• Title/Summary/Keyword: imaging material

Search Result 578, Processing Time 0.033 seconds

Measurement of the Complex Permittivies of Various Dielectrics Using an Open-Ended Coaxial Probe (개방단말 동축선 프로브를 이용한 다양한 유전체의 복소 유전율 측정)

  • Shin, Hyun;Hyun, Seung-Yeup;Kim, Sang-Wook;Kim, Se-Yun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.7
    • /
    • pp.22-27
    • /
    • 2001
  • In this paper, the complex permittivity of various dielectrics such as powder(sugar and flour) and solid(teflon and acrvl) are measured by using an open ended coaxial-line probe, which is self designed and manufactured, The probe is connected to a vector network analyzer(VNA) through a coaxial cable, The end of the cable is corrected by using an OSL(open, short, and load) calibration kit, The phase difference, which is produced by inserting the probe at the end of the line. is compensated by using the numerically calculated reflection coefficient of distilled water, The complex permittivity is reconstructed by inserting the measured reflection coefficient, which is produced at the interface between the probe and measuring material, into ,an virtual conical cable conversion model. Over a wide frequency range from 30 MHz to 3 GHz, the measured complex permittivitis of various powder and solid using the our method are compared with the results, which are measured by using an transmission-line method of the Korea Research Institute of Standards and Science(KRISS).

  • PDF

Solitary Fibrous Tumor of the Ischiorectal Fossa : CT and MRI Findings (좌골직장와에서 기원하는 고립섬유종양: CT, MR 영상소견의 증례 보고)

  • Kim, Ki-Hwan;Cha, Sang-Hoon;Yeom, Suk-Keu;Lee, Seung-Hwa;Chung, Hwan-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.72-76
    • /
    • 2011
  • Solitary fibrous tumor (SFT) is a rare neoplasm, which is usually presented as a pleural based mass, but can also occur in unusual locations based on its mesenchymal origin. However, the radiologic features of SFT occurred in the ischiorectal fossa have been rarely reported. In this case, we describe the MRI findings in a case of a SFT involving the ischiorectal fossa of a 36-year-old man. The tumor appeared as homogeneous iso-signal intensity relative to the adjacent muscle on T1 weighted images, a mixed high signal intensity on the T2 weighted images, and heterogeneous enhancement following the administration of the contrast material.

Elastic Imaging of Material Surface by Ultrasonic Atomic Force Microscopy (초음파 원자 현미경을 이용한 재료 표면의 탄성 이미지화)

  • Kim, C.S.;Park, Tae-Sung;Park, It-Keun;Lee, Seung-Seok;Lee, C.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.293-298
    • /
    • 2009
  • The ultrasonic atomic force microscope(UAFM) has been developed in order to enhance the characterization technology for nano-scale surface combining ultrasonic property to atomic force microscope. This UAFM technique enables elasticity imaging due to the physical properties on the heterogeneous surface in addition to the novel topography of surface height in the nano-surface layer. In this study, the prototype UAFM system was constructed and applied to several materials, silicon deposited wafer, spherodized cold heading steel, and carbon fiber reinforced plastic specimen. Clear elastic contrast was successfully obtained using this developed prototype UAFM.

Luminous Characteristics of Bridge's Nightscape across the Han River (조명물리량 측면에서 본 교량의 야간경관 평가)

  • Hwang, Tae-Yon;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.7-18
    • /
    • 2006
  • This study aims to analyze the illumination effects of bridges across the Han River. For the purpose, 8 bridges were selected. Field survey and measurements were performed, and the physical values such as luminance, color temperature and chromaticity were measured by Radiant Imaging Prometric 1400 Color. The results of the study are as follows; (1) Metal halide lamp, sodium lamp and LED(Light Emitting Diode) of various colors, are used in illuminating the bridges and create color contrasts and color changing by color filters. (2) Luminance contrast of the illuminated bridges affects 'modeling' and 'spare sense' of bridges, and it might improve people's preference and impression. (3) Color temperature of the illuminated bridges is influenced by 'color of bridge', 'material of bridge' and, 'color temperature and color of light sources'. (4) 'Structure of bridges' and 'luminaires' influence on the physical feature of the bridges. Especially, illumination of the bridges shows resemblant patterns by 'structure of bridges'.

Study on Electrical Properties of X-ray Sensor Based on CsI:Na-Selenium Film

  • Park Ji-Koon;Kang Sang-Sik;Lee Dong-Gil;Choi Jang-Yong;Kim Jae-Hyung;Nam Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.3
    • /
    • pp.10-14
    • /
    • 2003
  • In this paper, we have introduced the x-ray detector built with a CsI:Na scintillation layer deposited on amorphous selenium. To determine the thickness of the CsI:Na layer, we have estimated the transmission spectra and the absorption of continuous x-rays in diagnostic range by using computer simulation (MCNP 4C). A x-ray detector with 65 ${\mu}m$-CsI:Na/30 ${\mu}m$-Se layer has been fabricated by a thermal evaporation technique. SEM and PL measurements have been performed. The dark current and x-ray sensitivity of the fabricated detector has been compared with that of the conventional a-Se detector with 100 ${\mu}m$ thickness. Experimental results show that both detectors exhibit a similar dark current, which was of a low value below $400 pA/cm^2$ at 10 V/${\mu}m$. However, the CsI:Na-Se detector indicates high x-ray sensitivity, roughly 1.3 times that of a conventional a-Se detector. Furthermore, a CsI:Na-Se detector with an aluminium reflective layer shows a 1.8 times higher x-ray sensitivity than an a-Se detector. The hybrid type detector proposed in this work exhibits a low dark current and high x-ray sensitivity, and, in particular, excellent linearity to the x-ray exposure dose.

