• Title/Summary/Keyword: impedance-based method

Search Result 603, Processing Time 0.03 seconds

Microstructure and Electrical Properties of ZnO-Zn2BiVO6-Mn3O4 Varistor (ZnO-Zn2BiVO6-Mn3O4 바리스터의 미세구조와 전기적 특성)

  • Hong, Youn-Woo;Ha, Man-Jin;Paik, Jong-Hoo;Cho, Jeong-Ho;Jeong, Young-Hun;Yun, Ji-Sun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.5
    • /
    • pp.313-319
    • /
    • 2018
  • This study introduces a new investigation report on the microstructural and electrical property changes of $ZnO-Zn_2BiVO_6-Mn_3O_4$ (ZZMn), where 0.33 mol% of $Mn_3O_4$ and 0.5 mol% of $Zn_2BiVO_6$ were added to ZnO (99.17 mol%) as liquid phase sintering aids. $Zn_2BiVO_6$ contributes to the decrease of sintering temperatures by up to $800^{\circ}C$, and segregates its particles at the grain boundary, while $Mn_3O_4$ enhances ${\alpha}$, the nonlinear coefficient, of varistor properties up to ${\alpha}=62$. In comparison, when the sintering temperature is increased from $800^{\circ}C$ to $1,000^{\circ}C$, the resistivity of ZnO grains decreases from $0.34{\Omega}cm$ to $0.16{\Omega}cm$, and the varistor property degrades. Oxygen vacancy ($V_o^{\bullet}$) (P1, 0.33~0.36 eV) is formed as a dominant defect. Two different kinds of grain boundary activation energies of P2 (0.51~0.70 eV) and P3 (0.70~0.93 eV) are formed according to different sintering temperatures, which are tentatively attributed to be $ZnO/Zn_2BiVO_6$-rich interface and ZnO/ZnO interface, respectively. Accordingly, this study introduces a progressive method of manufacturing ZnO chip varistors by way of sintering ZZMn-based varistor under $900^{\circ}C$. However, to procure a higher reliability, an in-depth study on the multi-component varistors with double-layer grain boundaries should be executed.

The Characteristics analysis of a Flux-lock Type Fault Current Limiter according to the Winding Directions for Power Grid (전력계통 적용을 위한 결선방향에 따른 자속구속형 한류기의 특성 분석)

  • Lee, Mi-Yong;Park, Jeong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5879-5884
    • /
    • 2013
  • With the rapid industrialization and economical development, the electricity demands of the industrial facilities and densely populated large cities are continuing to increase in Korea. The increase in the power consumption requires the extension of power facilities, but it is difficult to secure spaces for equipment installation in the limited space of urban areas. In addition, the 154 kV or 345 kV transmission systems in Korea has a short transmission distance, and are connected to one another in network structures that ensure the high reliability and stability of power supply. This structure reduces the impedance during the fault in power system, and increases the magnitude of in the short circuit fault current. The superconducting fault current limiter (SFCL) was devised to effectively address these existing problems. The SFCL is a new-concept eco-friendly protective device that ensures fast operation and recovery time for the fault current and does not need additional fault detection devices. Therefore, many studies are being conducted around the world. In this paper, based on the wiring method the initial fault current characteristics, current limiting characteristics, according to the incident angle and the change in inductance current limiting characteristics were analyzed in a multifaceted methods.

The Relationships between UCP-1 Polymorphism and the Degree of Obesity or Plasma Lipid Profile in Prepubertal Children (소아에서의 UCP-1 다형성과 비만도 및 혈액 지질수치와의 관련성에 관한 연구)

