• Title/Summary/Keyword: impedance controller

Search Result 172, Processing Time 0.031 seconds

Impedance Control of Backdrivable Hydraulic Actuation Systems with Explicit Disturbance Estimation (직접 외란 추정을 통한 역구동성 유압 구동 시스템의 임피던스 제어)

  • Yoo, Sunkyum;Chung, Wan Kyun
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.4
    • /
    • pp.348-356
    • /
    • 2019
  • The backdrivable servovalve is a desirable component for force and interaction control of hydraulic actuation systems because it provides direct force generation mechanical impedance reduction by its own inherent backdrivability. However, high parametric uncertainty and friction effects inside the hydraulic actuation system significantly degrade its advantage. To solve this problem, this letter presents a disturbance-adaptive robust internal-loop compensator (DA-RIC) to generate ideal interactive control performance from the backdrivable-servovalve-based system. The proposed control combines a robust internal-loop compensator structure (RIC) with an explicit disturbance estimator designed for asymptotic disturbance tracking, such that the controlled system provide stable and ideal dynamic behavior for impedance control, while completely compensating the disturbance effects. With the aid of a backdrivable servovalve, we show that the proposed control structure can be implemented based on a simplified nominal model, and the controller enables implementation without accurate knowledge of the target system parameters and disturbances. The performance and properties of the proposed controller are verified by simulation and experiments.

A Design and Implementation of Position Based Impedance Controller with Self-Adjusted Impedance Parameters (임피던스 파라미터의 자기 조절 기능을 갖는 위치 기반 임피던스 제어기의 설계 및 적용)

  • 황인호;박영칠
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.410-410
    • /
    • 2000
  • Impedance control is recognised as one of the most proper control scheme to carry out the assembly tasks, since it can control the dynamic relationship between the manipulator and environment directly. However, it is well known that the contact force cannot be controlled directly using the impedance control. Also impedance parameters should be properly defined depending on the task to be performed. We propose a new position based impedance control, which has self-adjusted impedance parameters and can control the contact force explicitly, Impedance parameters, as time-varying parameters, are adjusted automatically based on the measured contact force and the position error during the task. A proposed algorithm was implemented on the peg-in-hole task with the industrial manipulator. We shows the effectiveness of proposed control method experimentally.

  • PDF

Robust Impedance Control of Robot Manipulator Considering Time Delay (시간 지연을 고려한 로봇 매니퓰레이터의 강인한 임피던스 제어)

  • Kim, Jaehun;Hyunseok Shin;Park, Chang-Woo;Park, Mignon
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.39-42
    • /
    • 2000
  • In this paper we design the robust impedance controller of the robot manipulator with time delay. The designed controller considers time delay in the position loop and stabilizes the closed-loop system. The performance of a controller can be easily degraded by external disturbances. To improve the performance when external disturbances exist, we use the disturbance observer to handle the disturbances in the velocity loop and provide robustness to the control system. To show the validity of the designed controller, several experiments are performed for the 5-DOF robot manipulator equipped with the wrist force/torque sensor system.

  • PDF

Robust Discrete-Time Impedance Control of Robot Manipulator with Time Delay

  • Kim, Jaehun;Hyunseok Shin;Park, Chang-Woo;Park, Mignon
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.604-607
    • /
    • 2000
  • In this paper we design the robust impedance controller of the robot manipulator with time delay. The designed controller considers time delay in the position loop and stabilizes the closed-loop system. The performance of a controller can be easily degraded by external disturbances. To improve the performance when external disturbances exist, we use the disturbance observer to handle the disturbances in the velocity loop and provide robustness to the control system. To show the validity of the designed controller, several experiments are performed for the 5-DOF robot manipulator equipped with the wrist force/torque sensor system.

  • PDF

Controller with Voltage-Compensated Driver for Lighting Passive Matrix Organic Light Emitting Diodes Panels

  • Juan, Chang Jung;Tsai, Ming Jong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.673-675
    • /
    • 2004
  • This study proposes controller with voltage-compensated drivers for producing gray-scaled pictures on passive matrix organic light emitting diodes (PMOLEDs) panels. The controller includes voltage type drivers so the output impedance of the driver is far less than that of the current-type driver. Its low output impedance provides better electron-optical properties than those of traditional current drivers. A free running clock and a group of counters are applied to the gray-scaled function so that phase lock loop (PLL) circuit can be reduced in the controller. A pre-charge function is used to enhance performance of the luminance of an active OLED pixel. As a result, distribution of the low gray level portion is achieved linear relationship with input data. In this work, the digital part of the proposed controller is implemented using FPGA chips, and analog parts are combined with a digital-analog converter (DAC) and analog switches. A still image is displayed on a $48^{\ast}64$ PMOLEDs panel to assess the luminance performance fir the controller. Based on its cost requirement and luminance performance, the controller is qualified to join the market for driving PMOLEDs panels.

