• Title/Summary/Keyword: impact loads

Search Result 723, Processing Time 0.025 seconds

Finite Element Analysis of Pipe Whip Restraint Behavior Under Jet Thrust Forces (유체 분사 추진력을 받는 배관 휩 구속장치 거동에 관한 유한요소해석)

  • Sugoong Koh;Lee, Young-Shin
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.353-360
    • /
    • 1993
  • Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to design the pipe whip restraints properly and/or to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various types of finite elements in ANSYS[1], the general purpose finite element computer program, was used to simulate the postulated pipe whips to obtain impact loads and the calculated results were compared with the specific experimental results from the sample pipe whip test for the U-shaped pipe whip restraints. Some calculational models, having the gap element or the spring element between the pipe whip restraint and the pipe line, give reasonably good transient responses of the restraint forces compared with the experimental results, and could be useful in evaluating the acceptability of the pipe whip restraint design.

  • PDF

A Study on the Optimum Design of a Facade with Shading-type BIPV in Office Building (차양형 BIPV가 적용된 사무소 건물의 외피 최적 설계에 관한 연구)

  • Park, Se-Hyeon;Kang, Jun-Gu;Bang, Ah-Young;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Zero energy building is a self sufficient building that minimizes energy consumption through passive elements such as insulation, high performance window system and installing of high efficiency HVAC system and uses renewable energy sources. The Korea Government has been strengthening the building energy efficiency standard and code for zero energy building. The building energy performance is determined by the performance of building envelope. Therefore it is important to optimize facade design such as insulation, window properties and shading, that affect the heating and cooling loads. In particular, shading devices are necessary to reduce the cooling load in summer season. Meanwhile, BIPV shading system functions as a renewable energy technology applied in solar control facade system to reduce cooling load and produce electricity simultaneously. Therefore, when installing the BIPV shading system, the length of shadings and angle that affect the electricity production must be considered. This study focused on the facade design applied with BIPV shading system for maximizing energy saving of the selected standard building. The impact of changing insulation on roof and walls, window properties and length of BIPV shading device on energy performance of the building were investigated. In conclusion, energy consumption and electricity production were analyzed based on building energy simulations using energyplus 8.1 building simulation program and jEPlus+EA optimization tool.

Progressive Collapse Analysis of Reinforced Concrete Core Structure Subjected to Internal Blast Loading (내부 폭발하중을 받는 철근콘크리트 코어의 연쇄붕괴 해석)

  • Kim, Han-Soo;Ahn, Jae-Gyun;Ahn, Hyo-Seong
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.715-722
    • /
    • 2014
  • In this paper, internal blast effect of reinforced concrete core structure were investigated using Ansys Autodyn, which is a specialized hydrocode for the analysis of explosion and impact. It is expected that internal blast case can give additional damage to the structure because it causes rebound of blast loads. Therefore, in this paper, the hazard of internal blast effect is demonstrated using UFC 3-340-02 criteria. In addition, analysis result of Autodyn, experimental result regarding rebound of blast load, and example of UFC 340-02 are compared to verify that Autodyn can analyze internal blast effect properly. Furthermore, progressive collapse mechanism of core structure which is one of the most important parts in high rise buildings is also analyzed using Autodyn. When internal blasts are loaded to core structure, the core structure is mostly damaged on its corner and front part of core wall from explosives. Therefore, if the damaged parts of core wall are demolished, progressive collapse of the core structure can be initiated.

Mechanistic-Empirical Guideline for Routine Overweight Truck Traffic Routes (과하중 트럭 운행 도로에 대한 역학적-경험적 지침)

  • Oh, Jeongho
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • The main objective of this research is to develop the Mechanistic-Empirical (M-E) guidelines for evaluating the capacity of existing highways to sustain route overweight truck traffic over a specified performance period due to a growing concern on the impact of increasing overweight truck loads on highways. In this study, a two-stage framework was developed for this purpose. Level I procedure involves the use of pavement evaluation charts to identify the best possible route from among the alternatives considered and to determine what additional tests and analyses are needed as a screening tool. Level II involves the application of the Overweight Truck Route Analysis (OTRA) program to evaluate the structural adequacy of an existing route to carry routine overweight truck traffic over the specified performance period along with estimating asphalt concrete overlay thickness, if necessary.

