• 제목/요약/키워드: immunochromatographic assay

검색결과 38건 처리시간 0.032초

Helicobacter pylori 감염진단에 있어 H. pylori Ag Stool 검사 (면역크로마토그라피법)의 임상적 유용성 (Clinical Usefulness of Helicobactor pylori Ag Stool Test (Immunochromatographic Assay) for Diagnosis of H. pylori Infection)

  • 서설
    • 대한임상검사과학회지
    • /
    • 제42권1호
    • /
    • pp.38-45
    • /
    • 2010
  • The aim of this study was to assess the Clinical Usefulness of Helicobacter pylori Stool Antigen (HpSA) immunochromatographic assay for the diagnosis of H. pylori infection. In this study, we had compared HpSA-immunochromatographic assay with CLO test and UBT test. From a total of 140 patients (M:F=88:52) with upper endoscopy, biopsy specimens were obtained for CLO test. Stool specimens was collected from all patients and tested using a HpSA-immunochromatic assay. H. pylori infection status was defined as infected if the results of both CLO test and UBT test were positive. CLO test and UBT test findings showed that 92 patients were H. pylori positive and 48 patients were H. pylori negative. According to this definition, the sensitivity, specificity, and positive or negative predictive value (PPV, NPV) of HpSA-immunochromatographic assay were 97.8%, 100%, 100%, and 96%, respectively. Cross reactivity test of HpSA-immunochromatographic assay were performed with 10 enteric bacteria strains in fecal habitat, and there were no false positive reaction. We evaluated the usefulness of HpSA assay for eradication therapy with 10 of 92 H. pylori positive patients, positive results of them at pre-eradication therapy were converted to negative at post-eradication. The HpSA-immunochromatographic assay is a highly sensitive and specific non-invasive diagnostic method for detection of H. pylori infection, a useful diagnostic method for H. pylori in post eradication stage.

  • PDF

Chemiluminescence immunochromatographic analysis for the quantitative determination of algal toxins

  • Pyo, Dongjin;Kim, Taehoon
    • ALGAE
    • /
    • 제28권3호
    • /
    • pp.289-296
    • /
    • 2013
  • For the quantitative detection of algal toxin, microcystin, a chemiluminescence immunochromatographic assay method was developed. The developed system consists of four parts, chemiluminescence assay strip (nitrocellulose membrane), horse radish peroxidase labeled microcystin monoclonal antibodies, chemiluminescence substrate (luminol and hydrogen peroxide), and luminometer. The performance of the chemiluminescence immunochromatographic assay system was compared with high performance liquid chromatography (HPLC) detection. The detection limit of chemiluminescence immunochromatographic assay system is several orders of magnitude lower than with HPLC. The chemiluminescence immunochromatography and HPLC results correlated very well with the correlation coefficient ($r^2$) of 0.979.

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제5권5호
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF

Immunochromatographic Strip Assay for Detection of Cronobacter sakazakii in Pure Culture

  • Song, Xinjie;Shukla, Shruti;Lee, Gibaek;Kim, Myunghee
    • Journal of Microbiology and Biotechnology
    • /
    • 제26권11호
    • /
    • pp.1855-1862
    • /
    • 2016
  • Cronobacter sakazakii (C. sakazakii) is a foodborne pathogen, posing a high risk of disease to infants and immunocompromised individuals. In order to develop a quick, easy, and sensitive assay for detecting C. sakazakii, a rabbit anti-C. sakazakii immunoglobulin G (IgG) was developed using sonicated cell protein from C. sakazakii. The developed anti-C. sakazakii (IgG) was of good quality and purity, as well as species-specific. The developed rabbit anti-C. sakazakii IgG was attached to the surface of a sulforhodamine B-encapsulated liposome to form an immunoliposome. A test strip was then prepared by coating goat anti-rabbit IgG onto the control line and rabbit anti-C. sakazakii IgG onto the test line, respectively, of a plastic-backed nitrocellulose membrane. A purple color signal both on the test line and the control line indicated the presence of C. sakazakii in the sample, whereas purple color only on the control line indicated the absence of C. sakazakii in the sample. This immunochromatographic strip assay could produce results in 15 min with a limit of detection of $10^7CFU/ml$ in C. sakazakii culture. The immunochromatographic strip assay also showed very good specificity without cross-reactivity with other tested Cronobacter species. Based on these results, the developed immunochromatographic strip assay is efficient for the detection of C. sakazakii and has high potential for on-site detection.

Development of a Test Strip Reader for a Lateral Flow Membrane-based Immunochromatographic Assay

  • Park, Je-Kyun;Kim, Suhyeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권2호
    • /
    • pp.127-131
    • /
    • 2004
  • A low-cost, simple strip reader system using a linear movement mechanism of CD-ROM deck has been developed to characterize a lateral flow membrane-based immunochromatographic assay. The test strip reader was assembled by a CD-ROM deck and home-made optical head especially designed for immunoassays. The optical head for detecting reflected light from the test strip surface consists of green light-emitting diode, large area silicon photodiode, and anodized aluminum mounting block providing a slit structure for cutting light from the LED. The stepping motor of the deck was operated in the full step mode, whose distance of each reading point is about 0.15mm. The performance of the strip reader was tested by analysis of HBV(hepatitis B virus) antigen test kit. This strip reader can be useful for inexpensive, disposable, and membrane-based assays that provide visual evidence of the presence of an analyte in a liquid sample.

