• 제목/요약/키워드: implant failure

검색결과 305건 처리시간 0.03초

보철전단계의 치과 임프란트 실패 (PREPROSTHETIC STAGE DENTAL IMPLANT FAILURE)

  • 김재승;장현호;장철호;류성호;강재현
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권2호
    • /
    • pp.178-183
    • /
    • 2001
  • Since the introduction of the concept of osseointegration, the success rate of dental implant has increased dramatically. So, the uses of dental implant in the treatment of partially or fully edentulous patients have played an important role in dental rehabilitation. Regardless of high success rate of dental implant, some amounts of fixtures cannot help failing. We can classify dental implant failure according to timing, causative factor, etc. This study is focused on dental implant fixture failure, occurring during preprosthetic stage. There are various reasons that cause implant failure on this periods, such as improper patient selection, poor bone quality, and periimplantitis, etc. We investigate the survival rate of 1058 fixtures, which installed in 306 patients in our clinic from January 1997 to December 1999, according to type, sex, location, fixture length and width, using Kaplan-Meier product-limit method and to compare each other with log-rank test. Overall survival rate was 96.80%, and 33 implants failed over the preprosthetic stage. Our survey data identified posterior location of mandible as being associated with implant failure(P<0.05).

  • PDF

Space holder 공정으로 제조된 치과 임플란트용 타이타늄 다공체의 파손 분석 (Fracture Analysis of Porous Titanium for Dental Implant Fabricated by Space Holder Process)

  • 이승미;장진만;이원식;변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권2호
    • /
    • pp.104-109
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze fracture behavior and failure mechanism of porous titanium for dental implant fabricated by space holder process. Method: Three porous titanium specimens with a specific volume fraction of open pore were test by 3 point bending and compression stress condition, respectively. Fracture appearance was observed by scanning electron microscope and discussed in relation with oxygen content. Results: For compression-tested specimens, two specimen showed brittle failure, while the other one showed normal failure after deformation. High oxygen content was detected in the brittle-fractured specimen. Several micro-cracks initiated at the struts propagated down to the bottom of the specimen resulting in normal failure. Conclusion: Oxygen contamination during the fabrication process can leads brittle premature failure, and hence quality problem of the porous titanium for dental implant.

$\cdot$하악 대구치 부위에 식립된 임플란트의 생존율에 대한 후향적 연구 (Survival analysis of dental implants in maxillary and mandibular molar regions; A 4$\sim$5 year report)

  • 장진화;류경호;정현주
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.165-180
    • /
    • 2007
  • Dental Implants have been proved to be successful prosthetic modality in edentulous patients for 10 years. However, there are few reports on the survival of implant according to location in molar regions. The purpose of this study was to evaluate the $4{\sim}5$ years' cumulative survival rate and the cause of failure of dental implants in different locations for maxillary and mandibular molars. Among the implants placed in molar regions in Gwangju Mir Dental Hospital from Jan. 2001 to Jun. 2002, 473 implants from 166 patients(age range; $26{\sim}75$) were followed and evaluated retrospectively for the causes of failure. We included 417 implants in 126 periodontally compromised patients, 56 implants in 40 periodontal healthy patients, and 205 maxillary and 268 mandibular molar implants. Implant survival rates by various subject factors, surgical factors, fixture factors, and prosthetic factors at each location were compared using Chi-square test and Kaplan-Meier cumulative survival analysis was done for follow-up(FU) periods. The overall failure rate at 5 years was 1O.2%(subject level) and 5.5%(implant level). The overall survival rates of implants during the FU periods were 94.5% with 91.3% in maxillary first molar, 91.1% in maxillary second molar, 99.2% in mandibular first molar and 94,8% in mandibular second molar regions. The survival rates differed significantly between both jaws and among different implant locations(p<0.05), whereas the survival rates of functionally loaded implants were similar in different locations. The survival rates were not different according to gender, age, previous periodontal status, surgery stage, bone graft type, or the prosthetic type. The overall survival rate was low in dental implant of too wide diameter(${\geq}5.75$ mm) and the survival rate was significantly lower for wider implant diameter(p

