• 제목/요약/키워드: imaging material

검색결과 578건 처리시간 0.03초

Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

  • Dantas, Raquel Venancio Fernandes;Sarmento, Hugo Ramalho;Duarte, Rosangela Marques;Meireles Monte Raso, Sonia Saeger;de Andrade, Ana Karina Maciel;Dos Anjos-Pontual, Maria Luiza
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Materials and Methods: Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. Results: The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. Conclusion: The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

위상잠금 열화상기법을 이용한 복합재 튜브 충격 손상 결함 측정 (Defect Detection of Impacted Composite Tubes by Lock-in Photo-Infrared Thermography Technique)

  • 김경석;전소영;정현철
    • 비파괴검사학회지
    • /
    • 제31권2호
    • /
    • pp.139-143
    • /
    • 2011
  • 충격에 의한 복합재 튜브의 내부 박리 현상은 항공 우주 및 자동차 산업 등에서 흔히 발생되어져 왔다. 이러한 복합재 구조물의 안전성을 평가하기 위해서는 적외선열화상기법(IRT)과 같은 복합재 구조물의 내부 결함을 검출할 수 있는 비파피검사가 필요하다. 적외선 열화상 이미지 패턴 분석에 의해서 내부 결함이 발생한 복합재 튜브의 내 외부 결함 부위를 확인할 수 있다. 본 연구에서는 적외선열화상기법을 이용하여 충격 하중에 따른 복합재 튜브 표면에서 방출하는 적외선 에너지를 감지하여 열 분배로부터 복합재 튜브의 내부 결함을 검출하는 연구를 수행하였다.

혼합형 구조를 적용한 $HgI_2$ 기반의 방사선 센서 제작 및 특성 (Fabrication and characteristics of Hybrid-type radiation detector using $HgI_2$)

  • 장기원;강현규;이규홍;김소영;박지군;최흥국;남상희;임정기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.460-463
    • /
    • 2004
  • 본 논문은 고에너지 방사선 검출을 위한 흔합형 구조의 방사선 센서를 제작, 반응 특성을 평가하였다. 먼저, 스크린 인쇄법을 이용하여 형광체 필름을 제작하였으며, 발광스펙트럼(PL, Photoluminescence) 및 잔광 시간(decay time) 측정을 통하여 형광체의 발광 특성을 조사하였다. 제작된 혼합구조의 방사선 센서는 $2{\mu}m$ 두께의 $HgI_2$$150{\mu}m$ 두께의 형광체 필름으로 제작되었으며, 면적은 $2\;cm\;{\times}\;2\;cm$이다. 방사선에 대한 전기적 검출 신호의 특성을 조사하기 위해 인가전압에 따른 암전류 및 방사선민감도, 선량에 따른 검출신호를 측정하였다. 측정결과, 제작된 $HgI_2$ 필름은 방사선에 의해 형광체에서 방출된 가시광 파장을 잘 흡수하였으며, 진단영역의 저에너지 방사선에 의해 직접 전기적 신호를 발생시켜 높은 방사선 민감도를 보였다. 뿐만 아니라, 인가전압에 대해 $10\;pA/mm^2$이하의 낮은 암전류를 가졌으며, 넓은 조사선량에서 우수한 선형성을 보였다.

  • PDF

Dynamic Susceptibility Contrast Magnetic Resonance Images를 이용한 뇌혈류량 지도 구성 (Cerebral Blood Volume Mapping from Dynamic Susceptibility Contrast Magnetic Resonance Images)

  • 김수정;이선규;김광기;김종효;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.281-282
    • /
    • 1998
  • Recently, there has been growing interest in the assessment of physiological parameters on brain perfusion that provide more information than pure morphologic diagnosis. Quantification of parameters that characterize cerebral micro-circulation with magnetic resonance imaging is of great relevance for clinical application. We determine the local tissue concentration by exponential relationship between the relative signal reduction S(t)/$S_0$ and local tissue concentration of contrast material $C_m(t)$ in dynamic susceptibility contrast enhanced MR imaging. And then we made relative regional blood volume map by calculating the area under the measured concentration-time curves $C_m(t)$ during first pass of paramagnetic contrast material as a preliminary step for perfusion map. These images make it possible to compare the rCBV in different brain regions in one individual at a time. We have it in contemplation to obtain arterial and brain signal time curves simultaneously to make absolute rCBV and perfusion (rCBF) map. These maps may provide the method of comparative investigations of different patients having strong variation in AIF.