  • Oh, Hyun-Hee;Shin, Eun-Jung;Lee, Myoung-Sook
    • Journal of Nutrition and Health
    • /
    • v.41 no.8
    • /
    • pp.767-775
    • /
    • 2008
  • Uncoupling protein-1 (UCP-1) plays a major role in thermogenesis at brown adipose tissues and has been implicated in the pathogenesis of obesity and metabolic disorders. The purpose of this study was to estimate the effects of A-3826G polymorphism in 117 Korean prepubertal children aged 8-11 years olds. Anthropometry by bioelectrical impedance analysis method, plasma lipid profiles by auto-biochemical analyzer and UCP-1 genotyping by PCR-RFLP were done. The frequencies of UCP-1 genotypes were AA; 17.7%, AG; 57.8%, GG; 26.6%. The frequencies of each G allele (55.5%) was similar to Japanese's (49%) and higher than Caucacian's (25%). No correlation UCP-1 polymorphism and BMI (kg/$m^2$) or the degree of obesity described by the relative percentiles of the standard weight according to height in prepubertal children. However, plasma total- and LDL-cholesterol were significantly increased in G allele when sex, age and weight were adjusted. Our results suggested that G allele of UCP-1 gene was stronger risk factors in hyperLDLcholesterolemia than A allele. This impact might be progressed as the precaution against the revalence of obesity based-metabolic disease.

Three Dimensional Implementation of Intelligent Transportation System Radio Frequency Module Packages with Pad Area Array (PAA(Pad Area Array)을 이용한 ITS RF 모듈의 3차원적 패키지 구현)

  • Jee, Yong;Park, Sung-Joo;Kim, Dong-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.1
    • /
    • pp.13-22
    • /
    • 2001
  • This paper presents three dimensional structure of RF packages and the improvement effect of its electrical characteristics when implementing RF transceivers. We divided RF modules into several subunits following each subunit function based on the partitioning algorithm which suggests a method of three dimension stacking interconnection, PAA(pad area array) interconnection and stacking of three dimensional RF package structures. 224MHz ITS(Intelligent Transportation System) RF module subdivided into subunits of functional blocks of a receiver(RX), a transmitter(TX), a phase locked loop(PLL) and power(PWR) unit, simultaneously meeting the requirements of impedance characteristic and system stability. Each sub­functional unit has its own frequency region of 224MHz, 21.4MHz, and 450KHz~DC. The signal gain of receiver and transmitter unit showed 18.9㏈, 23.9㏈. PLL and PWR modules also provided stable phase locking, constant voltages which agree with design specifications and maximize their characteristics. The RF module of three dimension stacking structure showed $48cm^3$, 76.9% reduction in volume and 4.8cm, 28.4% in net length, 41.8$^{\circ}C$, 37% in maximum operating temperature, respectively. We have found that three dimensional PAA package structure is able to produce high speed, high density, low power characteristics and to improve its functional characteristics by subdividing RF modules according to the subunit function and the operating frequency, and the features of physical volume, electrical characteristics, and thermal conditions compared to two dimensional RF circuit modules.

  • PDF

Evaluation of Soil-Structure Interaction Responses of LNG Storage Tank Subjected to Vertical Seismic Excitation Depending on Foundation Type (기초형식에 따른 LNG 저장탱크의 지반-구조물 상호작용을 고려한 수직방향 지진응답 분석)

  • Son, Il-Min;Kim, Jae-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.367-374
    • /
    • 2019
  • We investigate the effect of soil-structure interaction (SSI) on the response of LNG storage tanks to vertical seismic excitation depending on the type of foundation. An LNG storage tank with a diameter of 71 m on a clay layer with a thickness of 30 m upon bedrock, was selected as an example. The nonlinear behavior of the soil was considered in an equivalent linear method. Four types of foundation were considered, including shallow, piled raft, and pile foundations (surface and floating types). In addition, the effect of soil compaction within the group pile on the seismic response of the tank was investigated. KIESSI-3D, an analysis package in the frequency domain, was used to study the SSI and the stress in the outer tank was calculated. Based on an analysis of the numerical results, we arrived at three main conclusions: (1) for a shallow foundation, the vertical stress in the outer tank is less than the fixed base response due to the SSI effect; (2) for foundations supported by piles, the vertical stress can be greater than the fixed base stress due to the increase in the vertical impedance due to the piles and the decrease in radiation damping; and (3) soil compaction had a miniscule impact on the seismic response of the outer tank.

