• Title/Summary/Keyword: image projector

Search Result 116, Processing Time 0.029 seconds

Magnification Device of Computed Tomography in Radiation Therapy Planning (방사선치료계획을 위한 진단용 CT 영상의 확대장치)

  • Yoon, Sei-Chul;Kim, Jong-Woo;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.179-181
    • /
    • 1986
  • Computed tomography (CT) adds a new dimension in the study of body contour, organs, and tissues as well as various pathologic conditions. This modality provides a great degree of accuracy in radiation therapy Planning (RTP). However, CT images are usually taken on a small reduced format so that possible errors can be made during inputting the CT data into an automatic planner. Authors have designed a simple inexpensive magnifying device of CT images to obviate errors created by reduced image.

  • PDF

Optical Approach for Increasing the Resolution of Displayed Multi-view Image from Projection Type of Auto-stereoscopic 3D Display System by Adopting a Commercial Spherical Lenticular Lens Sheet (프로젝션 기반 무안경 방식 멀티뷰 3D 디스플레이에서 구면 렌티큐라 렌즈 시트를 이용하여 재생된 입체영상의 해상도를 증가시키는 광학적 접근 방법)

  • Sohn, Young-Sub;Kim, Sung-Kyu;Sohn, Kwanghoon;Lee, Kwang-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.147-153
    • /
    • 2012
  • Multi-view 3D displays based on a limited number of pixels have the problem that the stereo-scopic image has a low resolution because of increasing view number. To solve the problem of low resolution, we propose an optical approaching method that focuses the width of a unit pixel by using a commercial spherical shape lenticular lens sheet and increases the effective resolution by increasing the number of sources of light in the multi-view 3D display system based on projection type. The method was performed in such an order that several main derivable parameters were defined, and, through the theoretical and experimental result, the value of the contractible unit pixel width and the scalable effective resolution was derived in a given system environment. As a result, for the case that the ray of light from the projector transmitted the 25 LPI lenticular lens sheet which has the pitch size 1.016 mm, the focused unit pixel width was 0.19 mm and the scalable effective resolution was, at most, 5 times wider than the original one. In addition, the range of depth of focus was 1.496 mm, which shows us the range of thickness tolerances of commercial spherical shape lenticular lens sheet and sufficient optical alignment tolerances.

Studies on Pulping of Sponge Gourd Net Fiber - Analysis of Morphology and Characteristics of Pulps - (수세미외 섬유의 펄프화에 관한 연구-섬유의 구조와 펄프화별 특징 분석-)

  • Kim, Jong-Gyu;Rho, Jae-Seong;Lee, Jong-Shin
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.1014-1021
    • /
    • 1997
  • Studies were carried out on the preparation of several kinds of pulps from Sponge gourd fiber by KP, ASP, SP PAP, AP and addition of AQ pulping process. These unbeaten and beaten pulping fibers were observed their characteristics and fiber structure by SEM, FQA, Image analyzer and Micro projector. The results were summarized as follows; 1) The cooking condition which is the possible defibrilation of Shives are KP base($160^{\circ}C$, 2hr.), ASP base($155^{\circ}C$, 4hr.), PAP base($160^{\circ}C$, 1hr.). From the results, the kappa no. had the range of 12, 25, 10 each other. 2) The pulp yields of sponge gourd fiber obtained the range of KP 50~55%, ASP&60~70% and PAP 45~50%. SP base have the highest and contnets of KP&PAP base are much the same as woods. 3) Increasing amount of NaOH on Pulping was accelerated the defibrilation of Shives and was changed a morphology of pulping fiber quality such as fiber length, curl and kink index. 4) Addition of AQ on pulping process of sponge gourd fiber had a affect to raise the rate of delignification while protecting cellullosic components against degradation, especially defibrilation was very excellent, beated pulp much more easily and increased the fibrilation. 5) ASP system have higher bulk density, fiber bonding and protecting cellullosic components against degradation than KP or PAP. 6) The color reactions of the "C" stain solution showed blue or blue-gray with clean and transparency thin cell wall.

