edentulous maxilla. Conclusions: It is recommended to install the fixtures accurately in a larger diameter and longer length by performing bone graft and sinus elevation.

INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS (임플란트 직경이 골유착에 미치는 영향에 관한 연구)

  • Lee Jun-Ho;Shin Sang-Wan;Kwon Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

The analysis of cost-effectiveness of implant and conventional fixed dental prosthesis

  • Chun, June Sang;Har, Alix;Lim, Hyun-Pil;Lim, Hoi-Jeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.53-61
    • /
    • 2016
  • PURPOSE. This study conducted an analysis of cost-effectiveness of the implant and conventional fixed dental prosthesis (CFDP) from a single treatment perspective. MATERIALS AND METHODS. The Markov model for cost-effectiveness analysis of the implant and CFDP was carried out over maximum 50 years. The probabilistic sensitivity analysis was performed by the 10,000 Monte-Carlo simulations, and cost-effectiveness acceptability curves (CEAC) were also presented. The results from meta-analysis studies were used to determine the survival rates and complication rates of the implant and CFDP. Data regarding the cost of each treatment method were collected from University Dental Hospital and Statistics Korea for 2013. Using the results of the patient satisfaction survey study, quality-adjusted prosthesis year (QAPY) of the implant and CFDP strategy was evaluated with annual discount rate. RESULTS. When only the direct cost was considered, implants were more cost-effective when the willingness to pay (WTP) was more than 10,000 won at $10^{th}$ year after the treatment, and more cost-effective regardless of the WTP from $20^{th}$ year after the prosthodontic treatment. When the indirect cost was added to the direct cost, implants were more cost-effective only when the WTP was more than 75,000 won at the $10^{th}$ year after the prosthodontic treatment, more than 35,000 won at the $20^{th}$ year after prosthodontic treatment. CONCLUSION. The CFDP was more cost-effective unless the WTP was more than 75,000 won at the $10^{th}$ year after prosthodontic treatment. But the cost-effectivenss tendency changed from CFDP to implant as time passed.

Clinical Evaluation of Simultaneous Implants Placement Following Augmentation of the Maxillary Sinus with Deproteinized Bovine Bone (탈단백 우골을 이용한 상악동 거상술 후 즉시 임플란트 식립에 대한 임상적 평가)

  • Kim, Hyun-Kuk;Kim, Jin-Wook;Kim, Chin-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.249-255
    • /
    • 2011
  • Purpose: Placement of endosseous implants in the atrophic maxilla is often restricted because of the lack of supporting bone. In this article, augmentation of the maxillary sinus floor with deproteinized bovine bone to enable insertion of endosseous implants is described. The technique is aimed at providing a cortical layer on top of the graft to ensure a reliable seal of the maxillary sinus and to achieve optimal stability of the bone graft in case of simultaneously placement of dental implants. Methods: The procedure was used in 200 patients (839 implants), using deproteinized bovine bone. The mean follow-up was 28.5 months. No inflammation of the bone grafts nor of the maxillary sinus occurred. The patients received implant supported overdentures or bone-anchored bridges. Results: The survival rate of implant restoration of this study was 97.6%. The total average of marginal bone loss in radiographs was $0.20{\pm}0.38$ mm. Insufficient primary stability, bony quality, and infection were thought to be associated factors in the failed cases. Conclusion: This study documented that deproteinized bovine bone, when used as a grafting material for augmentation of the sinus floor, may lead to proper osseointegration of a endosseous implant.

A RETROSPECTIVE EVALUATION OF IMPLANT INSTALLATION WITH MAXILLARY SINUS AUGMENTATION BY LATERAL WINDOW TECHNIQUE (측방접근법을 이용한 상악동거상술 후 임프란트 식립에 대한 후향적 평가)

