• Title/Summary/Keyword: implant occlusion

Search Result 402, Processing Time 0.022 seconds

Combination restorative restorations using conventional partial denture and CAD / CAM (Conventional partial denture와 CAD/CAM을 이용한 combination 보철물 수복)

  • Choi, Seok-yeun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.52-63
    • /
    • 2017
  • When you need to make an upper and lower full-mouth prosthesis, you should design a prosthesis by making an accurate diagnosis and planning well. In particular, in patients with occlusal plane collapsed and misplaced occlusal plane, the patient should be restored to the previous occlusal height and the correct occlusal plane should be created. In addition, appropriate materials should be used to ensure that the patient is able to chew the food well and not force it. When the implants are placed in an inappropriate position, the design of the prosthesis is determined by considering the relationship with the prosthesis and occlusion. Design should be made for the cleanliness around the implant.

The Applications of the Duplex Stainless Steel as Hyperthermia Materials

  • Kim, Young-Kon
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.7.1-7.1
    • /
    • 2009
  • The use of Duplex stainless steel as a thermo-implant categorizes into two clinical applications: hyperthermia and thermal ablation or destruction. The goal of hyperthermia is to destroy the heat-sensitive abnormal cells and minimize normal cell death maintaining heat between $42^{\circ}C$ and $46^{\circ}C$. Thermal ablation takes place when the local tissue temperature increases greater than $46^{\circ}C$. This elevated temperature denatures protein irreversibly resulting cellular death. The author introduced several thermo-implants such as thermo-rod, thermo-stent, thermo-coil and thermoacupuncture-needle. Those thermo-implants are made of duplex stainless steel which can produce regulated heat by itself within an induction magnetic field. Thermal ablation characteristics of the thermo-rod on tumor hyperthermia depend on configurations of the thermo-rods and the magnitude of the induction magnetic strength. The exothermic properties of the thermo-implants can be characterized using the calorimetric test and the heat affected zone(HAZ) analyses in vitro. Thermal radiation studies using thermo-coils and thermo-stents show the capability of the occlusion of animal blood vessels and inhibiting the proliferation of the abnormal smooth muscle cell growth and inflammatory cell reactions maintaining the heat between $42^{\circ}C$ and $46^{\circ}C$ minimizing a normal cell death in the study on external iliac artery of the New Zealand White (NZW) rabbit. Thermal stimulation study using thermo-acupuncture needles suggests the potential applications of the automated acupunctural therapies.

  • PDF

Delayed-type retrobulbar hematoma caused by low temperature after reconstruction of inferior blow-out fracture

  • Lee, Da Woon;Kim, Tae Hyung;Choi, Hwan Jun;Wee, Syeo Young
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.2
    • /
    • pp.110-114
    • /
    • 2021
  • Retrobulbar hemorrhage is a disastrous condition that can lead to permanent blindness. As such, rapid diagnosis and treatment are critical. Here, we report a patient who presented with retrobulbar hemorrhage following an orbital floor fracture. Restoration of inferior orbital wall with porous polyethylene implant was underwent. Four days after the orbital floor reconstruction, the patient smoked a cigarette outdoors in -3℃ weather. Cold temperature and smoking caused an increase in his systemic blood pressure. The elevated blood pressure increased intraorbital pressure to the extent of causing central retinal artery occlusion and exacerbated oozing. During exploratory surgery, 3 mL of hematoma and diffuse oozing without arterial bleeding were observed. Prompt diagnosis and treatment prevented vision impairment. Few studies have reported on the risk factors for retrobulbar hemorrhage. This case showed that daily activities, such as exposure to cold weather or tobacco smoking, could be risk factors for retrobulbar hemorrhage.