Development of Disposable Immunosensors for Rapid Determination of Sildenafil and Vardenafil in Functional Foods

  • Vijayaraj, Kathiresan;Lee, Jun Hyuck;Kim, Hyung Sik;Chang, Seung-Cheol
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.83-88
    • /
    • 2017
  • We introduced disposable amperometric immunosensors for the detection of Sildenafil and Vardenafil (SDF/VDF) based on screen printed carbon electrodes. The developed immunosensors were used as a non-competitive sandwich-type enzyme immunoassay with a horseradish peroxidase label. The sensors were constructed on screen printed carbon electrodes by the simple electrochemical deposition of a reduced graphene oxide and chitosan (ErGO-CS) composite. To evaluate the sensing chemistry and optimize the sensor characteristics, a series of electrochemical experiments were carried out including electrochemical impedance spectroscopy, cyclic voltammetry and amperometry. The sensors showed a linear response to SDF/VDF concentrations in a range from 100 pg/mL to 300 ng/mL. The lower detection limit was calculated to be 55 pg/mL, the sensitivity was calculated to be $1.02{\mu}Ang/mL/cm^2$, and the sensor performance exhibited good reproducibility with a relative standard deviation (RSD) of 7.1%. The proposed sensing chemistry strategy and the sensor format can be used as a simple, cost-effective, and feasible method for the in-field analysis of SDF/VDF in functional or health supplement food samples.

Analysis and verification of the characteristic of a compact free-flooded ring transducer made of single crystals (압전단결정을 이용한 소형 free-flooded ring 트랜스듀서의 성능 특성 예측 및 검증)

  • Im, Jongbeom;Yoon, Hongwoo;Kwon, Byungjin;Kim, Kyungseop;Lee, Jeongmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.278-286
    • /
    • 2022
  • In this study, a 33-mode Free-Flooded Ring (FFR) transducer was designed to apply piezoelectric single crystal PIN-PMN-PT, which has high piezoelectric constants and electromechanical coupling coefficient. To ensure low-frequency high transmitting sensitivity characteristics with a small size of FFR transducer, the commercial FFR transducer based on piezoelectric ceramics was compared. To develop the FFR transducer with broadband characteristics, a piezoelectric segmented ring structure inserted with inactive elements was applied. The oil-filled structure was applied to minimize the change of acoustic characteristics of the ring transducer. It was verified that the transmitting voltage response, underwater impedance, and beam pattern matched the finite element numerical simulation results well through an acoustic test. The difference in the transmitting voltage response between the measured and the simulated results is about 1.3 dB in cavity mode and about 0.3 dB in radial mode. The fabricated FFR transducer had a higher transmitting voltage response compared to the commercial transducer, but the diameter was reduced by about 17 %. From this study, it was confirmed that the feasibility of a single crystal-applied FFR transducer with compact size and high-power characteristics. The effectiveness of the performance prediction by simulation was also confirmed.

Miniaturization of GPS Microstrip Antenna for Small Drone (초소형 드론 탑재용 GPS 대역 마이크로스트립 안테나의 소형화)

  • Kim, Wan-Ki;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.3
    • /
    • pp.62-72
    • /
    • 2022
  • In this study, a miniaturized GPS band(L1 : 1.575 GHz) antenna that can be mounted on a small drone is proposed. The miniaturization was designed by applying the perturbation method based on the λ/4 microstrip antenna and lengthening the current path at the edge of the patch. The miniaturized antenna was fabricatred such that it could be attached to the surface of styrofoam(εr=1.06, t=10 mm) having a size of 10 mm × 9 mm × 10 mm (0.05 λ × 0.05 λ × 0.05 λ). The thickness and length of the feeding line and the spacing between short stubs were adjusted for impedance matching. S11 was found to be -18.8 dB at the center frequency of the fabricated antenna, 1.575 GHz. The radiation pattern measurement results show that the maximum gain of Eθ is 1.87 dBi in 0 directions in the xz-plane, and that Eθ is an omnidirectional characteristic with an average gain of -1.7 dBi in the yz-plane. It was found that the antenna can be used as an ultra-small microstrip antenna, which can be mounted on a small dron for GPS, and is capable of preserving a reduction ratio of 98.8% as compared to a λ/2 microstrip patch antenna.

