• Title/Summary/Keyword: implant stability

Search Result 493, Processing Time 0.024 seconds

Root coverage with subeptithelial connective tissue grafts (상피하결합조직 이식술을 이용한 치근면 피개)

  • Song, Hyun-Jong;Jang, Hyun-Seon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.625-636
    • /
    • 2007
  • Marginal tissue recession makes problems like esthetics, root caries, hypersensitivity and plaque accumulation. Request for root coverage is higer than ever, especially esthetic problems involved. So techniques for root coverage hav been developed. There are some kinds of surgical techniques using soft tissue for root coverage. For example, free gingival graft, kinds of pedicle flap, subepithelial connective tissue graft(SCTG), and so on. Subepithelial connective tissue graft has many advantage for root coverage, that is less pain on donor site, good blood supply for graft, and more esthetic result. For this reaseon, this case report was performed to evaluate the effect of root coverage using subepithelial connective tissue graft. Three patients has Miller's class I marginal tissue recession and one patients has Miller's class III marginal tissue recession. The following period is 36.5 month on average. The results are as follows: 1. Root coverage of 100% was obtained in 5 of 6 defects, and 80% was obtained in 1 of 6 defects, The mean root coverage was 96,6% in six cases on 4 patients. 2. The mean root coverage was 3.83mm and mean recession depth decreased from 4mm to 0.16mm. 3. The mean width of clinical attached gingiva increased from 1.5mm to 4mm. The mean width of gained attached gingiva after surgery was 2.5mm. 4. The mean follow up period was 36.5 months. The longest follow up period was 50 months and the shortest follow up period was 22 months. 5. The result that obtained by surgery was stable during follow up period. Within the above results, root coverage with SCTG is an effective procedure to cover marginal tissue recession defect with long term stability.

MIDIFACIAL CHANGES FOLLOWING THE PARANASAL AUGMENTATION WITH ALLOPLASTIC $MEDPOR^{(R)}$ (인공이식재 $MEDPOR^{(R)}$ 를 이용한 중안모증가술(PARANASAL AUGMENTATION)과 측모의 변화)

  • Kim, Sun-Jong;Kim, Myung-Rae;Choi, Jang-Woo;Jung, Sang-Hoon;Lee, Chang-Kook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.2
    • /
    • pp.177-183
    • /
    • 1996
  • With the increasing esthetic requirement in orthognathic surgeries, midfacial corrective surgeries were developed to improve the paranasal depression. Augmentation with autogenous bones has long been the standard in facial reconstruction, however limited graft availability, donor site morbidity, and difficulties in 3-dimensional shaping were led to limited use. Porous high density polyethylene$(Medpor{(R)})$ was introduced in the 1970s as an alloplastic implants. It can be used in various size and shapes, and shortend operation time. The purpose of this study is to determine, by means of cephalometrics, the degree of long term stability and gaining of the overlying soft tissue thickness. The results were as followings : 1. There was no evidence of foreign body reaction, infection, and tissue necrosis. 2. $(Medpor{(R)})$ implants had an advantage of clinical use ; easy to contour and adapt to obtain a precise 3-dimensional construction. 3. Cephalometric study of 16 cases of paranasal augmentation revealed an overall increase of soft tissue thickness of approximately 82.1% in 6-months following. 4. The successful results could be obtained under the aseptic handling.

  • PDF

Histomorphometric analysis of microcrack healing after the installation of mini-implants

  • Shin, Soobin;Park, Pan-Soo;Baek, Seung-Hak;Yang, Il-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.62-68
    • /
    • 2015
  • Purpose: The goal of this study was to investigate the histomorphometric characteristics of the healing process of microcracks in the cortical bone after the installation of mini-implants (MIs). Methods: Self-drilling MIs were inserted into the tibial diaphysis of twelve adult male New Zealand rabbits. Four MIs per rabbit were placed randomly. The animals were divided into four groups according to the length of the healing period: group A was sacrificed immediately, group B was sacrificed after one week, group C was sacrificed after two weeks, and group D was sacrificed after four weeks. Cortical bone thickness was measured using micro-computed tomography, and histomorphometric analyses of the cumulative length of the microcracks (CLCr) and the total number of microcracks (NCr) were performed using hematoxylin and eosin staining. Results: The microcracks were radially and concentrically aligned in the peri-MI bone. The CLCr decreased significantly one week after the surgery, mainly due to healing of the concentrically aligned microcracks. The CLCr showed another significant decrease from two weeks after the surgery to four weeks after the surgery, mainly reflecting healing of the radially aligned microcracks. A statistically significant decrease in the NCr occurred as the microcracks healed from zero weeks to two weeks. However, no significant difference in the NCr was found between groups C and D. Conclusions: In order to improve the primary stability of MIs, delayed loading and a healing period of a certain length are recommended to ensure the optimal healing of microcracks and bone remodeling.

