• Title/Summary/Keyword: imaging device

Search Result 616, Processing Time 0.026 seconds

Dosimetric Effects of Intrafractional Organ Motion in Field-in-Field Technique for Whole-Breast Irradiation

  • Hong, Chae-Seon;Ju, Sang Gyu;Choi, Doo Ho;Han, Youngyih;Huh, Seung Jae;Park, Won;Ahn, Yong Chan;Kim, Jin Sung;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.30 no.3
    • /
    • pp.65-73
    • /
    • 2019
  • Purpose: We evaluated the motion-induced dosimetric effects on the field-in-field (FIF) technique for whole-breast irradiation (WBI) using actual patient organ motion data obtained from cine electronic portal imaging device (cine EPID) images during treatment. Materials and Methods: Ten breast cancer patients who received WBI after breast-conserving surgery were selected. The static FIF (SFIF) plan involved the application of two parallel opposing tangential and boost FIFs. To obtain the amplitude of the internal organ motion during treatment, cine EPID images were acquired five times for each patient. The outside contour of the breast (OCB) and chest wall (CW) contour were tracked using in-house motion analysis software. Intrafractional organ motion was analyzed. The dynamic FIF (DFIF) reflecting intrafractional organ motion incorporated into the SFIF plan was calculated and compared with the SFIF in terms of the dose homogeneity index (DHI90/10) for the target and V20 for the ipsilateral lung. Results: The average motion amplitudes along the X and Y directions were 1.84±1.09 mm and 0.69±0.50 mm for OCB and 1.88±1.07 mm and 1.66±1.49 mm for CW, respectively. The maximum motion amplitudes along the X and Y directions were 5.53 and 2.08 mm for OCB and 5.22 and 6.79 mm for CW, respectively. Significant differences in DHI90/10 values were observed between SFIF and DFIF (0.94 vs 0.95, P<0.05) in statistical analysis. The average V20 for the lung in the DFIF was slightly higher than that of the SFIF in statistical analysis (19.21 vs 19.00, P<0.05). Conclusion: Our findings indicate that the FIF technique can form a safe and effective treatment method for WBI. Regular monitoring using cine EPID images can be effective in reducing motion-induced dosimetric errors.

PSNR Evaluation of P Company DSA System between Server Display Monitor and Client Display Monitor (P사 DSA 시스템의 Server Display Monitor와 Client Display Monitor의 PSNR 평가)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • PACS is needed medical imaging with large-capacity storage device. Slower transmission degrades the performance of the PACS. Thus, the image read by the reading of the long-term stored image without compromising the quality of the video, which does not affect future readings in the range will be compressed and stored. Compression and video storage, and video transport Noise generated during storage and transmission of medical images and the resulting loss of information that occurs when the monitor output from many problems. The study estimates server display monitor and client display monitor of philips DSA system, and suggests that the evaluation and improvement about PSNR, process from server display signal obtaining to client display monitor. P company DSA is used in the test. Two monitors that are $1280{\times}1024$ pixel monitor of P company and 1536x2048 pixel monitor of Wide are used displaying angiography picture. MARO-view is taken in PACS program, and Visual $C^{++}$ is taken as accomplishing PSNR measurement program. As a result of experiment, no change in No 1, 3 of PSNR appear that there is no error in telephotograph and display. In terms of compressibility, low compressibility has small change of definition, and there was not remarkable drawback of compressibility which has little change in definition.

Automation of Bio-Industrial Process Via Tele-Task Command(I) -identification and 3D coordinate extraction of object- (원격작업 지시를 이용한 생물산업공정의 생력화 (I) -대상체 인식 및 3차원 좌표 추출-)

  • Kim, S. C.;Choi, D. Y.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2001
  • Major deficiencies of current automation scheme including various robots for bioproduction include the lack of task adaptability and real time processing, low job performance for diverse tasks, and the lack of robustness of take results, high system cost, failure of the credit from the operator, and so on. This paper proposed a scheme that could solve the current limitation of task abilities of conventional computer controlled automatic system. The proposed scheme is the man-machine hybrid automation via tele-operation which can handle various bioproduction processes. And it was classified into two categories. One category was the efficient task sharing between operator and CCM(computer controlled machine). The other was the efficient interface between operator and CCM. To realize the proposed concept, task of the object identification and extraction of 3D coordinate of an object was selected. 3D coordinate information was obtained from camera calibration using camera as a measurement device. Two stereo images were obtained by moving a camera certain distance in horizontal direction normal to focal axis and by acquiring two images at different locations. Transformation matrix for camera calibration was obtained via least square error approach using specified 6 known pairs of data points in 2D image and 3D world space. 3D world coordinate was obtained from two sets of image pixel coordinates of both camera images with calibrated transformation matrix. As an interface system between operator and CCM, a touch pad screen mounted on the monitor and remotely captured imaging system were used. Object indication was done by the operator’s finger touch to the captured image using the touch pad screen. A certain size of local image processing area was specified after the touch was made. And image processing was performed with the specified local area to extract desired features of the object. An MS Windows based interface software was developed using Visual C++6.0. The software was developed with four modules such as remote image acquisiton module, task command module, local image processing module and 3D coordinate extraction module. Proposed scheme shoed the feasibility of real time processing, robust and precise object identification, and adaptability of various job and environments though selected sample tasks.