Ultrahigh-Resolution Spectral Domain Optical Coherence Tomography Based on a Linear-Wavenumber Spectrometer

  • Lee, Sang-Won;Kang, Heesung;Park, Joo Hyun;Lee, Tae Geol;Lee, Eun Seong;Lee, Jae Yong
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2015
  • In this study we demonstrate ultrahigh-resolution spectral domain optical coherence tomography (UHR SD-OCT) with a linear-wavenumber (k) spectrometer, to accelerate signal processing and to display two-dimensional (2-D) images in real time. First, we performed a numerical simulation to find the optimal parameters for the linear-k spectrometer to achieve ultrahigh axial resolution, such as the number of grooves in a grating, the material for a dispersive prism, and the rotational angle between the grating and the dispersive prism. We found that a grating with 1200 grooves and an F2 equilateral prism at a rotational angle of $26.07^{\circ}$, in combination with a lens of focal length 85.1 mm, are suitable for UHR SD-OCT with the imaging depth range (limited by spectrometer resolution) set at 2.0 mm. As guided by the simulation results, we constructed the linear-k spectrometer needed to implement a UHR SD-OCT. The actual imaging depth range was measured to be approximately 2.1 mm, and axial resolution of $3.8{\mu}m$ in air was achieved, corresponding to $2.8{\mu}m$ in tissue (n = 1.35). The sensitivity was -91 dB with -10 dB roll-off at 1.5 mm depth. We demonstrated a 128.2 fps acquisition rate for OCT images with 800 lines/frame, by taking advantage of NVIDIA's compute unified device architecture (CUDA) technology, which allowed for real-time signal processing compatible with the speed of the spectrometer's data acquisition.

Advanced Nanoscale Characterization of Cement Based Materials Using X-Ray Synchrotron Radiation: A Review

  • Chae, Sejung R.;Moon, Juhyuk;Yoon, Seyoon;Bae, Sungchul;Levitz, Pierre;Winarski, Robert;Monteiro, Paulo J.M.
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.2
    • /
    • pp.95-110
    • /
    • 2013
  • We report various synchrotron radiation laboratory based techniques used to characterize cement based materials in nanometer scale. High resolution X-ray transmission imaging combined with a rotational axis allows for rendering of samples in three dimensions revealing volumetric details. Scanning transmission X-ray microscope combines high spatial resolution imaging with high spectral resolution of the incident beam to reveal X-ray absorption near edge structure variations in the material nanostructure. Microdiffraction scans the surface of a sample to map its high order reflection or crystallographic variations with a micron-sized incident beam. High pressure X-ray diffraction measures compressibility of pure phase materials. Unique results of studies using the above tools are discussed-a study of pores, connectivity, and morphology of a 2,000 year old concrete using nanotomography; detection of localized and varying silicate chain depolymerization in Al-substituted tobermorite, and quantification of monosulfate distribution in tricalcium aluminate hydration using scanning transmission X-ray microscopy; detection and mapping of hydration products in high volume fly ash paste using microdiffraction; and determination of mechanical properties of various AFm phases using high pressure X-ray diffraction.

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

Determination of Impact Source Location Using a Single Transducer and Time Reversal Technique (단일센서와 시간역전법을 이용한 판에서의 충격위치 결정에 관한 연구)

  • Jeong, Hyun-Jo;Cho, Sung-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • A structural health monitoring technique for locating impact position in a plate structure is presented in this paper. The method employs a single sensor and spatial focusing of time reversal (TR) acoustics. We first examine the TR focusing effect at the impact position and its surroundings through simulation and experiment. The imaging results of impact points show that the impact source location can be accurately estimated in any position of the plate. Compared to existing techniques for locating impact or acoustic emission source, the proposed method has the benefits of using a single sensor and not requiring material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in other ultrasonic testings of plate-like structures.

Three Cases of Extrahepatic Bile Duct Disorder: Diagnostic Imaging in Perspective (진단 영상을 위주로한 간외 담도계 질환 3례)

  • Lim Chang-yun;Jeong Yu-cheol;Oh Sun-kyoung;Jung Joo-hyun;Kim So-hee;Kim Nam-hyang;Seo Kyeong-won;Hwang Cheol-yong;Byeon Ye-eun;Kweon Oh-kyeong;Choi Min-cheol;Yoon Junghee
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.412-416
    • /
    • 2005
  • Three cases of extrahepatic bile duct disorder were presented. Two cases, a dog and a cat, were related to the obstruction of the extrhepatic bile duct, the other dog was affected with the gall bladder rupture. The clinical signs included anorexia, abdominal distension and vomiting. The laboratory test represented increased hepatic enzymes. On the radiography, hepatomegaly was seen in the obstructive cases, and ascites could be seen in the ruptured case. On the Ultrasonography, dilated gall bladder and extrahepatic bile duct were found in the obstructive cases, and there were ascites, indistinct gall bladder wall, dilation of gall bladder and extrabiliary tract, increased mesenteric echogenicity in the ruptured case. All presented were taken medication, surgical foreign material removal, or cholecystectomy showed complete recovery.