• Title/Summary/Keyword: impedance analyzer

Search Result 230, Processing Time 0.023 seconds

Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis (신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현)

  • Kim, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5403-5408
    • /
    • 2012
  • In this paper, we introduce the multiple frequency bio-electrical impedance analysis method for body composition analysis. And then we implement the multiple frequency bio-electrical impedance analysis system. Overall system consists of: multiple frequency alternating current signal generator contained alternating current signal, phase signal detector, voltage signal detector, micro controller, in-out device(key-pad LCD), conductivity electrodes, system power. We explain the architecture of the system and required theory to implement the system. In order to investigate the clinical significance of the body composition data, compare to the data measured by the expert body composition analyzer which provide high reproduction and precision. Finally, experimental results which are the correlation between the measured data show the very high reproduction performance of the body composition analysis in the proposed system.

Fabrication and Characterization of Pyrolyzed Carbon for Use as an Electrode Material in Electrochemical Biosensor (전기화학 바이오센서의 전극물질로 응용을 위한 열분해 탄소의 제작 및 특성 연구)

  • Lee, Jung-A.;Hwang, Seong-Pil;Kwak, Ju-Hyoun;Park, Se-Il;Lee, Seung-Seob;Lee, Kwang-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.10
    • /
    • pp.986-992
    • /
    • 2007
  • This paper presents the fabrication and characterization of carbon films pyrolyzed with various photoresists for bioMEMS applications. To verify the usefulness of pyrolyzed carbon films as an electrode material in an electrochemical biosensor developed by the authors, interactions between avidin and biotin on the pyrolyzed carbon film were studied via electrochemical impedance spectroscopy based on electrostatic interactions between avidin and negatively-charged ferricyanide. The pyrolyzed carbon films were characterized using a surface profiler, a precision semiconductor parameter analyzer, a nanoindentor, scanning electron microscopy, and atomic force microscopy. Amine conjugated biotin was immobilized on the electrode using EDC/NHS as crosslinkers after $O_2$ plasma treatment to enhance functional groups on the carbon electrode pyrolyzed at $1000^{\circ}C$ with AZ9260. The detection of avidin binding with different concentrations in a range of 0.75 nM to $7.5\;{\mu}M$ to the pyrolyzed carbon electrode modified with biotin was carried out by measuring the electrochemical impedance change. The results show that avidin binds to the biotin on the electrode not by non-specific interaction but by specific interaction, and that EIS successfully detects this binding event. Pyrolyzed carbon films are a promising material for miniaturization, integration, and low-cost fabrication in electrochemical biosensors.

Quantitative Assessment of the Fastening Condition and the Crack Size with Using Piezoceramic(PZT) Sensors (압전소자를 이용한 볼트토크 및 크랙의 정량적평가에 관한 연구)

  • Hong, Dong-Pyo;Hong, Yong;Wang, Gao-Ping;Han, Byeong-Hee;Kim, Young-Moon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.603-606
    • /
    • 2006
  • We present a study on the development of a practical and quantitative technique for the assessment of the structural health condition with using piezoceramic(PZT) sensors. The electro-impedance-based technique with the PZT patches is very sensitive for evaluation of the incipient and small damage in a high frequency range, and however the commonly traditional modal analysis method is effective only for considerably larger damages in low frequency range. The paper presents the technique in detecting and characterizing real-time damage on the specimen that is an aluminum plate fastened with bolts and nuts by different torques and as well a plate with a crack. By using the special arrangement of the PZT sensors, the required longitudinal wave is generated through the specimen. A large number of experiments are conducted and the different conditions of the specimens, i.e. the location and extent of loosening bolts, and the plate with a crack are simulated. respectively. Since fixing and loosening the loosened bolt is controlled by a torque wrench, we can control exactly the experiment of the different torques. Compared with the simulated healthy condition, we can find whether or not there is a damage in the specimen with using an impedance analyzer with the PZT sensors. Several indices are discussed and used for assessing the different simulated damages. As for the location of bolt loosening, the RMSD is found to be the most appropriate index for numerical assessment and as well the RMSD shows strongly linear relationship for assessing the extent of the bolt loosening, and the frequency peak shift ${\Delta}F$ is used to assess the cracked plate. The possibility of repeatability of the pristine condition signatures is also presented and the appropriate frequency range and interval are uniquely selected through large numbers of experiments.

