• Title/Summary/Keyword: impedance characteristics

Search Result 1,741, Processing Time 0.034 seconds

Design of Lowpass Filter With the Wide Stopband Characteristics Using Microstrip Line (마이크로스트립 선로를 이용한 광대역 차단특성을 가지는 저역통과 필터 설계)

  • Choi Dong-Muk;Shim Joon-Hwan;Jeon Joongn-Sung;Kim Dong-Il
    • Journal of Navigation and Port Research
    • /
    • v.30 no.5 s.111
    • /
    • pp.331-334
    • /
    • 2006
  • In this paper, we designed and fabricated the lowpass filter with the wide stopband characteristics using microp- strip line. Adding the $\lambda_g/4$ open stub at the input and output ports, we developed the L-C ladder type lowpass filter using the open stub which has wide stopband characteristics. In order to reduce the entire size qf this filter, the high impedance microstrip lines were made with the meander structure. The lowpass filter was fabricated with the cutoff frequency 2.3 GHz and its measured frequency responses agree well with the simulation results.

The effects of the shape of IDT electrode pair on the characteristics of SFIT filter (IDT형의 전극 형태가 SFIT형 필터의 특성에 미치는 영향)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2662-2670
    • /
    • 2009
  • The effect of the reflector type for the SAW filter on the characteristics of the slanted finger IDT filter have been studied by computer simulation. The IDT was evaporated by Aluminum-Copper alloy. The design condition was optimized by the phase shift of the SAWfilter for WCDMA. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness are $5,000{\AA}$, and the width and the space of reflector are $3.6{\mu}m$ and $2.0{\mu}m$, respectively. Frequency response of the fabricated SFIT filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 8.2MHz. And we could obtain that the return loss is less then 16dB, the ripple characteristics is probably 4dB and the triple transit echo is less then 18dB after when we have matched impedance.

Quench Characteristics of a Flux-lock type SFCL with Secondary Windings Connected in Serial and Parallel (2차 권선을 직.병렬연결한 자속구속형 전류제한기의 퀜치특성)

  • Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Oh, Geum-Kon;Han, Tea-Hee;Lim, Sung-Hun;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.432-434
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) according to the number of the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of the transformer with a primary winding and two secondary windings connected in parallel, and the superconducting element was connected with secondary winding in series, respectively. The applied voltage at that tin was 200V. when two superconducting elements of the secondary winding was connected in parallel, the peak lie current increased up to 99A, while that flowing in a superconducting element in conventional flux-lock type SFCL showed 50A under the same conditions, the impedance of secondary winding under the same situation showed the opposite behavior. This enabled the parallel structure to be easy to increase the capacity of power system, in the meantime, The quench between two superconducting elements in the SFCL with two secondary windings connected in parallel was achieved simultaneously. While the quench-starting point was slightly different in the SFCL with two superconducting elements connected in series. We found that the parallel connection between the secondary windings increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF

Current Limiting Characteristics due to Application Location of a Superconducting Fault Current Limiter in a Simulated Power Distribution System (모의배전계통에 초전도한류기의 도입위치에 따른 전류제한 특성)

  • You, Il-Kyoung;Kim, Jin-Seok;Kim, Myoung-Hoo;Kim, Jae-Chul;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.90-95
    • /
    • 2009
  • The application of a large power transformer into a power distribution system was inevitable due to the increase of power demand and distributed generation. However, the decrease of the power transformer‘s impedance causes the short-circuit current of the power distribution system to increase and thus, the higher short-circuit current exceeds the cut-off ratings of the protective devices such as a circuit breaker. To solve these problems, several countermeasures have been proposed to protect the power system effectively from the higher fault current and the superconducting fault current limiter (SFCL) has been expected to be the promising countermeasure. However, the current limiting effect of SFCL including its bus voltage drop compensation depends on SFCL's application location in a distributed power system. In this paper, the current limiting and the bus-voltage drop compensating characteristics of the SFCL applied into a power distribution system were studied. In addition, the quench and the recovery characteristics of the SFCLs in each location of the power distribution system were compared each other.

