• 제목/요약/키워드: implant prosthesis

검색결과 639건 처리시간 0.023초

임플랜트-지대주의 연결방법에 따른 임플랜트 보철의 유한요소 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO CONNECTION TYPES OF IMPLANT-ABUTMENT)

  • 허진경;계기성;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.544-561
    • /
    • 2005
  • Purpose : This study was to assess the loading distributing characteristics of implant systems with internal connection or external connection under vertical and inclined loading using finite element analysis. Materials and methods : Two finite element models were designed according to type of internal connection or external connection The crown for mandibular first molar was made using cemented abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the centric cusp tip in a 15$^{\circ}$ inward inclined direction (loading condition B), or 200N at the centric cusp tip in a 30$^{\circ}$ outward inclined direction (loading condition C) respectively. Von Mises stresses were recorded and compared in the supporting bone, fixture, abutment and abutment screw. Results : 1. In comparison with the whole stress or the model 1 and model 2, the stress pattern was shown through th contact of the abutment and the implant fixture in the model 1, while the stress pattern was shown through the abutment screw mainly in the model 2. 2. Without regard to the loading condition, greater stress was taken at the cortical bone, and lower stress was taken at the cancellous bone. The stress taken at the cortical bone was greater at the model 1 than at the model 2, but the stress taken at the cortical bone was much less than the stress taken at the abutment, the implant fixture, and the abutment screw in case of both model 1 and model 2. 3. Without regard to the loading condition, the stress pattern of the abutment was greater at the model 1 than at the model 2. 4. In comparison with the stress distribution of model 1 and model 2, the maximum stress was taken at the abutment in the model 1. while the maximum stress was taken at the abutment screw in the model 2. 5. The magnitude of the maximum stress taken at the supporting bone, the implant fixture, the abutment, and the abutment screw was greater in the order of loading condition A, B and C. Conclusion : The stress distribution pattern of the internal connection system was mostly distributed widely to the lower part along the inner surface of the implant fixture contacting the abutment core through its contact portion because of the intimate contact of the abutment and the implant fixture and so the less stress was taken at the abutment screw, while the abutment screw can be the weakest portion clinically because the greater stress was taken at the abutment screw in case of the external connection system, and therefore the further clinical study about this problem is needed.

다수의 임플란트발거로 임플란트 고정성 보철이 실패한 환자에서의 잔존 임플란트를 이용한 부분 가철성 국소의치 수복증례 (Case report: Application of Implant Supported Removable Partial Denture due to Multiple Dental Implant Loss of the Fixed Implant Supported Prosthesis)

  • 강정경;남기훈
    • 대한심미치과학회지
    • /
    • 제23권1호
    • /
    • pp.34-40
    • /
    • 2014
  • 부분 무치악을 수복하는 데 있어서 선택할 수 있는 치료의 옵션으로는 전통적인 국소의치와 임플란트 지지-고정성 보철물 등이 있다. 하지만, 환자의 전신적 또는 구강의 상태(수술적인 술식이 제한되는 전신병력, 지지조직의 부족 그리고 골유착에 실패한 임플란트)와 치료비용에 대한 허용 정도에 따라 모든 옵션이 항상 가능한 것은 아니다. 가철성 국소의치는 임플란트 고정성 보철물에 비해 구강위생 관리 및 상,하악 악간관계의 부조화를 수정하기에 편리한 장점이 있다. 최근에는 전략적 위치에 임플란트를 식립하여 기존 악궁 형태에서는 제한되는 국소의치 디자인의 한계를 개선할 수 있는 임플란트지지형 RPD(Implant Supported Removable Partial Denture)가 새로운 방안으로 대두되고 있다. ISRPD는 전략적 위치에 임플란트를 식립하여 역학적인 한계를 극복할 수 있을 뿐 만 아니라 전악의 임플란트지지형 고정성 보철이 제한되는 환자에서 보다 경제적이고 현실적인 보철적 해결책이 될 수 있다. 따라서, RPD를 이용한 보철계획 수립시 전략적 위치에서의 임플란트의 사용은 고전적인 가철성 국소 의치에서보다 유지력과 안정성을 증진시키고 구강위생관리 또한 용이하여 환자의 적응도를 높이는 방안으로 고려될 수 있다. 본 증례는 상악 양측 구치부의 임플란트 고정성 보철,하악의 bar-type overdenture를 사용중이던 59세 남성환자에서 상악 #15i임플란트의 abutment screw fracture와 임플란트의 골유착 실패로 인한 다수 임플란트를 발거 후 남은 #15i,24i,25,26,i의 잔존 임플란트와 #23 자연치를 활용해 상악에 ISRPD를 적용한 경우이다. #23 surveyed crown, #24i=25i=26i surveyed bridge 및 #15i에 gold coping을 제작하여 국소의치의 지지와 유지,안정을 도모하였다.최종 보철물을 장착하고 2년간 주기적인 follow up 통해 예후를 관찰중이며 지대치로 사용한 임플란트에서 screw loosening이나 파절, 골흡수 등의 증상은 현재까지 관찰되지 않았다.

