• Title/Summary/Keyword: impedance characteristics

Search Result 1,741, Processing Time 0.03 seconds

A Study on the Characteristics of Microstrip Patch Antenna with Slot/T-Slot Capacitive Coupling (슬롯/T-슬롯 커패시티브 커플링을 이용한 마이크로스트립 패치 안테나의 특성 연구)

  • Seo, Ki-Won;Roh, Hyoung-Hwan;Seong, Yeong-Rak;Oh, Ha-Ryoung;Park, Jun-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1282-1288
    • /
    • 2010
  • This paper proposes a novel microstrip patch antenna to make impedance matching possible by using slot/T-slot capacitive coupling between the patch and 50 $\Omega$ feed line on a ground plane. The single band/linear polarization patch antenna shows linear polarization at 2.4 GHz band. Under -10 dB return loss, the single band/linear polarization patch antenna obtains 50 MHz bandwidth at 2.37 GHz~2.42 GHz. The dual band/dual polarization microstrip patch antenna shows circular polarization at 2.4 GHz band and linear polarization at 3.1 GHz band. Under -10 dB return loss, The dual band/dual polarization microstrip patch antenna obtains 340 MHz bandwidth at 2.23~2.57 GHz and 375 MHz bandwidth at 2.95~3.325 GHz.

Design of Wideband Square Loop Antenna for DTV Applications (DTV용 광대역 사각형 루프 안테나 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.73-74
    • /
    • 2016
  • In this paper, a design method for a wideband square loop antenna for Digital TV applications is studied. The proposed loop antenna is a square loop antenna combined with circular sectors to connect with central feed points. The input reflection coefficient and gain characteristics of the proposed antenna are analyzed to match with the 75 ohm input impedance for DTV applications. The optimized antenna is designed on FR4 substrate, and it operates in the frequency band of 470-1,300 MHz for a VSWR < 2, which assures the operation in the DTV band(470-806 MHz).

  • PDF

Performance Analysis and Degradation Characteristics of NCM LIB for ESS (ESS용 NCM계 LIB의 설계인자별 성능분석 및 열화특성 연구)

  • Kwon, S.J;Park, E.Y;Lim, J.H;Choi, J.H;Kim, J.H
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.219-221
    • /
    • 2018
  • ESS용 NCM계 $LIB(Li[Ni_xCo_yMn_z]O_2)$의 양극 전이금속 설계인자 조성비(x:y:z)를 5:2:3, 6:2:2로 달리하여 제작한 전지를 사용하여 C-rate별 방전시험을 통한 기본성능평가를 진행하였고, 가속열화 시험을 통한 수명특성을 분석하였다. EIS(Electrochemical Impedance Spectroscopy) 실험을 통하여 전지의 임피던스를 확인하였고, 열화되지 않은(Fresh) 전지와 열화된(Aging) 전지의 SOC(State-of-Charge)별 임피던스 특성을 비교 분석하였다.

  • PDF

Measurements of multimode characteristics including surface wave mode in a dielectrically loaded rectangular cavity (직육면체 캐비티의 다중 모드 특성및 표면파 모드 특성 측정)

  • 김채영;김윤명;라정웅
    • 전기의세계
    • /
    • v.28 no.4
    • /
    • pp.47-52
    • /
    • 1979
  • Total number of resonant modes in a microwave oven cavity may be maximized for a given frequency bandwidth to obtain more uniform power distribution by choosing proper size of the cavity. The total number of modes is calculated for a dielectrically loaded rectangular cavity and its size is suggested here for which the change in the number of modes is less sensitive to the change of dielectric layer thickness and its total number of modes is maximized in a given range of cavity sizes. A prove coupled rectangular cavity is constructed and the total existing modes are measured to see the change of modes depending on the dielectric layer thickness and the cavity size. Surface wave mode existing in the dielectric layer is confirmed by measuring Q and the input impedance of the cavity for this mode, which closely compares with the calculation.

  • PDF

A Study on the Dielectric and Strain Properties of PNST Ceramics (PNST세라믹스의 유전 및 변형특성에 관한 연구)

  • 김진수;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.331-334
    • /
    • 1998
  • The solid solutions of the Pb(Sc$\_$0.5/Nb$\_$0.5/)$\_$0.57/Ti$\_$0.43/O$_3$ system were prepared. In the PSNT system, it had been known that two-phase region between the rhombohedral and tetragonal phases was observed between 0.425 of PT at room temperature. In this paper, Fe$_2$O$_3$-doped 0.57PSN-0.43PT composition was prepared by conventional method. The dielectric and strain properties were examined using an computerized measuring apparatus, and the resonance characteristics were measured using an impedance gain phase analyzer. We got the data of dielectric constant, dielectric loss, piezoelectric coefficient, piezoelectric voltage coefficient, frequency constant strain constant mechanical quality factor and electromechanical coupling factor.

