• 제목/요약/키워드: immediate implant

검색결과 271건 처리시간 0.022초

Postoperative irradiation after implant placement: A pilot study for prosthetic reconstruction

  • Doh, Re-Mee;Kim, Sungtae;Keum, Ki Chang;Kim, Jun Won;Shim, June-Sung;Jung, Han-Sung;Park, Kyeong-Mee;Chung, Moon-Kyu
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.363-371
    • /
    • 2016
  • PURPOSE. On maxillofacial tumor patients, oral implant placement prior to postoperative radiotherapy can shorten the period of prosthetic reconstruction. There is still lack of research on effects of post-implant radiotherapy such as healing process or loading time, which is important for prosthodontic treatment planning. Therefore, this study evaluated the effects of post-implant local irradiation on the osseointegration of implants during different healing stages. MATERIALS AND METHODS. Custom-made implants were placed bilaterally on maxillary posterior edentulous area 4 weeks after extraction of the maxillary first molars in Forty-eight Sprague-Dawley rats. Experimental group (exp.) received radiation after implant surgery and the other group (control) didn't. Each group was divided into three sub-groups according to the healing time (2, 4, and 8 week) from implant placement. The exp. group 1, 2 received 15-Gy radiation 1 day after implant placement (immediate irradiation). The exp. group 3 received 15-Gy radiation 4 weeks after implant placement (delayed irradiation). RESULTS. The bone mineral density (BMD) was significantly lower in the immediate irradiation groups. BMD was similar in the delayed irradiation group and the control group. The irradiated groups exhibited a lower bone-to-implant contact ratio, although the difference was not statistically significant. The irradiated groups also exhibited a significantly lower bone volume and higher empty lacuna count than the control groups. No implant failure due to local irradiation was found in this study. CONCLUSION. Within the limits of this study, the timing of local irradiation critically influences the bone healing mechanism, which is related to loading time of prostheses.

Autogenous fresh demineralized tooth graft prepared at chairside for dental implant

  • Kim, Eun-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.8.1-8.6
    • /
    • 2015
  • Background: This study aimed to evaluate the clinical usefulness of autogenous fresh demineralized tooth (auto-FDT) graft prepared at the chairside for alveolar bone grafting during dental implant surgery. Methods: In total, 38 patients requiring both tooth extraction (for endodontic or periodontal reasons or third molar extraction) and alveolar bone regeneration for dental implant placement were included. Within 2 h after clean extraction, the teeth were prepared at the chairside to serve as bone graft material. In the same sitting, blocks or chips of this graft material were used to reconstruct defects at the osteotomy site simultaneously with or before implant placement. Twelve months after prosthesis fabrication and placement, the clinical findings and implant success rates were evaluated. Histological studies were randomly conducted for selected cases. Results: Clinical evaluation showed favorable wound healing with minimal complications and good bone support for the implants. No implant was lost after 12 months of function following prosthetic rehabilitation. Histological examination revealed new bone formation induced by the graft material. Conclusions: Chairside preparation of autogenous fresh demineralized teeth after extraction can be a useful alternative to the use of autogenous bone or other graft materials for the immediate reconstruction of alveolar bone defects to facilitate subsequent implant placement.

A HISTOLOGIC STUDY OF THE OSSEOINTEGRATION PROCESS TO THE TITANIUM TOOTH ROOT IMPLANT (타이타늄 치근형 매식체에 대한 골유착 과정에 관한 조직학적 연구)

  • Ahn, Chang Young;Kim, Yung Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제28권2호
    • /
    • pp.1-28
    • /
    • 1990
  • The severe atrophic edentulism with poor neuromuscular control militates against successful conventional denture therapy. To such situation, a prescribing of dental implant treatment has been considered with some probability. Implant materials used as a trial for dental implants includes metals, plastic polymers and ceramics. The purpose of this study was to observe histologic response in osseointegration process at titanium implant-tissue interface based on biocompatibility at specific period of sequential natures which were divided into a half month, one, month, two months, three months and immediate as a base line. In this study, unilateral lower left premolar and molar teeth were extraced in three dogs. After allowing to heal for 6 months, three kinds of osseointegrated implant, $Br{\aa}nemark$, Corevent and kimplant(a prototype of SNU implant study)were inserted in each dog respectively according to the above sequence from front to back. The specimens were taken from those dogs at the same time since implant were inserted quite reverse order of the specified periods, and decalcified and processed for histologic examination for the light microscopy and the electron microscopy. The microscopic histologic findings at the interface between titanium implants and tissue were interpretated as follows : A. Light microscopic findings : a. Immediate : Implant were surrounded by compact bone and spongy bone. Microcrak was observed in the superficial bone tissue. Osteocytes were disappeared and bone lacunae were observed as a vacant space in some parts. In the contacting with the spongy bone, bone trabeculae and bone marrow were in contact with the implant. b. A half Month : Osteoblasts exist as a monolayer in th inner bone trabeculae and do bone additiocn. Osteoblasts&inflammatory cells were observed in some parts. c. One Month : The presence of osteoclasts decreased. Osteoblasts did active bone fromation, and bone marrow was in contact with the implant in the many places. d. Two Months : Bone formation was advanced in comparison with the b and c. The presence of osteoclsts was not observed. e. Three Months : The superficial bone tissue contacted with the implants was entirely composed by the compact bone. B. Electron microscopic findings : a. A half month and one month group : In the parts of the active bone formation, osteoblasts with the well developed endoplasmic reticulum and Golgi apparatus were arranged in the monolayer. In the parts of the bone resorption, ruffled border was well developed and many osteoclasts with the well-developed golgi apparatus, mitochondria, vacuole, vesicle and lysosome were existed. b. Three months group : No osteoblasts were observed in the superficial bone tissue. Bone matrix with collaen fiber was observed. c. No significant dirrerence in the histologic findings was observed in $Br{\aa}nemark$, Core-vent and kimplant.