  • Ki, Se-Il;Yu, Min-Gi;Kim, Young-Joon;Kook, Min-Suk;Park, Hong-Ju;Shet, Uttom Kumar;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.457-464
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the clinical results of implants which were installed with maxillary sinus elevation by using lateral window technique. Materials and methods: We performed the maxillary sinus elevation by lateral window technique to 87 patients who visited Dept. of Oral & Maxillofacial Surgery, Chonnam National University Hospital from January, 2003 to January, 2007. When the residual bone height was from 3 mm to 7 mm, the sinus elevation and simultaneous implant installation was mostly performed. When the residual bone height was less than 3 mm, the sinus elevation was performed and the delayed implant installation was done after 5 or 6 months. No artificial membranes were used for coverage of the lateral bony window site and freeze dried fibrin sealant was applied to the grafted bone. The mean follow-up period was 28.5 months (ranged from 10 months to 48 months) Results: 1. Unilateral sinus elevations were performed in 51 patients and bilateral sinus elevations were performed in 36 patients. And the total number of sinus elevation procedure was 123 cases. 2. The sinus elevation and simultaneous implant installation was performed in 89 sinuses and 249 implants were installed. The sinus elevation and delayed implant installation was performed in 44 sinuses and 141 implants were installed. The total number of implants were 390 in 133 sinuses. The average healing period after sinus elevations was 6.1 months in delayed implant installation. 3. Only autogenous bone, autogenous bone mixing with allografts or autogenous bone mixing with xenografts were used as graft materials. 4. The average period from first surgery to second surgery was about 7.2 months. 5. Some patients complications, such as perforation of sinus membrane, swelling, infection and exposure of cover screw. Two implants were removed in the infected sinus. 6. The survival rate of implants with maxillary sinus elevation by lateral window technique was 99.5% and the success rate of implants was 95.1%. Conclusions: These results indicated that the implants which were installed with maxillary sinus elevation by lateral window technique showed high survival and success rates.

Limb-Salvage Surgery using Ilizarov Technique - Report of 2 cases - (Ilizarov술식을 이용한 사지 구제술 - 2례 보고 -)

  • Cho, Duck-Yun;Koh, Eun-Sung;Lee, Ji-Sup
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.226-232
    • /
    • 1995
  • Survival rate of osteosarcoma has been improved recently due to the neoadjuvant and adjuvant chemotherapy. Limb-salvaging operation(LSO) has replaced the amputation technique without' lowering the survival rate. And there occurred a lot of patients who are suffering from the high cost of artificial implants and forced to choose amputation due to economic problem. In LSO, usually relatively high cost artifical implant is needed. When a patient and not afford such an expensive implant he had to choose an inexpensive way, amputation. Authors tried bone lengthening by adopting Ilizarov technique after wide resection of tumor in two patients. Bone transportation was successful in one patient and less successful in the other. One case in CDF(continuosly disease free since the surgical procedure) state at follow-up 3 year 4 months after knee joint fusion. And the other was given lobectomy for lung metastasis at postop. 1 year and 9 months, and given osteosynthesis for infected nonunion at the docking site. Bone transportation was thought to be a good method for the bony coverage of dead space caused by wide resection. Bone transportation technique was economical as well as biological We present two osteosarcoma patient who treated with Ilizarov bone transportation.

  • PDF

Evaluation of a Visible Implant Fluorescent Elastomer Tag in the Soft-shelled Turtle, Pelodiscus sinensis

  • Park, Min-Ouk;Seol, Dong-Won;Im, Soo-Yeon;Hur, Woo-June;Park, In-Seok
    • Fisheries and Aquatic Sciences
    • /
    • v.10 no.4
    • /
    • pp.226-229
    • /
    • 2007
  • Survival, tag retention and tag readability were compared among the control and three treatment groups of soft-shelled turtles, Pelodiscus sinensis Crother, 2000 (mean body $weight{\pm}SD$: $182.6{\pm}13.7\;g$), marked with visible implant fluorescent elastomer (VIFE) tags for 16 months. Mortality 4 to 16 months after tagging was attributed to collection and handling stress rather than to the tagging itself. Tags applied to the web surface between the fourth and fifth dactyl of the hindfoot appeared to have the highest retention rates, while adipose eyelid tagging had high tag readability but a high loss rate. We conclude that in soft-shelled turtles, the most suitable region for VIFE tagging is on the web surface between the fourth and fifth dactyls of the hindfoot.