• Title/Summary/Keyword: implant planning

Search Result 190, Processing Time 0.023 seconds

DENTAL IMPLANT TREATMENT WITH ILIAC BONE GRAFT VIA TWO-STAGE APPROACH FOR AVULSED ALVEOLAR BONE DEFECTS; CASE REPORT (외상성 치조골 상실 후 장골 이식을 동반한 이회법 임플란트 치료; 증례보고)

  • Choi, Young-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.386-390
    • /
    • 2007
  • This is about the case of loss of multiple teeth and alveolar bone caused by trauma, which needed alveolar bone augmentation before implant treatment. Alveolar bone was reconstructed using iliac bone graft, and thereafter first implant surgery was followed by consolidation period of 3 months. Iliac bone resorption was observed at the time of implant placement. And that resorption was more in the horizontal dimension than in the vertical. We conclude that additional treatment planning(e.g. using alveolar distraction osteogenesis or tissue expander) should be considered besides bone graft for vertical alveolar bone augmentation. For both maxilla and mandible, prosthodontic treatment was carried out $4{\sim}5$ months after implant placement. To compensate alveolar bone deficiency, partial hybrid overdenture on maxilla and implant-supported fixed bridge on mandible were fabricated, and the total treatment was finished.

CBCT analysis of three implant cases for treatment planning (임플란트 치료 전 CBCT 영상분석 세 증례)

  • Kim, Jae-Duk;Kim, Kwang-Won;Lim, Sung-Hoon
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.171-180
    • /
    • 2007
  • The role of radiographic imaging in determining the size, numbers and the position of implants is very important. To perform the implant procedure, the dentist needs to evaluate the bone pathology and bone density, and to know the precise height, width, and contour of the alveolar process, as well as its relationship to the maxillary sinus and mandibular canal. The author analyzed 3 implant cases for treatment planning with the cone beam CT. All axial, panoramic, serial and buccolingual-sectioned images of 3 cases with stent including vertical marker were taken by using Mercuray (Hitachi, Japan). When the curved line drawn intentionally did not include dot image of a vertical marker on the axial image of CBCT, the image of the vertical marker was deformed on its buccolingually sectioned image. There was wide discrepancy in inclination between the alveolar bone and tooth on buccolingually sectioned image.

  • PDF

Analysis of the priority of anatomic structures according to the diagnostic task in cone-beam computed tomographic images

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.46 no.4
    • /
    • pp.245-249
    • /
    • 2016
  • Purpose: This study was designed to evaluate differences in the required visibility of anatomic structures according to the diagnostic tasks of implant planning and periapical diagnosis. Materials and Methods: Images of a real skull phantom were acquired under 24 combinations of different exposure conditions in a cone-beam computed tomography scanner (60, 70, 80, 90, 100, and 110 kV and 4, 6, 8, and 10 mA). Five radiologists evaluated the visibility of anatomic structures and the image quality for diagnostic tasks using a 6-point scale. results: The visibility of the periodontal ligament space showed the closest association with the ability to use an image for periapical diagnosis in both jaws. The visibility of the sinus floor and canal wall showed the closest association with the ability to use an image for implant planning. Variations in tube voltage were associated with significant differences in image quality for all diagnostic tasks. However, tube current did not show significant associations with the ability to use an image for implant planning. conclusion: The required visibility of anatomic structures varied depending on the diagnostic task. Tube voltage was a more important exposure parameter for image quality than tube current. Different settings should be used for optimization and image quality evaluation depending on the diagnostic task.

The angulation and the position change of the planned implant after tomographic imaging (단층촬영상에서 계획된 임플랜트 매식 각도 및 위치에 대한 스텐트 핀의 상대적 각도 및 위치에 대한 평가)

  • Kang, Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.127-131
    • /
    • 2007
  • Purpose: To measure the differences of the splint pin angulation and the position of the planned implant site after conventional tomographic analysis. Materials and Methods: The angulation and the location of the metal splint pin retained in acrylic stent were compared with the corrected angulation and the location of the implant fixture on the 331 tomographic images. Results: The stent pins were located buccal in 40%, lingual in 10% to the corrected implant site after analysis of the conventional tomographic image. The angle and the location of the maxillary splint pin were mainly directed buccal on incisor and canine regions. The angle and the location of the splint pins in premolar and molar regions needed less corrections in both maxilla and mandible. Conclusions: This study demonstrated that the use of tomographs was essential for successful dental implant planning.

