• 제목/요약/키워드: imaging mode

검색결과 332건 처리시간 0.034초

Isolation and Characterization of a Theta-Type Cryptic Plasmid from Bifidobacterium longum FI10564

  • Moon, Gi-Seong;Wegmann, Udo;Gunning, A. Patrick;Gasson, Michael J.;Narbad, Arjan
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권4호
    • /
    • pp.403-408
    • /
    • 2009
  • A number of bifidobacterial species of human origin were screened for the presence of cryptic plasmids. One strain, Bifidobacterium longum FI10564, harbored plasmids of approximately 2.2 kb, 3.6 kb, and 4.9 kb in size. The smallest plasmid, pFI2576(2,197 bp), was studied in detail and its complete nucleotide sequence was determined. Computer-assisted analysis of this novel plasmid(G+C content 62%) identified 9 putative open reading frames(orfs), 3 of which were shown to be probable genes. These putative genes are arranged in an operon-like structure, in which the overlapping orfs 1 and 2 encode putative Rep proteins and are highly homologous to the rep genes of the B. longum plasmid pMBI(1,847 bp). The mechanism of replication of pFI2576 was investigated using Southern blot analysis of whole cell lysates, with and without S1 nuclease treatment, and atomic force microscopy(AFM). The results indicate that pFI2576 is likely to use the theta mode of replication.

단일 센서와 공간집속 신호처리 기술을 이용한 복합재 판에서의 충격위치 결정 (Impact Localization of a Composite Plate Using a Single Transducer and Spatial Focusing Signal Processing Techniques)

  • 조성종;정현조
    • 한국소음진동공학회논문집
    • /
    • 제23권2호
    • /
    • pp.152-159
    • /
    • 2013
  • A structural health monitoring(SHM) technique for locating impact position in a composite plate is presented in this paper. The technique employs a single sensor and spatial focusing properties of time reversal(TR) and inverse filtering(IF). We first examine the focusing effect of back-propagated signal at the impact position and its surroundings through simulation. Impact experiments are then carried out and the localization images are found using the TR and IF signal processing, respectively. Both techniques provide accurate impact location results. Compared to existing techniques for locating impact or acoustic emission source, the proposed methods have the benefits of using a single sensor and not requiring knowledge of material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in the SHM of plate-like structures.

개에서 외이도의 초음파학적 평가 (Ultrasonographic Evaluation of the External Ear Canal in Dogs)

  • 이해운;엄기동;성윤상;이정민;이종원;김정은;장광호;이근우;장동우
    • 한국임상수의학회지
    • /
    • 제21권2호
    • /
    • pp.149-153
    • /
    • 2004
  • This study was to determine the procedure for ultrasonographic imaging of the canine external ear canal(ECC). By infusion of warm saline solution into the ear canal, a real-time B mode ultrasonographic examination of the ECC was performed in five healthy Beagle dogs and two dogs with severe otitis externa. The ultrasonography was very useful to detect the structures of the ECC and the tympanic membrane. An 11 NHz linear probe was permitted to assess an anechoic lumen of the ECC and a hyperechoic cartilage surrounding the ear canal. In two dogs with otitis externa, it could be assessed the ECC with ultrasonography without ear cleansing. A lumen of the ECC was irregular and a cerumen could be seen, but edematous inflammatory changes of the ECC could not be identified. The results suggest that ultrasonography of the ECC with an 11 NHz linear probe after infusing the saline solution into the ear canal may be an accurate, non-invasive, rapid, and widely available method for assessment of the ear canal diseases such as otitis externa, polyp, stenosis, hyperplasia, and foreign body in dogs.

