• 제목/요약/키워드: impedance signatures

검색결과 38건 처리시간 0.024초

Temperature effect on wireless impedance monitoring in tendon anchorage of prestressed concrete girder

  • Park, Jae-Hyung;Huynh, Thanh-Canh;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제15권4호
    • /
    • pp.1159-1175
    • /
    • 2015
  • In this study, the effect of temperature variation on the wireless impedance monitoring is analyzed for the tendon-anchorage connection of the prestressed concrete girder. Firstly, three impedance features, which are peak frequency, root mean square deviation (RMSD) index, and correlation coefficient (CC) index, are selected to estimate the effects of temperature variation and prestress-loss on impedance signatures. Secondly, wireless impedance tests are performed on the tendon-anchorage connection for which a series of temperature variation and prestress-loss events are simulated. Thirdly, the effect of temperature variation on impedance signatures measured from the tendon-anchorage connection is estimated by the three impedance features. Finally, the effect of prestress-loss on impedance signatures is also estimated by the three impedance features. The relative effects of temperature variation and prestress-loss are comparatively examined.

Quantitative damage identification in tendon anchorage via PZT interface-based impedance monitoring technique

  • Huynh, Thanh-Canh;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제20권2호
    • /
    • pp.181-195
    • /
    • 2017
  • In this study, the severity of damage in tendon anchorage caused by the loss of tendon forces is quantitatively identified by using the PZT interface-based impedance monitoring technique. Firstly, a 2-DOF impedance model is newly designed to represent coupled dynamic responses of PZT interface-host structure. Secondly, the 2-DOF impedance model is adopted for the tendon anchorage system. A prototype of PZT interface is designed for the impedance monitoring. Then impedance signatures are experimentally measured from a laboratory-scale tendon anchorage structure with various tendon forces. Finally, damage severities of the tendon anchorage induced by the variation of tendon forces are quantitatively identified from the phase-by-phase model updating process, from which the change in impedance signatures is correlated to the change in structural properties.

Wireless Impedance-Based SUM for Bolted Connections via Multiple PZT-Interfaces

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • 비파괴검사학회지
    • /
    • 제31권3호
    • /
    • pp.246-259
    • /
    • 2011
  • This study presents a structural health monitoring (SHM) method for bolted connections by using multi-channel wireless impedance sensor nodes and multiple PZT-interfaces. To achieve the objective, the following approaches are implemented. Firstly, a PZT-interface is designed to monitor bolt loosening in bolted connection based on variation of electro-mechanical(EM) impedance signatures. Secondly, a wireless impedance sensor node is designed for autonomous, cost-efficient and multi-channel monitoring. For the sensor platform, Imote2 is selected on the basis of its high operating speed, low power requirement and large storage memory. Finally, the performance of the wireless sensor node and the PZT-interfaces is experimentally evaluated for a bolt-connection model Damage monitoring method using root mean square deviation(RMSD) index of EM impedance signatures is utilized to estimate the strength of the bolted joint.

잡음 환경 하에서의 전기-역학적 임피던스 기반 조류발전 구조물의 장기 건전성 모니터링 (Impedance-based Long-term Structural Health Monitoring for Tidal Current Power Plant Structure in Noisy Environments)

  • 민지영;심효진;윤정방;이진학
    • 한국해양공학회지
    • /
    • 제25권4호
    • /
    • pp.59-65
    • /
    • 2011
  • In structural health monitoring (SHM) using electro-mechanical impedance signatures, it is a critical issue for extremely large structures to extract the best damage diagnosis results, while minimizing unknown environmental effects, including temperature, humidity, and acoustic vibration. If the impedance signatures fluctuate because of these factors, these fluctuations should be eliminated because they might hide the characteristics of the host structural damages. This paper presents a long-term SHM technique under an unknown noisy environment for tidal current power plant structures. The obtained impedance signatures contained significant variations during the measurements, especially in the audio frequency range. To eliminate these variations, a continuous principal component analysis was applied, and the results were compared with the conventional approach using the RMSD (Root Mean Square Deviation) and CC (Cross-correlation Coefficient) damage indices. Finally, it was found that this approach could be effectively used for long-term SHM in noisy environments.

