• Title/Summary/Keyword: implant impression

Search Result 110, Processing Time 0.044 seconds

Immediate restoration through gingiva conditioning of maxillary anterior implant installed labially: A case report (순측으로 식립된 상악 우측 측절치 임플란트의 즉시 수복 증례)

  • Sung ji Gong;Jieun Song;Kwidug Yun;Chan Park;Woohyung Jang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.3
    • /
    • pp.234-242
    • /
    • 2024
  • Immediate implant placement and restoration have the advantage of shortening the treatment period and maintaining aesthetics until final restoration. However, single implant restoration in the maxillary anterior region may be aesthetically difficult, and surgical trauma delivered to soft and hard tissues during implant placement may affect future aesthetic results. In order to obtain predictable results during anterior implant placement and restoration, surgery and restoration plans must consider the height of the interdental bone, characteristics of the gingiva, and morphological characteristics of the patient's teeth. In this case, we attempted to reproduce the emergence profile and stabilized soft tissue through gingiva modification and digital impression of a labially placed maxillary anterior implant in a patient who desired porcelain fused-metal (PFM) restoration due to economic issues.

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

Clinical accuracy of impression technique using digital superimposition of customized abutment with subgingival margin: A case report (치은연하 변연을 가지는 맞춤형 지대주에서 디지털 중첩기술을 이용한 인상채득술의 임상 적용 증례)

  • Kim, Jin-Wan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeonjong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.169-175
    • /
    • 2020
  • Traditionally, gingival retraction has been performed to obtain customized abutment impressions with subgingival margins of the implant supported prosthesis. However, gingival retraction may have side effects such as gingival recession and bleed, leading to an inaccurate impression. In order to prevent these problems, in this case, the new technique has been introduced; a customized abutment which is designed for superimposition is used. Before the connection of the abutment to the implant fixture, pre-scanned shape data are stored, and then the optical impression without gingival retraction is obtained after connecting to the fixture. The suprastructure is fabricated by superimposing the two data. This technique showed the clinical efficacy of fabricating the implant supported prosthesis with subgingival margin, which satisfied the aesthetics, convenience, and clinically acceptable marginal and internal fit.

Cytotoxicity(MTT) evaluation of dental instruments made of polymers (치과용 폴리머 기구의 세포독성(MTT) 평가)

  • Choi, Eun-Mi
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.187-195
    • /
    • 2021
  • In order to assess the cell toxicity of 10 instruments made of polymers, the MTT assay which utilizes the L-929 cell was selected. Specimens were eluted at a temperature of 37℃ for 24 hours at a rate of 4g per 20mL, RPMI 1640, and then was positively and negatively contrasted with a control test solution, in accordance with the Notification No. 2020-12 Protocols of Medical Apparatus Biological Safety from the Ministry of Drug and Food Safety. As a result of 24 hours of incubation in 37℃, 5% CO2 Incubator and assessment using an ELISA reader, the results of Intraoral camera indiciated a cellular viability of more than 70% at a 50% eluate. But, the Plastic impression tray, 3D printing tweezer, Impression disposable syringe, Dental floss holder, Hand implant scaler, Surgical retractor, Oral scanner tip, Dental mirror, and the Water pick tip all reported a cellular viability of more than 70% at a 100% eluate, which indicates that do not exhibit cytotoxicity, thus allowing it to be used in contact with the mucous membrane of the oral cavity.

Retrospective study of implant stability according to the implant length, diameter and position (임플란트 길이, 직경 및 식립 위치에 따른 임플란트 안정성에 관한 후향적 연구)

