• Title/Summary/Keyword: implant prosthesis

Search Result 640, Processing Time 0.026 seconds

Implant placement with inferior alveolar nerve repositioning in the posterior mandible

  • Doogyum Kim;Taeil Lim;Hyun-Woo Lee;Baek-Soo Lee;Byung-Joon Choi;Joo Young Ohe;Junho Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.6
    • /
    • pp.347-353
    • /
    • 2023
  • This case report presents inferior alveolar nerve (IAN) repositioning as a viable approach for implant placement in the mandibular molar region, where challenges of severe alveolar bone width and height deficiencies can exist. Two patients requiring implant placement in the right mandibular molar region underwent nerve transposition and lateralization. In both cases, inadequate alveolar bone height above the IAN precluded the use of short implants. The first patient exhibited an overall low alveolar ridge from the anterior to posterior regions, with a complex relationship with adjacent implant bone level and the mental nerve, complicating vertical augmentation. In the second case, although vertical bone resorption was not severe, the high positioning of the IAN within the alveolar bone due to orthognathic surgery raised concerns regarding adequate height of the implant prosthesis. Therefore, instead of onlay bone grafting, nerve transposition and lateralization were employed for implant placement. In both cases, the follow-up results demonstrated successful osseointegration of all implants and complete recovery of postoperative numbness in the lower lip and mentum area. IAN repositioning is a valuable surgical technique that allows implant placement in severely compromised posterior mandibular regions, promoting patient comfort and successful implant placement without permanent IAN damage.

Changes in the fractal dimension of peri-implant trabecular bone after loading: a retrospective study

  • Mu, Teh-Jing;Lee, Dong-Won;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.5
    • /
    • pp.209-214
    • /
    • 2013
  • Purpose: To assess bony trabecular changes potentially caused by loading stress around dental implants using fractal dimension analysis. Methods: Fractal dimensions were measured in 48 subjects by comparing radiographs taken immediately after prosthesis delivery with those taken 1 year after functional loading. Regions of interest were isolated, and fractal analysis was performed using the box-counting method with Image J 1.42 software. Wilcoxon signed-rank test was used to analyze the difference in fractal dimension before and after implant loading. Results: The mean fractal dimension before loading ($1.4213{\pm}0.0525$) increased significantly to $1.4329{\pm}0.0479$ at 12 months after loading (P<0.05). Conclusions: Fractal dimension analysis might be helpful in detecting changes in peri-implant alveolar trabecular bone patterns in clinical situations.

Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant (맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출)

  • Seo, Jeong-Woo;Jun, Yong-Tae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2008
  • Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

Prosthodontic problems and complications associated with osseointegration (임플란트 보철물의 임상적 합병증에 관한 고찰)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.349-357
    • /
    • 2015
  • Edentulous patients with a severely resorbed mandible or maxilla often experience problems with conventional dentures, such as insufficient stability and retention, together with a decrease in chewing ability. Because of the good prognosis of dental implants, these patients can be successfully treated with implant-retained or implant-supported prosthesis. Ideally, a maximum number of implants of maximum length are placed in appropriate surgically prepared sites that are surrounded by a maximum amount of bone of favorable quality. The implants are favorably aligned faciolingually and mesiodistally to enhance optimal prosthodontic design. This article describes the clinical problems and complications encountered when treating a consecutive number of edentulous patients with osseointegrated implant-supported prostheses.

PROSTHETIC REHABILITATION OF THE PARTIALLY EDENTULOUS PATIENT BY USING OSSEOINTEGRATE IMPLANT AFTER REMOVAL OF AMELOBLASTOMA (법랑아세포종 제거후의 Implant보철수복 증례)

  • Ahn, Sang-Hun;Kim, Jong-Pil;Jo, Byung-Woan;Ahn, Jye-Jynn
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.95-102
    • /
    • 1997
  • Ameloblastoma is the most agrressive ofht odontogenic tumors and it arises from the dental lamina or the derivatives of lamina. Ameloblastoma is a benign but locally invasive neoplasm consisting of proliferating odontogenic epithelium lying in a fibrous stroma. Usually the ameloblastomas are diagnosed in the forth and fifth decardes. Over 80% of them occur in the mandible, the remainder in the maxilla. The preferred treatment for ameloblastoma is radical excision, conserving(when possible. the inferior border of the mandible. The functional and esthetic rehabilitation of the partially edentulous patient may prevent the remaining structures from supporting conventional prosthetic treatment. Patients with long edentulous spans, malpositioned teeth, residual ridges defects and high muscle attachments may be offered an osseointegrated fixed prosthesis. Osseointegrated dental implants provide a viable alternative of tooth replacement. This is a case report of 16 year old female with ameloblastoma. We treated patient with radical excision, conserving the inferior border of the mandible and allogenous bone graft. The defected residual ridge area was reconstructed implants(Steri-Oss Implant System). the result was satisfactory.