  • PDF

Color Correction for Projected Image on Light Colored Screen using a Still Camera (카메라를 사용한 유색 스크린에 투영된 영상의 색 보정 기법)

  • Kim, Dae-Chul;Lee, Tae-Hyoung;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.1
    • /
    • pp.16-22
    • /
    • 2011
  • Recently, the use of portable projector expands applications to meeting at fields. Accordingly, the projection is not always guaranteed on white screen, causing some color distortion. Several algorithms have been suggested to correct the projected color on the light colored screen. These have limitation on the use of measurement equipment which can't bring always. In this paper, color correction method using general still camera as convenient measurement equipment is proposed to match the colors between on white and colored screens. A patch containing 9 ramps of each channel are firstly projected on white and colored screens, then captured by the camera, respectively, Next, digital values are obtained by the captured image for each ramp patch on both screens, resulting in different values to the same patch. After that, we check which ramp patch on colored screen has the same digital value on white screen, repeating this procedure for all ramp patches. The difference between corresponding ramp patches reveals the quantity of color shift. Then, color correction matrix is obtained by regression method using matched values. In the experimental results, the proposed method gives better color correction on the objective and subjective evaluation than the previous methods.

Study on the Repeatability and Reproductivity of a Moire Body Shape Analyser (모아레를 이용한 체형분석의 반복성 재현성에 관한 연구)

  • Lee, Dong-Yup;Park, Young-Bae;Oh, Hwan-Sub
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.121-131
    • /
    • 2006
  • Background : As each human has a look in the face of oneself, he or she has a look of him or herself in the shape of the body also. And for the shape of the body which gives a big clue in diagnosis in musculoskeletal disorders. Therefor many means are used and developed for diagnosis through body shape or posture analysis for musculoskeletal disorders. X-ray, CT, MRI has been used for diagnosis through image in this way to tell about the inside of the human body. On the other side, moire topography was used for information about the exterior of the human body, but yet only minimal information such as the number of contour lines in each side was available. Therefor there were a few studies to use moire topography or other methods to get information about the surface of the human body in numeric values. The instrument used in this study which is a laser projection moire, is another trial to get numeric data about the surface of the human body. The instrument is composed of laser projector and a computer software to recompose and analyse the image data into depth, height, angle and length. Objectives : The study was focused on whether the instrument is reliable for clinic use, and to seek the proper environment and posture for the examination, and among the data the software provides, which items are more reliable and useful. Methods : For reproductivity and repeatability, 4 testers tested 2 persons. And to how if the body shape changes according to the posture and which posture gives the most reliable data, the test was performed in 6 different positions. Results : Result, the instrument showed sufficient repeatability and reproductivity for clinical use. And among the items the software provides, the length of the back, the angle of the back in the sagittal and coronal plane showed reliable results. And there was difference in the results according to the posture, and Therefor, in following studies using this instrument or similar type of posture analysing instruments, the length of the back, the angle of the back in the sagittal and coronal plane could be reliable item to use.

  • PDF

A Euclidean Reconstruction of 3D Face Data Using a One-Shot Absolutely Coded Pattern (단일 투사 절대 코드 패턴을 이용한 3차원 얼굴 데이터의 유클리디안 복원)

  • Kim, Byoung-Woo;Yu, Sun-Jin;Lee, Sang-Youn
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.133-140
    • /
    • 2005
  • This paper presents a rapid face shape acquisition system. The system is composed of two cameras and one projector. The technique works by projecting a pattern on the object and capturing two images with two cameras. We use a 'one shot' system which provides 3D data acquired by single image per camera. The system is good for rapid data acquisition as our purpose. We use the 'absolutely coded pattern' using the hue and saturation of pattern lines. In this 'absolutely coded pattern' all patterns have absolute identification numbers. We solve the correspondence problem between the two images by using epipolar geometry and absolute identification numbers. In comparison to the 'relatively coded pattern' which uses relative identification numbers, the 'absolutely coded pattern' helps obtain rapid 3D data by one to one point matching on an epipolar line. Because we use two cameras, we obtain two images which have similar hue and saturation. This enables us to have the same absolute identification numbers in both images, and we can use the absolutely coded pattern for solving the correspondence problem. The proposed technique is applied to face data and the total time for shape acquisition is estimated.