• 제목/요약/키워드: implant impression

검색결과 110건 처리시간 0.023초

전기방전가공법을 이용한 임플랜트 보철물의 적합도 연구 (A STUDY ON THE FIT OF IMPLANT-RETAINED PROSTHESES USING ELECTRIC DISCHARGE MACHINING)

  • 한의택;김영수;김창회;양재호
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.1-13
    • /
    • 2001
  • An absolutely passive fit at the interface with the superstructure and the abutment cylinders is need for implant longevity. In this study, a method of cast framework correction using spark erosion technology was evaluated. Electric discharge machining(EDM) is a process that uses electrical discharges, or sparks, to machine metal, The surface being machined is bombared with high-intensity electrical energy pulses that gradually melt away the stock until the desired configuration is obtained. Master model was fabricated by using metal block impression analogue, which fired 5 Branemark squared impression coping in an arc shaped metal block. Then framework using 4mm standard gold cylinder and type IV gold alloy was fabricated. In order to measure the fit of the framework we used both contact and noncontact coordinate measurement machine and data was processed by computer program. After superimposition of gold framework and master model numeric image data the distances between gold cylinder bearing surfaces and abutment replica bearing surfaces, and the angle deviations between gold cylinder and abutment replica centroid points were calculated. The results were as follows 1 The total mean distance (p<0.01) and standard deviation (p<0.001) between the gold cylinders and abutment bearing surfaces were significantly decreased after EDM 2. The total mean of maximum distances was significantly decreased after EDM (p<0.05). 3. After EDM, the mean angle deviation between centroid points was decreased.

  • PDF

임플랜트 지지 상부구조물에서 나사조임순서와 조임방법이 풀림토크값에 미치는 영향 (THE EFFECT OF SCREW TIGHTENING SEQUENCE AND TIGHTENING METHOD ON THE DETORQUE VALUE IN IMPLANT-SUPPORTED SUPERSTRUCTURE)

  • 최정한;김창회;임영준;김명주;이석형
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.653-664
    • /
    • 2007
  • Statement of problem: The screw detorque value is a measure of the preload remaining in the screw just before detorquing. Purpose: This study evaluated the effect of different screw tightening sequences and tightening methods on detorque values for a well-fitting implant superstructure. Material and method: An implant superstructure that connected directly to four implants (Astra Tech) was fabricated on a fully edentulous mandibular acrylic resin model. Six well-fitting dental stone casts were made with a pickup impression of the superstructure from the acrylic resin model. To evaluate the effect of three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and two tightening methods (2-step and 1-step) on the stability of screw joint, the detorque values for a well-fitting implant superstructure were measured twice after screw tightening using 20 Ncm. Detorque values were analyzed using multi-way analysis of variance and two-way analysis of variance at a .05 level of significance. Results: 1. The mean detorque values for three screw tightening sequences were 12.3 Ncm, 12.6 Ncm, and 12.0 Ncm, respectively. 2. The mean detorque values for two screw tightening methods were 12.0 Ncm, and 12.2 Ncm, respectively. 3. The mean of mimimum detorque values for three screw tightening sequences and for two tightening methods were 10.6 Ncm, 11.1 Ncm, 10.5 Ncm, and 9.8 Ncm, respectively. 4. No statistically significant differences among the variables of screw tightening sequence and tightening method were found (p>.05) for detorque values and for mimimum detorque values. Conclusion: Within the limitations of this study, the screw tightening sequence and tightening method did not have a significant effect on the detorque values for a well-fitting implant superstructure.

Peri-implant bone length changes and survival rates of implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height

  • Kim, Hae-Young;Yang, Jin-Yong;Chung, Bo-Yoon;Kim, Jeong Chan;Yeo, In-Sung
    • Journal of Periodontal and Implant Science
    • /
    • 제43권2호
    • /
    • pp.58-63
    • /
    • 2013
  • Purpose: The aim of this study was to measure the peri-implant bone length surrounding implants that penetrate the sinus membrane at the posterior maxilla and to evaluate the survival rate of these implants. Methods: Treatment records and orthopantomographs of 39 patients were reviewed and analyzed. The patients had partial edentulism at the posterior maxilla and limited vertical bone height below the maxillary sinus. Implants were inserted into the posterior maxilla, penetrating the sinus membrane. Four months after implant insertion, provisional resin restorations were temporarily cemented to the abutments and used for one month. Then, a final impression was taken at the abutment level, and final cement-retained restorations were delivered with mutually protected occlusion. The complications from the implant surgery were examined, the number of failed implants was counted, and the survival rate was calculated. The periimplant bone lengths were measured using radiographs. The changes in initial and final peri-implant bone lengths were statistically analyzed. Results: Nasal bleeding occurred after implant surgery in three patients. No other complications were found. There were no failures of the investigated implants, resulting in a survival rate of 100%. Significantly more bone gain around the implants (estimated difference=-0.6 mm, P=0.025) occurred when the initial residual bone height was less than 5 mm compared to the >5 mm groups. No significant change in peri-implant bone length was detected when the initial residual bone height was 5 mm or larger. Conclusions: This study suggests that implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height may be safe and functional.

