• Title/Summary/Keyword: imaging material

Search Result 581, Processing Time 0.027 seconds

The Ability of FDG Uptake Ratio and Glut-1 Expression to Predict Mediastinal Lymph Node Metastasis in Resected Non-small Cell Lung Cancer (절제된 비소세포암에서 FDG 섭취비와 Glut-1 발현 정도를 이용한 종격동 림프선 전이 여부 예측)

  • Cho, Suk-Ki;Lee, Eung-Bae
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.506-512
    • /
    • 2010
  • Background: This study was designed to evaluate the FDG uptake ratio of mediastinal node and primary tumors using integrated PET/CT imaging combined with Glut-1 expression of the primary tumor in order to predict the N2 status more accurately in NSCLC patients. Material and Method: Patients who underwent integrated PET/CT scanning with a detectable mSUV for both primary tumors and mediastinal lymph nodes were eligible for this study. The FDG uptake ratio between the mediastinal node and the primary tumor was calculated. Result: The average mSUV of primary tumors and mediastinal nodes were, respectively, $7.4{\pm}2.2$ and $4.2{\pm}2.2$ in N2-positive patients and $7.6{\pm}3.7$ and $2.8{\pm}6.9$ in N2-negative patients. The mean FDG uptake ratio of mediastinal node to primary tumor were $0.58{\pm}0.23$ for malignant N2 lymph nodes and $0.45{\pm}0.20$ for benign lymph nodes (p<0.05). Models which combined Glut-1 expression with an FDG ratio have better diagnostic power than models that use the FDG uptake ratio alone. Conclusion: In some patients with a previous history of pulmonary tuberculosis or other inflammatory lung diseases, an FDG uptake ratio combined with Glut-1 expression may be useful in diagnosing mediastinal node metastasis more exactly.

Clinical Features of Clonorchiasis (간흡충증의 임상 양상)

  • Kim, Kook-Hyun;Jang, Byung-Ik;Kim, Tae-Nyeun
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.2
    • /
    • pp.171-181
    • /
    • 2006
  • Background: $Clonorchis$ $sinensis$ is an important human parasite that is usually found in the biliary tract. It is widely distributed in East Asia in Taiwan, Japan, China and Korea. About 2 million people are estimated to be infected with $C.$ $sinensis$ in Korea. This study was conducted to evaluate the state of infestation and clinical aspects of $C.$ $sinensis$. Material and Methods: We evaluate 1,063 patients with clonorchiasis retrospectively at Yeungnam University Hospital and Health Promotion Center from January 2001 to December 2003. All patients were diagnosed by a positive stool test for $C.$ $sinensis$ eggs. Clinical features, laboratory data and imaging studies were evaluated. Results: The ratio between affected males and females was 3.6 : 1. The highest infection rate was noted in the 40-60 age groups regardless of sex. The infection rate of $C.$ $sinensis$ among the residents of urban areas was higher than in rural areas. There were 813 (76.5%) patients who were asymptomatic. Common symptoms included right upper abdominal pain in 7.6% and epigastric pain in 7.2%. For the laboratory studies, serum ALP and GGT levels were within normal limits in 85.2% and 56.0% respectively. Peripheral eosinophilia was noted in 66.1% of cases. Of the 83 cases undergoing ERCP, 27 cases (32.5%) showed peripheral dilatation of the intrahepatic duct. Conclusion: This study suggests that $C.$ $sinensis$ infection is still endemic even in rural areas of Korea and that asymptomatic infections are common. Further work should be focused on the early diagnosis and treatment of patients with subclinical infection.