A Non-enzymatic Hydrogen Peroxide Sensor Based on CuO Nanoparticles/polyaniline on Flexible CNT Fiber Electrode (CuO Nanoparticles/polyaniline/CNT fiber 유연 전극 기반의 H2O2 검출용 비효소적 전기화학 센서)

  • Min-Jung Song
    • Korean Chemical Engineering Research
    • /
    • v.61 no.2
    • /
    • pp.196-201
    • /
    • 2023
  • In this study, a CNT fiber flexible electrode grafted with CuO nanoparticles (CuO NPs) and polyaniline (PANI) was developed and applied to a nonenzymatic electrochemical sensor for H2O2 detection. CuO NPs/PANI/CNT fiber electrode was fabricated through the synthesis and deposition of PANI and CuO NPs on the CNT fiber surface using an electrochemical method. Surface morphology and elemental composition of the CuO NPs/PANI/CNT fiber electrode were characterized by scanning electron microscope with energy dispersive X-ray spectrometry. And its electrochemical characteristics were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA). Compared with a bare CNT fiber as a control group, the CuO NPs/PANI/CNT fiber electrode showed a 4.78-fold increase in effective surface area and a 8.33-fold decrease in electron transfer resistance, which leads to excellent electrochemical properties such as a good electrical conductivity and an efficient electron transfer. These improved characteristics were due to the synergistic effect through the grafting of CNT fiber, PANI and CuO NPs. As a result, this electrode enhanced the H2O2 sensing performance.

Plasma D-dimer Determination in the Diagnosis of Pulmonary Embolism (폐색전증의 진단에 있어 혈청 D-dimer 측정의 진단적 가치)

  • Lim, Chae-Man;Kim, Hong-Kyu;Choi, Kang-Hyun;Lee, Sand-Do;Koh, Youn-Suck;Kim, Woo-Sung;Jang, Jae-Suck;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.69-74
    • /
    • 1996
  • Background: The diagnosis of pulmonary embolism (PE) based on clinical findings is often elusive and therefore requires confirmative diagnostic method. Pulmonary angiography, though the gold standard for the diagnosis of pulmonary embolism, is an invasive method and requires trained personnel and special equipment. Lung V/Q scan, on the other hand, is a noninvasive method but the diagnostic specificity and sensitivity arc not satisfactory in case that the results are either intermediate or low probability scan. Plasma D-dimer is generated when a thrombus is fibrinolysed by plasmin and is known to be increased in various thrombotic disorders. The aim of this study was to investigate the value of the determination of plasma D-dimer level in the diagnosis of pulmonary embolism. Methods: Pulmonary angiography was performed in 17 patients who were clinically suspected to have pulmonary embolism. 9 patients(PE, $56{\pm}13.4$ yrs, M:F=8:1) were diagnosed to have pulmonary embolism by pulmonary angiography. The control group were the 8 patients with negative pulmonary angiography and 13 orthopedic patients with no evidence of pulmonary embolism on scintigraphic and impedance plethysmographic studies(n=21) (non-PE, $54.5{\pm}11.1$ yrs, M:F=11:10). Plasma D-dimer was measured by latex agglutination method in study subjects and the results were analyzed according to the presence or absence of pulmonary embolism. Results: 1) The increased level of plasma D-dimer was more frequently observed in the patients with pulmonary embolism than in the controls(>0.5 mg/L, 8 in PE, 10 in non-PE; <0.5 mg/L, 1 in PE, 11 in non-PE, p=0.049). 2) The diagnostic value of plasma D-dimer level higher than 0.5 mg/L were as follows: sensitivity 88.9%(8/9), specificity 52.4%(11/21), positive predictive value 44.4%(8/18), and negative predictive value 91.7%(11/12). Conclusion: Plasma D-dimer determination showed high sensitivity and negative predictive value in the diagnosis of pulmonary embolism and is therefore thought to be useful in excluding the possibility of pulmonary embolism.

  • PDF