Hepatitis B Surface Antigen을 신속히 검출하기 위한 Immunochromatographic Assay kit의 성능 평가 (The Evaluation of Immunochromatographic Assay kit for Rapid Detection of Hepatitis B Surface Antigen)

  • 신형순;김영봉;신정우;김창규;이왕식;김한겸;신광순
    • 대한바이러스학회지
    • /
    • 제27권2호
    • /
    • pp.137-141
    • /
    • 1997
  • We evaluated Immunochromatographic assay kit to screen HBsAg in human serum. When the reference HBsAg was applyed to ICA, HA and EIA kits, the limit of detection for HBsAg were found out to be 4, 2 and 0.25 ng/ml respectively. But ICA kit required 5 minutes to read the result whereas HA and EIA kit more than one hour. The sensitivity was 97% (29 of 30 samples) and the specificity 100% (45 samples) compared with conventional EIA. The ICA kit needs no instrument or machine to perform the test contrary to the conventional methods. Therefore, this rapid and sensitive ICA kit can be used for HBsAg-screening, especially in the emergency room and in the scene of the accident.

  • PDF

컴퓨터 상 분석을 이용한 HBsAg-screening용 Rapid Immunochromatographic Assay Kit의 정량적 측정법 (Quantitative Method of Rapid Immunochromatographic Assay Kit for HBsAg-screening using Computer Image Analysis)

  • 신형순;허태련
    • KSBB Journal
    • /
    • 제15권3호
    • /
    • pp.243-246
    • /
    • 2000
  • B형간염 바이러스 연구에 관한 최근의 주제는 혈중 B형간염 표면항원농도(HBsAg)를 예후 판정의 지표로 활용하는 것이다, 본 연구에서는 B형간염에 대한 자가진단을 목적으로 하여 컴퓨 터 상 분석 기법을 사용하는 HBsAg에 대한 정량적 면역크로마 토그래피 측정법을 개발하였다. 본 방법을 사용하였을 때 측정 된 integrated optical density(IOD)은 2~200 ng/mL의 범위 내에 서 표준 HBsAg 농도의 log값에 비례하여 증가하였데, ELISA 측정법은 0.1~100 ng/mL의 범위 내에서 표준 HBsAg 농도의 log값에 비례하여 증가하였다. 3개의 혈청 겸제를 가지고 두 가 지의 측정법으로 각각 시험하여 표준곡선에 대입하였을 때 동일 한 농도를 나타내 었는데 그 값이 각각 9,000, 7,000, 4,000 ng/mL 이었다. 또한 컴퓨터 상 분석 기법을 사용하는 HBsAg에 대한 정량적 면역크로마토그래피 측정법으로 동일 겸체를 5회 반복 시험하였을 때 측정된 IOD값이 재현성이 있었으며, 변이계수가 1.38 ~ 6.30% 이내였다.

  • PDF

Comparison of an Immunochromatographic Assay Kit with DAS-ELISA for Large-Scale Diagnosis and Molecular Discrimination of Satsuma Dwarf Virus Collected from Citrus Orchards

  • Kato, Mitsuhiro;Tomimura, Kenta;Ishii, Kanako
    • The Plant Pathology Journal
    • /
    • 제36권5호
    • /
    • pp.509-514
    • /
    • 2020
  • Satsuma dwarf virus (SDV) seriously damages citrus production by reducing the quality and yield of fruit. To avoid contamination with SDV, mother trees are checked to be SDV-free in advance of nursery tree distribution. In this study, we compared an immunochromatographic assay (ICA) kit with double-antibody sandwich enzyme-linked immunosorbent assay (DAS-ELISA) for large-scale diagnosis of SDV in orchardgrown trees in Shizuoka Prefecture, Japan. The two methods gave conflicting results for 11 of 1,705 samples, all of which were negative by DAS-ELISA but positive by ICA. The samples scored as positive by either DAS-ELISA or ICA were analyzed by reverse transcription polymerase chain reaction and all were confirmed to be positive. These results validate the use of ICA as a screening method for large-scale diagnosis. Strain discrimination revealed that 16 of 22 isolates belonged to SDV, while citrus mosaic virus (CiMV) infection only and co-infection (SDV and CiMV) were in a minority.

면역크로마토그래피법을 이용한 B형간염 진단용 kit의 개발 (Development of Diagnostic kit for Hepatitis B Susrface Antigen using Immunochromatographic Assay Method)

  • 신형순;신광순;정홍근;허태련
    • KSBB Journal
    • /
    • 제15권2호
    • /
    • pp.214-218
    • /
    • 2000
  • 면역크로마토그래피 진단방법을 이용하는 B형간염 스크리닝 kit를 개발하기 위하여 두가지의 항체를 이용하였다. 표식자항체로 사용된 것은 단세포군항체 anti-HBs이고 포획항체는 goat anti-HBs 인데 포획항체는 니트로셀룰로즈 막에 고정되고 표식자항체는 금 입자에 결합된다. 혈청 검체를 well에 가하면 유리섬유 표면에 건조상태로 침착되어 있던 conjugate가 활성화되어 검체중의 HBsAg와 결합한다. 검체를 가한 지 5분 후 검사결과가 나타나는데 HBsAg와 conjugate가 결합된 복합체가 니트로셀롤로즈 막의 하단부에 붉은 색 선으로 나타난다. 본 kit의 검출한계는 표준 HBs-Ag 용액을 사용하여 시험하였을 때 2 ng/ml이었다.

  • PDF