  • PDF

Characteristics of Coaxial Typed Magnetic Sensor Using Amorphous Wire (자성와이어를 이용한 동축케이블형 자계센서의 특성)

  • Kim, Y.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.55-59
    • /
    • 2007
  • Co-based amorphous magnetic wire with a diameter of $125{\mu}m$ and a length of 40 mm was used as an inner conductor of a coaxial cable to construct a magnetic sensor. Sensor characteristics was measured up to 3 GHz with applied up to 60 Oe by using network analyzer. Frequency dependence of impedance for this sensor was very close to the impedance resonant pattern of transmission line and 250 MHz was obtained as a 1/4 wavelength without external magnetic field. Large impedance change was measured in the magnetic field range between 0 Oe and 1 Oe, which was influenced by permeability change of magnetic amorphous wire. Because ${\Delta}Z/{\Delta}H$ value of $300{\Omega}/Oe$ was obtained at 0.1 Oe, this coaxial cable with amorphous wire can be useful as a magnetic sensor.

Eddy Current Testing using Encircling Differential Probe for Research Reactor Fuel Rods (외삽 차동형 탐촉자를 사용한 연구로용 핵연료봉의 와전류탐상)

  • Lee, Yoon-Sang;Kim, Chang-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.561-564
    • /
    • 2001
  • The cladding area of HANARO Research Reactor fuel rods should be checked not to have any defects larger than the size required at QA documents by using eddy torrent testing method doting fabrication process. To apply eddy current testing inspection to the fuel rods, encircling differential probes and standard specimen were designed and fabricated. The impedance of the fabricated probes was measured with impedance analyzer in order to cheek that the probe has a suitable impedance for the inspection frequency, and with this probe and MIZ-40A eddy current equipment, the detectability of this probes was investigated. The developed probes could detect artificial notch with 2mm length 10% depth of cladding thickness in cladding area. In addition, the probe was successfully applied to detect the defects in cladding area doting fabrication of the research reactor rods.

  • PDF

Fabrication and NOx Gas Sensing Properties of LaMeO3 (Me = Cr, Co) by Polymeric Precursor Method (Polymeric Precursor법에 의한 LaMeO3 (Me = Cr, Co)의 제조 및 NOx 가스 검지 특성)

  • Lee, Young-Sung;Shimizu, Y.;Song, Jeong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.21 no.8
    • /
    • pp.468-475
    • /
    • 2011
  • [ $LaMeO_3$ ](Me = Cr, Co) powders were prepared using the polymeric precursor method. The effects of the chelating agent and the polymeric additive on the synthesis of the $LaMeO_3$ perovskite were studied. The samples were synthesized using ethylene glycol (EG) as the solvent, acetyl acetone (AcAc) as the chelating agent, and polyvinylpyrrolidone (PVP) as the polymer additive. The thermal decomposition behavior of the precursor powder was characterized using a thermal analysis (TG-DTA). The crystallization and particle sizes of the $LaMeO_3$ powders were investigated via powder X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), and particle size analyzer, respectively. The as-prepared precursor primarily has $LaMeO_3$ at the optimum condition, i.e. for a molar ratio of both metal-source (a : a) : EG (80a : 80a) : AcAc (8a) inclusive of 1 wt% PVP. When the as-prepared precursor was calcined at $700^{\circ}C$, only a single phase was observed to correspond with the orthorhombic structure of $LaCrO_3$ and the rhombohedral structure of $LaCoO_3$. A solid-electrolyte impedance-metric sensor device composed of $Li_{1.5}Al_{0.5}Ti_{1.5}(PO_4)_3$ as a transducer and $LaMeO_3$ as a receptor has been systematically investigated for the detection of NOx in the range of 20 to 250 ppm at $400^{\circ}C$. The sensor responses were able to divide the component between resistance and capacitance. The impedance-metric sensor for the NO showed higher sensitivity compared with $NO_2$. The responses of the impedance-metric sensor device showed dependence on each value of the NOx concentration.