  • PDF

Contrast Enhanced Cerebral MR Venography: Comparison between Arterial and Venous Triggering Methods (조영 증강 자기공명정맥 촬영술에서의 동맥과 정맥 triggering 방법의 비교)

  • Jang, Min-Ji;Choi, Hyun-Seok;Jung, So-Lyung;Ahn, Kook-Jin;Kim, Bum-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2012
  • Purpose : To compare the arterial and venous detection sites of triggering methods in contrast-enhanced-MR-venography (CE-MRV) for the evaluation of intracranial venous system. Materials and Methods: 41 healthy patients underwent CE-MRV with autotriggering at either the cavernous segment of internal carotid artery with an inserted time-delay of 6 seconds (n = 20) or the superior sagittal sinus without any timedelay (n = 21). 0.1 mmol/kg gadolinium-based contrast material ($Magnevist^{(R)}$, Schering, Germany) was intravenously injected by hand injection. A sagittal fast-spoiled-gradient-echo-sequence ranging from one ear to the other was performed (TR/TE5.2/1.5, Matrix $310{\times}310$, 124 sections in the 15-cm-thick volume). 17 predefined venous structures were evaluated on all venograms by two neuroradiologists and defined as completely visible, partially visible, or none visible. Results: The rate of completely visible structures were 272 out of 323 (84%) in the arterial triggering CE-MRV and 310 out of 340 (91%) in the venous triggering CE-MRV. The venous triggering CE-MRV demonstrated an overall superior visualization of the cerebral veins than the arterial triggering CE-MRV (Fisher exact test, p < 0.006). Conclusion: CE-MRV using venous autotriggering method provides higher-quality images of the intracranial venous structures compared to that of arterial.

Synthesis of Substrates for Gene Therapy Monitoring of HSV1-TK System (유전자 영상용 HSV1-TK 기질의 합성)

  • Choi, Tae-Hyun;Ahn, Soon-Hyuk;Choi, Chang-Woon;Lim, Sang-Moo;Awh, Ok-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.2
    • /
    • pp.102-109
    • /
    • 2002
  • Purpose : In gene therapy, tumor cells expressing the herpes simplex virus thymidine kinase are sensitive to prodrugs. Potential prodrugs IVDU and IVFRU were synthesized and radiolabeled with radioiodine for noninvasive imaging of herpes simplex virus type 1 gene expression. Material and Methods : 5-(2-trimethysilyl) vinyl-2'-deoxyuridine and 5-(2-trimethylsilyl)vinyl-2'-fluoro-2'-deoxyuridine, precursors of 5-(2--iodo)viny l-2'-deoxy uridine(IVDU) and 5-(2-iodo)-2'-vinyl-2'-deoxy-2'-fluororibofuranosyl uracil(IVFRU), were synthesized from reaction of trans-1-trimethylsillyl-2-tri-n-butylstannylethylene with 5-iodo-2'-deoxyuridine and 5-iodo-2'-fluoro-2'-deoxyuridine, respectively, on the condition of Pd catalyst. These precursors were separated from reaction mixture by silica gel column chromatography method. Each precursor was radioiodinated with radioiodine by mixing with ICI oxidizing agent. These radioiodinated compounds were purified with HPLC. Radiohalogen exchange has been shown to be effective for the synthesis of products with lower specific activity. Similarly, carrier-added and high specific activity products have been isolated in respectable radiochemical yields using ICI method. Results : Synthetic yield of precursors, IVDU and IVFRU were 43% and 18%, respectively. Radiochemical purity of both compunds was over 98%. Conclusion : We synthesized precursors of IVDU and IVFRU for monitoring of HSV1-tk gene expression. Radiotracers were radioiodinated with high radiolabeling yield by ICI method.

