• Title/Summary/Keyword: implant length

Search Result 444, Processing Time 0.02 seconds

Modified Direct W-incision with Silicone Sheet to Minimize Operation Scar in Reconstruction of Mild to Moderate Symptomatic Medial Orbital Wall Fracture (경중도 안와 내벽 골절의 수술 시 흉터 최소화를 위한 변형된 직접 W-절개법과 실리콘판을 이용한 재건)

  • Jung, Jae A;Gong, Jung Sik;Kim, Yang Woo;Kang, So Ra
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Background: For reconstruction of the mild to moderate medial orbital wall fractures, various surgical approaches have been used. Prior existing W-shaped incision was a direct local approach through a 3 cm incision on the superior medial orbital area with a titanium mesh implant. In this study, the authors modified W-shaped incision and reconstructed the defect with silastic sheet to improve the result and the postoperative scar. Methods: This study included 20 patients who had mild to moderate size of medial wall defect and therefore relatively suitable for reconstruction with silastic sheets from July, 2009 to December, 2011. A modified W-shaped skin incision approximately 1.2 to 1.5 cm in length was made along the superior medial orbital rim from approximately 1 cm medial to the medial canthus to the lower border of the medial eyebrow. The angles of the limbs of the W ranged from 150 to 160 degrees. Results: By using soft flexible silastic sheet, the authors reduced the incision from 3 to 1.5 cm, and by widening the angle of the W limbs, scars were more effectively hided in the relaxed skin tension line. Scar assessment was done with modified patient and observer scar assessment scale and mean score from patients was 2.08 and mean score from observers was 2.12. Conclusion: Although this method will not be suitable for every case, it can be a consistent method to obtain the surgical goal in treatment of mild to moderate blowout fractures of the medial orbital wall.

Maxillary Sinus Floor Augmentation Using Autogenous Tooth Bone Graft in Combination with Platelet-Rich Plasma for Dental Implants: Case Series

  • Ha, Jinhee;Jeon, Dohyun;Sung, Iel-Yong;Cho, Yeong-Cheol;Lim, Se-Jeong;Son, Jang-Ho
    • Journal of Korean Dental Science
    • /
    • v.12 no.1
    • /
    • pp.5-12
    • /
    • 2019
  • Purpose: To determine the benefits of autogenous tooth bone (ATB) graft in combination with platelet-rich plasma (PRP) in the rates of success and survival of dental implants placed simultaneously with maxillary sinus floor augmentation (MSFA). Materials and Methods: Patients who visited the Department of Oral and Maxillofacial Surgery at Ulsan University Hospital from 2012 to 2014 and underwent simultaneous placement of implants with MSFA using ATB plus PRP were included in the study. Success and survival rates of the implants were evaluated based on the parameters of age and sex of the patient, site, follow-up period, residual bone height before surgery, diameter, and length of implant, sinus mucosa impairment, and postoperative complications. Result: A total of 23 patients and 67 implants were included in this study. The average age of the patients was $53.78{\pm}10.00$ years. The average follow-up period after installation of the prosthesis was $53{\pm}5$ months. The success and survival rates of the implants after placement of prosthesis were 95.52% and 97.01%, respectively. Conclusion: Combination of ATB and PRP showed high overall success rate, and it can be concluded that this combination is a predictable bone graft procedure for MSFA.

Correlation analysis of periodontal tissue dimensions in the esthetic zone using a non-invasive digital method

  • Kim, Yun-Jeong;Park, Ji-Man;Cho, Hyun-Jae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.2
    • /
    • pp.88-99
    • /
    • 2021
  • Purpose: Direct intraoral scanning and superimposing methods have recently been applied to measure the dimensions of periodontal tissues. The aim of this study was to analyze various correlations between labial gingival thickness and underlying alveolar bone thickness, as well as clinical parameters among 3 tooth types (central incisors, lateral incisors, and canines) using a digital method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomography images and intraoral scanned files were obtained. Measurements of labial alveolar bone and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. Clinical parameters including the crown width/crown length ratio, keratinized gingival width, gingival scallop, and transparency of the periodontal probe through the gingival sulcus were examined. Results: Gingival thickness at the alveolar crest level was positively correlated with the thickness of the alveolar bone plate (P<0.05). The central incisors revealed a strong correlation between labial alveolar bone thickness at 1 and 2 mm, respectively, inferior to the alveolar crest and the thickness of the gingiva at the alveolar crest line (G0), whereas G0 and labial bone thickness at every level were positively correlated in the lateral incisors and canines. No significant correlations were found between clinical parameters and hard or soft tissue thickness. Conclusions: Gingival thickness at the alveolar crest level revealed a positive correlation with labial alveolar bone thickness, although this correlation at identical depth levels was not significant. Gingival thickness, at or under the alveolar crest level, was not associated with the clinical parameters of the gingival features, such as the crown form, gingival scallop, or keratinized gingival width.