  • PDF

Arsenic의 첨가량에 따른 방사선 검출센서 (a-Se)의 전기적 특성 비교 (The Comparison of Electric Characteristics of Radiation Detective Sensor(a-Se) with changing composition ratio of Arsenic)

  • 석대우;강상식;이동길;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.391-394
    • /
    • 2002
  • There has recently been much interest and research in developing digital x-ray systems based on using amorphous selenium(a-Se) photoconductors as the image receptor. The amorphous selenium layer that is currently being studied for use as an x-ray photoconductor is not pure a-Se but rather amorphous selenium alloyed with arsenic. We fabricated samples using the selenium and arsenic alloy with various concentrations of the arsenic. In this work, x-ray photoconductor using amorphous selenium alloyed with arsenic were fabricated with different concentrations of the arsenic (0.1 wt.%, 0.3wt.%, 0.5wt.%, 1wt.%, 1.5wt.%, 3wt.%, 5wt.%). The seven kind of samples was fabricated with a-Se alloyed with arsenic through vacuum thermal evaporation. We also investigate the arsenic concentration dependence on the device performance in radiation detector. The electric characteristics of radiation detector devices with changing additive ratio of the arsenic is performed by measuring the x-ray induced photocurrent and integrating it over time to find the total charge. The thickness of a-Se is $100{\mu}m$. Bias voltages $3V/{\mu}m$, $6V/{\mu}m$$9V/{\mu}m$ are applied at the samples. As results, the net charge of a-Se 0.3% As sample is $526.0pC/mR/cm^2$ at $9V/{\mu}m$ bias. The net charge is decreased as with the increasing additive ratio of arsenic.

  • PDF

콘빔형 전산화단층영상에서 HU에 의한 두경부 팬텀 경조직의 밀도 측정 (Measurement of hard tissue density of head phantom based on the HU by using CBCT)

  • 김문선;김재덕;강동완
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.115-120
    • /
    • 2009
  • Purpose : The purpose of this study was to determine a conversion coefficient for Hounsfield Units(HU) to material density ($g\;cm^{-3}$) obtained from cone-beam computed tomography ($CBMercuRay^{TM}$) data and to measure the hard tissue density based on the Hounsfield scale on dental head phantom. Materials and Methods : CT Scanner Phantom (AAPM) equipped with CT Number Insert consists of five cylindrical pins of materials with different densities and teflon ring was scanned by using the $CBMercuRay^{TM}$ (Hitachi, Tokyo, Japan) volume scanner. The raw data were converted into DICOM format and the HU of different areas of CT number insert measured by using $CBWorks^{TM}$. Linear regression analysis and Student t-test were performed statistically. Results : There was no significant difference (P > 0.54) between real densities and measured densities. A linear regression was performed using the density, $\rho$($g\;cm^{-3}$), as the dependent variable in terms of the HU (H). The regression equation obtained was $\rho=0.00072H-0.01588$ with an $R^2$ value of 0.9968. Density values based on the Hounsfield scale was $1697.1{\pm}24.9\;HU$ in cortical bone, $526.5{\pm}44.4\;HU$ in trabecular bone, $2639.1{\pm}48.7\;HU$ in enamel, $1246.1{\pm}39.4\;HU$ in dentin of dental head phantom. Conclusion : CBCT provides an effective option for determination of material density expressed as Hounsfield Units.

  • PDF

X선 영상 검출기 적용을 위한 $Gd_2O_3$:Eu 필름의 X선 발광 특성에 관한 연구 (Optical characteristics of $Gd_2O_3$:Eu phosphor film for x-ray imaging detector)

