• Title/Summary/Keyword: imaging physics

Search Result 635, Processing Time 0.027 seconds

EXPERIMENTAL RESEARCH ON VIBRATING PLATE AND ITS RADIATION FIELD USING NEARFIELD ACOUSTIC HOLOGRAPHY

  • D.J. Zhang;J.Z. Cheng;N.Q. Zuh;Q. Wang;X.H> Xia
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.842-847
    • /
    • 1994
  • This paper presents the nearfield acoustic holography (NAH) imaging system for airborne sound constructed in our own laboratory. The effects of different kinds of noise and the filter function's form in wave number space for reconstructions are analysed emphatically. Using the system we have measured the vibrating mode and the radiated field of a simulative "Chime Stone" made by metal, and gotten interesting results. These results indicate that NAH can be used to research the mechanism of sound production and evalution of musical quality for Chime Stone as an effective means.

  • PDF

Visibility of Internal Target Volume of Dynamic Tumors in Free-breathing Cone-beam Computed Tomography for Image Guided Radiation Therapy

  • Kauweloa, Kevin I.;Park, Justin C.;Sandhu, Ajay;Pawlicki, Todd;Song, Bongyong;Song, William Y.
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.220-229
    • /
    • 2013
  • Respiratory-induced dynamic tumors render free-breathing cone-beam computed tomography (FBCBCT) images with motion artifacts complicating the task of quantifying the internal target volume (ITV). The purpose of this paper is to study the visibility of the revealed ITV when the imaging dose parameters, such as the kVp and mAs, are varied. The $Trilogy^{TM}$ linear accelerator with an On-Board Imaging ($OBI^{TM}$) system was used to acquire low-imaging-dose-mode (LIDM: 110 kVp, 20 mA, 20 ms/frame) and high-imaging-dose-mode (HIDM: 125 kVp, 80 mA, 25 ms/frame) FBCBCT images of a 3-cm diameter sphere (density=0.855 $g/cm^3$) moving in accordance to various sinusoidal breathing patterns, each with an unique inhalation-to-exhalation (I/E) ratio, amplitude, and period. In terms of image ITV contrast, there was a small overall average change of the ITV contrast when going from HIDM to LIDM of $6.5{\pm}5.1%$ for all breathing patterns. As for the ITV visible volume measurements, there was an insignificant difference between the ITV of both the LIDM- and HIDM-FBCBCT images with an average difference of $0.5{\pm}0.5%$, for all cases, despite the large difference in the imaging dose (approximately five-fold difference of ~0.8 and 4 cGy/scan). That indicates that the ITV visibility is not very sensitive to changes in imaging dose. However, both of the FBCBCT consistently underestimated the true ITV dimensions by up to 34.8% irrespective of the imaging dose mode due to significant motion artifacts, and thus, this imaging technique is not adequate to accurately visualize the ITV for image guidance. Due to the insignificant impact of imaging dose on ITV visibility, a plausible, alternative strategy would be to acquire more X-ray projections at the LIDM setting to allow 4DCBCT imaging to better define the ITV, and at the same time, maintain a reasonable imaging dose, i.e., comparable to a single HIDM-FBCBCT scan.

Motility Contrast Imaging for Drug Screening Applications

  • Jeong, Kwan
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.382-389
    • /
    • 2015
  • Motility contrast imaging is a coherence-domain imaging technique that uses cellular motility as a fully endogenous imaging contrast agent. Motility is measured inside tissue using a digital holographic coherence gate that extracts dynamic speckle from fixed depths. The dynamic speckle arises from the normal organelle motion inside cells, and from the movement of the cellular membranes driven by the cytoskeleton. It measures cellular activity and the effects of temperature and osmolarity. Motion is sensitive to cytoskeletal drugs, such as the antimitotic drugs used for cancer chemotherapy, and the effects of drug combinations also can be monitored. Motility contrast imaging is a potential tissue-based assay platform for highthroughput screening of pharmaceuticals.

Optical System Design and Image Processing for Hyperspectral Imaging Systems (초분광 분해기의 광학계 설계 및 영상 처리)

  • Heo, A-Young;Choi, Seung-Won;Lee, Jae-Hoon;Kim, Tae-Hyeong;Park, Dong-Jo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.328-335
    • /
    • 2010
  • A hyperspectral imaging spectrometer has shown significant advantages in performance over other existing ones for remote sensing applications. It can collect hundreds of narrow, adjacent spectral bands for each image, which provides a wealth of information on unique spectral characteristics of objects. We have developed a compact hyperspectral imaging system that successively shows high spatial and spectral resolutions and fast data processing performance. In this paper, we present an overview of the hyperspectral imaging system including the strucure of geometrical optics and several image processing schemes such as wavelength calibration and noise reduction for image data on Visible and Near-Infrared(VNIR) and Shortwave-Infrared(SWIR) band.