Effectiveness of the Invisalign Mandibular Advancement Appliance in Children with Class II Division 1 Malocclusion

  • So-Youn An;Hyeon-Jin Kim;Ho-Uk Lee;Sang-Ho Bak;Hyo-Jin Kang;Youn-Soo Shim
    • Journal of dental hygiene science
    • /
    • v.23 no.4
    • /
    • pp.245-254
    • /
    • 2023
  • Background: This study aimed to determine the skeletal and dental effects in pediatric and adolescent Korean patients with Class II Division 1 malocclusion treated using the Invisalign Mandibular Advancement (MA®) appliance. Methods: The study included patients aged 6 to 18 years who received orthodontic treatment with the MA® appliance for Class II Division 1 malocclusion at the Department of Pediatric Dentistry, Wonkwnag University Daejeon Dental Hospital, between July 1, 2018, and December 31, 2021. The treatment group consisted of 20 patients, 10 boys and 10 girls. The control participants were also 10 boys and 10 girls. Lateral cephalometric radiographs were taken before and after treatment, and 41 measurements of skeletal and dental changes were measured and analyzed using the V-CephTM 8.0 (Osstem Implant). All analyses were performed using SPSS software (IBM SPSS for Windows, ver 26.0; IBM Corp.), and statistical significance was tested using paired and independent samples t-tests for within-group and between-group comparisons, respectively. Results: The patients in the treatment group showed significant decreases in ANB (A point, Nasion, B point), maxillary protrusion, maxillary anterior incisor labial inclination, and maxillary protrusion after treatment. However, when compared with the growth changes observed in the control group, only ANB and maxillary protrusion decreased, with no significant differences in SNA, SNB, and mandibular length. Conclusion: Collectively, the results of this study confirm that the use of MA® appliance in pediatric and adolescent Korean patients with Class II Division 1 malocclusion results in a reduction of anteroposterior skeletal and dental disharmony.

Phytotherapy in periodontics as an effective and sustainable supplemental treatment: a narrative review

  • Abeer Saad Gawish;Mohammed Sherif ElMofty;Safa Jambi;Doaa Felemban;Yassmeen SalahEldin Ragheb;Shadia Abdelhameed Elsayed
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.4
    • /
    • pp.209-223
    • /
    • 2024
  • Purpose: Periodontal disease is a chronic condition caused by microbial infection and mediated by the host's immune response. Phytotherapy is a therapeutic approach that utilizes a renewable resource capable of supplying less expensive medicines for the world's growing population. This review aimed to present clinical evidence on the use of complementary medicinal herbs in the treatment of periodontal diseases. Methods: Different databases were searched using the terms "herbal" and "periodontitis." All included studies were examined with a focus on herbal indications, type, and prescription length. Dentists' therapeutic and prophylactic herbal prescribing habits were also assessed. Results: Various herbs such as turmeric, neem, aloe-vera, pomegranate, catechu, tulsi, cloves, lemon grass, green tea, tea tree oil, peppermint, garlic, pineapple, oak bark, babul, bakul, sage, coriander, moringa, amla, guava, and grape seed extract have been used in the treatment of periodontitis. These herbs have been reported to exhibit a range of therapeutic effects, including anti-inflammatory, antiplaque, antihalitosis, antiresorptive, antioxidant, antibacterial, antifungal, antiviral, and antimicrobial properties. These components can be utilized in various forms such as mouth rinse, gel, oil, toothpaste, aqueous extract, mouthwash, or tooth powder. Conclusions: Several readily available herbal formulations are now available on the market and have been shown to be effective as supplemental periodontal phytotherapy. However, these should be used under the supervision of a dental professional to ensure optimal benefits and effectiveness. Therefore, it is necessary to improve the understanding of suggested herbal prescription practices among dental professionals.

