• Title/Summary/Keyword: implant prosthesis

Search Result 640, Processing Time 0.03 seconds

Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study

  • Leesungbok, Richard;Seo, Jin-Ho;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.163-166
    • /
    • 2018
  • PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.

A HISTOLOGICAL STUDY OF SURROUNDING BONE TISSUE REACTION TO HYDROXY APATITE COATED DENTAL IMPLANT (Hydroxy Apatite가 피복된 치과매식체의 주위골조직 반응에 관한 조직학적 연구)

  • Song, Joon-Ki;Hur, Sung-Joo;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.23-34
    • /
    • 1991
  • Even if we can recover the function of mastication, pronunciation and esthetic using the fixed or removable prosthesis in the loss of teeth or hard tissue in the oral cavity, we use several kinds of implants in order to solve the problem which can be occured when we can't install the denture because of excessive bone resolution or psychlogical affairs. At present Titanium implant plays a major role in this field and has osseointegrated. And the study on the modern material is going on, that result in developing and using the implant which is coated with HA, bone induced material. In this, I studied histologically the change of the bone tissue which is occured when three kinds of HA coated implants. Such as Integral, Sustain, Biovent implanted into mandible of dog and got a 8-weeks healing period. I got the conclusion as follows: 1. Most of the implant which is covered with serveral kinds of HA coating implant in bone after 8 weeks being implanted and has osseointegrated, partially converted into the connective tissue. 2. Biovent formed the connective tissue in the perforated area of inferior alveolar canal and has osseointegrated.

  • PDF

A VITRO STUDY OF RETAINED SCREW STABILITY BY VARIOUS CONNECTION DESIGNS BETWEEN FIXTURE AND ABUTMENT IN IMPLANT DENTISTRY (임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구)

  • Yang Jae-Sik;Vang Mong-Sook;Jo Gyu-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.83-93
    • /
    • 2004
  • Statement of problem : Since the concept of osseointegrated dental implant by $Br{\aa}nemark$ et al was first applied to mandibular full edentulous patients. Recently it is considerated the first treatment option on missing teeth. A common problem associated with dental implant restorations is loosening of screws that retain the prosthesis to the abutment and the abutment to the implant fixture. Purpose : This study is to examine the influence on screw loosening of implant-abutment designs. Material and methods : External hex, cone screw, beveled hex, cam cylinder, cylinder hex by means of evaluating the loosening torques, with respect to a range of tightening torques after repeated loading. Result : 1. Cone screw, beveled hex groups are the highest initial tightening rate and cylinder hex, external hex groups are the lowest initial tightening rate (p < 0.05). 2. Cone screw groups are the highest after repeated loading tightening rate and cylinder hex groups are lowest after repeated loading tightening rate(p < 0.05). 3. Cone screw groups have the highest initial stability and anal stability. 4. All groups are decreased tightening rate after repeated loading.

Clinical study on the comparison of gold and zirconia wear in an implant-supported fixed prosthesis (임플란트 지지 고정성 보철물에서 금과 지르코니아의 마모 비교에 대한 임상 연구)

  • Kim, Jee-Hwan;Yang, Seung-Won;Oh, NamSik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.252-259
    • /
    • 2017
  • Purpose: The purpose of this study was to compare and analyze the wear of a prosthesis for 6 months after restoration with implant-supported fixed dental prosthesis made of either zirconia or gold. Materials and Methods: This study was conducted on patients requiring implant-supported fixed dental prostheses on first or second molar from January, 2015 to January, 2016. A total of 47 prostheses and antagonists were examined. Occlusal surface was recorded by impression of each prosthesis and antagonist 1 week and 6 months after prosthesis delivery. The digital files were created by impression scan. Occlusal shapes of 1 week and 6 months were compared and wear of prostheses and antagonists was analyzed. The Mann-Whitney test was used to analyzed the result data underwent normality test using SPSS (Version 23.0, IBM Corporation) Results: Mann-Whitney test revealed that there was no statistically significant difference in the median amount of mean vertical wear for 6 months in zirconia ($50.84{\mu}m$) and gold ($42.84{\mu}m$) prostheses (P > 0.05). When the opposing teeth were natural, the median amount of mean vertical wear of zirconia and gold prostheses was $47.72{\mu}m$ and $41.97{\mu}m$, respectively, and the median amount of mean vertical wear of enamel was $47.26{\mu}m$ and $44.59{\mu}m$, respectively. Statistical analysis showed no significant difference (P > 0.05). Conclusion: Despite the short study period and the small number of experimental groups, zirconia and gold showed no significant difference in wear during the first 6 months. Opposing natural enamel also showed no significant difference in the wear.

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

Clinical Evaluation about the Immediate Implant Replacement after Tooth Extraction (발치 직후 시행된 즉시 임플란트 식립술에 관한 임상적 평가)

  • Yang, Eun-Young;Chun, Sang-Deuk;Rho, Jae-Hwan;Lee, Seung-Eun;Song, Jae-Chul;Chin, Byung-Rho
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 2003
  • Background: Immediate implant placement has become an acceptable treatment for the edentulous area. The advantages of the immediate implant placement include considerable decrease in time from tooth extraction to placement of the finial prosthesis, fewer surgical procedures, and better acceptance of the overall treatment plans. But the success is dependent on the quantity and quality of the extraction socket. The purpose of this study is to evaluate the success of the immediate implant placement. Materials and Methods: Twenty-one sites in 16 patients were selected for the evaluation of the immediate implant placement. All of the cases were followed using clinical and radiographic examinations. Criteria of success were the absence of peri-implant radiolucency, mobility, and persistent pain or sign of infection. Results: Of the 21 implants, 13 implants have been succeeded. Of the 13 implants, 10 implants were replaced for the periodontal disease and 3 implants were replaced for the trauma. Conclusion: The criteria of the success in immediate implant placement are as follows. 1) Implants placed into fresh extraction sockets have a high rate of survival. 2) Implant should be placed as close as possible to the alveolar crest. 3) Implant placed into available bone beyond the apex have a high success rate.