FJB 파형을 이용한 SAR 영상 생성 기법 분석 (Analysis of SAR Processing Performances with FJB Waveforms)

  • 김은희;노지은;박준용;김수범
    • 한국전자파학회논문지
    • /
    • 제28권3호
    • /
    • pp.195-207
    • /
    • 2017
  • 항공기 레이다에서는 고해상도 SAR 영상에서 지상의 이동 표적을 탐지하는 SAR-GMTI 모드의 운영이 점점 필수적으로 되고 있다. SAR는 고해상도 영상을 위하여 광대역 파형을 필요로 하는 반면, GMTI는 도플러 추출을 위하여 협대역의 파형을 필요로 하기 때문에 일반적인 LFM 파형은 사용에 어려움이 있다. 본 논문에서는 최근 들어 SAR-GMTI 모드의 파형으로 연구되고 있는 FJB(Frequency Jump Burst) 파형의 특성을 분석하였고, FJB 파형을 사용한 펄스압축과 SAR 영상생성을 위한 방법들을 구현하였으며, 시뮬레이션을 통하여 펄스압축과 SAR 영상에서 단일 LFM을 사용할 경우와 성능에서 거의 차이가 없음을 보였다. FJB 파형은 SAR와 GMTI 처리를 동일한 파형으로 수행할 수 있기 때문에 본 결과를 적용하면 항공기 레이다에서 SAR-GMTI 모드의 처리를 보다 효율적으로 수행할 수 있다.

광전도안테나에 의한 광대역테라헤르츠파의 발생특성 (Generation of Ultra-Wideband Terahertz Pulse by Photoconductive Antenna)

  • 진윤식;김근주;손채화;정순신;김지현;전석기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권6호
    • /
    • pp.286-292
    • /
    • 2005
  • Terahertz wave is a kind of electromagnetic radiation whose frequency lies in 0.1THz $\~$10THz range. In this paper, generation and detection characteristics of terahertz (THz) radiation by photoconductive antenna (PCA) method has been described. Using modern integrated circuit techniques, micron-sized dipole antenna has been fabricated on a low-temperature grown GaAs (LT-GaAs) wafer. A mode-locked Ti:Sapphire femtosecond laser beam is guided and focused onto photoconductive antennas (emitter and detector) to generate and measure THz pulses. Ultra-wide band THz radiation with frequencies between 0.1 THz and 3 THz was observed. Terahertz field amplitude variation with antenna bias voltage, pump laser power, pump laser wavelength and probe laser power was investigated. As a primary application example. a live clover leaf was imaged with the terahertz radiation.

Specialty Fiber Coupler: Fabrications and Applications

  • Lee, Byeong-Ha;Eom, Joo-Beom;Park, Kwan-Seob;Park, Seong-Jun;Ju, Myeong-Jin
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.326-332
    • /
    • 2010
  • We review the research on specialty fiber couplers with emphasis placed on the characteristics that make them attractive for biomedical imaging, optical communications, and sensing applications. The fabrication of fiber couplers has been carried out with, in addition to conventional single mode fiber, various specialty fibers such as photonic crystal fiber, double clad fiber, and hole-assisted fiber with a Ge-doped core. For the fiber coupler fabrication, the side polishing and the fused biconical tapered methods have been developed. These specialty fiber couplers have been applied to optical coherence tomography, fluorescence spectroscopy, fiber sensors, and optical communication systems. This review aims to provide a detailed statement on the recent progress and novel applications of specialty fiber couplers.

Novel Scanning Tunneling Spectroscopy for Volatile Adborbates

  • Choi, Eun-Yeoung;Lee, Youn-Joo;Lyo, In-Whan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.58-58
    • /
    • 2010
  • Reactive or unstable adsorbates are often difficult to study spectroscopically. They may have, for instance, resonance states lying close to the Fermi level, inducing them to desorb or decompose by the probe itself, low-energy tunneling electrons. In order to overcome this limitation, we developed a novel method, which we call x-ramp scan. The method sweeps the bias voltage, with the simutaneous scan along the imaging direction, in a constant current mode. This mapping yields the tip-height variation as a function of bias, or Z(V), at nominally always fresh surface. We applied this method to the investigation of methanol-induced molecular features, attributed to methoxy, found on NiAl(110) surface. These were produced by methanol molecules deposited by a pulse injection method onto the metallic surface. Our study shows adsorbed methoxy are very reactive to the bias voltage, rendering the standard spectroscopy useless. Our new x-ramp scan shows that the decomposition of adsorbates occurs at the sample bias of 3.63 V, and proceeds with the lifetime of a few milliseconds. The details of the method will be provided at the discussion.