Neuronal Dysfunction in Patients with Chronic Alcoholism Evaluated by In Vivo $^1H$ Magnetic Resonance Spectroscopy (알콜중독환자의 신경기능 장애: 생체 양성자 자기공명분광 연구)

  • Bo-Young Choe;Euy-Neyng Kim;Chang-Wook Lee;In-Ho Baik;Kwang-Soo Lee;Byung-Chul Son;Heung-Jae Chun;Hyoung-Koo Lee;Tae-Suk Suh
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.94-99
    • /
    • 2000
  • Purpose : With the use of localized, water-suppressed in vivo $^1H$ magnetic resonance spectroscopy (MRS), we evaluated the proton metabolic alterations in patients with chronic alcoholism and healthy normal controls. Material and Methods : Patients with chronic alcoholism (N = 10) and normal control subjects (N = 10) underwent MRS examinations using a stimulated echo acquisition mode (STEAM) pulse sequence with $2{\times}2{\times}2{\;}\textrm{cm}^3$ volume of interest (VOI) in the left cerebellum and basal ganglia. Proton metabolite ratios relative to creative (Cr) were obtained using a Marquart algorithm. Results : The specific feature in patients with chronic alcoholism was a significant decrease of N-acetylaspartate (NAA)/Cr ratio in the left cerebellum, compared with normal controls. No clear correlation of other metabolite ratios such as choline (Cho)/Cr and inositols (Ins)/Cr was established. Conclusion : Our preliminary study suggests that the reduction of NAA/Cr ratio may indicate neuronal loss in patients with chronic alcoholism. Thus, in vivo 1H MRS may be a useful modality in the clinical evaluation of patients with chronic alcoholism based on the proton metabolite ratios.

  • PDF

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF

Catalytic Reduction of Nitric Oxide by Carbon Monoxide over Perovskite-Type Oxide (페롭스카이트형 산화물에서 일산화탄소에 의한 질소산화물의 환원반응)

  • Moon, Haeng-Chul;Sun, Chang-Bong;Lee, Gun-Dae;Ahn, Byuong-Hyun;Lim, Kwon-Taek;Hong, Seong-Soo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.407-414
    • /
    • 1999
  • We have studied the reduction of NO by CO over perovskite-type oxides prepared by malic and method. The catalysts were modified to enhance the activity by substitution of metal into A or B site of perovskite oxides. In the $LaCoO_3$ type catalyst, the partial substitution of Sr into A site enhanced the catalytic activity on the conversion of NO at less than $350^{\circ}C$. In the $La_{0.6}Sr_{0.4}Co_{1-x}Fe_xO_3$ catalyst, the partial substitution of Fe or Mn into B site enhanced the conversion of NO, but excess amount of Fe decreased the conversion of NO. In addition, $La_{0.6}Sr_{0.4}Co_{0.8}Fe_{0.2}O_3$ mixed with $SnO_2$ or $MnO_2$ showed the synergy effect on the reduction of NO. The introduction of water into reactants feed decreased the catalytic activity but the deactivation was shown to be reversible. The introduction of $SO_2$ into reactants feed also decreased the catalytic activity.

  • PDF

Effect of Manganese Content on the Magnetic Susceptibility of Ferrous-Manganese Alloys: Correlation between Microstructure on X-Ray Diffraction and Size of the Low-Intensity Area on MRI