Wear Resistance of c-BN Surface Modified 316L Austenitic Stainless Steel by R.F. Sputtering (R.F. sputtering 방법에 의해 c-BN 표면처리된 316L 오스테나이트계 스테인리스 강의 내마모특성 향상)

  • Lee, Kwang-Min;Jeong, Se-Hoon;Park, Sung-Tae
    • Korean Journal of Materials Research
    • /
    • v.20 no.4
    • /
    • pp.194-198
    • /
    • 2010
  • Cubic boron nitride (c-BN) is a promising material for use in many potential applications because of its outstanding physical properties such as high thermal stability, high abrasive wear resistance, and super hardness. Even though 316L austenitic stainless steel (STS) has poor wear resistance causing it to be toxic in the body due to wear and material chips, 316L STS has been used for implant biomaterials in orthopedics due to its good corrosion resistance and mechanical properties. Therefore, in the present study, c-BN films with a $B_4C$ layer were applied to a 316L STS specimen in order to improve its wear resistance. The deposition of the c-BN films was performed using an r.f. (13.56 MHz) magnetron sputtering system with a $B_4C$ target. The coating layers were characterized using XPS and SEM, and the mechanical properties were investigated using a nanoindenter. The friction coefficient of the c-BN coated 316L STS steel was obtained using a pin-on-disk according to the ASTM G163-99. The thickness of the obtained c-BN and $B_4C$ were about 220 nm and 630 nm, respectively. The high resolution XPS spectra analysis of B1s and N1s revealed that the c-BN film was mainly composed of $sp^3$ BN bonds. The hardness and elastic modulus of the c-BN measured by the nanoindenter were 46.8 GPa and 345.7 GPa, respectively. The friction coefficient of the c-BN coated 316L STS was decreased from 3.5 to 1.6. The wear property of the c-BN coated 316L STS was enhanced by a factor of two.

Development of Implantable Blood Pressure Sensor Using Quartz Wafer Direct Bonding and Ultrafast Laser Cutting (Quatrz 웨이퍼의 직접접합과 극초단 레이저 가공을 이용한 체내 이식형 혈압센서 개발)

  • Kim, Sung-Il;Kim, Eung-Bo;So, Sang-kyun;Choi, Jiyeon;Joung, Yeun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.168-177
    • /
    • 2016
  • In this paper we present an implantable pressure sensor to measure real-time blood pressure by monitoring mechanical movement of artery. Sensor is composed of inductors (L) and capacitors (C) which are formed by microfabrication and direct bonding on two biocompatible substrates (quartz). When electrical potential is applied to the sensor, the inductors and capacitors generates a LC resonance circuit and produce characteristic resonant frequencies. Real-time variation of the resonant frequency is monitored by an external measurement system using inductive coupling. Structural and electrical simulation was performed by Computer Aided Engineering (CAE) programs, ANSYS and HFSS, to optimize geometry of sensor. Ultrafast laser (femto-second) cutting and MEMS process were executed as sensor fabrication methods with consideration of brittleness of the substrate and small radial artery size. After whole fabrication processes, we got sensors of $3mm{\times}15mm{\times}0.5mm$. Resonant frequency of the sensor was around 90 MHz at atmosphere (760 mmHg), and the sensor has good linearity without any hysteresis. Longterm (5 years) stability of the sensor was verified by thermal acceleration testing with Arrhenius model. Moreover, in-vitro cytotoxicity test was done to show biocompatiblity of the sensor and validation of real-time blood pressure measurement was verified with animal test by implant of the sensor. By integration with development of external interrogation system, the proposed sensor system will be a promising method to measure real-time blood pressure.