Repeated failure of implants at the same site: a retrospective clinical study

  • Kang, Dong-Woo;Kim, So-Hyun;Choi, Yong-Hoon;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.27.1-27.9
    • /
    • 2019
  • Background: Implants are becoming the first choice of rehabilitation for tooth loss. Even though they have a high success rate, failures still occur for many reasons. The objective of this study is to analyze the reasons for recurring failure at the same site and the results of re-implantation. Methods: Thirteen patients (11 males and 2 females, mean age 60 ± 9.9 years) who experienced implant surgery failure at the same site (same tooth extraction area) two or more times in the Department of Oral and Maxillofacial Surgery, Seoul National University Bundang Hospital, between 2004 and 2017 were selected. The medical records on a type, sites, diameter, and length of implants; time and estimated cause of failure; and radiographs were reviewed. Data were collected and analyzed retrospectively, and the current statuses were evaluated. Results: A total of 14 implants experienced failure in the same site more than two times. Twelve implants were placed in the maxilla, while 2 implants were placed in the mandible. The maxillary molar area was the most common site of failure (57.1%), followed by the mandibular molar, anterior maxilla, and premolar areas (14.3% each). The first failure occurred most commonly after prosthetic treatment (35.7%) with an average period of failure of 3.8 months after loading. Ten cases were treated as immediate re-implantation, while the other 4 were delayed reimplantation after an average of 3.9 months. The second failure occurred most commonly after prosthetic treatment (42.9%), with an average of 31 months after loading; during the healing period (42.9%); and during the ongoing prosthetic period (14.3%). In 3 cases (21.4%), the treatment plan was altered to an implant bridge, while the other 11 cases underwent another implant placement procedure (78.6%). Finally, a total of 9 implants (64.3%) survived, with an average functioning period of 60 months. Conclusions: Implants can fail repeatedly at the same site due to overloading, infection, and other unspecified reasons. The age and sex of the patient and the location of implant placement seem to be associated with recurring failure. Type of implant, bone augmentation, and bone materials used are less relevant.

Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching

  • Hyeon Jang Jeong;Ji Soo Lee;Young Kyu Kim;Sung-Min Rhee;Joo Han Oh
    • Clinics in Shoulder and Elbow
    • /
    • 제26권3호
    • /
    • pp.276-286
    • /
    • 2023
  • Background: The transosseous anchorless repair (ToR) technique was recently introduced to avoid suture anchor-related problems. While favorable outcomes of the ToR technique have been reported, no previous studies on peri-implant cyst formation with the ToR technique exist. Therefore, this study compared the clinical outcomes and prevalence of peri-implant cyst formation between the ToR technique and the conventional transosseous equivalent technique using suture anchors (SA). Methods: Cases with arthroscopic rotator cuff repair (ARCR) between 2016 and 2018 treated with the double-row suture bridge technique were retrospectively reviewed. Patients were divided into ToR and SA groups. To compare clinical outcomes, 19 ToR and 57 SA cases without intraoperative implant failure were selected using propensity score matching (PSM). While intraoperative implant failure rate was analyzed before PSM, retear rate, peri-implant cyst formation rate, and functional outcomes were compared after PSM. Results: The intraoperative implant failure rate (ToR, 8% vs. SA, 15.3%) and retear rate (ToR, 5.3% vs. SA, 19.3%) did not differ between the two groups (all P>0.05). However, peri-implant cysts were not observed in the ToR group, while they were observed in 16.7% of the SA group (P=0.008). Postoperative functional outcomes were not significantly different between the two groups (all P>0.05). Conclusions: The ToR technique produced comparable clinical outcomes to conventional techniques. Considering the prospect of potential additional surgeries, the absence of peri-implant cyst formation might be an advantage of ToR. Furthermore, ToR might reduce the medical costs related to suture anchors and, thereby, could be a useful option for ARCR. Level of evidence: III.

파절된 임프란트 고정체의 분석과 처치 (AN ANALYSIS AND MANAGEMENT OF FRACTURED IMPLANTS)

  • 한종현;김성현;허성주;구영
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.25-36
    • /
    • 2001
  • Among the numerous factors contributing to implant failure, the most common are infection, failure of proper healing and overload. These factors may occur combined. Implant fractures are one of the complications resulting from overload. Implant fracture is not a common feature, but once it occurs it causes very unpleasant circumstances for the patient as well as for the practitioner. Only few studies have been reported regarding this subject. Thus, little is known about its solutions. It is important that analyzing reasons for implant fracture and finding appropriate solutions. Factors leading to implant fracture are design, material defects, nonpassive fit of prosthetic framework and biomechanical overload. Previous studies have reported that implant fractures ares associated with marginal bone loss and occur mostly in the posterior regions and that most patients showing parafunctional habits also have implant fracture. Abutment and gold screw loosening or fracture were also observed in some of the cases previous to implant fracture. Similar observations were seen in our hospital as well. The following cases will present implant fracture cases which have been successfully treated regarding function and biomechanics. This was achieved by means of using increased number of futures, increasing fixture diameter and establishing proper occlusion.