A simple Q measurement method of a lossy coupled cavity resonator (손실결합 공동공진기의 간편한 Q 측정 방법)

  • Han, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.1015-1020
    • /
    • 2018
  • The cavity resonator is one of the widely used components in the microwave applications. The unloaded Q, the resonant frequency, and the coupling factor are basic parameters of a cavity. A simple unloaded Q factor measurement procedure of a cavity is proposed in a lossy coupling. The equivalent circuit of a cavity with coupling loss at near the resonant frequency is presented. The coupling loss resistance was found by the measurement of a cavity impedance. The cavity impedance compensated coupling loss was redrawn on the Smith Chart. The loaded Q and coupling factor were obtained based on the compensated impedance locus and then the unloaded Q factor was calculated. To verify the proposed procedure, the cavity with lossless coupling was measured. The two measurement results in the lossy and lossless coupling agree well. The results confirm the proposed procedure is valid.

The defect detection circuit of an electronic circuit through impedance change detection that induces a change in S-parameter (S-parameter의 변화를 유도하는 임피던스 변화 감지를 통한 전자회로의 결함검출회로)

  • Seo, Donghwan;Kang, Tae-yeob;Yoo, Jinho;Min, Joonki;Park, Changkun
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.689-696
    • /
    • 2021
  • In this paper, in order to apply Prognostics and Health Management(PHM) to an electronic system or circuit, a circuit capable of detecting and predicting defect characteristics inside the system or circuit is implemented, and the results are described. In the previous study, we demonstrated that the frequency of the amplitude of S-parameter changed as the circuit defect progressed. These characteristics were measured by network analyser. but in this study, even if the same defect detection method is used, a circuit is proposed to check the progress of the defect, the remaining time, and the occurrence of the defect without large measurement devices. The circuit is designed to detect the change in impedance that generates changes of S-parameter, and it is verified through simulation using the measurement results of Bond-wires.

Estimation of Antenna Correlation Coefficient of N-Port Lossy MIMO Array

  • Saputro, Susilo Ady;Nandiwardhana, Satya;Chung, Jae-Young
    • ETRI Journal
    • /
    • v.40 no.3
    • /
    • pp.303-308
    • /
    • 2018
  • This paper proposes a simple yet accurate method for estimating the antenna correlation coefficient (ACC) of a high-order multiple-input multiple-output (MIMO) antenna. The conventional method employed to obtain the ACC from three-dimensional radiation patterns is costly and difficult to measure. An alternate method is to use the S-parameters, which can be easily measured using a network analyzer. However, this method assumes that the antennas are highly efficient, and it is therefore not suitable for lossy MIMO antenna arrays. To overcome this limitation, we define and utilize the non-coupled radiation efficiency in the S-parameter-based ACC formula. The accuracy of the proposed method is verified by the simulation results of a 4-port highly coupled lossy MIMO array. Further, the proposed method can be applied to N-port arrays by expanding the calculation matrix.

A Study on the Environmental Properties of Polyimide/Silica Composites Prepared by Sol-Gel Method (졸-겔법으로 합성된 폴리이미드/실리카 복합체의 환경적 물성에 관한 연구)

  • 박성수;홍성수;이성환;김성완;박재현;김지경;박희찬
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.481-485
    • /
    • 2003
  • Two types of polyimide/silica composite films were prepared using sol-gel method through hydrolysis and polycondensation of tetraethoxysilane (TEOS) with the polyamic acid (PAA) and end-capped PAA solution. Samples were characterized by the means of differential thermogravimetry, X-ray diffractometry, scanning electron microscopy, universal test, impedance analyzer, chemical resistance test, etc. All of the PAA/silanol solutions heat-treated at 300$^{\circ}C$ for 6h were transformed to polyimide/silica composites. It has been demonstrated that the properties of polyimide/silica composites were affected by the amount of silica addition and the bend type existed between polyimide and silica.