  • PDF

Ridge split for implant placement in very thin alveolar ridge (매우 얇은 치조골에서 치조능 분할 확장술을 통한 임플란트 치료)

  • Kim, Sin-Guen;Lee, Hee-Sung;Park, Jong-Wook;Nam, Jong-Hoon;Bok, Sung-Cheol;Park, Ki-Nam;Choi, Dong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권3호
    • /
    • pp.229-233
    • /
    • 2011
  • For implant treatment there must be sufficient bone to house the implant body. At least 5mm wide residual bone is needed and usually a 6mm width is preferred by clinicians. However, surgeons sometimes find patients with a narrow ridge, which makes it difficult to place an implant. Therefore, many clinicians perform bone graft or a ridge splitting technique to overcome these poor conditions. The time and cost can be reduced using the ridge splitting technique with immediate implant placement. Recently, many studies reported reliable consequences of ridge splitting technique. This paper reports a successful of implant placement with a ridge splitting technique in a very thin alveolar ridge.

The Lazy S Design: A Novel Skin Closure Design in Skin-Sparing Mastectomy for Implant-Based Breast Reconstruction

  • Kim, June-Kyu;Kim, Yong Seong
    • Archives of Plastic Surgery
    • /
    • 제44권4호
    • /
    • pp.344-347
    • /
    • 2017
  • Preservation of the breast skin envelope during immediate implant-based breast reconstruction is important for producing symmetrical and natural-looking breasts. We propose the lazy S design for the closure of round-shaped wounds with the hope of improving the aesthetic outcomes and reducing the tension on the wound by preserving the skin. Additionally, the direction of tension is dispersed due to the shape of this design. Patients undergoing implant reconstruction after skin-sparing mastectomy may benefit from the lazy S design.

Single-tooth implant restoration with alveolar bone augmentation in the maxillary anterior tooth region: a case report

  • Lee, Seon-Ki
    • International Journal of Oral Biology
    • /
    • 제46권4호
    • /
    • pp.200-207
    • /
    • 2021
  • In case of gingival recession and alveolar bone defects due to tooth loss for a long period of time in a single tooth in the maxillary anterior region, it is not easy to obtain aesthetic results with a single implant prosthesis. For aesthetic restoration, it is important to preserve hard and soft tissues through alveolar bone augmentation as well as restore harmony with adjacent teeth and soft tissues by placing the implant in an ideal location. In this case, an implant was placed using guided bone regeneration and a connective tissue graft simultaneously with immediate implantation after extraction from the maxillary anterior region where only residual root was left for a long period of time.

The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets

  • Jun, Sang Ho;Park, Chang-Joo;Hwang, Suk-Hyun;Lee, Youn Ki;Zhou, Cong;Jang, Hyon-Seok;Ryu, Jae-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.8.1-8.6
    • /
    • 2018
  • Background: This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Methods: Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. Results: The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg (R = 0.606, P = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Conclusions: Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.

HISTOLOGICAL COMPARISONS OF TITANIUM PLASMA SPRAYED IMPLANT AND HYDROXYAPATITE COATED IMPLANT TO BONE INTERFACE IN PERIODONTALLY INVOLVED EXTRACTION SOCKETS IN DOGS (성견 치주질환 이환 발치와에 즉시 임플란트 매식술시 Titanium plasma sprayed 임프란트와 Hydroxyapatite coated 임프란트의 계면조직에 관한 연구)