  • PDF

기존 임플란트 보철물의 불량한 유지관리를 개선하기 위해 임플란트 피개의치로의 상부 보철물 전환 증례 (Rehabilitation of a patient by converting poorly maintained fixed implant prosthesis into implant overdenture: a case report)

  • 김영규;정창모;윤미정;이소현;허중보
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.127-134
    • /
    • 2022
  • 임플란트 실패의 경우에서 과도한 하중 및 염증이 실패율을 높이는 대표적인 원인이 된다. 특히, 임플란트 주변의 불량한 구강위생은 임플란트 실패의 가장 흔한 원인 중 하나이다. 임플란트 상부보철물의 실패가 발생할 경우, 임상의는 남은 고정체를 사용하여 재진단하고 평가하여 치료계획을 수립해야 한다. 임플란트를 추가 식립하여 새로운 보철물을 만들거나 남은 임플란트를 이용하여 임플란트 융합 가철성 의치 및 임플란트 피개의치로 치료를 시행할 수 있다. 본 증례의 환자는 상악 무치악부를 고정성 임플란트 보철물로 수복한 후 구강위생관리가 불가하여 임플란트 보철물 실패한 환자에서 잔존 임플란트의 지대주 및 부가적인 유지 장치를 장착한 milled bar를 이용하여 가철성 임플란트 피개의치로 전환하여 치료하였고 심미성과 저작기능, 지속적인 유지관리 면에서 장기적으로 만족할 만한 결과를 얻었기에 보고하는 바이다.

슬관절 전치환술에서 후방 안정 임플란트의 오정렬이 경골 기둥에 미치는 영향 (Influence of Malalignment on Tibial Post in Total Knee Replacement Using Posterior Stabilized Implant)

  • 김상훈;안옥균;배대경;김윤혁;김경수;이순걸
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.108-116
    • /
    • 2007
  • Recently, it has been reported that the posterior stabilized implant, which is clinically used for the total knee replacement (TKR), may have failure risk such as wear or fracture by the contact pressure and stress on the tibial post. The purpose of this study is to investigate the influence of the mal alignment of the posterior stabilized implant on the tibial post by estimating the distributions of contact pressure and von-Mises stress on a tibial post and to analyze the failure risk of the tibial post. Finite element models of a knee joint and an implant were developed from 1mm slices of CT images and 3D CAD software, respectively. The contact pressure and the von-Mises stress applying on the implant were analyzed by the finite element analysis in the neutral alignment as well as the 8 malalignment cases (3 and 5 degrees of valgus and varus angulations, and 2 and 4 degrees of anterior and posterior tilts). Loading condition at the 40% of one whole gait cycle such as 2000N of compressive load, 25N of anterior-posterior load, and 6.5Nm of torque was applied to the TKR models. Both the maximum contact pressure and the maximum von-Mises stress were concentrated on the anterior-medial region of the tibial post regardless of the malalignment, and their magnitudes increased as the degree of the malalignment increased. From present result, it is shown that the malalignment of the implant can influence on the failure risk of the tibial post.

디지털 인상채득을 이용한 소구증을 가진 환자의 전악 임플란트 수복 (Digital impression taking for full-arch implant restoration to a patient with microstomia)

  • 심지석;류재준
    • 대한치과의사협회지
    • /
    • 제56권11호
    • /
    • pp.616-621
    • /
    • 2018
  • This clinical case highlights the failure of long length implants, and the prosthodontic procedures necessary to rehabilitate the maxillary dentition of a patient with microstomia. The integrated digital technology of intra-oral scanning, computer-aided design, and three-dimensional printing can provide an alternative method to make conventional impressions for patients with microstomia who cannot insert the appropriate tray in their mouths.

  • PDF

Do Certain Conditions Favor the Use of Autogenous Bone Graft Over Bone Substitutes for Maxillary Sinus Augmentation?

  • Lee, Ji-Hyun;Cho, Yeong-Cheol;Sung, Iel-Yong;Choi, Jong-Ho;Son, Jang-Ho
    • Journal of Korean Dental Science
    • /
    • 제12권2호
    • /
    • pp.48-57
    • /
    • 2019
  • Purpose: To investigate whether there are specific surgical or clinical conditions where the use of autogenous bone (AB) is superior to the use of bone substitutes (BSs) for maxillary sinus floor augmentation (MSFA). Materials and Methods: We retrospectively analyzed 386 implants after MSFA in 178 patients. The implants were divided into five groups according to the sinus graft material used. Risk factors for implant failure in MSFA, and correlation between residual bone height (RBH) and graft materials in terms of implant survival were investigated. To investigate risk factors for implant failure in MSFA, implant survival according to graft materials, patients' sex/age, surgical site, RBH, healing period prior to prosthetic loading, staged- or simultaneous implantation with MSFA, the crown-to-implant ratio, prosthetic type, implant diameter, and opposite dentition were evaluated. Result: The cumulative 2- and 5-year survival rates of implants placed in the grafted sinus (independent of the graft material used) were 98.7% and 97.3%, respectively. None of the investigated variables were identified as significant risk factors for implant failure. There was also no statistical significance in implant survival between graft materials. Conclusion: There were no specific surgical conditions in which AB was superior to BSs in terms of implant survival after MSFA.