  • PDF

THE MANAGEMENT OF A COMPLEX IMPLANT CASE USING CAD-CAM TECHNOLOGY: A CLINICAL REPORT

  • Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.634-638
    • /
    • 2008
  • PURPOSE: The application of computer-aided technology to implant dentistry has created new opportunities for treatment planning, surgery and prosthodontic treatment, but the correct selection and combination of available methods may be challenging in times. Hence, the purpose of this case report is to present a combination of several computer-aided tools as approaches to manage complicated implant case. MATERIAL AND METHODS: A 47 year-old female patient with severe dental anxiety, high expectations, financial restrictions and poor compliance presented for a fixed rehabilitation. A CT scan with a radiographic template obtained with software (SimPlant, Materialize, Leuven, Belgium) was used for treatment planning. The surgical plan was created and converted into a stereolithographic model of the maxilla with bone-supported surgical templates (SurgiGuide, Materialise, Leuven, Belgium), that allowed for the precise placement of 7 implants in a severely resorbed edentulous maxilla. After successful osseointegration, an accurate scan model served as the basis for the fabrication of a one-piece milled titanium framework using the Procera (Nobel Biocare, Gothenburg, Sweden) technology. The final rehabilitation of the edentulous maxilla was rendered in the form of a screw-retained maxillary metal-reinforced resin-based complete prosthesis. RESULTS: Despite challenging circumstances, 7 implants could be placed without bone augmentation in a severely resorbed maxilla using the SimPlant software for pre-implant analysis and the SurgiGuide-system as the surgical template. The patient was successfully restored with a fixed full arch restoration, utilizing the Procera system for the fabrication of a milled titanium framework.

Development of an evidence-based clinical imaging diagnostic guideline for implant planning: Joint recommendations of the Korean Academy of Oral and Maxillofacial Radiology and National Evidence-based Healthcare Collaborating Agency

  • Kim, Min-Ji;Lee, Sam-Sun;Choi, Miyoung;Ha, Eun Ju;Lee, Chena;Kim, Jo-Eun;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.45-52
    • /
    • 2020
  • Purpose: This study was conducted to develop an evidence-based clinical imaging diagnostic guideline for implant planning, taking into account efficacy, benefits, and risks. Materials and Methods: The guideline development process employed the adaptation methodology used for Korean clinical imaging guidelines(K-CIG). Core databases(Ovid-Medline, Ovid-Embase, National Guideline Clearinghouse, Guideline International Network) and domestic databases (KoreaMed, KMbase, and KoMGI) were searched for guidelines. The retrieved articles were analyzed by 2 reviewers, and articles were selected using well-established inclusion criteria. Results: The search identified 294 articles, of which 3 were selected as relevant guidelines. Based on those 3 guidelines, 3 recommendations for implant planning were derived. Conclusion: We recommend radiography or cone-beam computed tomography (CBCT) scanning for individual patients judged to require a cross-sectional image after reading of a panoramic X-ray image and a conventional intraoral radiological image. Various steps should be taken to raise awareness of these recommendations among clinicians and the public, and K-CIG should be regularly reviewed and revised.

Dental implant failures and complications - Retrospective study (치과 임플란트 실패와 합병증의 후향적 연구)

  • Park, Ju-Hee;Jo, Chan Woo;Woo, Jae-Man;Kahm, Se Hoon
    • The Journal of the Korean dental association
    • /
    • v.57 no.7
    • /
    • pp.372-378
    • /
    • 2019
  • The dental implants in modern dentistry brought out a new era in everyday dental practice. Increasing of dental implants usage, various failures and complications has occurred. Failures and complications of dental implant treatments that can happen in implant surgery, in mechanical or prosthetic problem and in biological aspect. The aim of this study was to assess implant failures for 6 years as well as find out how to overcome implant failure. In Jeju National University hospital, 26 dental implants in 17 patients were removed by implant failure through 2013.1.1.-2018.12.31. Each implant failure case was analyzed in report form with various informations about failure retrospectively. The present study showed 26 failed dental implants of 17 patients were removed. 13 implants(50%) of 8 patients(47.06%) were failed before functional loading and 13 implants(50%) of 9 patients(52.94%) were failed after functional loading. 11 implants(42.31%) of 7 patients(41.18%) with medical disease were extracted. 6 implants(23.08%) of 5 patients(29.41%) with additive bone graft were failed. We discuss with 26 failed dental implants of 17 patients about their causes, solutions and prevention retrospectively for 6 past years. Precise diagnosis and treatment planning are needed. Medically compromised patients and patients with implants and additive bone grafts should be cautiously treated with high failing possibilities.

  • PDF

The use of implant surveyed fixed prosthesis for removable partial denture with a few unilateral remaining teeth: A case report (편측 소수 잔존치 증례에서 CAD software를 활용한 planning 및 임플란트 서베이드 고정성 보철물을 이용한 국소의치 수복: 증례보고)

  • Park, Jeongkeun;Kim, Jong-Eun;Park, Ji-Man;Kim, Jeehwan;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.254-262
    • /
    • 2019
  • As implant can be covered by National Health Insurance Service (NHIS), it was increased the interest in the removable partial denture (RPD) with the surveyed fixed prosthesis supported by implant fixture. To achieve predictable result, it needs the prudent implant planning by basic principles of RPD and patient's residual ridge. This 67 years old age male had a few unilateral remaining teeth, and hoped the treatment covered by NHIS. As using CAD software, the position of implant is planned with regarding to occlusal table of provisional denture, basic principles of RPD, and resorbed residual ridge. The definitive prostheses can ensure the stability and retention of removable prosthesis. When planning implant fixed prostheses, the digital technique was utilized to consider basic principle of RPD and resorbed residual ridge. As a result, it provided satisfactory prostheses.