  • PDF

The Impulse Output Characteristics using Cascading Method of Compact Transformer (소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성)

  • Joung, Jong-Han;Kim, Whi-Young;Hong, Jung-Hwan;Park, Koo-Ryul;Kim, Hee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1865-1867
    • /
    • 2000
  • The pulse power system has been widely used to many applications. such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, ozon generator. etc. A pulse energy efficiency for load depend on the rising time, peak value, pulse duration, impedance matching. etc. The pulse generator generally required for short pulse duration, high peak value was forced to consider its size and economy. In this study, developing a compact pulse generator that applied for Cascading method to be made of two pulse transformer, we compared cascading voltage with no cascading one by applying the pulse energy to load.

  • PDF

Ground Impedance Characteristics for Grounding System on Power Substation (정상시 접지계통의 접지 임피던스 특성)

  • Kim, Jae-Yee;Ko, Young-Hyuk;Ko, Young-Gwon;Kim, Jeong-Bu;Jeong, Kil-Jo;Ki, Hyun-Chan;Choi, Jong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2207-2209
    • /
    • 2000
  • 본 논문에서는 접지 모델을 활용하여 접지계의 임펄스 임피던스를 계산하고, 선로 임피던스에 연결된 접지 임피던스의 반사계수를 계산하여 대지로 유입되는 분류율을 평가하였다. 따라서 접지 저항을 낮추는 경우 평상시 전위 상승효과를 줄일 수는 있지만 위험전압의 인가시에는 인축의 안전과 기기의 절연 측면에서 악조건의 상황이 될 수 있다. 또한 접지 모델에서 용량의 변화와 접지 저항의 변화에 따른 반사계수의 변화를 확인하였고, 상용 주파수 근처에서는 저항 성분만 존재하고 리액턴스 효과는 없음을 확인하였다.

  • PDF

The Surface Analysis of the Merocyanine Dye LB film using Optical system (광학시스템을 이용한 메로시아닌 색소 LB막의 표면 모폴로지 해석)

  • Kang, Ki-Ho;Shin, Hoon-Kyu;Chang, Jung-Soo;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1714-1716
    • /
    • 2000
  • We fabricated the optical system of merocyanine dye using Langmuir-Blodgett(LB) technique because quite uniform orientation could be obtained, which is one of the most important factors to affect to its optical characteristics. The resonance frequency and other electrical parameters at the parallel resonance state were measured using the impedance analyser(HP 4294 A). Also the morphological changes of dye molecules after UV irradiation were observed using AFM. The parallel resonance frequency and resistance by electrical equivalent circuit were decreased with the UV irradiation and these aspects are different from general mass adsorption process. Therefore the structural changes of dye molecules are being considered, that is, the aggregated molecules become dissociated. It indicates that the shifts of the resonance frequency and the others occurred without mass absorption.

  • PDF

Novel Design and Operational Characteristics of Inductive High-Tc Superconducting Fault Current Limiter to Protection the Power System (전력시스템 보호를 위한 공극을 이용한 유도형 고온초전도체 한류기의 디자인과 동작특성)

  • Jang, Mi-Hye;Lee, Chan-Joo;Joo, Min-Seok;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.281-283
    • /
    • 1999
  • A novel prototype of an inductive superconducting fault current limiter with an iron core and an air sap was fabricated and tested. If its impedance is not high enough to limit the fault current, then destructive damage occurs in the power system. We attained a magnetic saturation under the higher current by introducing an air gap in the three-legged magnetic core. The fault current was successfully limited to two times as much as the nominal current without high fault current within 1/4 cycles at a 60 Hz source having an effective voltage of 70V.

  • PDF

The measurement & Analysis of Voltage, Current and Load Unbalance Factor at Three Phase Four Wire Load System (3상 4선식 부하설비의 전압, 전류 및 부하 불평형율 측정 분석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju;Lee, Jong-Han;Jeong, Jong-Ho;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.28-30
    • /
    • 2005
  • This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. This system is composed of three one-phase transformer with each other capacity. Current unbalance factor is measured by the power quality measurement apparatus and compared by the load unbalance factor. Each phase has an impedance each other by the unbalanced load operation pattern and give rise to voltage unbalance.

  • PDF