An Assessment of Image Analysis of Longitudinal Bone Changes (시간경과에 따른 골변화의 영상 분석에 관한 연구)

  • Kim Young-Jin;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.73-86
    • /
    • 1997
  • This study was performed to assess the analyzing methods developed to detect clinically and quantitatively longitudinal bone changes. Through preliminary experiment, accuracy of Cu-Eq value conversion to the mass of HA was examined. For main experiment, 15 intraoral radiograms taken at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture in extracted sites of 3 cases were used. We took the radiograms with copper step wedge as test object and HA phantom X -ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner into computer were digitized and analyzed by NIH image program. The stability of the copper equivalent transformation and the usefulness of two analyzing methods by ROI and Reslice were examined. Obtained results as follows: 1) On the Cu equivalent images, the coefficient of variation in the measurement of Cu-Eq. value of ROI ranged from 0.05 to 0.24 and showed high reproducibility. 2) All results obtained by resliced contiguous image were coincident with those obtained from the assessment by ROI and formation of plot profile. 3) On the stacked and resliced image at the line of interest, we could analyze directly and quantitatively the longitudinal changes at several portions by plot profile and qualitatively by surface plot. 4) Implant area showed marked resorption till 2 weeks after implantation and showed significant increase in Cu-Eq. value at 6th week(p<0.01) and periapical area showed increase in Cu-Eq. value at 6th week compared to after-operation's.

  • PDF

Effect of loading time on marginal bone loss around hydroxyapatite-coated implants

  • Kim, Young-Kyun;Ahn, Kyo-Jin;Yun, Pil-Young;Kim, Minkyoung;Yang, Hong-So;Yi, Yang-Jin;Bae, Ji-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.4
    • /
    • pp.161-167
    • /
    • 2013
  • Objectives: The objective of this study is compare the rate of marginal bone resorption around hydroxyapatite-coated implants given different loading times in order to evaluate their stability. Materials and Methods: The study was conducted retrospectively for one year, targeting 41 patients whose treatment areas were the posterior maxilla and the mandible. Osstem TS III HA (Osstem Implant Co., Busan, Korea) and Zimmer TSV-HA (Zimmer Dental, Carlsbad, CA, USA), which employ the new hydroxyapatite coating technique, were used. The patients were divided into two groups - immediate and delayed loading - and the bone level at the time of loading commencement and after one year of loading was measured using periapical radiography. Differences between the groups were evaluated using Mann-Whitney (${\alpha}$=0.05). Results: For all patients as a single group, the survival rate of the implants was 100%, and the mean marginal bone loss was $0.26{\pm}0.59mm$. In comparison of the differences by loading, mean marginal bone loss of $0.32{\pm}0.69mm$ was recorded for the immediate loading group whereas the delayed loading group had mean marginal bone loss of $0.16{\pm}0.42mm$. However, the difference was not significant (P>0.05). Conclusion: Within the limited observation period of one year, predictable survival rates can be expected when using immediately loaded hydroxyapatite-coated implants.

Effects of Several Herbal Medicines on Alkaline Phosphatase Activity in Human Fetal Osteoblasts (수종의 생약제제가 human fetal osteoblasts의 염기성 인산분해 효소 활성에 미치는 영향)