  • PDF

Modeling and Experiment of 50kW Diesel Generator in Grid-connected Mode (50kW 계통연계형 디젤발전기의 모델링 및 실험)

  • Lee, Wujong;Lee, Hak Ju;Chag, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1347-1353
    • /
    • 2014
  • This paper researches a modeling and experiment of 50kW diesel generator in grid-connected mode. The output of diesel generator can be calculated by the phase difference between voltage and current as well as the diesel generator parameter such as mutual impedance, field current and rotor angle. Considering the different d-q frame impedance, the output of diesel generator is analyzed for equation and verified by simulation. The diesel generator modeled by considering the time delay for actuator, diesel engine and exciter. The controller of diesel generator is divided into governor and exciter. The governor consists of speed controller and active power controller, where speed controller maintains frequency as 60Hz and active power tracks active power reference. On the other hand, the exciter consists of voltage controller and reactive power controller, where voltage controller controls $380V_{LL}$ and reactive power is controlled as zero. When the active power reference is changed as 0.1pu in the grid connected mode, the active power takes 10 seconds to reach the steady state and the reactive power is maintains as zero. The 50kW diesel generator is tested and experiment results are well matched with the simulation results.

Study on Measurement Technology for Equivalent Series Impedance of High-voltage Pulsed Power Capacitors (펄스파워용 고전압 커패시터 등가직렬 임피던스 측정에 관한 연구)

  • Lee, Byeong-Yoon;Lee, Byung-Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.937-942
    • /
    • 2013
  • Equivalent series impedance of high-voltage pulsed power capacitor is one of the important electrical characteristics both for users and for capacitor manufacturers because it may have serious effects on the performance of pulse forming circuits. In this paper, definition of equivalent series impedance and factors which generate equivalent series impedance are reviewed. Theoretical analysis for the calculation of equivalent series impedance based on differential measurement method is described and calculation program has been developed. In order to acquire data which are necessary to calculate equivalent series impedance from discharging current waveform, charging-dischargig controller has been manufactured. Measurement results of equivalent series impedance for high voltage pulsed power capacitor have been given.

Compliant motion controllers for kinematically redundant manipulators

  • Park, Jonghoon;Chung, Wan-Kyun;Youm, Youngil
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.456-459
    • /
    • 1995
  • The problem of compliant motion control using a redundant manipulator is addressed in this article. Specifically, a hybrid-control type and impedance-control type controllers are extended to general redundant manipulators based on the kinematically decomposed and geometrically compatible modeling of its joint space. In the case of the hybrid controller, it leads to the linear and decoupled closed-loop dynamics in the three motion spaces, that is the motion-controlled, force-controlled, and the null motion-controlled spaces of the redundant manipulator. When the proposed impedance controller is applied, the decoupled impedance models in three motion spaces are obtained. The superiority of the proposed controllers is verified with the numerical experiments.

  • PDF

Current Controlled PWN Inverter Using the Real-time Digital Feedback Control (실시간 디지털 궤환 제어(Deadbeat 제어)에 의한 전류 제어형 PWM 인버터에 관한 연구)

  • Lee, Jeong-Uk;Yoo, Ji-Yoon;Ahn, Ho-Gyun
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.259-267
    • /
    • 1994
  • This paper describes a current control of a single-phase PWM inverter. The proposed PWM inverter utilizes the instantaneous control method which is based on the real-time digital feedback control and the microprocessor-based deadbeat control. The deadbeat current controller is proposed to control the output current regardless of load component variations by the same method as voltage control. That is, in current control, with a very short sampling time and the successive feedback of the output current, the load current is mainly effected by the magnitude of load impedance rather than load component, the load current is mainly effected by the magnitude of load impedance rather than load component. Therefore, by treating the load as an impedance, the system's order is reduced and the instantaneous current control using the proposed deadeat controller is simplified.

Design of Torque Servo for Impedance Control of Double Vane Rotary Hydraulic Actuator System (더블 베인 회전형 유압 구동시스템의 임피던스 제어를 위한 토크 서보 설계)

  • Kim, Seon-Min;Choi, Young-Jin;Chung, Wan-Kyun
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.2
    • /
    • pp.160-168
    • /
    • 2010
  • In order to achieve a force controller with high performance, an accurate torque servo is required. However, the precise torque servo for a double vane rotary actuator system has not been developed till now, due to many nonlinear characteristics and system parameter variations. In this paper, the torque servo structure for the double vane rotary actuator system is proposed based on the torque model. Nonlinear equations are set up using dynamics of the double vane rotary hydraulic actuator system. Then, to derive the torque model, the nonlinear equations are linearized using a taylor series expansion. Both effectiveness and performance of the design of torque servo are verified by torque servo experiments and applying the suggested torque model to an impedance controller.