  • PDF

Current Status of the Synchrotron Small-Angle X-ray Scattering Station BL4C1 at the Pohang Accelerator Laboratory

  • Jorg Bolze;Kim, Jehan;Huang, Jung-Yun;Seungyu Rah;Youn, Hwa-Shik;Lee, Byeongdu;Shin, Tae-Joo;Moonhor Ree
    • Macromolecular Research
    • /
    • v.10 no.1
    • /
    • pp.2-12
    • /
    • 2002
  • The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first you of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV. A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available its detectors. The overall performance of the beamline optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, stating from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors.

Preparation of Chitosan-coated Magnetite Nanoparticles (키토산이 피복된 나노 크기의 자성체 분말 제조)

  • Cho, Jun-Hee;Ko, Sang-Gil;Ahn, Yang-Kyu;Song, Ki-Chang;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.102-106
    • /
    • 2006
  • Magnetic nanoparticles can be used for a variety of biomedical applications. They can be used in the targeted delivery of therapeutic agents in vivo, in the hyperthermic treatment of cancers. in magnetic resonance (MR) imaging as contrast agents and in the biomagnetic separations of biomolecules. We have synthesized magnetite $(Fe_3O_4)$ nanoparticles using chemical coprecipitation technique with sodium oleate as surfactant. Nanoparticle size can be varied from 2 to 8nm by controlling the sodium oleate concentration. Magnetite phase nanoparticles could be observed from X-ray diffraction. Magnetic colloid suspensions containing particles with sodium oleate and chitosan have been prepared. Nanoparticles, both oleate-coated and chitosan-coated, have been characterized by several techniques. Atomic farce microscope (AFM) was used to image the coated nanoparticles. Magnetic hysteresis measurement were performed using a superconducting quantum interference device (SQUID) magnetometer at room temperature to investigate the magnetic properties of the magnetite nanoparticles. The SQUID measurements revealed superparamagnetism of nanoparticles.

The Effect of Application of a Non-Elastic Fixation Belt on the Balance Ability and Fall Prevention in Elderly Women (비탄력 고정식 벨트가 노인 여성의 균형능력과 낙상예방에 미치는 영향)

  • Lee, Jang-Tae;Chon, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.398-404
    • /
    • 2017
  • The aim of this study was to determine the effect of a non-elastic fixation belt on the balance ability and fall prevention in elderly women. Elderly women experience reduced balance ability and an increased risk of falls due to a weakening of the surrounding sacroiliac joint and pelvic muscles during childbirth and menopause. On the other hand, specific studies are still needed. The subjects were allocated randomly to two groups: control (n=20) and experimental (n=20). The experimental group used a non-elastic fixation belt, whereas the control group had no fixation belt. The balance ability and the fall index were measured in all subjects using a balance measurement device, and the low abdominal muscle thickness was determined in the experimental group using ultrasound imaging for the exact application of the non-elastic fixation belt. The following statistical analysis was performed: an independent t-test for the general characteristics of the subjects, $2{\times}2$ analysis of variance with repeated measures for the balance and fall index score, and a paired t-test for the abdominal muscle thickness. The group ${\times}$ time interaction effect showed significant improvement in the General Stability Index (F1,38=47.24, p=0.001), Fourier Harmony Index (F1,38=88.83, p=0.001), Weight Distribution Index (F1,38=50.21, p=0.001), and Fall Index (F1,38=21.59, p=0.001). The thicknesses of the transverse abdominal (p=0.001) and internal oblique (p=0.001) muscles were increased significantly in the experimental group after using the non-elastic fixation belt. Overall, the application of a non-elastic fixation belt could be effective in improving the balance ability and fall prevention in elderly women.

CdZnTe Detector for Computed Tomography based on Weighting Potential (가중 퍼텐셜에 기초한 CT용 CdZnTe 소자 설계)

  • Lim, Hyunjong;Park, Chansun;Kim, Jungsu;Kim, Jungmin;Choi, Jonghak;Kim, KiHyun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Room-temperature operating CdZnTe(CZT) material is an innovative radiation detector which could reduce the patient dose to one-tenth level of conventional CT (Computed Tomography) and mammography system. The pixel and pixel pitch in the imaging device determine the conversion efficiency of incident X-or gamma-ray and the cross-talk of signal, that is, image quality of detector system. The weighting potential is the virtual potential determined by the position and geometry of electrode. The weighting potential obtained by computer-based simulation in solving Poisson equation with proper boundaries condition. The pixel was optimized by considering the CIE (charge induced efficiency) and the signal cross-talk in CT detector system. The pixel pitch was 1-mm and the detector thickness was 2-mm in the simulation. The optimized pixel size and inter-pixel distance for maximizing the CIE and minimizing the signal cross-talk is about $750{\mu}m$ and $125{\mu}m$, respectively.

