• 제목/요약/키워드: implant size

검색결과 293건 처리시간 0.028초

Electrochemical Behavior of Plasma Electrolytic Oxidized Films Formed in Solution Containing Mn, Mg and Si Ions

  • Lim, Sang-Gyu;Choe, Han Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.80-80
    • /
    • 2017
  • Titanium and its alloys that have a good biocompatibility, corrosion resistance, and mechanical properties such as hardness and wear resistance are widely used in dental and orthopedic implant applications. However, they do not form a chemical bond with bone tissue. Plasma electrolytic oxidation (PEO) that combines the high voltage spark and electro-chemical oxidation is a novel method to form ceramic coatings on light metals such as tita-nium and its alloys. This is an excellent re-producibility and economical, because the size and shape control of the nano-structure is relatively easy. Silicon (Si), manganese (Mn), and magne-sium (Mg) have a useful to bone. Particularly, Si has been found to be essential for normal bone, cartilage growth, and development. Mn influences regulation of bone remodeling be-cause its low content in body is connected with the rise of the concentration of calcium, phosphates and phosphatase out of cells. Pre-studies have shown that Mg plays very im-portant roles in essential for normal growth and metabolism of skeletal tissue in verte-brates and can be detected as minor constitu-ents in teeth and bone. In this study, Electrochemical behavior of plasma electrolytic oxidized films formed in solution containing Mn, Mg and Si ions were researched using various experimental in-struments. A series of Si-Mn-Mg coatings are produced on Ti dental implant using PEO, with the substitution degree, respectively, at 5 and 10%. The potentiodynamic polarization and AC impedance tests for corrosion behav-iors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV. Also, AC impedance was performed at frequencies anging from 10MHz to 100kHz for corrosion resistance.

  • PDF

완전 이식형 보청기 기술 평가 기반의 새로운 이식형 음향센서 제안 (Proposition of a New Implantable Acoustic Sensor Based on Technology Evaluation of Fully Implantable Hearing Aids)

  • 조진호;우승탁;임형규;정의성;이정현;이승하;성기웅
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.178-184
    • /
    • 2014
  • Key components of implantable hearing aids are consist of an acoustic sensor that collect external sound by suppressing the body noise, a signal processor module for compensation algorithm of hearing loss, and a output transducer which has tiny size but have high efficiency, respectively. In the partial implantable hearing aids, technologies of transducer and signal processor are so matured that can be applied not too much difficulty. However, due to the difficulties in implantable acoustic sensor technology, such as minimization of masticatory sound and damage of sensor's membrane from external impact, practical use of fully implantable hearing aids have not successful so far. In this paper, we have proposed a novel implantable acoustic sensor which has trans-tympanic structure, and is verified that the proposed method can be very useful for fully implantable hearing aids by cadaveric experiments.

유방전용감마카메라에서 유방 보형물이 영상에 미치는 영향에 관한 고찰 (A Study on Effect of the Image Applying to Breast Implants in Breast Specific Gamma Imaging)

  • 이주영;이태수;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.33-38
    • /
    • 2018
  • There are limits to check the lesion as inserting a breast implant patients. So the application of BSGI based on Nuclear Medicine examination has increased. In this study, therefore we confirmed the effect of the image applying to breast implants in Breast Specific Gamma Imaging. We utilized Dilon 6800 BSGI scanner and developed the phantom. The self-development phantom was a rectangular shape of $230{\times}190{\times}80mm$ size and had 5 spheres which consisted of diameters of 10, 13, 17, 22, 28 mm in central part. We injected $^{99m}TcO_4$ into the self-development phantom in the proportion of four to one and made each additional phantom filled with 0.9 % sodium chloride, silicon and paraffin. Each additional phantom was placed between detector and self-development phantom. Each image was acquired five times depending on the type and thickness of the additional phantom. Statistical analysis with SPSS ver.18 was applied. In the test of variation according to the thickness of all additional phantoms, as the phantoms which 0.9% sodium chloride, silicon and paraffin increased, the attenuation variation was higher(P<0.005). There was no significant difference in the attenuation variation and the quality of image for type of the additional phantom. Therefore, if the effect of the image applying to breast implants in Breast Specific Gamma Imaging is confirmed, the higher diagnostic value can be achieved.

