• Title/Summary/Keyword: imbalance ratio

Search Result 216, Processing Time 0.052 seconds

Comparison of the Strength of the Ankle Evertor, Invertor, and Ratio at Different Ankle and Toe Positions Between Sides With and Without Chronic Ankle Instability in Taekwondo Athletes

  • Beom-jun Kim;Ui-jae Hwang;Oh-yun Kwon
    • Physical Therapy Korea
    • /
    • v.31 no.2
    • /
    • pp.151-158
    • /
    • 2024
  • Background: In Taekwondo athletes, ankle sprain is the most common risk factor for injury. Repeated ankle injuries lead to weakness and imbalance of the ankle muscles, resulting in chronic ankle instability (CAI). Both the ankle and toe muscles contribute to the inversion and eversion of the foot at the subtalar joint. Therefore, it is necessary to consider the ankle and toe joint positions when measuring ankle invertor and evertor strength. Objects: This study aimed to compare the muscle strength and ratio differences of the ankle invertor and evertor muscles in both the toe and ankle positions between the CAI and uninjured sides in Taekwondo athletes. Methods: Fifteen Taekwondo athletes participated in this study. The isometric strengths of both the ankle invertor and evertor were determined in different ankle and toe positions (dorsiflexion with toe extension, dorsiflexion with toe flexion, plantarflexion with toe extension, and plantarflexion with toe flexion). Paired t-tests were used to determine the differences between the ankle invertor and evertor in strength and ratio according to toe and ankle positions between the ankle CAI side and the uninjured side. Results: The results demonstrated that ankle evertor strength significantly decreased in all ankle and toe positions on the CAI side (p < 0.05). In addition, significant differences were observed in the ratios of the ankle invertor and evertor strengths in the dorsiflexion with toe flexion, plantarflexion with toe extension, and plantarflexion with toe flexion positions (p < 0.05). Conclusion: The findings of this study suggest that athletes, trainers, and clinicians should consider ankle and toe positions when measuring invertor and evertor strength and develop ankle rehabilitation protocols for Taekwondo athletes with CAI.

Cross Flow Characteristics of the Core Simulator in SMART Reactor Flow Distribution Test Facility (SMART 유동분포시험장치 노심모의기에서의 횡방향 유동 특성)

  • Yoon, Jung;Kim, Young-In;Chung, Young-Jong;Lee, Won-Jae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.5-11
    • /
    • 2012
  • To identify the flow characteristics of the SMART reactor, a flow distribution model test and a numerical simulation are performed in KAERI. Among several part of the SMART reactor, the fuel assemblies are simulated using simulators because of the complexity. The geometries of the core in the SMART reactor and simulator are different, but some similarities are maintained such as the ratio of pressure drop in the vertical and cross directions. There are cross flow holes in each core simulator to reproduce the cross flow of SMART fuel assemblies. To know the flow characteristics of the cross flow, numerical analysis is performed. As the cross flow area is decreased, the pressure drop between inlet and outlet is decreased. Also, when the flow imbalance between two core simulators is constant, the cross flow area does not significantly affect the cross flow.

Influence of Trunk Stabilization Exercise upon the Lumbar Stabilization and Foot Pressure in Patients with Back Pain (체간 안정화 운동이 요통환자의 요부안정성과 족저압에 미치는 영향)

  • Lee, Woo-Jin;Park, Seol;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.1
    • /
    • pp.21-26
    • /
    • 2014
  • Purpose: This study examined the effect of trunk stabilization exercise upon the lumbar stabilization and foot pressure on an unstable surface with back pain. Methods: The subjects of the study were 10 patients who showed the symptom of back pain with excessive lumbar curve. This study was 4 weeks, 30 minutes per session, three times a week for a total of 12 times as a result of exercise radiation imaging device and foot pressure analyzer. Results: The sacrohorizontal angle was statistically significant(p<0.05). Comparison of the difference between static right and left foot pressure ratio analysis was statistically significant(p<0.05). Dynamic right and left foot pressure comparisons for the difference was statistically significant in the analysis (p<0.05). Conclusion: Trunk stabilization exercise and the reduction of the excessive sacrohorizontal angle, and static and dynamic foot pressure imbalance reduced left and right.

A Game Placement Method Considering Load Balancing between Game Servers in a Game Server Cluster (게임 서버 클러스터에서 서버들간의 부하 균형을 고려한 게임 배치 방법)

  • Che, Zhong-Yong;Kim, Sang-Chul
    • Journal of Korea Game Society
    • /
    • v.12 no.3
    • /
    • pp.49-58
    • /
    • 2012
  • When a company provides new games or games with a small number of users, it is convenient to provide the game service in which those games are placed in a server cluster instead of a separate server for an individual game. This paper proposes a method for placing games in a cluster of servers with the same capacities. The method reduces the load imbalance among servers and minimizes the rejection ratio of user requests. We expect that the proposed method is useful for determining the server operation factors such as the number of servers, the number of games for a server, etc. To our survey, little research has been published on game placement on a cluster of game servers.

Experimental Study of Three-Dimensional Turbulent Flow in a $90^{\circ}C$ Rectanglar Cross Sectional Strongly Curved Duct (직사각형 단면을 갖는 $90^{\circ}C$ 급곡관 내의 3차원 난류유동에 관한 실험적 연구)

  • 맹주성;류명석;양시영;장용준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.262-273
    • /
    • 1991
  • In the present study, the steady, incompressible, isothermal, developing flow in a 90.deg. rectangular cross sectional strongly curved duct with aspect ratio 1:1.5 and Reynolds number of 9.4*10$^{4}$ has been investigated. Measurements of components of mean velocities, pressures, and corresponding components of the Reynolds stress tensor are obtained with a hot-wire anemometer and pitot tube. In general, flow in a curved duct is characterized by the secondary vortices which are driven mainly by centrifugal force-radial pressure gradient imbalance, and the stress field stabilizing effects near the convex wall and destablizing effects close to the concave wall. It was found that the secondary mean velocities attain values up to 39% of the bulk velocity and are largely responsible for the convections of Reynolds stress in the cross stream plane. Therefor upstream of the bend the Reynolds stress are low. Corresponding to the small boundary layer thickness. At successive planes, large values of Reynolds stress were observed near the concave surface and the side wall.