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF

A 10-year follow-up study on clinical outcomes of dental implant rehabilitation using surgical guide

  • Haoyun Li;Mi Young Eo;Kezia Rachellea Mustakim;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제50권2호
    • /
    • pp.70-79
    • /
    • 2024
  • Objectives: The surgical guide is a static computer-assisted device used for implant surgery planning and guidance. By taking an impression and referring to the patients' three-dimensional computed tomography scan of the desired implant site, a surgical guide can be created. During surgery, the surgical guide aids in achieving the designed implant placement position and direction. We examined and evaluated the long-term clinical outcomes of implant surgery using surgical guides. Materials and Methods: This study investigated a total of 15 patients with 32 implants that were placed using surgical guides from 2009 to 2011 with a mean follow-up period extended beyond 10 years. Patient demographics and implant survival rates were recorded. We analyzed marginal bone loss (MBL) by assessing the radiographs acquired at installation, three months after installation, and one month, one, two, and five years after prosthesis delivery. Results: The mean patient age was 57.33 years at implant placement. Of the 32 implants, five implants were placed in the anterior region and 27 implants were in the posterior region. Six implants failed and three of them were replaced, resulting in an 81.25% survival rate. The mean follow-up period was 10 years and nine months. Mean MBL compared to post-installation was significantly higher than at three months after installation, and one month, one, two, and five years after prosthesis delivery. Mean MBL at three months after installation, and one month, one year, and two years were significantly higher compared to the previous visit (P<0.05). However, MBL at five years after prosthesis delivery did not differ significantly compared to at two years. Conclusion: In this study, implant rehabilitation assisted by surgical guides exhibited favorable survival rates. With the limitation of the sample amount in this study, further research and more samples are required to evaluate the long-term clinical effectiveness of surgical guides.

즉시 Frialit-2 implant 식립, 즉시 임시치관 제작 그리고 IPS Empress 2 crown을 이용한 상악중절치의 심미적 수복 (Esthetic reconstruction of upper central incisor using immediate Frialit-2 implant placement, immediate temporary crown fabrication and IPS Empress 2 crown)

  • 김유리;오상천
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.43-48
    • /
    • 2003
  • During the past several years, significant advances have occurred in the utilization of osseointegrated implants for the treatment of partially edentulous patients. One of the biggest purposes for treating of these patients is the high demand for improved esthetics, especially in the anterior region. For this esthetics, the new trend in dental implants is the immediate placement and immediate superstructure fabrication. The refined surgical technique, the skillful soft tissue management, and the proper prosthetic coordination are the main factors to achieve natural looking of implant supported prosthesis. The customized provisional restoration and the customized impression coping are recommended for the optimal peri-implant soft tissue contour. The basic concept of Frialit 2 system was the immediate replacement of a tooth with root-analog fixture after extraction. This system guarantees an ideal result in function and esthetics. The ceramic abutment system offers improved quality in the respect of esthetics, fitness, translucency, and biocompatibility. In this clinical report, the final restoration made with IPS Empress 2 crown on the CeraBase abutmen of Frialit 2 system allowed the reproduction of the natural vitality of tooth and adjacent gingiva.

Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사 (Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement)

  • 김원;김승미;김효정;송은영;이시호;오남식
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.175-184
    • /
    • 2011
  • Computer-guided system은 술 전에 임플란트 위치를 계획하고 이와 일치하도록 구강 내에 임플란트를 식립할 수 있게 하는 방법이다. 하지만 이렇게 임플란트를 식립한다 할지라도 실제 매식된 임플란트의 위치는 원래 계획하였던 위치와 차이가 있을 수 있다. 이 연구의 목적은 실제 임상에서 computer guided system을 이용하여 임플란트를 식립한 환자들의 경우 계획한 위치와 실제 식립된 임플란트 사이에 발생하는 변위량의 범위를 알아보고 그 임상적 적합성을 평가하는 것이다. 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden)을 이용하여 Br${\aa}$nemark MK III Groovy RP (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden)임플란트 식립을 시행 받은 다섯 명의 환자를 선정하였다. 수술용 형판에 지대주 유사체를 연결한 후 술 전 측정 모형을 제작하였고 최종 보철물 제작 시 최종 인상을 채득하여 술 후 측정 모형을 제작하였다. 두 측정 모형의 CT 방사선 사진을 촬영 후 3차원적으로 재현하였고 재현된 모델 상에서 식립된 임플란트 위치를 지정하였다. 각 임플란트는 임플란트 경부와 첨단의 중심점을 연결하여 임플란트 축을 설정하였으며 두 축 간의 각도가 측정되었다. 임플란트 간 거리는 각 임플란트의 경부에서, 설정된 임플란트 축이 지나가는 중심점 간의 거리를 측정하였다. 총 5명 환자의 58개 부위의 임플란트 간 술 전과 술 후 임플란트 거리와 각도 변위량이 기록되었으며 평균 및 최대 변위값을 산출하였다. 술 전과 술 후 임플란트 위치 간 거리의 변위량은 평균 0.41 mm였고 최대 1.7 mm의 범위 하에 있었다. 술 전과 술 후 임플란트 간 위치의 각도의 변위량은 평균 $1.99^{\circ}$를 나타냈으며 최대 각도 변위량은 $6.7^{\circ}$를 나타내었다. 술 전 계획된 임플란트와 술 후 식립된 임플란트 간의 길이와 각도에 따른 평균 변위량은 computer-guided implant system을 실제 임상에 적용하는 데 있어 큰 문제가 존재하지 않고 '수동적 적합(passive fit)'을 얻기에 무리가 없을 허용 가능할 만한 값을 나타냈다.