The influence of intentional mobilization of implant fixtures before osseointegration (골유착전 임플란트 고정체의 의원성 동요가 골결합에 미치는 영향)

  • Cho, Jin-Hyun;Jo, Kwang-Heon;Cho, Sung-Am;Lee, Kyu-Bok;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the influence of mobilization on bone-implant interface prior to osseointegration of fixtures. Materials and methods: The experimental implants (3.75 mm in diameter, 4.0 mm in length) were made of commercially pure (Grade IV) titanium, and were treated with RBM ($MegaGen^{(R)}$: Ca-P). The 80 implants (two in each tibia) were inserted into the monocortical tibias of 20 rabbits which each weighed more than 3.5 kg (Female, New Zealand White). According to the removal torque interval, the groups were divided into 10 groups, Group I (6 wks), Group II (4 days+6 wks), Group III (4 days+1 wk+6 wks), Group IV (1 wk+6 wks), Group V (1 wk+1 wk+6 wks), Group VI (2 wks+6 wks), Group VII (2 wks+ 1 wk+6 wk), Group VIII (3 wks+6 wks), Group IX (3 wks+1 wk+6 wks) and Group X (10 wks). The control groups were Group I and X, the removal torque was measured at 6 wks and 10 wks with a digital torque gauge (Mark-10, USA). In the experimental groups, the removal torque was given once or twice before the final removal torque and the value was measured each time. After which, the implants were put back where they had been except the control groups. All the experimental groups were given a final healing time (6 wks) before the final removal torque test, in which values were compared with the control groups and the 1st and/or 2nd removal torque values in each experimental group. Results: In the final removal torque tests, the removal torque value of Group X (10 wks) was higher than that of Group I (6 wks) in the control groups but not statistically different. There were no significant differences between the experimental groups and control groups (P>.05). In the first removal torque comparison, the experimental groups (4 days or 1 wk) values were significantly lower than the other experimental groups (2 wks or 3 wks). In the comparison of each experimental group according to healing time, the final removal torque value was significantly higher than the 1st torque test value. Conclusion: Once or twice mobilization of fixture prior to osseointegration did not deter the final bone to implant osseointegration, if sufficient healing time was given.

A Study on the Stress Distribution of Tooth/Implant Connected with Konus Telescope Denture Using 3-Dimensional Finite Element Method (이중관으로 연결된 자연치와 임플랜트의 악골 내응력분포에 관한 3차원 유한요소분석)

  • Lee, Su-Ok;Choi, Dae-Gyun;Kwon, Kung-Rock;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.381-395
    • /
    • 2008
  • Purpoose: For decades dental implants have been used widely in the field of prosthetic dentistry. However there is confusion when establishing treatment plans in cases where some teeth are remained but an insufficient number of implants can be used due to limited anatomical status and ecomomical problems. Many clinicians have tried to connect natural teeth and implants, and it still has controversy. But, there have been few studies on mechanical analysis of connecting natural teeth and implants with konus telescopic removable partial dentures. The purpose of this study was to analyze the stress distribution of prosthesis, abutment and alveolar bone when teeth and implants were connected with the konus telescopic denture, by means of 3-dimensional finite element analysis. Material and methods: The assumption of this study was that there were 2 mandibular canine (11 mm in length, 4 mm in diameter) and 2 implants(10 mm in length, 4 mm in diameter) which are located in the second premolar region. The mandible, teeth, implants, abutments, and connectors are modeled, and analyzed with the commercial software, ANSYS Version 8.1(Swanson, Inc., USA). The control group used implants instead of natural teeth. 21038 elements, 23544 nodes were used in experimental group and 107595 elements, 21963 nodes were used in control group, Stress distribution was evaluated under 150 N vertical load on 3 experimental conditions - between teeth and implants (Load case 1), posterior to implants (Load case 2), between natural teeth (Load case 3). Results: 1. In all load cases, higher von mises stress value was observed in the experimental group. 2. Maximum von miss stress observed in all load cases and all locations were as follows ; a. 929.44 Mpa in the experimental group, 640.044 Mpa in the control group in outer crown and connector - The experimental group showed 1.45 times high value compared with the control group. b. 145,051 Mpa in the experimental group, 142.338 Mpa in the control group in abutment - The experimental group showed 1.02times high value compared with the control group. c. 32.489 Mpa in the experimental group, 25.765 Mpa in the control group in alveolar bone - The experimental group showed 1.26times higher value compared with the control group. 3. All maximum von mises stress was observed in load case 2, and maxim von mises stress in alveolar bone was 32.489 Mpa at which implant failure cannot occur. 4. If maximum von mises stress is compared between two groups, the value of the experimental group is 1.02 times higher than the control group in abutment, 1.26 times higher than the control group in alveolar bone. Conclusion: If natural teeth and implants are connected with the konus telescopic denture, maximum stress will be similar in abutment, 1.26 times higher in alveolar bone than the control group. With this result, there may be possible to make to avoid konus telescopic dentures where natural teeth and implants exist together.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

