• Title/Summary/Keyword: imaging mode

Search Result 333, Processing Time 0.028 seconds

Spectroscopic Detection of Alfvénic Waves in Chromospheric Mottles of a Solar Quiet Region

  • Kwak, Hannah;Chae, Jongchul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.78.2-78.2
    • /
    • 2021
  • We present high resolution spectroscopic observations of transverse magnetohydrodynamic (MHD) waves in mottles located near the solar disk center. Different from previous studies that used transversal displacements of the mottles in the imaging data, we investigated the line-of-sight (LOS) velocity oscillations of the mottles in the spectral data. The observations were carried out by using the Fast Imaging Solar Spectrograph of the 1.6 meter Goode Solar Telescope of Big Bear Solar Observatory. Utilizing the spectral data of the Hα and Ca II 8542 Å lines, we measure the LOS velocity of a quiet region including the mottles and rosettes that correspond to the footpoints of the mottles. Our major findings are as follows: (1) Alfvénic waves are pervasive in the mottles. (2) The dominant period of the waves is 2 to 4 minutes. (3) From the time-distance maps of the three-minute filtered LOS velocity constructed along the mottles, it is revealed that the transverse waves in the mottles are closely related to the longitudinal waves in the rosettes. Our findings support the notion that Alfvénic waves can be generated by mode conversion of the slow magnetoacoustic waves as was shown in sunspot regions by Chae et al. (2021).

  • PDF

Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position (디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과)

  • Kim, Mi-Ja;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-SUk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

3D Measurement System of Wire for Automatic Pull Test of Wire Bonding (Wire bonding 자동 전단력 검사를 위한 wire의 3차원 위치 측정 시스템 개발)

  • Ko, Kuk Won;Kim, Dong Hyun;Lee, Jiyeon;Lee, Sangjoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.12
    • /
    • pp.1130-1135
    • /
    • 2015
  • The bond pull test is the most widely used technique for the evaluation and control of wire bond quality. The wire being tested is pulled upward until the wire or bond to the die or substrate breaks. The inspector test strength of wire by manually and it takes around 3 minutes to perform the test. In this paper, we develop a 3D vision system to measure 3D position of wire. It gives 3D position data of wire to move a hook into wires. The 3D measurement method to use here is a confocal imaging system. The conventional confocal imaging system is a spot scanning method which has a high resolution and good illumination efficiency. However, a conventional confocal systems has a disadvantage to perform XY axis scanning in order to achieve 3D data in given FOV (Field of View) through spot scanning. We propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array to remove XY scan. 2D imaging system can detect 2D location of wire and it can reduce time to measure 3D position of wire. In the experimental results, the proposed system can measure 3D position of wire with reasonable accuracy.

Evaluation on the Usefulness of Ultrasound Image Speckle Reduction Using Total Variation Denoising (TVD) Method in Laplacian Pyramid (라플라시안 피라미드 기반 총변동 잡음제거 기법을 이용한 초음파 영상 스펙클 제거 유용성 평가)

  • Moon, J.H.;Choi, D.H.;Lee, S.Y.;Tae, Ki-Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.140-146
    • /
    • 2016
  • The ultrasound imaging in medical diagnosis has become a popular modality because of its safe, noninvasive, portable, relatively inexpensive, and provides a real-time image formation. However, usefulness of ultrasound imaging is at times limited due to the presence of signal-dependent noise like as speckle. Therefore, noise reduction is very important, as various types of noise generated limits the effectiveness of medical image diagnosis. This paper introduces a speckle noise reduce algorithm using total variation denoising (TVD) in Laplacian pyramid. With this method, speckle is removed by TVD of bandpass ultrasound images in Laplacian pyramid domain. For TVD in each pyramid layer, a ${\lambda}$ is selected by trial-and-error method. The visual comparison of despeckled 'in vivo' ultrasound images from pancreas shows that the proposed method could effectively preserve edges and detailed structures while thoroughly suppressing speckle. For a Simulated B-mode image, contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were obtained like 4.65 dB and 14.11 dB, respectively. The results show that the proposed method can conduct better than some of the existing methods in terms of the CNR and the SNR.