과도한 치관높이 공간을 가진 환자에서 유지관리를 고려한 임플란트 수복증례 (Implant restoration considering maintenance for a patient with excessive crown height space)

  • 마주리;양홍서;박상원;임현필;윤귀덕;방몽숙
    • 대한치과보철학회지
    • /
    • 제51권2호
    • /
    • pp.107-112
    • /
    • 2013
  • 치관높이 공간이 과도할 경우 임플란트 몸체 혹은 구성물의 실패와 같은 고정성 보철물의 생역학적 합병증이 증가하며 치관 높이 공간이 12 mm 이상으로 과도한 경우는 고정성 보철물 선택에 유의하여야 한다. 고정성 보철물을 제작 시 치아들이 길어지므로 심미적 부위에서는 치은 색조를 띠는 재료를 사용해야 할 필요가 있다. 이러한 경우, 유지와 위생 관리가 적절하지 못하게 형성된 고정성 보철물은 음식물, 치태, 치석을 정체시키고 염증과 감염이 발생될 수 있으며 만성 염증과 감염으로 인해 외과적인 개선이 필요할 수 있다. 본 증례에서, 과도한 치관높이 공간을 가진 환자에게 발음 및 심미성을 고려하여 보철물 제작 후 보철물 주위의 치은 염증 및 부종이 발생하였으며, 그 원인이 구강위생을 어렵게 하는 보철물의 디자인으로 판단되어 치간공극을 충분히 형성한 임시 보철물을 장착 후 2개월 동안의 관찰 기간을 거치며 특이할 만한 이상 소견이 없음을 확인하였고 자가 위생 관리가 용이한 디자인으로 지르코니아 하부구조에 도재를 축성한 고정성 보철물로 구강회복을 시행하였으며, 일련의 치료과정을 통하여 부적절한 연조직 반응이 관찰 되지 않고 기능적인 면에서 만족스러운 결과를 얻을 수 있었다.

Autogenous fresh demineralized tooth graft prepared at chairside for dental implant

  • Kim, Eun-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.8.1-8.6
    • /
    • 2015
  • Background: This study aimed to evaluate the clinical usefulness of autogenous fresh demineralized tooth (auto-FDT) graft prepared at the chairside for alveolar bone grafting during dental implant surgery. Methods: In total, 38 patients requiring both tooth extraction (for endodontic or periodontal reasons or third molar extraction) and alveolar bone regeneration for dental implant placement were included. Within 2 h after clean extraction, the teeth were prepared at the chairside to serve as bone graft material. In the same sitting, blocks or chips of this graft material were used to reconstruct defects at the osteotomy site simultaneously with or before implant placement. Twelve months after prosthesis fabrication and placement, the clinical findings and implant success rates were evaluated. Histological studies were randomly conducted for selected cases. Results: Clinical evaluation showed favorable wound healing with minimal complications and good bone support for the implants. No implant was lost after 12 months of function following prosthetic rehabilitation. Histological examination revealed new bone formation induced by the graft material. Conclusions: Chairside preparation of autogenous fresh demineralized teeth after extraction can be a useful alternative to the use of autogenous bone or other graft materials for the immediate reconstruction of alveolar bone defects to facilitate subsequent implant placement.

골융합 임플란트 개발을 위한 동물임상실험;비글견 경골 적용 (Clinical animal test for development of osseointegration implant;application for beagle tibia)

  • 최경주;김신기;문무성;안재용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1373-1377
    • /
    • 2003
  • Current prostheses for amputees are generally extrinsic wearing socket type that the coupling between body stump and appliance wraps the soft tissue and this structure causes several problems :applying direct weight to soft tissue such as skin and muscle, skin trouble of contacting area and pain. In this study, osseointegration implant is a method to directly connect prosthesis to the residual stump skeletal tissue of arm, finger and leg through surgical operation. Technology presented in this paper essentially solves the problems of pain and abnormal weight transfer system indicated above and recovers the functions of the amputated arm and leg. In this paper, implant shape was designed for the first step for the development of osseointegration implant and then we studied the possibility to apply this osseointegration implant to human body by performing implant insertion operation to beagle tibia for the clinical animal test and normal beagle's gait analysis was executed in order to quantitatively verify the beagle's skeletal functions after the implant insertion.