  • Youn, Sung Won;Kim, Moon Jung;Yi, Seounghoon;Ahn, Hyun Jin;Park, Kwan Kyu;Lee, Jongmin;Lee, Young-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.76-87
    • /
    • 2015
  • Purpose: There is an ongoing search for a stent material that produces a reduced susceptibility artifact. This study evaluated the effect of manganese (Mn) content on the MRI susceptibility artifact of ferrous-manganese (Fe-Mn) alloys, and investigated the correlation between MRI findings and measurements of Fe-Mn microstructure on X-ray diffraction (XRD). Materials and Methods: Fe-Mn binary alloys were prepared with Mn contents varying from 10% to 35% by weight (i.e., 10%, 15%, 20%, 25%, 30%, and 35%; designated as Fe-10Mn, Fe-15Mn, Fe-20Mn, Fe-25Mn, Fe-30Mn, and Fe-35Mn, respectively), and their microstructure was evaluated using XRD. Three-dimensional spoiled gradient echo sequences of cylindrical specimens were obtained in parallel and perpendicular to the static magnetic field (B0). In addition, T1-weighted spin echo, T2-weighted fast spin echo, and $T2^*$weighted gradient echo images were obtained. The size of the low-intensity area on MRI was measured for each of the Fe-Mn binary alloys prepared. Results: Three phases of ${\alpha}^{\prime}$-martensite, ${\gamma}$-austenite, and ${\varepsilon}$-martensite were seen on XRD, and their composition changed from ${\alpha}^{\prime}$-martensite to ${\gamma}$-austenite and/or ${\varepsilon}$-martensite, with increasing Mn content. The Fe-10Mn and Fe-15Mn specimens comprised ${\alpha}^{\prime}$-martensite, the Fe-20Mn and Fe-25Mn specimens comprised ${\gamma}+{\varepsilon}$ phases, and the Fe-30Mn and Fe-35Mn specimens exhibited a single ${\gamma}$ phase. The size of the low-intensity areas of Fe-Mn on MRI decreased relative to its microstructure on XRD with increasing Mn content. Conclusion: Based on these findings, proper conditioning of the Mn content in Fe-Mn alloys will improve its visibility on MR angiography, and a Mn content of more than 25% is recommended to reduce the magnetic susceptibility artifacts on MRI. A reduced artifact of Fe-Mn alloys on MRI is closely related to the paramagnetic constitution of ${\gamma}$-austenite and/or ${\varepsilon}$-martensite.

Soft-template Synthesis of Magnetically Separable Mesoporous Carbon (자성에 의해 분리 가능한 메조포러스 카본의 소프트 주형 합성)

  • Park, Sung Soo;Ha, Chang-Sik
    • Journal of Adhesion and Interface
    • /
    • v.18 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • In this study, we synthesized mesoporous carbon (Carbonized Ni-FDU-15) containing nanoporous structures and magnetic nanoparticles. Carbonized Ni-FDU-15 was synthesized via evaporation-induced self-assembly (EISA) and direct carbonization by using a triblock copolymer (F127) as a structure-directing agent, a resol precursor as a carbon-pore wall forming material, and nickel (II) nitrate as a metal ion source. The mesoporous carbon has a well-ordered two-dimensional hexagonal structure. Meanwhile, nickel (Ni) metal and nickel oxide (NiO) were produced in the magnetic nanoparticles in the pore wall. The size of the nanoparticles was about 37 nm. The surface area, pore size and pore volume of Carbonized Ni-FDU-15 were $558m^2g^{-1}$, $22.5{\AA}$ and $0.5cm^3g^{-1}$, respectively. Carbonized Ni-FDU-15 was found to move in the direction of magnetic force when magnetic force was externally applied. The magnetic nanoparticle-bearing mesoporous carbons are expected to have high applicability in a wide variety of applications such as adsorption/separation, magnetic storage media, ferrofluid, magnetic resonance imaging (MRI) and drug targeting, etc.

CdZnTe Detector for Computed Tomography based on Weighting Potential (가중 퍼텐셜에 기초한 CT용 CdZnTe 소자 설계)

  • Lim, Hyunjong;Park, Chansun;Kim, Jungsu;Kim, Jungmin;Choi, Jonghak;Kim, KiHyun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Room-temperature operating CdZnTe(CZT) material is an innovative radiation detector which could reduce the patient dose to one-tenth level of conventional CT (Computed Tomography) and mammography system. The pixel and pixel pitch in the imaging device determine the conversion efficiency of incident X-or gamma-ray and the cross-talk of signal, that is, image quality of detector system. The weighting potential is the virtual potential determined by the position and geometry of electrode. The weighting potential obtained by computer-based simulation in solving Poisson equation with proper boundaries condition. The pixel was optimized by considering the CIE (charge induced efficiency) and the signal cross-talk in CT detector system. The pixel pitch was 1-mm and the detector thickness was 2-mm in the simulation. The optimized pixel size and inter-pixel distance for maximizing the CIE and minimizing the signal cross-talk is about $750{\mu}m$ and $125{\mu}m$, respectively.