A Case of Middle Ear Implantation Using the Vibrant Soundbridge in a Patient with Bilateral Mixed Hearing Loss (양측 혼합성 난청 환자에서 Vibrant Soundbridge를 이용하여 시행한 인공중이이식술 1예)

  • Shin, Yong Gook;Gu, Ja Won;Kang, Jin Wook;Song, Mee Hyun
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.12
    • /
    • pp.705-709
    • /
    • 2018
  • It is challenging to achieve sufficient hearing gain in patients with mixed hearing loss. In chronic middle ear diseases, conventional passive reconstructive surgeries often result in suboptimal hearing gain and additional hearing aids may have limitations due to insufficient sound amplification, occlusion effect, acoustic feedback, and skin irritation. Middle ear implantation (MEI) using Vibrant Soundbridge (VSB) is another option for auditory rehabilitation in mixed hearing loss as well as sensorineural hearing loss. The floating mass transducer of VSB can be placed on various middle ear structures either directly or using different types of couplers in order to deliver vibratory mechanical energy to the cochlea. We report a patient who presented with bilateral mixed hearing loss due to chronic otitis media and had limitations using conventional hearing aids in the worse hearing ear. The patient was successfully treated with MEI using the Bell coupler together with middle ear surgery in a single step.

Conservative orthodontic treatment for severe pathologic migration following total glossectomy: A case report

  • Giap, Hai-Van;Jeon, Ji Yoon;Kim, Kee Deog;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.52 no.4
    • /
    • pp.298-307
    • /
    • 2022
  • Glossectomy combined with radiotherapy causes different levels of tongue function disorders and leads to severe malocclusion, with poor periodontal status in cancer survivors. Although affected patients require regular access to orthodontic care, special considerations are crucial for treatment planning. This case report describes the satisfactory orthodontic management for the correction of severe dental crowding in a 43-year-old female 6 years after treatment for tongue cancer with total glossectomy combined with radiotherapy, to envision the possibility of orthodontic care for oral cancer survivors. Extraction was performed to correct dental crowding and establish proper occlusion following alignment, after considering the possibility of osteoradionecrosis. Orthodontic mini-implants were used to provide skeletal anchorage required for closure of the extraction space and intrusion of the anterior teeth. The dental crowding was corrected, and Class I occlusal relationship was established after 36 months of treatment. The treatment outcome was sustained after 15 months of retention, and long-term follow-up was recommended.

Bone changes around the maxillary posterior teeth opposing the implants in mandible: a clinical study (하악 임플란트에 대합되는 상악 구치의 주변골 변화에 대한 임상연구)

  • Park, Chan-Jin;Huh, Yoon-Hyuk;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.301-309
    • /
    • 2015
  • Purpose: When the edentulous area is restored by implant prostheses, the opposing hypofunctioned teeth will receive physiologic mechanical stimuli. This study evaluated the bone changes around the maxillary teeth opposing an implant restoration installed in the mandibular posterior area. Materials and Methods: Radiographs of the opposing teeth were taken at prostheses delivery (baseline), 3 and 6 months later. A customized film holding device was fabricated to standardize the projection geometry for the serial radiographs of the opposing teeth. The gray values of the region of interest of each digital image were compared according to time. Repeated measured analysis of variance was performed at the 95% significance level. Results: The gray values of the alveolar bone around the antagonist teeth of implants increased with time. The changes in gray values of the middle area were greater than those of the crestal area. However, the gray values of the mesial and distal areas were not different. The changes in gray values were different according to the unloaded time. Conclusion: A change in bone tissue will occur if a proper physiologic load is again applied to the bone tissues around a hypofunctioned tooth.

The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment (변형된 임플란트 임시 지대주의 물성에 대한 연구)

  • Yang, Byung-Duk;Yoon, Tae-Ho;Choi, Un-Jae;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

Finite Element Stress Analysis of the Implant Fixture According to the Thread Configuration and the Loading Condition (임플란트 고정체의 나사산 형태와 하중조건에 따른 응력분석)