  • PDF

Implant success rates in full-arch rehabilitations supported by upright and tilted implants: a retrospective investigation with up to five years of follow-up

  • Francetti, Luca;Rodolfi, Andrea;Barbaro, Bruno;Taschieri, Silvio;Cavalli, Nicolo;Corbella, Stefano
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.6
    • /
    • pp.210-215
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to investigate the cumulative success rate, the implant survival rate, and the occurrence of biological complications in implants supporting full-arch immediately loaded rehabilitations supported by upright and tilted implants. Methods: The clinical records and periapical radiographs of patients who attended follow-up visits were collected, and information was recorded regarding marginal bone loss resorption, the occurrence of peri-implant infectious diseases, and the implant survival rate. Implants were classified as successful or not successful according to two distinct classifications for implant success. Results: A total of 53 maxillary and mandibular restorations including 212 implants were analysed, of which 56 implants were studied over the full five-year follow-up period. After five years, the cumulative success rate was 76.04% according to the Misch classification and 56.34% according to the Albrektsson classification. The cumulative implant survival rate was 100%, although one implant was found to be affected by peri-implantitis at the second follow-up visit. Conclusions: The cumulative success rate of the implants dropped over time, corresponding to the progression of marginal bone resorption. The prevalence of peri-implantitis was very low, and the implant survival rate was not found to be related to the cumulative success rate.

HISTOMORPHOMETRIC AND REMOVAL TORQUE VALUES COMPARISION OF ROUGH SURFACE TITANIUM IMPLANTS (임프란트 표면처리 방법에 따른 골유착의 조직계측학적 분석 및 제거회전력 비교 연구)

  • Lee, Sang-Chul;Song, Woo-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.396-405
    • /
    • 2001
  • Osseointegrated implants are used for the fixation of dental prosthesis with good long-term clinical results. In an attempt to improve the quantity and quality of the bone-implant interface, numerous implant modification have been used. Implants surface modifications have been used such as titanium-plasma sprayed, hydroxyapatite-coating, sandblasted, sandblasted and acid-etched, acid-etched. Rough surface implants have greater implant surface area and enhance the bone-implant interface and improve stabilization. The purpose of present study was to evaluate light microscopic and scanning microscopic examinations and removal torque value of newly developed calcium phosphate blast and acid-etched implant in the femur of rabbits. Titanium plasma sprayed(TPS) implant served as controls. After 12 weeks of healing of the femurs of 12 rabitts, the implant-containing segments of femur were removed on bloc and bone block including sections. Histologic examination and histomorphometric and removal torque values comparision were made for two implants. Obtained results are follows: 1. Newly developed calcium phosphate blasted and acid-etched implants were in close contact with bone under light microscopic examinations. 2. New implants showed mean bone-to implant contact 59.8%, whereas TPS implants showed mean bone-to implant contact 54.5% (statistically no difference p<0.05). 3. New implants showed mean bone density 56.7%, whereas TPS implants showed mean bone density 49.2% (statistically difference p<0.05). 4. New implants demonstrated mean removal torque values 40.5Ncm, whereas the mean removal torque values of TPS implants ranged 39.3Ncm. No statistical differences(p<0.05) were observed between two groups of implants nor was there any difference between the two implants at the clinical level.

  • PDF

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

A COMPARISON OF THE MASTICATORY FUNCTION BETWEEN TWO DIFFERENT TYPES OF IMPLANT SUPPORTED PROSTHESES AND COMPLETE DENTURE FOR FULLY EDENTULOUS PATIENTS

  • Lee, Jae-Hoon;Kim, Woo-Hyun;Shin, Rie-Hye;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.591-601
    • /
    • 2008
  • STATEMENT OF PROBLEM: The improvement in oral function and comfort from the dental implant appears to depend on the particular type of implant support used with the denture. The number and positioning of implants have an influence on the force transfer and subsequent stress distribution around implants. Nevertheless, a quantitative comparison has not been made between the types of implant prosthesis used with different materials compared to conventional complete denture. PURPOSE: The objective of this study is to assess the masticatory performance, bite force and impact of two different type of implant supported prostheses on oral health-related quality of life compared to conventional complete denture with GOHAI, validated oral-specific health status measures, the sieving method, and the Prescale Dental System. MATERIAL AND METHODS: From the years 1999 to 2006, a total of 30 completely edentulous patients in a single arch were selected from the Yonsei University Dental Hospital, Department of Prosthodontics and Implant Clinic in Seoul, S. Korea. Patients were divided into 3 groups of 10 each. Group HR was restored with fixed-detachable hybrid prostheses with resin teeth. Group FP had fixed dentures with porcelain teeth while Group CD had a complete denture. The masticatory performance was compared between 3 groups. RESULTS: The results showed a significant improvement in oral health-related quality of life with dental implants compared to a conventional denture in GOHAI comparison. Overall, implant prostheses showed a higher masticatory performance ($S_{50}$) and maximum bite force compared with conventional dentures (P < .05) but no differences between different implant supported prostheses (P > .05). CONCLUSION: Within the limitation of this study, the numbers of implant and material of implant prostheses does not appear to impact patient satisfaction, masticatory performance or bite force.