  • 김소영;강상식;차병열;손대웅;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.344-344
    • /
    • 2007
  • 본 연구에서는 X선 영상 검출기로의 적용을 위하여 $Gd_2O_3$:Eu 형광체 필름을 제작하여 X선에 대한 발광 특성을 분석하였다. $Gd_2O_3$:Eu는 저온 액상법을 이용하여 분말 형태로 제조한 후 Particle-in-binder (PIB)으로 필름 형태로 제작한 후, 도핑된 Europium(Eu)의 농도와 소결 온도에 따른 X선에 대한 발광 특성을 분석하였다. Photolumimescence (PL) spectrum에서 611nm에서 가장 높은 발광 효율을 나타내었으며, 입자의 크기가 줄어듦에 따라 610nm에서 새로운 peak가 형성 되었다. 또한 Eu의 농도에 따라서 발광 강도의 차이가 관찰되었는데, 5wt%의 도핑 농도에서 가장 높은 발광 효율을 나타냈으며, 도핑 농도에 매우 의존적인 결과를 나타냈다. 소결 온도에 따른 발광 특성 분석에서, $500^{\circ}C$에서 소결하였을 때는 623nm에서 강한 peak를 나타내는 단사정계상의 발광 peak는 거의 관찰되지 않았으나 소결 온도가 $700^{\circ}C$$900^{\circ}C$에서는 peak가 확인되었다. 이를 통해 $Gd_2O_3$ 모체가 대부분 입방 대칭 구조를 가지는 $Gd_2O_3$:Eu가 합성되었음을 확인할 수 있었다. 또한 소결 온도에 따른 발광 강도를 분석한 결과 $900^{\circ}C$에서 소결하였을 때 가장 높은 발광 강도를 나타냈다. Luminescent decay time 측정 결과에서 도핑된 Eu의 농도가 커질수록 Luminescent decay time이 짧아짐을 확인할 수 있었다.

  • PDF

와전류 탐상기법을 이용한 무릎보조기용 섬유강화 폴리머의 이방특성 분석 (Analysis of Anisotropic Characteristic in Fiber Reinforced Polymer for the Knee Brace Using the Eddy Current Inspection)

  • 김철웅;박천웅;신용훈;서해용;이호상
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1533-1538
    • /
    • 2008
  • The development of new material systems like Carbon Fiber Reinforced Polymer (CFRP) places ever higher demands on the techniques for non-destructive material characterisation. Image-producing eddy current methods also need to satisfy these demands. Eddy-current imaging of FRP is based on the anisotropic electrical properties of the material investigated. Significant differences in conductivity between carbon fibres, polymer matrix and integrated functional components can be found. The availability of high-resolution sensors enables access to the local distribution of the electromagnetic properties. The static and dynamic procedures for isolating influential characteristics, already in use in eddy-current technology, can now be supplemented by topographical images. The precondition for a successful implementation of the eddy-current procedure is a deeper understanding of the image-generating process which allows correct interpretation of the images obtained.

  • PDF

Transport Properties of Conversion Materials for Digital Radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권6호
    • /
    • pp.250-254
    • /
    • 2007
  • Applying the moving photo-carrier grating(MPG) technique and time-of-flight(TOF) measurements, we studied the transport properties of stabilized amorphous selenium typical of the material used in direct conversion X-ray imaging devices. For MPG measurement, we obtained electron and hole mobility and the recombination lifetime of $\alpha-Se$ films with arsenic(As) additions. We found an apparent increase in hole drift mobility and recombination lifetime, especially when 0.3 % As was added into $\alpha-Se$ film, whereas electron mobility decreased with the addition of As due to the defect density. For TOF measurement, a laser beam with pulse duration of 5 ns and wavelength of 350 nm was illuminated on the surface of $\alpha-Se$ with a thickness of 400 ${\mu}m$. The measured hole and electron transit times were about 8.73 ${\mu}s$ and 229.17 ${\mu}s$, respectively.

New polymeric host material for efficient organic electro phosphorescent devices

  • Jung, Choong-Hwa;Park, Moo-Jin;Eom, Jae-Hoon;Shim, Hong-Ku;Lee, Seong-Taek;Yang, Nam-Choul;Liand, Duan;Suh, Min-Chul;Chin, Byung-Doo;Hwang, Do-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.843-845
    • /
    • 2009
  • A polymeric host for triplet emitters composed of N-alkylcarbazole and tetramethylbenzene units was successfully synthesized. Efficient energy transfer was observed between this polymeric host and green phosphorescent dyes. The device fabricated using 5 wt% green 1 in the polymeric host as the emitting layer showed the best performance. Thin films of this host-guest system, exhibiting clear stripe patterns could be prepared through the LITI process. The patterned films were then used to fabricate electrophosphorescent devices, which show performance characteristics similar to those of spin-coated devices. The new host material is a good candidate to be used in polymer-based full-color electrophosphorescent light-emitting displays.

  • PDF