The design and Fabrication of Bandpass Filter Using Step Impedance Resonators of Coaxial Type (동축 형태의 스텝 임피던스 공진기를 이용한 필터 설계 및 제작)

  • Lee, Jung-Nam
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1272-1278
    • /
    • 2009
  • The present paper is purposeful that I compare the materialization method of the filter of UIR and SIR, then make two filters of different methods, so both are useful. The structure of the method of UIR is simple, so it is used a commercial point of view that the client gets the characteristics what he wants. However, the needs of companies when compared to the same standards, a little more cheaply in price, a little smaller in size, better performance characteristics are expected. In this regard, the method of SIR is smaller than UIR in size, but it shows the similar characteristics of UIR, so it is expected that holds a dominant position in competitive power. In this paper, based on these conditions, I compared the methods of SIR and UIR after the design and production. The standards are Insertion Loss is less than 0.8dB, Return Loss is above 20.0dB, and the Ripple is within 0.3dB. The center frequency is settled 881.5MHzband that TX Band is used by CDMA(SKT). I compared in the same conditions in Bandwidth 25.0MHz.

Effects of Blasting and Acidic Treatment on the Corrosion Characteristics of Dental Implant Fabricated with Cp-Ti and Ti-6Al-4V Alloy (Cp-Ti와 Ti-6Al-4V 합금으로 제조된 치과용 임플란트의 부식특성에 관한 블라스팅과 산세처리의 영향)

  • Moon, Young-Pil;Choe, Han-Cheol;Park, Su-Jung;Kim, Won-Gi;Ko, Yeong-Mu
    • Journal of Surface Science and Engineering
    • /
    • v.39 no.4
    • /
    • pp.190-197
    • /
    • 2006
  • The effects of blasting and acidic treatment on the corrosion characteristics of dental implant fabricated with Cp-Ti and Ti-6Al-4V alloy have been researched by using electrochemical methods. The fabricated implants were cleaned and sandblasted by $Al_2O_3$ powder and then acidic treatment was carried out in nitric acid solution. The surface morphology were observed using scanning electron microscope. The corrosion behaviors were investigated using potentiosat and EIS in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The potentio-dynamic test in 0.9% NaCl indicated that the corrosion potential of blasting and acidic treated implant was lower than that of non treated implant, but current density was higher than that of non treated implant. From the cyclic potentiodynamic test results of Ti implant, the passivation current density of blasting and acidic treated implant slightly higher than that of non treated implant. From A.C. impedance test results in 0.9% NaCl solution, polarization resistance($R_p$) value of blasting and acidic treated implant was lower than that of non treated implant. In case of blasting and acidic treated implant surface, the pits were observed in valley and crest of implant surface.

Psychological, Physical and Genetic Traits of Sasang Typology (사상인(四象人)의 생리적 특성 연구)

  • Chae, Han;Hong, Moo-Chang;Bae, Hyun-Su;Shin, Min-Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.304-314
    • /
    • 2005
  • The major concept of Sasang typology is that the disease susceptibility and drug response as well as physiological characteristics are presumed to be different depending on their Sasang types. Although characterizing fundamental basis of their traits are crucial in this research field, only pathological susceptibility and physical appearances were thoroughly studied. We evaluated their physiological characteristics by tapping psychological, physical and genetic traits of each Sasang types. After determining the Sasang type of one hundred three college students based on the Questionnaire for the Sasang Constitution Classification, the psychological, physical and genetic traits of each type were analyzed with the Myers-Briggs Type Indicator (MBTI), Bioelectrical Impedance Analysis and genetic polymorphism test, respectively. Each of the Sasang types showed significantly different profiles (Generalized estimation equation, coef=11.88, z=2.13, p=0.033), and could be distinctively classified based on their MBTI scores (discriminant analysis Wilks Lambda=0.611, df=8, chi-square=36.7, p<0.001). Subjects with the So-Eum type (Introversion and Judging) and the So-Yang type (Extroversion and Perceiving) showed contrasting psychological features, however they had similar anthropometric characteristics. Subjects with the Tae-Eum type showed bigger Body Mass Index ($R^2$=0.22, df=4, 74, F=5.07, p=0.001) and body shape compared to others. Although there were no significant differences in G-protein beta-3 subunit polymorphism, angiotensin-converting enzyme polymorphism and Methylenetetrahydrofolate reductase polymprhisms among groups with Sasang types, it was shown that the dopamine system could be one for genetic marker for Sasang typology. These results demonstrated distinctive and essential traits of Sasang typology using reproducible psychometric, anthropometric and genetic evaluations. We also found that the Sasang typology was a bio-psychological typology which could show trait-specific guideline for individualized medicine.