  • PDF

Esthetic reconstruction of upper central incisor using immediate Frialit-2 implant placement, immediate temporary crown fabrication and IPS Empress 2 crown (즉시 Frialit-2 implant 식립, 즉시 임시치관 제작 그리고 IPS Empress 2 crown을 이용한 상악중절치의 심미적 수복)

  • Kim, Yu-Lee;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • During the past several years, significant advances have occurred in the utilization of osseointegrated implants for the treatment of partially edentulous patients. One of the biggest purposes for treating of these patients is the high demand for improved esthetics, especially in the anterior region. For this esthetics, the new trend in dental implants is the immediate placement and immediate superstructure fabrication. The refined surgical technique, the skillful soft tissue management, and the proper prosthetic coordination are the main factors to achieve natural looking of implant supported prosthesis. The customized provisional restoration and the customized impression coping are recommended for the optimal peri-implant soft tissue contour. The basic concept of Frialit 2 system was the immediate replacement of a tooth with root-analog fixture after extraction. This system guarantees an ideal result in function and esthetics. The ceramic abutment system offers improved quality in the respect of esthetics, fitness, translucency, and biocompatibility. In this clinical report, the final restoration made with IPS Empress 2 crown on the CeraBase abutmen of Frialit 2 system allowed the reproduction of the natural vitality of tooth and adjacent gingiva.

Maxillofacial reconstruction with Medpor porous polyethylene implant: a case series study

  • Khorasani, Mansour;Janbaz, Pejman;Rayati, Farshid
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.3
    • /
    • pp.128-135
    • /
    • 2018
  • Objectives: The role of alloplastic materials in maxillofacial reconstruction is still controversial. Determining the utility of porous, high-density, polyethylene implants as a highly stable and flexible, porous alloplast, with properties such as rapid vascularization and tissue ingrowth, is crucial in cases of maxillofacial deformities and aesthetic surgery. Materials and Methods: Thirty high-density porous polyethylene implants were implanted in 16 patients that had been referred to a private office over a three-year period. These implants were used for correcting congenital deformities, posttraumatic defects and improving the aesthetic in nasal, paranasal, malar, chin, mandibular angle, body and orbital areas. Results: The outcomes of the cases in this study showed good aesthetic and functional results. The majority of patients had no signs of discomfort, rejection or exposure. Two implants suffered complications: a complicated malar implant was managed by antibiotic therapy, and an infected mandibular angle implant was removed despite antibiotic therapy. Conclusion: Based on the results, the Medpor implant seems to be an excellent biomaterial for correcting various facial deformities. Advantages include its versatility and relatively ideal pore size that allows for excellent soft tissue ingrowth and coverage. It is strong, flexible and easy to shape.

THE MANAGEMENT OF A COMPLEX IMPLANT CASE USING CAD-CAM TECHNOLOGY: A CLINICAL REPORT

  • Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.634-638
    • /
    • 2008
  • PURPOSE: The application of computer-aided technology to implant dentistry has created new opportunities for treatment planning, surgery and prosthodontic treatment, but the correct selection and combination of available methods may be challenging in times. Hence, the purpose of this case report is to present a combination of several computer-aided tools as approaches to manage complicated implant case. MATERIAL AND METHODS: A 47 year-old female patient with severe dental anxiety, high expectations, financial restrictions and poor compliance presented for a fixed rehabilitation. A CT scan with a radiographic template obtained with software (SimPlant, Materialize, Leuven, Belgium) was used for treatment planning. The surgical plan was created and converted into a stereolithographic model of the maxilla with bone-supported surgical templates (SurgiGuide, Materialise, Leuven, Belgium), that allowed for the precise placement of 7 implants in a severely resorbed edentulous maxilla. After successful osseointegration, an accurate scan model served as the basis for the fabrication of a one-piece milled titanium framework using the Procera (Nobel Biocare, Gothenburg, Sweden) technology. The final rehabilitation of the edentulous maxilla was rendered in the form of a screw-retained maxillary metal-reinforced resin-based complete prosthesis. RESULTS: Despite challenging circumstances, 7 implants could be placed without bone augmentation in a severely resorbed maxilla using the SimPlant software for pre-implant analysis and the SurgiGuide-system as the surgical template. The patient was successfully restored with a fixed full arch restoration, utilizing the Procera system for the fabrication of a milled titanium framework.

The Clinical Implications of Poly Implant Proth$\grave{e}$se Breast Implants: An Overview

  • Wazir, Umar;Kasem, Abdul;Mokbel, Kefah
    • Archives of Plastic Surgery
    • /
    • v.42 no.1
    • /
    • pp.4-10
    • /
    • 2015
  • Mammary implants marketed by Poly Implant Proth$\grave{e}$se (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Proth$\grave{e}$se", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.

Implant overdenture impressions using a dynamic impression concept

  • Lee, Byung-Kil;Park, Sang-Hun;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.66-70
    • /
    • 2014
  • A dynamic impression is a functional impression that records the functional movement of the patient's own muscle and muscle attachment. This process reduces the number of random factors. This article describes a method for making a special tray using a dynamic impression concept that was made from provisional dentures used for implant healing. The individual tray is used to make a wash-impression to record the features of the mucosa in detail. The main advantage of this technique is that it provides a functional relationship of the implant components to the supporting tissues without overextension because provisional denture had been used for 2 months and the border length of individual tray was nearly the same as that of provisional denture. The delivery of the prosthesis constructed using this impression technique is time-saving because there is no need for border molding and there are fewer post-insertion appliance adjustments.