A Reconfigurable Analog Front-end Integrated Circuit for Medical Ultrasound Imaging Systems (초음파 의료 영상 시스템을 위한 재구성 가능한 아날로그 집적회로)

  • Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.66-71
    • /
    • 2014
  • This paper presents an analog front-end integrated circuit (IC) for medical ultrasound imaging systems using standard $0.18-{\mu}m$ CMOS process. The proposed front-end circuit includes the transmit part which consists of 15-V high-voltage pulser operating at 2.6 MHz, and the receive part which consists of switch and a low-power low-noise preamplifier. Depending on the operation mode, the output driver in the transmit pulser can be reconfigured as the switch in the receive path and thus the area of the overall front-end IC is reduced by over 70% in comparison to previous work. The designed single-channel front-end prototype consumes less than $0.045mm^2$ of core area and can be utilized as a key building block in highly-integrated multi-array ultrasound medical imaging systems.

Swimming behavior monitoring of Pacific bluefin tuna (Thunnus orientalis) in the offshore sea cage using the imaging sonar (이미징 소나를 이용한 외해가두리 내 참다랑어의 유영 행동 모니터링)

  • Bo-Kyu HWANG;Myounghee KANG;Min-Son KIM
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.2
    • /
    • pp.125-134
    • /
    • 2023
  • The swimming behavior of pacific bluefin tuna (Thunnus orientalis) in the offshore sea cage of the brass fishing net was observed and analyzed by imaging sonar techniques. The cultured fish spent most of the time swimming a circular path along the circular cage wall and continued to swim only clockwise direction without completely changing the swimming direction during the 23-hour observation time. In addition, changed swimming behaviors were divided into four categories: (a) the behavior of a large group temporarily swimming in the opposite (counter clockwise) direction, (b) the behavior of a small group temporarily swimming in a small circular path, (c) the behavior swimming small circular path in the center of the cage, and (d) the behavior of a large group swimming across the center of the cage. The maximum swimming speed of the cultured fish was from 3.5 to 3.8 TL/s, the mode was from 1.2 to 1.4 TL/s and the swimming speed during the day time was faster than at night time. It was confirmed the cultured fish swam not only on the surface but also near the bottom net of the cage during the day, but swam mainly at the upper part of the cage at night.

The Usefulness of 4D Echocardiographic Modality for Assessing RV Affection in Uncontrolled Hypertensive Patients

  • Rehab M. Hamdy;Shaimaa A Habib;Layla A Mohamed;Ola H. Abd Elaziz
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.4
    • /
    • pp.279-289
    • /
    • 2022
  • BACKGROUND: In many cardiovascular disorders, the contractile performance of the right ventricle (RV) is the primary determinant of prognosis. For evaluating RV volumes and function, 4 dimensional (4D)-echocardiography has become common. This research used 2D and 4D modalities to assess RV contractile performance in hypertensive patients. METHODS: A total of 150 patients with essential hypertension were enrolled in this study, along with 75 age and sex-matched volunteers. Clinical evaluation and echocardiographic examination (including M-mode, tissue Doppler imaging, and 2D speckle tracking) were conducted on all participants. RV volumes, 4D-ejection fraction (EF), 4D-fractional area change (FAC), 4D-tricuspid annular plane systolic excursion (TAPSE), 4D-septal and free wall (FW) strain were all measured using 4D-echocardiography. RESULTS: Hypertensive patients showed 2D-RV systolic and diastolic dysfunction (including TAPSE, 2D-right ventricular global longitudinal strain, RV-myocardial performance index and average E/EaRV) and 4D-RV impairment (including right ventricular EF, FAC, RV strain and TAPSE, right ventricular end-diastolic volume and right ventricular end-systolic volume) compared to the control group. We verified the prevalence of RV systolic dysfunction in hypertension patients using the following parameters: 1) 15% of them had 2D-TAPSE < 17 mm vs. 40% by 4D-TAPSE; 2) 25% of them had 2D-GLS < 19% vs. 42% by 4D-septal strain and 35% by 4D FW strain; 3) 35% of hypertensive patients had 4D-EF < 45%; and finally; 4) 25% of hypertensive patients had 2D-FAC < 35% compared to 45% by 4D-FAC. CONCLUSIONS: The incidence of RV involvement was greater in 4D than in 2D-modality trans-thoracic echocardiography. We speculated that 4D-echocardiography with 4D-strain imaging would be more beneficial for examining RV morphology and function in hypertensive patients than 2D-echocardiography, since 4D-echocardiography could estimate RV volumes and function without making geometric assumptions.