  • Kim, Jin-Sook;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • 제23권3호
    • /
    • pp.400-410
    • /
    • 1993
  • Dental implants have been widely used in the treatment of esthetic and functional problems of the mouth due to alveolar bone loss, after tooth extraction. The success of implantation strongly depends on osseointegration. For osseointegration, implant material, methodology, and design have been investigated. For materials, two popular materials at present are titanium and hydroxyapatite. For methods, immediate implantation is being used recently. The purpose of this study is to evaluate osseointegration between the unthreaded cylindrical TPS implant and the HA-coated implant by a histomorphometric analysis. For this analysis, experimental periodontits was induced on the 3, 4 premolars of adult dogs by the ligation of orthodontic threads. Thereafter, each tooth was extracted. TPS. Implants and HA-coated implants were immediately inserted in the extraction socket. In control group, TPS implants were immediately inserted, and In experimental group, HA implants were immediately inserted. The dogs were sacrificed after 12 weeks, then the specimens were prepared for LM and histomorphometric analysis. The conclusion of this study is as follows l. In both control and experimental group, no inflammatory cells were observed. 2. The results of the histomorphometric analysis showed that the total osseointegration was 48.5% in control group, and 68.8% in expermental group. The experimental group was higher than the control group, and the difference was not statistically significant (p<0.05). 3. The results of the histomorphometric analysis showed that the osseointegration in the hole was 40.6% in control group, and 70.2% in experimental group. The experimental group was higher than the control group, and the difference was statistically significant (p<0.05). In both control and experinental group, no inflammatory cells were observed. 4. The results of the histomorphometric analysis showed that the osseointegration in the lower part was 52.1% in control group, and 73.3% in experimental group. The experimental group was higher than the control group, and the difference was statistically significant (p<0.05). 5. In experimental group, the bone to HA interface seemed to be mixed of bone and HA. We could not distinguish HA from the bone. The HA coating was detached from the titanium surface.

  • PDF

Comparative Study Of Osseointergration On Different Immediate Implants In Extraction Sockets Of Beagle Dogs (성견에 발치 후 즉시 임플란트 식립시 RBM 처리된 임플란트의 골융합에 관한 연구)

  • Sun, Ki-Jong;Park, Jae-Young;Jung, Eun-Gyeong;Shin, Mee-Ran;Kim, Yun-Sang;Pi, Sung-Hee;Shin, Hyung-shik;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.209-221
    • /
    • 2007
  • Recently, immediately after losing teeth. implant placement has been greatly attempted. Implant can help restoration of tooth functions within short time. This study was an attempt to examine the extent of osseointergation when the implants will be placed immediately after teeth extraction using domestic implant systems. Implants were inserted in beagle dogs and evaluated the clinical, radiological, histological and histomorphometric assay at 6 weeks and 12 weeks. For experimental materals, $STAGE-1^{(R)}$($4.1{\times}8mm$, Lifecore, USA), $SS-III^{(R)}$($4.0{\times}8mm$, OSSTEM, Korea) and $IFI^{(R)}$($4.0{\times}8mm$, Dio, Korea) implants treated with RBM were placed. All the placed site showed normal results without fail and inflammation clinically and radiologically. As a result of measurement by periotest, it showed $-2\;{\sim}\;-5$ and stable status comprehensively. There was no statistically significant difference among implants(p<0.05). Bone tissue adjacent to implant showed increased marrow tissue at 6 weeks. Nevertheless, osteogenic structure was not observed remarkably. In a 12 weeks opinion, bone tissue composed of osseointegration along implant interface showed significantly decreased marrow tissue containing central vessels unlike a 6 weeks opinion and matured compact bone whose osteogenic structure is well formed. BIC were 42.4%, 32.0% and 34.9%, respectively in 6 weeks and there was no statistically significant difference among group(p<0.05). In 12 weeks, BIC were 58.8%, 61.9% and 57.5%. respectively and there was no statistically significant difference among groups(p<0.05). It is considered that all 3 implant systems are suitable for immediate implant placement.

Immediate Connection of Customized Zirconia Abutment Using Flapless Guided Surgery: A Clinical Report (무절개 수술을 이용한 맞춤형 지르코니아 지대주의 즉시 장착 증례)

  • Lee, Gyeong-Je;Choi, Byung-Ho;Kim, Hee-Jun;Jung, Seng-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제28권2호
    • /
    • pp.201-212
    • /
    • 2012
  • There are some similar aspects at histological and morphological characteristics between the peri-implant tissue and periodontal tissue and the direct attachment between the titanium and soft tissue around the implant called as "Functional ankylosis" can prevent the apical infiltration of inflammatory and bone resorption around implant. But, the repeated connection and disconnection of the abutment can destroy the mucosal barrier of soft tissue around the implant and can cause the marginal bone resorption. The amount of marginal bone resorption may reduced if the prosthetic abutment is placed at that time of surgery. Connection of the prosthetic abutment at surgery was limited because the low accuracy of conventional method, but by using of Cone Beam Computed Tomography(CBCT) and guide surgery, the 3-dimensional accuracy of implant placement became much higher than before and it became possible. This is a clinical case of immediate connection of prosthetic abutment and provisional restoration by using of precise CBCT diagnosis and pre-fabricated zirconia customized abutment at surgery and the alternative method is described in this article because of the clinically contentable results.