  • PDF

치과기공사국가시험 문항개발기준안연구 (Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician)

  • 이덕혜;정인성;한창식
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF

Comparative clinical study of the marginal discrepancy of fixed dental prosthesis fabricated by the milling-sintering method using a presintered alloy

  • Kim, Mijoo;Kim, Jaewon;Mai, Hang-Nga;Kwon, Tae-Yub;Choi, Yong-Do;Lee, Cheong-Hee;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.280-285
    • /
    • 2019
  • PURPOSE. The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS. Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (${\alpha}=.05$). RESULTS. Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION. The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.

구치부 심미수복, 풀지르코니아 크라운의 파절원인과 그 해결방안 (Factors affecting fracture of full contour monolithic zirconia dental prosthesis in laboratory process)

  • 이수영
    • 대한심미치과학회지
    • /
    • 제23권2호
    • /
    • pp.77-79
    • /
    • 2014
  • There are several factors affected fractures of full contour zirconia (FCZ) dental prosthesis in laboratory process. First, residual moisture can cause zirconia cracks. Complete dry is requisite before zirconia sintering to prevent zirconia cracks. Second, slow cooling rate is essential to prevent cracks during zirconia sintering process. Cracks in bridge pontic area, thick dental implant prosthesis can be prevented by slow cooling rate such as 3 degree Celsius per minute during zirconia sintering. Third, slow heating rate and slow cooling rate during staining and glazing procedure is necessary to inhibit thermal shock of sintered dental zirconia. Lower preheat temperature of porcelain furnace is recommended. Finally, using diamond disc to open embrasure can lead cracks.

상악 임플란트 피개의치에서 임플란트 보조 국소의치로의 전환: 증례보고 (Conversion of implant overdenture to an implant assisted removable partial denture in maxilla: case report)

  • 조성수;송민규;허윤혁;박찬진;조리라;고경호
    • 대한치과보철학회지
    • /
    • 제62권1호
    • /
    • pp.54-63
    • /
    • 2024
  • 장기간 사용된 임플란트 피개의치는 부착장치의 마모와 전치부 교합집중, 인공치 파절, 의치의 회전 등을 보일 수 있다. 이러한 문제점은 추가적인 임플란트 식립을 이용한 임플란트보조 국소의치(IARPD, implant assisted removable partial denture)로의 전환으로 개선할 수 있다. 본 증례는 임플란트 피개의치를 사용하는 3급 악간관계 환자에서 전치부에 집중된 교합을 분산하고 의치의 회전방지를 위해 서베이드 크라운을 이용한 IARPD으로 전환하였다. 여러 단계의 임시수복물을 통해 적절한 기능과 심미를 가진 최종보철물의 형태를 결정하였으며 최종 보철물의 적절한 구치부 교합과 임플란트 주위 변연골 유지를 보였기에 이를 보고하는 바이다.

Bone-level implants placed in the anterior maxilla: an open-label, single-arm observational study

  • Gao, EnFeng;Hei, Wei-Hong;Park, Jong-Chul;Pang, KangMi;Kim, Sun Kyung;Kim, Bongju;Kim, Soung-Min;Lee, Jong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제47권5호
    • /
    • pp.312-327
    • /
    • 2017
  • Purpose: This study assessed marginal bone remodeling and soft tissue esthetics after the loading of single bone-level implants in the anterior maxilla. Methods: An open, single-arm observational clinical trial with 3 years of follow-up was performed, including 22 implants. The patients presented with a single tooth gap in the anterior maxilla (tooth positions 14-24), with natural or restored adjacent teeth. An implant was placed at least 8 weeks post-extraction and healed submerged for 6 weeks. After the second-stage operation, a fixed provisional prosthesis was provided. The final restoration was placed 6 months after the provisional restoration. The time of the provisional crown connection was considered to be the baseline in this study. Esthetic parameters and the marginal bone level were assessed at 6, 12, 24, and 36 months. Results: All implants were well integrated in the bone. A statistically significant increase was found in the mean implant stability quotient between the time of the provisional prosthesis and the time of the final prosthesis. Most implants (95.5%) revealed marginal bone resorption (<0.5 mm), and just 1 implant (4.5%) showed a change of 2.12 mm from baseline to 36 months (mean $0.07{\pm}0.48mm$), while the crestal bone level decreased significantly, from $2.34{\pm}0.93mm$ at baseline to $1.70{\pm}1.10mm$ at 36 months. The facial gingival margin and papilla were stable and the esthetic scores indicated high patient and dentist satisfaction. Conclusions: Platform-switching bone-level implants placed in maxillary single-tooth gaps resulted in successful osseointegration with minimal marginal bone resorption. The peri-implant soft tissue was also esthetically satisfying and stable.