가속도 및 임피던스 신호를 이용한 PSC 거더교의 하이브리드 손상 모니터링 체계 (Hybrid Damage Monitoring Scheme of PSC Girder Bridges using Acceleration and Impedance Signature)

  • 김정태;박재형;홍동수;나원배
    • 대한토목학회논문집
    • /
    • 제28권1A호
    • /
    • pp.135-146
    • /
    • 2008
  • 본 논문에서는 가속도 및 임피던스 신호를 이용하여 프리스트레스트 콘크리트(PSC) 거더교에 적합한 하이브리드 손상 모니터링 체계를 제안하였다. PSC 거더교의 주된 손상유형으로 텐던의 긴장력 감소와 콘크리트 거더의 휨 강성 저하를 고려하였다. 제안된 하이브리드 체계는 손상경보, 손상분류 및 손상평가와 같이 크게 3단계로 구성하였다. 첫 번째 단계에서는 가속도 특성 변화를 모니터링하여 전역적인 손상의 발생을 경보한다. 두 번째 단계에서는 임피던스 특성 변화를 모니터링하여 손상유형이 긴장력 감소인지 휨 강성 저하인지를 분류한다. 세 번째 단계에서는 손상유형에 적합한 손상평가기법을 이용하여 손상의 위치와 크기를 평가한다. 손상유형이 휨 강성 저하인 경우에서는 모드형상기반 손상검색 기법을 적용하였고, 손상유형이 긴장력 감소인 경우에서는 고유진동수기반 긴장력 추정 기법을 적용하였다. 모형 PSC 거더 실험을 통해 제안된 하이브리드 손상모니터링 체계의 유용성을 평가하였다.

무선 임피던스 센서노드를 이용한 강-볼트 접합부의 임피던스기반 손상모니터링에 미치는 온도 영향 (Temperature Effect on Impedance-based Damage Monitoring of Steel-Bolt Connection using Wireless Impedance Sensor Node)

  • 홍동수;김정태
    • 한국해양공학회지
    • /
    • 제26권1호
    • /
    • pp.27-33
    • /
    • 2012
  • This paper presents the effect of temperature on the impedance-based damage monitoring of steel-bolt connections using wireless impedance sensor nodes. In order to achieve the objective, the following approaches are implemented. First, a temperature-compensated damage monitoring scheme that includes a temperature compensation model and damage detection method is described. The temperature compensation model is designed by analyzing the linear regressions between the temperatures and impedance signatures. The correlation coefficient of the impedance signatures is selected as the damage index to monitor the damage occurrence in the target structures. Second, a wireless impedance sensor node is described for the design of the hardware components and embedded software. Finally, the performance of the temperature-compensated impedance-based damage monitoring scheme is evaluated for detecting a loose bolt in the steel-bolt connections on a lab-scale steel girder under various temperatures.

Smart sensors for monitoring crack growth under fatigue loading conditions

  • Giurgiutiu, Victor;Xu, Buli;Chao, Yuh;Liu, Shu;Gaddam, Rishi
    • Smart Structures and Systems
    • /
    • 제2권2호
    • /
    • pp.101-113
    • /
    • 2006
  • Structural health monitoring results obtained with the electro-mechanical (E/M) impedance techniqueand Lamb wave transmission methods during fatigue crack propagation of an Arcan specimen instrumented with piezoelectric wafer active sensors (PWAS) are presented. The specimen was subjected in mixed-mode fatigue loading and a crack was propagated in stages. At each stage, an image of the crack and the location of the crack tip were recorded and the PWAS readings were taken. Hence, the crack-growth in the specimen could be correlated with the PWAS readings. The E/M impedance signature was recorded in the 100 - 500 kHz frequency range. The Lamb-wave transmission method used the pitch-catch approach with a 3-count sine tone burst of 474 kHz transmitted and received between various PWAS pairs. Fatigue loading was applied to initiate and propagate the crack damage of controlled magnitude. As damage progressed, the E/M impedance signatures and the waveforms received by receivers were recorded at predetermined intervals and compared. Data analysis indicated that both the E/M impedance signatures and the Lamb-wave transmission signatures are modified by the crack progression. Damage index values were observed to increase as the crack damage increases. These experiments demonstrated that the use of PWAS in conjunction with the E/M impedance and the Lamb-wave transmission is a potentially powerful tool for crack damage detection and monitoring in structural elements.