  • Kim, Ji-Hye;Jeon, Jin-Yong;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Purpose: The aim of this retrospective study was to evaluate the influence of implant diameter, length and placement to implant stability. Materials and methods: Total 90 implants (US II plus$^{TM}$, Osstem co, Busan, Korea) of 72 patients were determined as experimental samples. The factors of diameters(${\phi}$ 4 mm, ${\phi}$ 5 mm), lengths (10 mm, 11.5 mm, 13 mm), and implant placement (maxilla, mandible) were analyzed. The stability of the implants was measured by resonance frequency analysis (RFA) at the time of implant placement and impression taking. The difference of ISQ values according to patient's gender was evaluated by Independent t-test. ISQ values were compared between implant diameter, length and placement using one-way ANOVA and Tukey HSD test (${\alpha}=.05$). To compare ISQ values between at the time of surgery and impression taking, paired t-tests were used (${\alpha}=.05$). Results: The change of implant length did not show significant different on the ISQ value (P>.05). However, 5 mm diameter implants had higher ISQ values than 4 mm diameter implants (P<.05). Implants placed on the mandible showed significantly higher ISQ values than on the maxilla (P<.05). Conclusion: In order to increase implant stability, it is better to select the wider implant, and implants placed on mandible are possible to get higher stability than maxilla. ISQ values at impression taking showed higher implant stability than ISQ values at implant placement, it means that RFA is clinically effective method to evaluate the change of implant stability through the osseointegration. The consideration of the factors which may affect to the implant stability will help to determine the time of load applying and increase the implant success rate.

Comparison of patient satisfaction with digital and conventional impression for prosthodontic treatment (보철 치료 시 디지털 및 전통적 인상채득에 대한 환자 만족도 비교 연구)

  • Yoon, Hyung-In;Lee, Su-Min;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.379-386
    • /
    • 2016
  • Purpose: The present study aims at researching the subjective satisfaction of patients who have experienced both conventional impression taking and digital impression taking to measure the possibility of wide clinical application of digital impression. Materials and methods: The study surveyed 170 adult patients over the age of 20, between October 2015 and April 2016, who voluntarily consented to participation and who experienced both conventional impression and digital impression at five dental hospitals that use intraoral digital impression. A total of 128 surveys were used for data analysis, involving frequency analysis, multiple response frequency analysis, descriptive statistics, and contingency table analysis, with the significance level set at 0.05. Results: Responses on the reason for taking impressions using the digital method appeared in the order of 'for implant treatment' (43.8%), 'for crown treatment' (30.5%), and 'for inlay treatment' (15.6%). Patients satisfaction was higher for digital impression taking than conventional impression taking (P<.05). As the preferred choice of impression, digital impression (60.2%) was higher than conventional impression (11.7%). Responses on the reason for choosing digital impression taking appeared in the order of 'no vomiting reflex' (35.1%), 'reliability of 3D digital scanning' (33.8%), and 'short time' (33.8%). Conclusion: The patients preferred digital impression taking to conventional impression taking in terms of satisfaction.

A procedure for the computer-guided implant planning: A narrative review (임플란트 가이드 수술을 위한 Planning 방식에 대한 고찰)

  • Kim, Jong-Eun;Kim, Nam-Hoon;Park, Ji-Hyun;Shim, June-Sung
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.108-122
    • /
    • 2016
  • Prosthetic-driven implant placement is a concept considering the dental implant restoration first based on the final form of that prosthesis to be restored. The latest development of the imaging technology and digital dentistry was able to be obtained the high quality images of CBCT with low radiation exposure and it has also enabled the process to reconstruct the intraoral state in three dimensions due to the development of the intraoral, model and impression scanner. Computer-guided implant placement simulations and template production was able to be more widely used in this context. In this narrative review, the features and the types of implant surgical guides will be introduced. It will also be described the diagnosis and treatment plan using computerguided implant software to reduce the number of visit and to increase the accuracy of the implant surgery through the top-down approach based on the shape and location of the final prosthesis.

  • PDF

Single-tooth implant restoration with alveolar bone augmentation in the maxillary anterior tooth region: a case report

  • Lee, Seon-Ki
    • International Journal of Oral Biology
    • /
    • v.46 no.4
    • /
    • pp.200-207
    • /
    • 2021
  • In case of gingival recession and alveolar bone defects due to tooth loss for a long period of time in a single tooth in the maxillary anterior region, it is not easy to obtain aesthetic results with a single implant prosthesis. For aesthetic restoration, it is important to preserve hard and soft tissues through alveolar bone augmentation as well as restore harmony with adjacent teeth and soft tissues by placing the implant in an ideal location. In this case, an implant was placed using guided bone regeneration and a connective tissue graft simultaneously with immediate implantation after extraction from the maxillary anterior region where only residual root was left for a long period of time.

Reverse engineering technique on the evaluation of impression accuracy in angulated implants (경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법)

  • Jung, Hong-Taek;Lee, Ki-Sun;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.261-270
    • /
    • 2021
  • Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.