Transaxillary Capsulorrhaphy with Reimplantation to Correct Bottoming-Out Deformity in Breast Mycobacterial Periprosthetic Infection: A Case Report with Literature Review

  • Tsung-Chun Huang;Jian-Jr Lee;Kuo-Hui Yang;Chia-Huei Chou;Yu-Chen Chang
    • Archives of Plastic Surgery
    • /
    • 제50권6호
    • /
    • pp.557-562
    • /
    • 2023
  • Augmentation mammoplasty is one of the most popular cosmetic surgeries, but there is a high reoperation rate (29.7%) commonly due to capsular contracture, implant malpositioning, infection, and unsatisfactory size. Although infection only accounts for 2% of cases, its management is very challenging, especially with nontuberculous mycobacteria (NTM) infection. Breast prosthetic NTM infection is a rare but is a disastrous condition with an incidence of approximately 0.013%. Immediate salvage reimplantation is usually not suggested, and most studies recommend a gap of 3 to 6 months after combination antibiotics therapy before reimplantation. However, delayed reimplantation often leads to great psychological stress and struggle between the doctor and patient. We present the case report of successful reimplantation in treating prosthetic NTM infections in a 28-year-old female. We discuss a novel technique "transaxillary capsulorrhaphy" to correct the bottoming-out deformity. One year after the combination of antibiotics and surgery, the follow-up computed tomography scan showed complete remission of NTM without recurrence. We discuss the surgical technique in detail. The 1-year follow-up assessment (photos and dynamic video) revealed good cosmesis and reliable correction using the new technique. This report is the first formal description and discussion of one-stage reimplantation following NTM infections. Transaxillary capsulorrhaphy allows for a successful salvage operation when an implant is displaced. This approach provides highly favorable result in eastern women undergoing revision augmentation mammoplasty. This study reflects level of evidence V, considering opinions of respected authorities based on clinical experience, descriptive studies, or reports of expert committees.

BIOLOGICAL RESPONSES OF OSTEOBLAST-LIKE CELLS TO DIFFERENT TITANIUM SURFACE BY ANODIZING MODIFICATION

  • Kim Myung-Joo;Kim Chang-Whe;Lim Young-Jun;Park Hyun-Joo
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.751-763
    • /
    • 2005
  • Statement of problem. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. The surface quality of the implant depends on the chemical, physical, mechanical and topographical properties of the surface. The different properties will interact with each other and a change in thickness of the oxide layer may also result in a change in surface energy, the surface topography and surface, chemical composition. However, there is limited the comprehensive study with regard to changed surface and biologic behavior of osteoblast by anodization. Purpose of study. The aim of this study was to analyze the characteristics of an oxide layer formed and to evaluate the cellular biologic behaviors on titanium by anodic oxidation (anodization) by cellular proliferation, differentiation, ECM formation and gene expression. And the phospholipase activity was measured on the anodized surface as preliminary study to understand how surface properties of Ti implant are transduced into downstream cellular events. Methods and Materials. The surface of a commercially pure titanium(Grade 2) was modified by anodic oxidation. The group 1 samples had a machined surface and other three experimental specimens were anodized under a constant voltage of 270 V(Group 2), 350 V(Group 3), and 450 V(Group 4). The specimen characteristics were inspected using the following five categories; the surface morphology, the surface roughness, the thickness of oxide layer, the crystallinity, and the chemical composition of the oxide layer. Cell numbers were taken as a marker for cell proliferation. While the expression of alkaline phosphatase and Runx2 (Cbfa1) was used as early differentiation marker for osteoblast. The type I collagen production was determined, which constitutes the main structural protein of the extracellular matrix. Phospholipase $A_2$ and D activity were detected. Results. (1) The anodized titanium had a porous oxide layer, and there was increase in both the size and number of pores with increasing anodizing voltage. (2) With increasing voltage, the surface roughness and thickness of the oxide film increased significantly (p<0.01), the $TiO_2$phase changed from anatase to rutile. During the anodic oxidization, Ca and P ions were more incorporated into the oxide layer. (3) The in vitro cell responses of the specimen were also dependant on the oxidation conditions. With increasing voltage, the ALP activity, type I collagen production, and Cbfa 1 gene expression increased significantly (p<0.01), while the cell proliferation decreased. (4) In preliminary study on the relation of surface property and phospholipase, PLD activity was increased but $PLA_2$ activity did not changed according to applied voltage. Conclusion. The anodized titanium shows improved surface characteristics than the machined titanium. The surface properties acquired by anodization appear to give rise more mature osteoblast characteristics and might result in increased bone growth, and contribute to the achievement of a tight fixation. The precise mechanism of surface property signaling is not known, may be related to phospholipase D.