  • Lee, Myoung-Ku;Choi, Hee-In;You, Hyung-Keun;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.1
    • /
    • pp.49-60
    • /
    • 2003
  • Several growth factors and polypeptides are not commonly yet used for regenerators of bone tissue or alveolar bone because of the insufficiency of studies on their side effects, genetic engineering for mass production and stability for clinical application. Recently, many herbal medicines, which have advantage of less side effects and possibility of long-term use, have been studied for their capacity and effects of anti-bacterial, antiinflammatory and regenerative potential of periodontal tissues. Morindae Radix, Cibotium Barometz (L.), Albizziae Cortex, Cistandhis Herba have been traditionally used as medicines for treatment of bone disease in Eastern medicine. The objective of the present study is to examine the ability of alkaline phosphatase (ALP) activity of human fetal osteoblast (hFOB1) when several natural medicines were supplemented. hFOB1 were cultured with Dulbecuo's Modified Eagle's Medium Nutrient Mixture F-12 HAM ( DMEM/F-12 1:1 Mixture, Sigma, USA) and negative control, dexamethasone (positive control), and each natural medicines for 3 days. And then ALP activity was measured by spectrophotometer for enzyme activity and Alizarin red S staining for morphometry. Among the natural medicines of this study, Morindae Radix, Cibotium Barometz (L.) and Cistanchis Herba induced higher activity of ALP synthesis than negative controls in all experimental group. Albizziae Cortex showed mild increases than negative control group. According to measurement of positively stained area, all of the natural medicines of this study increased compared to negative control. Especially, Cibotium Barometz (L.) and Cistanchis Herba showed statistical significance compared to negative control (p<0.05). These results indicate that Morindae Radix, Cibotium Barometz (L.), Albizziae Cortex, Cistandhis Herba have an inducing ability of ALP synthesis on osteoblast.

Effect of bite force on orthodontic mini-implants in the molar region: Finite element analysis

  • Lee, Hyeon-Jung;Lee, Kyung-Sook;Kim, Min-Ji;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.43 no.5
    • /
    • pp.218-224
    • /
    • 2013
  • Objective: To examine the effect of bite force on the displacement and stress distribution of orthodontic mini-implants (OMIs) in the molar region according to placement site, insertion angle, and loading direction. Methods: Five finite element models were created using micro-computed tomography (microCT) images of the maxilla and mandible. OMIs were placed at one maxillary and two mandibular positions: between the maxillary second premolar and first molar, between the mandibular second premolar and first molar, and between the mandibular first and second molars. The OMIs were inserted at angles of $45^{\circ}$ and $90^{\circ}$ to the buccal surface of the cortical bone. A bite force of 25 kg was applied to the 10 occlusal contact points of the second premolar, first molar, and second molar. The loading directions were $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$ to the long axis of the tooth. Results: With regard to placement site, the displacement and stress were greatest for the OMI placed between the mandibular first molar and second molar, and smallest for the OMI placed between the maxillary second premolar and first molar. In the mandibular molar region, the angled OMI showed slightly less displacement than the OMI placed at $90^{\circ}$. The maximum Von Mises stress increased with the inclination of the loading direction. Conclusions: These results suggest that placement of OMIs between the second premolar and first molar at $45^{\circ}$ to the cortical bone reduces the effect of bite force on OMIs.

Tomographic and histometric analysis of autogenous bone block and synthetic hydroxyapatite block grafts without rigid fixation on rabbit calvaria

  • Bae, Soo-Yong;Park, Jung-Chul;Shin, Hyun-Seung;Lee, Yong-Keun;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.251-258
    • /
    • 2014
  • Purpose: The preferred material for bone augmentation beyond the envelope of skeletal bone is the bone block graft, due to its dimensional stability. We evaluated the necessity of rigid fixation for the bone block graft, and compared the bone regeneration and volume maintenance associated with grafting using a synthetic hydroxyapatite block (HAB) and an autogenous bone block (ABB) without rigid fixation on rabbit calvaria over two different periods. Methods: Cylinder-shaped synthetic HAB and ABB were positioned without fixation on the rabbit calvarium (n=16). The animals were sacrificed at 4 or 8 weeks postoperatively, and the grafted materials were analyzed at each healing period using microcomputed tomography and histologic evaluation. Results: Integration of the graft and the recipient bed was observed in all specimens, although minor dislocation of the graft materials from the original position was evident in some specimens (six ABB and ten HAB samples). A tendency toward progressive bone resorption was observed in the grafted ABB but not in the grafted HAB, which maintained an intact appearance. In the HAB group, the area of new bone increased between 4 and 8 weeks postoperatively, but the difference was not statistically significant. Conclusions: The nonfixed HAB was successfully integrated into the recipient bed after both healing periods in the rabbit calvaria. In spite of limited bone formation activity in comparison to ABB, HAB may be a favorable substitute osteoconductive bone material.