• Title/Summary/Keyword: impedance matrix

Search Result 198, Processing Time 0.022 seconds

A Study on the Sound Absorption of Multiple Layer Perforated Plate Systems Combined with Porous Absorbing Materials (다공성 흡음재가 조합된 다중 다공판 시스템의 흡음성능에 관한 연구)

  • Heo, Sung-Wook;Kim, Wook;Lee, Dong-Hoon;Kwon, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.896-901
    • /
    • 2002
  • The sound absorption coefficients for multiple layer perforated plate systems containing several compartments with airspaces and porous absorbing materials are estimated using the transfer matrix method developed in the previous paper. The absorption coefficients from transfer matrix method agree well with the values measured by the two-microphone impedance tube method for various combinations of perforated plates, airspaces or porous materials. Based on these results, a guidance for the design of multiple layer perforated plate systems combined with airspaces and porous absorbing materials is discussed in detail.

  • PDF

A Study on the Acoustic Properties of Porous Material by Using Acoustic Transfer Matrix (전달행렬법에 의한 다공질 흡음재의 음향특성 연구)

  • 박철희;주재만;염창훈
    • Journal of KSNVE
    • /
    • v.6 no.5
    • /
    • pp.635-644
    • /
    • 1996
  • In this paper, Allard's modelling method which employs the method of acoustic transfer matrix(ATM) is applied to yield more precise results in the analysis of porous sound absorbing material. The method of ATM, based on Biot's theory, is known to play an important role in the estimation of the sound absorption when a sound projects onto the material. In the case of a single layered porous sound absorbing material, the surface impedance and the absorption coefficient by using the method of ATM are estimated. With the variation of the material properties, sound absorption characteristics and analyzed. Transmission Loss in a combination of the porous sound absorbing material with a thin plate is predicted.

  • PDF

A study of Modifying Bus Impedance Matrix for Node Seperation (노드분할에 대한 모선 임피던스 행열 수정방법 연구)

  • Oh, Yong-Taek;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.6-8
    • /
    • 1993
  • Short Circuit analysis is one of the most fundamental procedures for power system analysis problem. In order 10 solve the problem, In order to solve the problem, it's required to develop an advanced algorithm by which modified bus admittance matrix are easily computed for a large number of alternative network configuration. This paper proposes a new calculation method to efficiently modify the bus impedance matrix elements of large power system by method for removal of link, and presents its Practicality by applying the proposed method in the power system model.

  • PDF

A Study on the Sound Absorption of Multiple Layer Perforated Plate Systems Combined with Porous absorbing Materials (다공성 흡음재가 조합된 다중 다공판 시스템의 흡음성능에 관한 연구)

  • Heo, Sung-Wook;Lee, Dong-Hoon;Kim, Wook;Kwon, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.388.1-388
    • /
    • 2002
  • The sound absorption coefficients for multiple layer perforated plate systems containing several companments with airspaces and porous absorbing materials are estimated using the transfer matrix method developed in the previous paper. The absorption coefficients from transfer matrix method agree well with the values measured by the two-microphone impedance tube method fur various combinations of perforated Plates, airspaces or porous materials. (omitted)

  • PDF

A New Estimation Model of Predicting the Sound Absorption Performance for Multiple Perforated Plate Systems (다중 다공판 시스템의 흡음성능 예측을 위한 계산모델 개발)

  • 허성춘;이동훈;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.877-882
    • /
    • 2002
  • A new estimation model of predicting the sound absorption performance for multiple perforated plate sound absorbing system was developed using transfer matrix method. The proposed method was validated by comparing the calculated absorption coefficients of a single layer perforated plate with the values measured by the two-microphone impedance tube method far various porosity and cavity depth. The developed transfer matrix method was further applied to estimate the multiple layer perforated plates and it is shown that the estimated absorption coefficients generally agree well with the measured values.

  • PDF

Online DCIR Estimation for Series-connected Battery Cells using Matrix-Switched Capacitor Converter

  • La, Phuong-Ha;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.381-382
    • /
    • 2020
  • In the battery energy storage system, battery cells are connected in series to increase the operating voltage. Due to the difference in characteristics, the performance degradation of cells is dissimilar. This paper proposes an online DC internal impedance estimation for battery cells in the series string using a matrix-switched capacitor converter, which is already verified as useful for the series balancing of the cells. The simulation in the hardware in the loop test rig shows good accuracy and the feasibility of the proposed method.

  • PDF

A Study on the Compensation of Transducer Effects for the Measurement of Vibration with an Impedance Head (임피턴스헤드로 진동계측시 변환기의 부착영향을 보상하는 방법에 관한 연구)

  • 이현엽;박재영
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.117-122
    • /
    • 1995
  • The transfer matrix method is proposed to compensate the attachment effect of a piezo-electric impedance head. To validate the proposed method, an experiment is carried out for axial vibration of a uniform rod for which an analytical solution is known. The impedance head is attached to the test rod by a stud and is connected to the exciter. The frequency response function is mesured by applying random excitation from the electro-magnetic exciter. The frequency response function compensated by the method proposed in this research shows good agreement with the analytical solution.

  • PDF

혈액정화장치의 현황과 문제점

  • 박한철
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.102-105
    • /
    • 1989
  • In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research.

  • PDF

Characteristics of Matrix Retaining Electrolyte in a Phosphoric Acid Fuel Cell Analyzed by A.C. Impedance Spectroscopy (복소임피던스법에 의한 인산형 연료전지용 전해질 매트릭스 특성)

  • 윤기현;장재혁;허재호;김창수;김태희
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.2
    • /
    • pp.189-196
    • /
    • 1995
  • Materials retaining electrolyte of a phosphoric acid fuel cell (PAFC) have been prepared with SiC powder to SiC whisker mixing ratios of 1:1, 1:2, 1:3, 1:4, 0:1 by a tape casting method. When 3wt% dispersant (sorbitan monooleate) is added to a matrix, the porosity of the matrix decreases a little while the bubble pressure and area of the matrix increase remarkably in comparison with no dispersant content. Effect of the electrolyte resistance and the polarization resistance on perfomance of a PAFC has been investigated using A.C. impedance spectroscopy. With the increase of whisker content, the electrolyte resistance decreases due to the increase of porosity and acid absorbancy, and the polarization resistance increases due to the increase of surface roughness. The polarization resistance affects current density predominantly at the higher potential than 0.7V becuase the polarization resistance is considrably larger than the electrolyte resistance. Both the electrolyte resistance and the polarization resistance affect current density near 0.7V of the fuel cell operating potential because they have similar values. The electrolyte resistance affects current density predominantly at the lower potential than the fuel cell operating potential because the electrolyte resistance is larger than the polarization resistance.

  • PDF

Direct Calculation of A Matrix in Multimachine Electric Power Systems (다수 발전기 계통의 A행렬 직접계산법)

  • Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.221-225
    • /
    • 1989
  • Direct calculation algorithm for the elements of A matrix in multimachine power systems with constant impedance loads has been suggested. Generator's rotor parameters need not be determined from the manufacturer's data. We can identify the elements of A matrix into two categories: One is related to only generator parameters, and the other is related to generator parameters, initial values, and $Z_{Bus}$ matrix.

  • PDF