WETTABILITY AND DRUG DELIVERY OF FUNCTIONALLY GRADED NANO-MICRO POROUS TITANIUM SURFACE

  • Yun, Kwi-Dug;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.307-319
    • /
    • 2008
  • STATEMENT OF PROBLEM: It is known that an anodic oxidation technique, one of the methods for the implant surface treatment, remarkably increased surface area, enhanced wettability and accelerated the initial bone healing. Purpose: This study was performed to evaluate the wettability of anodized titanium surface which has a nanotubular structure, to assess osseointegration after the placement of implant with nano-size tubes on tibia of rats and to analyze quantitatively transferable rhBMP-2 on each surface. MATERIAL AND METHOD: Four different kinds of surface-treated titanium discs (polished (machined surface) group, micro (blasting surface) group, nano (anodizedmachined surface) group, and nano-micro (anodized-blasting surface) group) were fabricated (n=10). Three different media were chosen to measure the surface contact angles; distilled water, plasma and rhBMP-2 solution. After a single drop (0.025 $m{\ell}$) of solution, the picture was taken with the image camera, and contact angle was measured by using image analysis system. For the test of osseointegration, 2 kinds of anodized surface (anodized-machined surface, anodized-blasting surface) implants having 2.0 mm in diameter and 5.0 mm in length inserted into the tibia of Wistar rats. After 3 weeks, tibia were harvested and the specimens were stained with hematoxylin and eosin for histological analysis. To test the possibility of drug delivery, after soaking sample groups in the concentration of 250 ng/$m{\ell}$l of rhBMP-2 for 48 hours, the excess solution of rhBMP-2 were removed. After that, they were lyophilized for 24 hours, and then the rhBMP-2 on the surface of titanium was resolved for 72 hours in PBS. All the extracted solution was analyzed by ELISA. One-way analysis of variance (ANOVA) was performed on the data. RESULTS: The wettability is improved by anodic oxidation. The best wettability was shown on the nano-micro group, and it was followed by nano group, micro group, and polished group. In the histological findings, all implants showed good healing and the new bone formation were observed along the implant surface. After 3 days, nano-micro group delivered the most amount of rhBMP-2, followed by nano group, micro group, and polished group. CONCLUSION: It indicated that anodic oxidation on blasting surface produce functionally graded nano-micro porous structure and enhance hydrophilicity of the surface and osseointegration. The findings suggest that the nano-micro porous structure could be a useful carrier of osteogenic molecules like rhBMP-2.

골내낭에 매식된 수종의 생체요법재료에 대한 조직학적 연구 (Histologic Study Of Different Bioceramic Implants In Intrabony Defects)

  • 이철우;최상묵;한수부;박상현;김현종
    • Journal of Periodontal and Implant Science
    • /
    • 제26권1호
    • /
    • pp.27-46
    • /
    • 1996
  • The purpose of this study was designed to compare with the effects of 4 different surface active bioceramics on the healing process of alveolar bone defects in dogs. Artificial alveolar bone defects depth 4-6mm, width 3-4mm) were created with # 6 round bur at interproximal areas of maxillary canine, maxillary 2nd premolar, mandibular canine, and mandibular 3rd premolar. porous hydroxyapatite(Interpore $200^R$) , 45S5 bioglass, CJ4/lOC crystalline glass, and JJ crystalline glass were implanted in intrabony defects randomly. Experimental groups were divided into 4 categories according to its implant material. After implantation, all groups were examined postoperatively 4 weeks to 12 weeks. 3 dogs was selected randomly and sacrificed after vascular perfusion with 2.5% glutaraldehyde at every 4 weeks. Tissue blocks with surroundig alveolar bone and soft tissues were removed and immersed in formaldehyde/glutaraldehyde fixative. After 20 weeks decalcification with EDTA and formic acid, sections were made and observed under light microscope and transmission electron microscope. In all experimental groups, the encapsulation of inactive connective tissue was observed around graft particles in 4 weeks. As time elapsed, the thickness of surrounding connective tissue was decreased. Osteoconductive bone growth pattern was seen apparently in all groups. CJ4/lOC crystalline glass showed the most active bone formation until 8 weeks. 45S5 bioglass was, however, the most active in new bone formation at 12 weeks. Though there was difference in resorption rate among grafting materials, the size of graft particles was decreased gradually. 45S5 bioglass was resorbed faster than the others. On the other hand, porous hydroxyapatite was degraded most slowly. Phagocytosed particulate matters was observed in the cytoplasm of multinuclear multinuclear giant cell and macrophage under transmission electron microscope. The results suggested suggested that 45S5 bioglass and CJ4/lOC crystalline glass may have some enhanced reparative potential when compared to porous hydroxapatite in the treatment of periodontal defeds. JJ crystalline glass reguires a further investigation of the safety of its use.