A Method to Destripe Imaging Spectroradiometer Data of SZ-3

  • Xiaoxiang, Zhu;Tianxi, Fan;Qian, Huang
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1278-1280
    • /
    • 2003
  • Striping is a main factor for imaging spectroradiometer data, which is obtained by multi-sensor scanning on spacecraft. The reason causing stripes and the development of striping removal methods are simply described in this paper, particularly, the principle of Matching Empirical Distribution Functions is introduced in detail. By using this method, some experiments are done to destripe imaging spectrometer data of SZ-3. The result shows that the method of Matching Empirical Distribution Functions is available for destirping Imaging spectroradiometer data of SZ-3, and the quality of image is improved obviously. This will help to process the future similar instruments data.

  • PDF

The Response of the Solar Chromosphere and Transition Region to a Coronal Rain Event

  • Kwak, Hannah;Chae, Jongchul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.83.4-84
    • /
    • 2015
  • We report that a strong downflow event caused three-minute oscillations in the solar atmosphere. Our observations were carried out by using the Fast Imaging Solar Spectrograph (FISS) of the 1.6 meter New Solar Telescope (NST) and the Interface Region Imaging Spectrograph (IRIS). Our main findings are as follows: (1) The strong downflow was seen at the $H{\alpha}$ absorption line at first, and then appeared at the Si IV and C II emission lines. It seems that the characteristics of the downflow are consistent with a coronal rain event. (2) After the event, oscillations of velocity were identified in the chromospheric lines and transition region lines. (3) The amplitudes of oscillations were 2km/s at Mg II line and 3km/s at C II and Si IV lines and decreased with time. (4) The period of the oscillation was 2.67 minutes at first, but gradually increased with time. Our findings are in agreement with Chae & Goode (2015)'s theory that of acoustic waves generated by a disturbance in a gravitationally-stratified medium.

  • PDF

Point Spread Function of Optical Systems Apodized by Semicircular Array of 2D Aperture Functions with Asymmetric Apodization

  • Reddy, Andra Naresh Kumar;Sagar, Dasari Karuna
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.2
    • /
    • pp.83-88
    • /
    • 2014
  • The simultaneous suppression of sidelobes and the sharpening of the central peak in the process of diffraction pattern detection based on asymmetric apodization have been investigated. Asymmetric apodization is applied to a semicircular array of two-dimensional (2D) aperture functions, which is a series of 'coded-phase arrays of semicircular rings randomly distributed over the central circular region of a pupil function' and is similar to that used in the field of diffractive optics. The point spread function (PSF) of an imaging system with asymmetric apodization of the discrete type has been found to possess a good side with suppressed sidelobes, whereas its bad side contains enhanced sidelobes. Further, the diffracted field characteristics are obtained in the presence of these aperture functions. Asymmetric apodization is helpful in improving the performance of the optical gratings or 2D arrays used in real-time imaging techniques.

Development of On-line Portal Imaging System and its Linearity (온라인 방사선 치료 조사야 영상 시스템의 제작과 선형성 조사)

  • 김성환;김재철;박인규
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.77-85
    • /
    • 1997
  • Verification of patients setup was very important during radiotherapy. Therefore, we have developed an 1-dimensional on-line portal imaging system and measured the differential linearity of the system. Isooctane(2,2,4-TetraMethyl Pentane) was used as liquid ionization material. And the geometry of the system was designed which has 2mm position resolution and 20cm measurable range. And then the differential linearity of the system was 4.7%.

  • PDF

Development of Quadrature Detection Surface Coil for Functional Magnetic Resonance Imaging at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.363-364
    • /
    • 2002
  • We describe quadrature type surface coil for functional magnetic resonance imaging at 3T MRI system. The coil consisted of two coplanar resonators and was used as both transmitter and receiver. The signal-to-noise ratio (SNR) of the coil was compared with that of a standard birdcage head coil. Visual cortex activation on normal subjects using LED flicker was performed. The SNR of surface coil was found to be better than that of the conventional head coil.

  • PDF

Monte Carlo Studies on Mammography System

  • Ho, Dong-Su;Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Kim, Song-Hyun;Kim, Do-Il
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.485-488
    • /
    • 2002
  • In order to understand and quantitatively analyze the physical phenomena and behavior of each component of mammography system during the breast imaging, we simulated mammography imaging using Monte Carlo simulation codes. MCNP4B code was used for our simulation purpose, and we investigated the effect of target material, anode angle, filtration, peak voltage and exposure on the image quality of mammograms. From the simulation results we expect that optimized operation condition of mammography system can be found.

  • PDF