Impedance-Based Damage Diagnosis on Bolt-Jointed Structure Under Varying Temperature

  • Shim, Hyo-Jin;Min, Ji-Young;Yun, Chung-Bang;Shin, Sung-Woo
    • 비파괴검사학회지
    • /
    • 제31권3호
    • /
    • pp.260-270
    • /
    • 2011
  • The electromechanical impedance(E/M)-based method detects local structural damages based on variations of electrical impedance signatures which are obtained from piezoelectric sensors bonded to the structure and excited in high frequency band. In this method, temperature changes may result in significant impedance variations and lead to erroneous diagnostic results of the structure. To tackle this problem, a new technique providing a 2-dimensional damage feature related to the temperature information is proposed to distinguish the structural damage from the undesirable temperature variation. For experimental tests to validate the proposed method, damages are introduced by bolt loosening to a bolt-jointed steel beam, and impedance signals are measured under varying temperature conditions through a piezoelectric sensor attached on the beam. A freely suspended piezoelectric sensor is additionally utilized to obtain temperature information indirectly from resistance signatures. From a relationship between the damage index (from a constrained sensor) and the temperature (from a freely suspended sensor or a temperature sensor), damages can be detected more clearly under varying temperature compared to other conventional approaches.

Impedance-based health monitoring and mechanical testing of structures

  • Palomino, Lizeth Vargas;de Moura, Jose Dos Reis Vieira Jr.;Tsuruta, Karina Mayumi;Rade, Domingos Alves;Steffen, Valder Jr.
    • Smart Structures and Systems
    • /
    • 제7권1호
    • /
    • pp.15-25
    • /
    • 2011
  • The mechanical properties obtained from mechanical tests, such as tensile, buckling, impact and fatigue tests, are largely applied to several materials and are used today for preliminary studies for the investigation of a desired element in a structure and prediction of its behavior in use. This contribution focus on two widely used different tests: tensile and fatigue tests. Small PZT (Lead Titanate Zirconate) patches are bonded on the surface of test samples for impedance-based health monitoring purposes. Together with these two tests, the electromechanical impedance technique was performed by using aluminum test samples similar to those used in the aeronautical industry. The results obtained both from tensile and fatigue tests were compared with the impedance signatures. Finally, statistical meta-models were built to investigate the possibility of determining the state of the structure from the impedance signatures.

판형교의 가속도-임피던스 신호를 이용한 하이브리드 손상 모니터링 기법 (Hybrid Damage Monitoring Technique for Plate Girder Bridges using Acceleration-Impedance Signatures)

  • 홍동수;조현만;나원배;김정태;박규해
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.197-202
    • /
    • 2008
  • In this paper, a hybrid vibration-impedance approaches is newly proposed to detect the occurrence of damage, the location of damage, and extent of damage in steel plate-girder bridges. The hybrid scheme mainly consists of three sequential phases: 1) to alarm the occurrence of damage, 2) to classify the alarmed damage, and 3) to estimate the classified damage in detail. Damage types of interest include flexural stiffness-loss in girder and bolts-loose in supports. In the first phase, the global occurrence of damage is alarmed by monitoring changes in acceleration features. In the second phase, the alarmed damage is classified into subsystems by recognizing patterns of impedance features. In the final phase, the location and the extent of damage are estimated by using modal strain energy-based damage index method and root mean square deviation method. The feasibility of the proposed system is evaluated on a laboratory-scaled steel plate-girder bridge model for which hybrid vibration-impedance signatures were measured for several damage scenarios.

  • PDF