Analysis of the Characteristics of NPS Runoff and Application of L-THIA model at Upper Daecheong Reservoir (대청호 상류 유역의 비점오염원 유출특성 분석 및 L-THIA 모형 적용성 평가)

  • Shin, Min-Hwan;Lee, Jae-An;Cheon, Se-Uk;Lee, Yeoul-Jae;Lim, Kyoung-Jae;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.1
    • /
    • pp.1-11
    • /
    • 2010
  • Generation and transportation of runoff and pollutant loads within watershed generated eutrophication at Daecheong reservoir. To improve water quality at Daecheong reservoir, the best management practices should be developed and applied at upper watersheds for water quality improvement at downstream areas. In this study, two small watersheds of upper Daecheong reservoir were selected. The Long-Term Hydrologic Impact Assessment (L-THIA) model has been widely used for the estimation of the direct runoff worldwide. To apply the L-THIA ArcView GIS model was evaluated for direct runoff and water quality estimation at small watershed. And the Web-based Hydrograph Analysis Tool (WHAT) was used for direct runoff separating from total flow. As a result, the $R^2$ (Coefficient of determination) value and Nash-Sutcliffe coefficient value for direct runoff comparison at An-nae watershed were 0.81 and 0.71, respectively. And the $R^2$ value and Nash-Sutcliffe coefficient value at Wol-oe were 0.95 and 0.93. The $R^2$ value of BOD, TOC, T-N and T-P at An-nae watershed were BOD 0.94, TOC 0.81, T-N 0.94 and T-P 0.89. And the $R^2$ value of BOD, TOC, T-N and T-P at Wol-oe watershed were BOD 0.80, TOC 0.93, T-N 0.86 and T-P 0.65. The result that estimated pollutant loadings using the L-THIA ArcView GIS model reflected well the measured pollutant loadings except for T-P in Wol-oe watershed. With L-THIA ArcView GIS model, the direct runoff and non-point pollutant (NPS) loadings in the watershed could be analyzed through simple input data such as daily rainfall, land uses, and hydrologic soil group.

Parametric Study on Long-Term Deflections of Flat Plates Considering Effects of Construction Loads and Cracking (시공하중 및 균열 효과를 고려한 플랫 플레이트의 장기 처짐에 대한 변수 연구)

  • Choi, Seung Min;Eom, Tae Sung;Kim, Jea Yo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.44-54
    • /
    • 2012
  • The structural designs of RC flat plates that have no flexural stiffness by boundary beams may be governed not by strength conditions but by serviceabilities. Specially, since over-loading and tensile cracking in early-aged slabs significantly increase the immediate and long-term deflections of a flat plate system, a construction sequence and its impact on the slab deflections may be decisive factors in designs of flat plate systems. In this study, the procedure of calculating slab deflections with considering construction sequences, concrete cracking, and long-term effects is proposed. Using the proposed method, the parametric study for deflections of flat plates is performed. With various conditions for slab construction cycle, the number of shored floors, tensile or compressive reinforcement ratio, compressive strength of concrete, construction live load, and slab thickness, the immediate deflection during construction and long-term deflections after completion are analyzed. The calculated results are compared with the serviceability limits offered by the structural design code.

FIRES IN REAL SCENARIOS

  • Ghosh, B-K
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.439-449
    • /
    • 1997
  • Studies have been carried out to determine the effect of sprinklers on fires typical of a number of occupancies including simulated of office furniture, supermarkets, carpet displays, libraries, video stores and liquor stores. After surveys of actual fire loads, the experiments were conducted in a specially designed sprinklered fire-calorimeter with a collecting hood 6 m x6 m leading to a vertical duct 1 m in diameter. Details of the rig are given elsewhere [1]. Only well ventilated fires were studied. Rate of heat release and production of various toxic chemicals were monitored during the tests. Both sprinklered and unsprinklered fires were used. The results were used to establish the unsprinklered burning behaviour and the fire-control effects of sprinklers. Before sprinkler operation, the rate of fire growth could be modelled as 12_fires as given in NFPA 92B (1991 Edition) [2]. It was found that operation of sprirnklers controlled but did not extinguish the fires. This was expected as parts of the fire load were shielded from the spray. Also there were significant increases in the concentration of carbon monoxide when the sprinklers operated. Sprinklers had little effect on the concentrations of other toxic products measured. The results from the tests were extrapolated to large single storey buildings for the same occupancy classes and the results used to compare the required and the available escape times for different occupancies, particularly whether the use of sprinklers would improve the chances of escape from those premises. It was found that in most of the cases studied, adequate escape times will be available without any special measures. For very rapid fire growths, however, special measures, such as availability of trained staff may be needed. Standard response sprinklers will have little impact.