  • Ahn, Ouk-Ju;Jeong, Jai-Ok;Kim, Chang-Hyun;Kang, Dong Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.2
    • /
    • pp.153-167
    • /
    • 2005
  • The purpose of this study was to compare the v-shape thread with the square shape thread of fixture in the view of stress distribution pattern using finite element stress analysis. The finite element model was designed with the parallel placement of two standard fixtures(4.0 mm diameter ${\times}$ 11.5 mm length) on the region of mandibular 1st and 2nd molars. Three dimensional finite element model was created with the components of the implant and surrounding bone. This study simulated loads of 200 N at the central fossa in a axial direction (load A), 200 N at the buccal offset load that is 2 mm apart from central fossa in a axial direction (load B), 200 N at the buccal offset load that was 4 mm apart from central fossa in a axial direction (load C). These forces of load A',B',C' were applied to a $15^{\circ}$ inward oblique direction at that same site with 200 N. Von Mises stress values were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study : 1. The highest stress concentration occurred at the cervical region of the implant fixture. 2. Von Mises stress value of off-site region was higher than that of central fossa region. 3. Square shape thread type showed more even stress distribution in the vertical and oblique force than V-shape thread type. 4. Stress distribution was the most effective in the case of buccal offset load (2, 4 mm distance from central fossa) in the square shape thread type. 5. V-shape thread type revealed higher von Mises stress value than square shape thread type in all environmental condition. The results from numerical analyses concluded that square shape thread type had the lower destructive stress and more stress distribution between the fixture and bone interface than V-shape thread type. Therefore, square shape thread type was regarded as optimal thread configuration in biomechanical concepts.

3-Year Survival Analysis of RBM and Acid-Etched Surface Implants (RBM 표면 임플란트와 산부식 표면 임플란트의 3년 생존율에 대한 비교 연구)

  • Yoon, Dae-Woong;Kim, Moon-Seob;Jang, Han-Seung;Jin, Soo-Young;Mah, Deuk-Hyun;Jeong, Gyeong-Dal;Park, Hyun-Chun;Kim, Hee-Jung;Kim, Hak-Kyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.393-403
    • /
    • 2011
  • The purpose of this study was to analyze and compare survival rates of resorbable blast media(RBM) surface and acid-etched surface implants being usually used in clinics. RBM surface implants (USII, Osstem, Busan, Korea) or acid-etched surface implants ($Osseotite^{(R)}$, Biomet $3i^{[TM]}$, FL, USA) were placed in edentulous area of 140 patients between January of 2005 and March of 2007. The number of implants was 304, and 152 out of them were RBM surface implants while another 152 were acid-etched surface implants. According to the evaluation items, the survey was performed before and after the implants installations. The 3-year survival rates of both kind of implants were calculated. 1. Total of 152 RBM surface implants were placed. Among them, one implant was failed, which was implanted in the posterior mandible with D2 bone quality. The failure was resulted from fracture of the fixture. Others showed good results and survival rate of RBM surface implant was 99.34%. 2. Total of 152 acid-etched surface implants were placed. Seven implants of them were failed, thus, survival rate was 95.39%. The causes of the failures were considered as infection, overheat and the lack of initial stability. In this research, both implants showed good 3-year survival rate, although RMB surface implant represented a better result.

Fractal Analysis of Peri-Implant Bone Mineral Density before and after Functional Loading on Implant (기능하중에 따른 임플란트 주변 골밀도의 변화에 대한 프렉탈 구조 분석)

  • Hong, Seong-Wan;Lee, Jae-In;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.359-370
    • /
    • 2011
  • To identify osseointegration of implants, dentists were performed the radiographic analysis. The fractal analysis methods using periapical radiographs before and after loading on implants was to evaluate whether or not significant. 30 patients who were placed implants in dental hospital of Wonkwang university were participated in this study. Total of 42 implants were analyzed. And, 14 males and 16 females aged from 22 to 73 participated in this study. The two morphologic and Fractal analysis of the one trabecular patterns in alveolar bone were done using periapical views. Two periapical views, after implant placement, and after 2 months of functional loading were analysed. The analysis was done by software, Image J(1.40s, National Institute of Health, Bethesda, USA). The data were statistically analyzed using one-way ANOVA(P<.05). Multiple comparison was done by the Tukey HSD test. The results of Fractal analysis and change in bone density around implants showed significantly different values, especially mandibles. However, in case of implants with failure, Fractal values decreased from 1.2865 to 1.1521 and 1.1135 to 1.0478.