A study on the improvement of the local stress field in a displacement-formulated finite element solution (변위형 유한요소 해에서 국부응력장 향상에 대한 연구)

  • Song, Kee-Nam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.278-288
    • /
    • 1998
  • An efficient and useful method to improve the local stress field in a displacement-formulated finite element solution has been proposed using the theory of conjugate approximations for a stress field and the Loubignac's iterative method for a displacement field. Validity of the proposed method has been tested through three test examples, to improve the stress field and displacement field in the whole domain and the local regions. As a result of analysis on the test examples, it is found that the stress field in the local regions are approximated to those in the whole domain within a few iterations which have satisfied the original finite element equilibrium equation. In addition, it is found that the local stress field are by far better approximated to the exact stress field than the displacement-based stress field with the reduction of the finite-element mesh-size.

A study on the improvement of the local stress field using the theory of conjugate approximations and loubignac's iterative method (공액근사개념과 Loubignac의 반복계산법을 이용한 국부응력장 개선에 대한 연구)

  • Song, Kee-Nam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.10
    • /
    • pp.1598-1608
    • /
    • 1997
  • Based on the application of te theory of conjugate approximations and the Loubignac's iterative method in a local region, a method to improve the stress filed in a displacement-formulated finite element solution has been proposed. The validity of the proposed method has been tested through two examples : a thick cylinder under internal pressure loading and an infinite plate with a central circular hole subjected to uniaxial tension. As a result of analysis of the examples, it was found that the stress field obtained for the local region model by the proposed method approximates well for the whole domain model. In addition, it was found that because of a significant decrease in the computing time to obtain the improved stress field, the proposed method is efficient and useful for the detailed stress analysis in local regions.

A Study on the Impact of HVDC Transmission System to Interconnect Large-scale Power Generation Plants to Power Grid in Korea (HVDC 송전을 이용한 동해안 신규전원의 수도권 계통 연계방안에 대한 연구)

  • Han, Su-Young;Gwon, Do-Hun;Chung, Il-Yop;Lim, Jae-Bong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1647-1656
    • /
    • 2013
  • Although the demand for electricity has been increasing these days, it becomes more difficult to find new sites for large-scale power generation plants near urban areas due to environmental and economic issues. Therefore, new power plants are forced off to rural or desolate coastal areas. As a result, there is significant regional imbalance in power generation and consumption between urban and rural areas in South Korea. This paper investigates the feasibility of high-voltage DC (HVDC) system as a candidate for electric power transmission system from east-coastal sites to metropolitan area. To this end, this paper analyzes transient stability and dynamic impact of a HVDC transmission system and compares the results to conventional high-voltage AC (HVAC) transmission systems via PSS/E simulation. This paper also examines the effect of HVDC system to voltage variation and low-frequency resonance in the neighboring buses in the grid using ESCR(Effective Short Circuit Ratio)과 UIF(Unit Interaction Factor) indices.

Status of Anaerobic Digestion Facility for Pig-slurry in Korea (국내 가축분뇨 혐기소화시설 현황 및 운영실태 분석)

  • Jeong, Kwang-Hwa;Kim, Jung-Gon;Han, Duk-Woo;Kwag, Jung-Hun
    • Journal of Animal Environmental Science
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2014
  • This study was conducted to survey and inspect the currently operating anaerobic digestion facilities for animal manure. Recently, the number of anaerobic digestion facility for livestock manure is on the rise thanks to growing interest in developing alternative energy. A anaerobic digestion system has been constructed in large scale farms or animal manure public resource center. Currently, most animal manure anaerobic digestion facilities in operation are producing biogas from the pig slurry which contains 97% water. Methane gas can be used to operate a engine generator which then produces electricity. Anaerobic digestate, a by-product of digestion, is mostly utilized as a liquid fertilizer after curing processing. Only in a few cases, it can be discharged after wastewater treatment process. The problem of anaerobic digestate treatment is the imbalance of C/N ratio. The content of N was too high to keep it into normal process.

An Experimental Study on Investigation for Application of High Quality Recycled Fine Aggregate Produced by Dry Manufacturing Method (건식제조법에 의해 생산된 고품질 재생산골재의 활용성 검토를 위한 실험적 연구)

  • Moon Hyung-Jae;Koo Gyung-Mo;Roh Kyung-Min;Cho Bong-Suk;Kim Gyu-Yong;Kim Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.29-32
    • /
    • 2005
  • Recently, for the problem solution of demand and supply imbalance of fine aggregate due to the shortage of natural fine aggregate and the environment regulation on sea sand extraction in the construction field, the studies for the application of recycled fine aggregate using waste concrete are being progressed versatilely. The purpose of this study is to investigate quality of recycled fine aggregate manufactured by drying manufacturing system which is the manufacture method of high duality recycled fine aggregate, and to analyze on thehardened and durability properties of recycled concrete using it. Therefore it is to present the fundamental data for application and utilization of recycled concrete. The results of this study are as follows; Quality of recycled fine aggregate by drying manufacturing system is improved, and compressive strength, carbonation depth and chloride ion penetration depth of recycled concrete using high quality recycled fine aggregate are similar to those of normal concrete using natural and crashed sand. But, resistance to $H_{2}SO_{4}$ show decreased somewhat.

  • PDF