  • PDF

A Study on the Design Safety of Type III High-Pressure Hydrogen Storage Vessel (Type III 고압수소저장용기의 설계 안전성 연구)

  • Park, Woo Rim;Jeon, Sang Koo;Kim, Song Mi;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.7-14
    • /
    • 2019
  • The type III vessel, which is used to store high-pressure hydrogen gas, is made by wrapping the vessel's liner with carbon fiber composite materials for strength performance and lightening. The liner seals the internal gas and the composite resists the internal pressure. The properties of the fiber composite material depends on the angle and thickness of the fiber. Thus, engineers should consider these various design variables. However, it significantly increases the design cost due to the trial and error under designing based on experience or experiments. And, for aluminum liners, fatigue loads due to using and charging could give a huge impact on the performance of the structure. However, fatigue failure does not necessarily occur in the position under the highest load in use. Therefore, for hydrogen storage vessel, fatigue evaluation according to design patterns is essential because stress distribution varies depend on composite layer patterns. This study performed an optimization analysis and evaluated a high-pressure hydrogen storage vessel to minimize these trial and error and improve the reliability of the structure, while simultaneously conducting fatigue assessment of all patterns derived from the optimization analysis process. The results of this study are thought to be useful in the strength improvement and life design of composite reinforced high-pressure storage vessels.

Effect of Sirikit Dam Operation Improvement on water shortage situations due to the land use and climate changes from the Nan Basin

  • Koontanakulvong, Sucharit;Suthidhummajit, Chokchai
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.232-232
    • /
    • 2015
  • Land use and climate changes are the important factors to determine the runoff and sediment loads from the watershed. The changes also affected to runoff volume/pattern to the dam operation and may cause flood and drought situations in the downstream area. Sirikit Dam is one of the biggest dams in Thailand which cover about 25 % of the runoff into the Central Plain where the Bangkok Capital is located. The study aims to determine the effect of land use change to the runoff/sediment volume pattern and the rainfall-runoff-sediment relationship in the different land use type. Field measurements of the actual rainfall, runoff and sediment in the selected four sub-basins with different type of land use in the Upper Nan Basin were conducted and the runoff ratio coefficients and sediment yield were estimated for each sub-basin. The effect of the land use change (deforestation) towards runoff/sediment will be investigated. The study of the climate change impact on the runoff in the future scenarios was conducted to project the change of runoff volume/pattern into the Sirikit Dam. The improvement of the Sirikit Dam operation rule was conducted to reduce the weakness of the existing operation rules after Floods 2011. The newly proposed dam operation rule improvement will then be evaluated from the water shortage situations in the downstream of Sirikit Dam under various conditions of changes of both land use and climate when compared with the situations based on the existing reservoir operation rules.

  • PDF

A Convergence Study through Analysis of Strength and Durability on Automotive A-Pillar (자동차의 A필러에 대한 강도 및 내구성 해석을 통한 융합 연구)

  • Oh, Bum-Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.297-302
    • /
    • 2019
  • A-pillar is closely related to safety for the purpose of protecting the bodies of passengers by mitigating the impact that may be caused by the vehicle being overturned while driving. Therefore, the A-pillar should protect these parts from a variety of dynamic loads. This study result is thought to contribute for the strength and durability of A-pillar by designing two types of parts before making this product and analyzing the product which thickness is adjusted for the light weight of vehicle. If this study result is practically applied to the parts of A-pillar in a car, it is considered that the damage can be protected by the durability verification of design. By utilizing the data of analysis and design on the strength and durability of automotive A-pillar in this study, the esthetic sense can be given by being grafted onto the real automotive part.