A small Inverted-F Antenna with adjustable characteristics using lumped elements (집중소자를 이용하여 특성 조절이 가능한 소형 역-F 안테나)

  • Yoo, Jin-Ha;Do, Sang-In;Lee, Young-Soon
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.646-651
    • /
    • 2013
  • In this paper, a small inverted-F antenna with adjustable characteristics is proposed with use of lumped elements, capacitor and resistor. Capacitor is inserted between end of the antenna and ground for size reduction and tuning of resonant frequency. On the other hand, $0{\Omega}$ resistor is replaced as the short line connected to ground. The movement of short point due to use of $0{\Omega}$ resistor results in providing variation of input impedance. Therefore optimum characteristics can be obtained only by proper choice of capacitor and short point without redesign of it's geometry. In order to check the validity, the proposed antenna is designed and fabricated for 2.4 GHz frequency band, and then is applied to a product of Zigbee wireless remote controller. As a result, the size of applied antenna is $8.5{\times}4.5mm^2$ and it is observed that the measured bandwidth and antenna gain are 150 MHz and 2 dBi respectively without redesign of the antenna.

A Study on Patch Antenna for C-ITS with Rectangle Slot (직사각형 슬롯을 갖는 C-ITS용 패치 안테나에 대한 연구)

  • Sang-Won Kang;Tae-Soon Chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.1
    • /
    • pp.103-107
    • /
    • 2024
  • This paper is a study on a triangle patch antenna using a rectangle slot and strip conductor. The length and spacing of the slot were adjusted to confirm the characteristics of the triangle patch antenna with rectangle slot, and the area and shape of the radiation patch were changed to triangle, rectangle, and hexagon for impedance matching. The HFSS simulator was used to check the antenna parameter characteristics, and the antenna size was 26 mm ×26 mm. In this proposed antenna, the simulation frequency range with VSWR of 2 or less was 5.27 to 6.24 GHz. The bandwidth was 970 MHz. The frequency range of the fabricated antenna was 5.24 to 6.38 GHz, and the bandwidth 1140 MHz. The maximum radiation gain is 5.01 dBi. It was confirmed that all radiation patterns had directional characteristics.

Seismic Data Processing and Inversion for Characterization of CO2 Storage Prospect in Ulleung Basin, East Sea (동해 울릉분지 CO2 저장소 특성 분석을 위한 탄성파 자료처리 및 역산)

  • Lee, Ho Yong;Kim, Min Jun;Park, Myong-Ho
    • Economic and Environmental Geology
    • /
    • v.48 no.1
    • /
    • pp.25-39
    • /
    • 2015
  • $CO_2$ geological storage plays an important role in reduction of greenhouse gas emissions, but there is a lack of research for CCS demonstration. To achieve the goal of CCS, storing $CO_2$ safely and permanently in underground geological formations, it is essential to understand the characteristics of them, such as total storage capacity, stability, etc. and establish an injection strategy. We perform the impedance inversion for the seismic data acquired from the Ulleung Basin in 2012. To review the possibility of $CO_2$ storage, we also construct porosity models and extract attributes of the prospects from the seismic data. To improve the quality of seismic data, amplitude preserved processing methods, SWD(Shallow Water Demultiple), SRME(Surface Related Multiple Elimination) and Radon Demultiple, are applied. Three well log data are also analysed, and the log correlations of each well are 0.648, 0.574 and 0.342, respectively. All wells are used in building the low-frequency model to generate more robust initial model. Simultaneous pre-stack inversion is performed on all of the 2D profiles and inverted P-impedance, S-impedance and Vp/Vs ratio are generated from the inversion process. With the porosity profiles generated from the seismic inversion process, the porous and non-porous zones can be identified for the purpose of the $CO_2$ sequestration initiative. More detailed characterization of the geological storage and the simulation of $CO_2$ migration might be an essential for the CCS demonstration.