  • PDF

Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture

  • Oh, Tong-In;Baek, Sang-Min;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권4호
    • /
    • pp.215-221
    • /
    • 2005
  • We describe the development of a prototype multi-channel electrical impedance tomography (EIT) system. The EIT system can be equipped with either a single-ended current source or a balanced current source. Each current source can inject current between any chosen pair of electrodes. In order to reduce the data acquisition time, we implemented multiple digital voltmeters simultaneously acquiring and demodulating voltage signals. Each voltmeter measures a differential voltage between a fixed pair of adjacent electrodes. All voltmeters are configured in a radially symmetric architecture to optimize the routing of wires and minimize cross-talks. To maximize the signal-to-noise ratio, we implemented techniques such as digital waveform generation, Howland current pump circuit with a generalized impedance converter, digital phase-sensitive demodulation, tri-axial cables with both grounded and driven shields, and others. The performance of the EIT system was evaluated in terms of common-mode rejection ratio, signal-to-noise ratio, and reciprocity error. Future design of a more innovative EIT system including battery operation, miniaturization, and wireless techniques is suggested.

INCREASING TREND OF ANGSTROM EXPONENT OVER EAST ASIAN WATERS OBSERVED IN 1998-2005 SEAWIFS DATA SET

  • Fukushima, Hajime;Liping, Li;Takeno, Keisuke
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.57-60
    • /
    • 2007
  • Monthly mean data of ${\AA}ngstr{\ddot{o}}m$ exponent and Aerosol optical thickness (AOT) from Sea-viewing Wide Field-of-view Sensor (SeaWiFS) measurements over the East Asian waters were analyzed. Increasing trend of the satellite-derived ${\AA}ngstr{\ddot{o}}m$ exponent from 1998 to 2004 was found while AOT mean was observed stable during the same period. The trend of ${\AA}ngstr{\ddot{o}}m$ exponent is then interpreted as increase in fraction of small aerosol particles to give quantitative estimates on the variability of aerosols. The mean increase is evaluated to be $4{\sim}5%$ over the 7-year period in terms of the contribution of small particles to the total AOT, or sub-micron fraction (SMF). Possibilities of the observed trend arising from the sensor calibration or algorithm performance are carefully checked, which confirm our belief that this observed trend is rather a real fact than an artifact due to data processing. Another time series of SMF data (2000-2005) estimated from the fine-mode fraction (FMF) of Moderate Resolution Imaging Spectroradiometer (MODIS) supports this observation yet with different calibration system and retrieval algorithms.

  • PDF

미세주사효과를 이용한 배경기반 열영상 불균일 보정 기법 (Scene-based non-uniformity correction for thermal imaging system using microscanning effect)

  • 송인섭;라성웅
    • 대한전자공학회논문지SP
    • /
    • 제37권3호
    • /
    • pp.11-16
    • /
    • 2000
  • 본 논문에서는 미세주사장치를 이용하는 이차원배열 적외선 검출기의 불균일 출력특성 보정을 위한 배경 신호 기반의 디지털방식 실시간 보정 기법을 제안한다 기존의 배경기반 불균일 보정 알고리즘은 영상의 움직임을 전제로 하가 때문에 정지영상에 적용하는 경우 영상이 흐려지면서 사라지는 현상이 나타난다 제안된 기법에서는 미세주사 효과와 변형된 Scribner의 알고리즘을 이용하여 이러한 문제점을 해결하고 영상의 불균일을 실시간으로 보정하였다 컴퓨터 모의실험과 하드웨어 시험을 통해 제안된 기법은 동영상뿐만 아니라 정지영상에서도 뛰어난 성능을 보임을 입증하였다.

  • PDF