Retrospective clinical study of ultrawide implants more than 6 mm in diameter

  • Ku, Jeong-Kui;Yi, Yang-Jin;Yun, Pil-Young;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.30.1-30.6
    • /
    • 2016
  • Background: The prognosis of wide implants tends to be controversial. While wider implants were initially expected to result in a larger osseointegration area and have higher levels of primary stability, they were reported to have a relatively high rate of failure. The clinical outcome of ultrawide implants of more than 6 mm in diameter was evaluated through a retrospective study. Methods: The investigation was conducted on patients who had received ultrawide implant (${\geq}6mm$ diameter) placements in Seoul National University Bundang Hospital from January 2008 to December 2013. Complications were investigated during the maintenance period, and marginal bone loss was measured using periapical radiography. Primary stability immediately after the implant placement and second stability after second surgery or during impression were measured using $Osstell^{(R)}$ Mentor (Osstell, Sweden) as an implant stability quotient (ISQ). Results: Fifty-eight implants were placed in 53 patients (30 male, 23 female), and they were observed for an average of $50.06{\pm}23.49$ months. The average ISQ value increased from $71.22{\pm}10.26$ to $77.48{\pm}8.98$ (P < 0.005). The primary and secondary stability shows significantly higher at the mandible than at the maxilla (P < 0.001). However, mean survival rate shows 98.28 %. Average marginal bone loss of 0.018 and 0.045 mm were measured at 12 and 24 months after the loading and 0.14 mm at final follow-up date (mean 46.25 months), respectively. Also in this study, the bone loss amount was noticeably small compared to regular implants reported in previous studies. Conclusions: The excellent clinical outcome of ultrawide implants was confirmed. It was determined that an ultrawide implant can be used as an alternative when the bone quality in the posterior teeth is relatively low or when a previous implant has failed.

무치악 환자에서 디지털 가이드를 이용한 임플란트 수복증례 (Implant-assisted full denture using digital guide: a case report)

  • 김욱태
    • 대한치과기공학회지
    • /
    • 제43권4호
    • /
    • pp.202-209
    • /
    • 2021
  • By classifying temporary denture production for surgical guides, digital guide-based surgery, and final prosthesis production, the problems of each process were assessed in advance and the factors that could be improved were confirmed in this study. The manufacturing process of fusion dental prosthesis uses virtual programs and computed tomography images to manufacture devices using the latest technologies of computer-aided design/computer-aided manufacturing and three-dimensional printing, which enables implants to be placed in the desired location in advance. Moreover, implant placement is not dependent on the skill and condition of the dentist, and because it uses a computer system, it can always be performed at a constant and optimal position. This can reduce the remanufacturing rate compared with the general method, shorten the treatment period, and eliminate patient discomfort. Unlike the traditional method of using impression materials and plaster models, digital fusion dental prostheses would be evaluated as a technology for producing prosthesis through professional design technology and communication.

중증 근무력증 환자에서 폐구 인상법을 이용한 임플란트 피개의치 수복 증례 (Implant overdenture with closed impression technique for patient with Myasthenia Gravis: A case report)

  • 박루디아;박민혁;박상원;임현필;장우형
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.459-468
    • /
    • 2021
  • 중증 근무력증을 가지고 있는 환자의 경우 구강 내 근육 및 신경계가 적절히 조정되지 않아 의치 제작 및 유지가 어렵다. 또한 과도하게 확장되거나 두꺼운 의치는 근육에 자극을 주어 근무력 증상을 유발할 수 있으므로 이를 고려하여 의치 제작을 해야 한다. 본 증례에서는 개구 제한을 가진 중증 근무력증을 가진 환자에서 폐구 인상법을 이용하여 의치를 제작하였다. 폐구인상법을 이용하여 환자가 가지고 있는 저작압 및 근육의 움직임을 재현하고 이를 통해 구강 기능 운동시 구강 내 근육에 자극이 적고 적절한 유지와 안정을 갖는 임플란트 유지 피개의치를 제작하였다.