Anatomical characteristics of the midpalatal suture area for miniscrew implantation using CT image (정중구개봉합부의 해부학적 구조에 관한 전산화 단층촬영을 이용한 연구)

  • Park, Young-Chel;Lee, Jong-Suk;Kim, Doo-Hyung
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.35-42
    • /
    • 2005
  • There is lack of data for the amount of vertical bone in the midpalatal region for miniscrew implantation. The purpose of this study was to measure the structure of the midpalatal suture area using CT image and V-works 4.0 program (Cybermed Inc, Seoul, Korea). CT images of 14 male and 14 female adults were reconstructed. In detail, it was 1) to measure the length of maxilla on the midsagittal plane 2) to measure vertical bone height in the midpalatal area 3) to establish the zone of safety for miniscrew implantation. The following results were obtained. The mean length of ANS-PNS was 51.08mm in males and 47.34mm in females. There was a statistically significant difference between males and females (p<0.05). The vertical bone height of the midpalatal suture area was above 0mm except for 6mm posterior from the central Point of ANS-PNS in males The zone of safety was located 19.43mm posterior from the ANS in males while it was 17.62mm in females along the palatal plane. These results support that the safety zone of the midpalatal area is suitable for screw implantation. Midpalatal miniscrew implantation is a powerful tool in modern orthodontics Through many applications. it can expand the modern orthodontic field.

MORPHOMETRICS OF ALVEOLAR PROCESS AND ANATOMICAL STRUCTURES AROUND INFERIOR MAXILLARY SINUS FOR MAXILLARY IMPLANTATION (임플랜트 시술을 위한 치조돌기와 상악동 주변 구조물의 형태계측적 연구)

  • Park, Ju-Jin;Lee, Young-Soo;Paik, Doo-Jin;Park, Won-Hee;Yoo, Dong-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.228-239
    • /
    • 2007
  • Statement of problem: Following tooth loss, the edentulous alveolar process of maxilla is affected by irreversible reabsorption process, with progressive sinus pneumatization leads to leaving inadquate bone height for placement of endosseous implants. Grafting the floor of maxillary sinus by sinus lifting surgery and augmentation of autologous bone or alternative bone material is a method of attaining sufficient bone height for maxillary implants placement and has proven to be a highty successful. Purpose: This study was undertaken to clarify the morphometric characteristics of inferior maxillary sinus and alveolar process for installation of implants. Material and method: Nineteen skulls (37 sinuses, 10M / 9F) obtained from the collection of the department of anatomy and cell biology of Hanyang medical school were studied. The mean age of the deceased was 69.9 years (range 44 to 88 years). The distance between alveolar border and inferior sinus margin at each tooth, the height of alveolar process and the thickness of cortical bone of the outer and inner table of alveolar process and the inferior wall of maxillary sinus were measured. Results and Conclusion: 1. The septum of inferior maxillary sinus were observe 28 sides (76.%) and located at the third molar (52.6%) and the second molar (26.3%). The deepest points of inferior border of maxillary sinus were located the first or second molar. The distance between alveolar margin and the deepest point of inferior maxillary sinus is $9.7{\pm}4.9mm$. 2. The length of the outer table of alveolar process were $4.9\sim28.2mm$ and the shortest point was between the first and the second molors. The thickness of them were $0.9\sim3.2mm$. The length of the inner table of alveolar process were $7.4\sim25.8mm$ and the shortest point was between the first and the second molars. The thickness of the were $0.9\sim4.6mm$. The results of this study are useful anatomical data for installing of maxillary implants.