  • PDF

인체 삽입형 자기 공진 무선전력전송 수신기 설계 및 성능 분석 (Design and Performance Analysis of Magnetic Resonant Wireless Power Transfer Receiver for Implant Medical Device)

  • 김성재;구현철
    • 한국전자파학회논문지
    • /
    • 제29권12호
    • /
    • pp.935-941
    • /
    • 2018
  • 본 논문에서는 소형의 인체 삽입형 의료기기에 자기 공진기법 무선전력전송을 적용하는 경우, 적합한 시스템 구성을 제안하고 성능을 검증하였다. 제안하는 수정된 직렬-병렬 구성은 전력 수신부의 전력 수신 코일과 커패시터를 병렬로 연결한 공진기에 직렬로 연결되는 인덕터를 추가하여 구현하며, 낮은 인덕턴스를 가진 전력 수신 코일을 이용하는 경우 직렬 공진기를 이용하는 경우에 비해 높은 효율을 달성할 수 있다. 회로분석을 통해 해당 구성의 유효성 및 동작조건을 이론적으로 검증하고, 돼지 지방 및 근육 생체 블록에 무선전력전송 수신코일을 삽입한 환경에서 무선전력전송을 진행하여 전력 전송 효율 및 생체 블록의 온도 변화를 측정 비교하였다. 생체 블록에 2.5~10 mm 깊이로 삽입 시 제안한 구성이 일반적인 직렬-직렬 구성보다 평균 17.79 % 개선된 효율을 보이며, 공기 중에서 32 dBm 전력 송신 시 직렬-직렬 수신 코일은 평균 $0.75^{\circ}C/s$, 제안한 구성의 수신 코일은 평균 $0.18^{\circ}C/s$의 온도 변화를 보여 제안한 구성이 인체 삽입형 무선전력전송 시스템 구성에 보다 적합함을 확인하였다.

컴퓨터단층촬영검사에서 고관절 삽입물에 의한 영상평가 (Image Evaluation by Metallic Hip Prosthesis in Computed Tomography Examination)

  • 민병인;임인철
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.281-288
    • /
    • 2022
  • 본 연구에서는 고관절에 금속삽입물(Metal implant)이 삽입되어 있는 환자를 대상으로 일반적인 CT검사(Before MAR) 영상과 MAR을 사용하여 얻어진(After MAR) 영상을 4개의 알고리즘(Soft, Standard, Detail, Bone)에 적용하여 Noise, SNR, CNR을 비교 분석하여 정량적 평가로 최적의 알고리즘을 알아보고자 하였다. 분석방법으로는 4개의 알고리즘으로 재구성한 영상에 이미지 분석과 영역 및 픽셀값을 계산할 수 있는 Image J 프로그램을 사용하였다. Noise, SNR, CNR을 구하기 위해 측정부위를 영상에서 금속삽입물이 가장 인접해 있는 Bone(궁둥뼈, ischium)을 지정하여 HU mean값과 HU SD값을 구하고 배경잡음(Background)은 주위 근육으로 하였다. 관심영역(region of interest, ROI)은 뼈의 크기를 감안하여 동일하게 15×15 mm로 지정하였으며 SNR과 CNR의 값은 주어진 식에 의거하여 산출하였다. 결과적으로 노이즈는 After MAR, Soft 알고리즘에서 노이즈가 가장 낮게 나타났으며, SNR, CNR은 Before MAR, Soft 알고리즘이 가장 높게 나타났다. 따라서 Soft 알고리즘이 고관절 금속삽입술 CT에 가장 적절한 알고리즘으로 판단된다.

Fabrication of Luminescent Hydroxyapatite Microspheres for Drug Loading and Release

  • Park, So Yeon;Kwon, Seung Lee;Baek, Mi Yeon;Yoo, Jin Sun;Kim, Min-Cheol;Jung, Hyun Suk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.360.1-360.1
    • /
    • 2016
  • Hydroxyapatite (Ca10(PO4)6(OH)2, HAP) particles have attracted a great deal of attention in biomedical fields due to their good biocompatibility, bioactivity and fairly broad applications as drug delivery, dental implant, bone cement, and etc. Thus, many researchers have made an effort to add new functionalities such as luminescence, drug delivery, and bone regeneration properties up to HAP powders by controlling their nanostructure as well as composition. In this research, the mesoporous strontium substituted HAP (Sr-HAP) microspheres were synthesized using a hydrothermal method. In this synthesis, aspartic acid monomers were utilized to form microsphere by controlling surface energy of HAP particles and Sr ions were substituted into Ca ion sites, which induced luminescence property in HAP powders. Moreover, the change in the amount of Sr substitution was found to influence the particle size, morphology, and concurrently surface area, which led to changing drug loading as well as drug release property. The amount of Sr influences the morphology, luminescent properties, particle size, surface area cell viability and drug loading property, which are investigated by SEM, TEM, XRD, FTIR, BET, XPS and in vitro test such as MTT assay and drug release test. In particular, the multifunctional Sr-HAP with molar ratios of 0.25 (Sr/(Ca+Sr)) possessed the strongest luminescent property as well as the superior drug loading and sustained release properties that were correspondent with large surface area and pore size. Our study indicates that the fabricated multifunctional Sr-HAP microspheres are quite useful for bone regeneration and drug delivery.

  • PDF