Multi-Channel Data Link Module Design for High Speed Image Data Transmission from Spaceborne SAR (위성 영상 레이다의 고속자료 전송을 위한 멀티 채널 데이터 전송 모듈 설계와 성능 특징)

  • Kwag, Young-Kil
    • Journal of Advanced Navigation Technology
    • /
    • v.5 no.2
    • /
    • pp.149-157
    • /
    • 2001
  • A high speed data link capability is one of the critical factors in determining the performance of the spaceborne SAR system with high resolution. It is due to the strict requirement for the real-time data transmission from a series of massive raw image data of spaceborne SAR to the ground station in a limited time of mission. In this paper, based on the data link model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath.

  • PDF

Applicability of Color Corescanner to the Analysis and Data-base of Drill Cores (시추코어 분석 및 데이터베이스화를 위한 칼라 코어스캐너의 응용)

  • ;Ghodrat Rafat
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.249-256
    • /
    • 2001
  • Optical Color Corescanner firstly developed by DMT-GeoTec, Germany and further upgraded through the Korea-Germany joint project is capable of duplicating the core surfaces. The tool uses a digital CCD line camera. As the core is rotated by an electric motor, the camera scans the uppermost line, everytime with a circumferential increment of up to 0.05mm(20pixels/mm) and hence a complete 360$^{\circ}$ unwrapped image(core image) is produced. This paper illustrated diverse research benefits of such core images from several test sites in our country. All scanned images could be stored as a data-base one and easily used with software facilities \circled1 to evaluate a percental distribution of mineral components or grain size etc. not only for the rock classification but also for e.g. the assessment of building stones, \circled2 to study potential reservoirs as a hydrocarbon indicator using ultraviolet fluorescence reflection from cores, \circled3 to facilitate the qualitative and quantitative analysis of fractures, \circled4 to evaluate the fractures and thin bedded reservoirs using spectral color responses. Based on abundant scanning experiments, it would seem that this imaging work should lead to reflecting the future trend in underground survey toward a more comprehensive understanding of the properties and behaviors of in situ rocks.

  • PDF

Estimation of sound radiation for a flat plate by using BEM and vibration experiment (경계요소 해석과 진동 실험을 이용한 단순 평판의 방사 음향 예측)

  • 김관주;김정태;최승권
    • Journal of KSNVE
    • /
    • v.10 no.5
    • /
    • pp.843-848
    • /
    • 2000
  • BEA(Boundary Element Analysis) based on Kirchhoff-Helmholtz integral equation is widely used in the prediction of sound radiation problems of vibrating structures. Accurate estimation of sound pressure distribution by BEA can be [possible if and only if dynamic behavior of the relating structure was described correctly. Another plausible method of sound radiation phenomena could be the NAH(Nearfield Acoustic Holography) method. NAH also based on the identical governing equation with BEA could be one of the best acoustic imaging schemes but it has disadvantages of the complexity of measurement and of the need of large amount of measuring points. In this paper, modal expansion method is presented for taking accurate dynamic data of the structures efficiently. This method makes use of vibration principle an arbitrary dynamic behavior of the structure is described by the summation of that structures mode shapes which can be calculated by FEA easily and accurately. Sound pressure field from a vibration flat plate is calculated using the combination of vibration signal on that flat plate from experiment, and of the natural mode shapes form FEA. When sound pressure field from vibration signal is calculated the importance of the phase information was emphasized.

  • PDF