Orchiectomy in the Asiatic Black Bear (Ursus thibetanus) (반달가슴곰에서 시행된 고환절제술)

  • Jeong, Dong-Hyuk;Lee, Seung-Yong;Yang, Jeong-Jin;Seok, Seong-Hoon;Kong, Ju-Yeon;Park, Se-Jin;Jin, So-Young;Kim, Min-Hyang;Lee, Bae-Keun;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.363-365
    • /
    • 2015
  • The Asiatic black bear (Ursus thibetanus) is globally protected species and involved in a species restoration program by the Korea National Park Service. However, the bears could not be released into the wild were required regulation of population due to the limited space of breeding facility, so surgical castration was performed in two males. Bears were immobilized with a combination of 2 mg/kg tiletamine-zolazepam and $40{\mu}g/kg$ medetomidine, and general anesthesia was maintained with isoflurane via endotracheal tube intubation. Orchiectomy was carried out by the closed method using the LigaSure vessel sealing device through pre-scrotal incision. Subcutaneous tissues of the incision site were sutured by continuous pattern with absorbable suture material, and the skin incision was closed with tissue glue. The bears recovered uneventfully from general anesthesia after a duration of 58 min (bear A) and 53 min (bear B). Total surgical time was 26 min (bear A) and 24 min (bear B). No postoperative swelling or complications were observed. This is the first report that describes the use of the LigaSure for orchiectomy in the Asiatic black bear.

Microsurgical DREZotomy for Deafferentation Pain (구심로 차단 동통에서의 미세 후근 진입부 절제술)

  • Kim, Seong-Rim;Lee, Kyung Jin;Cho, Jeong Gi;Rha, Hyung Kyun;Park, Hae Kwan;Kang, Joon Ki;Choi, Chang Rak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.85-90
    • /
    • 2001
  • Objective : DREZotomy is effective for the treatment of deafferentation pain as a consequence of root avulsion, postparaplegic pain, posttraumatic syrinx, postherpetic neuralgia, spinal cord injury, and peripheral nerve injury. We performed microsurgical DREZotomy to the patients with deafferentation pain and relieved pain without any serious complication. The purpose of this study is to evaluate the usefulness of the microsurgical DREZotomy for deafferentation pain. Methods : We evaluated 4 patients with deafferntation pain who were intractable to medical therapy. Two of them were brachial plexus injury with root avulsion owing to trauma, one was axillary metastasis of the squamous cell carcinoma of the left forearm, and the last was anesthesia dolorosa after surgical treatment(MVD and rhizotomy) of trigeminal neuralgia. Preoperative evaluation was based on the neurologic examination, radiologic imaging, and electrophysiological study. In the case of anesthesia dolorosa, we produced two parallel lesions in cephalocaudal direction, 2mm in distance, from the C2 dorsal rootlet to the 5mm superior to the obex including nucleus caudalis, after suboccipital craniectomy and C1-2 laminectomy, with use of microelectrode. In the others, we confirmed lesion site with identification of the nerve root after hemilaminectomy. We performed arachnoid dissection along the posterolateral sulcus and made lesion with microsurgical knife and microelectrocoagulation, 2mm in depth, 2mm in distance, to the direction of 30-45 degrees in the medial portion of the Lissauer's tract and the most dorsal layers of the posterior horn at the one root level above and below the lesion. Results : Compared with preoperative state, microsurgical DREZotomy significantly diminished dosage of the drugs and relieved pain meaningfully. One patient showed tansient ipsilateral ataxia, but recovered soon. There was not any serious complication. Conclusion : It may be concluded that microsurgical DREZotomy is very useful and safe therapeutic modality for deafferentation pain, especially segmentally distributed intermittent or evoke pain. Complete preoperative evaluation and proper selection of the patients and lesion making device are needed to improve the result.

  • PDF

A Study on the Comparison of Learning Performance in Capsule Endoscopy by Generating of PSR-Weigted Image (폴립 가중치 영상 생성을 통한 캡슐내시경 영상의 학습 성능 비교 연구)

  • Lim, Changnam;Park, Ye-Seul;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.6
    • /
    • pp.251-256
    • /
    • 2019
  • A capsule endoscopy is a medical device that can capture an entire digestive organ from the esophagus to the anus at one time. It produces a vast amount of images consisted of about 8~12 hours in length and more than 50,000 frames on a single examination. However, since the analysis of endoscopic images is performed manually by a medical imaging specialist, the automation requirements of the analysis are increasing to assist diagnosis of the disease in the image. Among them, this study focused on automatic detection of polyp images. A polyp is a protruding lesion that can be found in the gastrointestinal tract. In this paper, we propose a weighted-image generation method to enhance the polyp image learning by multi-scale analysis. It is a way to extract the suspicious region of the polyp through the multi-scale analysis and combine it with the original image to generate a weighted image, that can enhance the polyp image learning. We experimented with SVM and RF which is one of the machine learning methods for 452 pieces of collected data. The F1-score of detecting the polyp with only original images was 89.3%, but when combined with the weighted images generated by the proposed method, the F1-score was improved to about 93.1%.