• 제목/요약/키워드: image grabber

검색결과 138건 처리시간 0.023초

초음파 열화상 검사를 이용한 박판 용접시편의 결함 검출 (A Defect Detection of Thin Welded Plate using an Ultrasonic Infrared Imaging)

  • 조재완;정진만;최영수;정승호;정현규
    • 제어로봇시스템학회논문지
    • /
    • 제13권11호
    • /
    • pp.1060-1066
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material efficiently. In this paper a detection of the welding defect of thin SUS 304 plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (20kHz) ultrasonic transducer was used to infuse the welded thin SUS 304 plates with a short pulse of sound for 280ms. The ultrasonic source has a maximum power of 2kW. The surface temperature of the area under inspection is imaged by a thermal infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the defect tip and heated up highly, are observed. From the sequence of the thermosonic images, the location of defective or inhomogeneous regions in the welded thin SUS 304 plates can be detected easily.

CCTV유형 CCD 카메라를 이용한 근거리 산업사진측량의 정확도 (Accuracy of Close-Range Industrial Photogrammetry Using CCTV Type CCD Camera)

  • 이진덕;최용진
    • 한국측량학회지
    • /
    • 제19권3호
    • /
    • pp.283-290
    • /
    • 2001
  • 저가의 CCTV유형 CCD카메라를 기반으로 하는 수치 근거리사진측량 시스템의 산업정밀측정의 수행능력을 평가하기 위하여 CCD카메라, 프레임그래버, 수치영상 측정 및 자체검정 광속조정 기법을 통합한 수치근거리 사진측량시스템이 구축되었다. 이 시스템의 적용실험을 위하여 정육면체 형상의 인공어초를 대상물로하여 다중지점 수렴 네트워크상에서 수치영상을 획득하였다. 자체검정 광속조정기법에 의해 CCD 카메라의 기하학적 검정과 동시에 대상물 전면에 대한 사진삼각측량을 수행하였다. 또한 이미 높은 정확도 잠재성이 입증된 고해상도 스틸비디오 카메라(Kodak DCS)를 유사한 네트워크 조건에서 이용하여 처리함으로써 서로 다른 유형의 카메라를 기반으로 하는 두 시스템의 사진삼각측량 결과의 정확도를 비교하였다.

  • PDF

Miniature Stereo-PIV 시스템의 개발과 응용 (Development and Application of a Miniature Stereo-PIV System)

  • 김경천;;김상혁
    • 대한기계학회논문집B
    • /
    • 제27권11호
    • /
    • pp.1637-1644
    • /
    • 2003
  • Stereoscopic particle image velocimetry is a measurement technique to acquire three dimensional velocity field by two cameras. With a laser sheet illumination, the third velocity component can be deduced from out-of$.$plane velocity components using a stereoscopic matching method. Most industrial fluid flows are three dimensional turbulent flows, so it is necessary to use the stereoscopic PIV measurement method. However the existing stereoscopic PIV system seems hard to use since it is very expensive and complex. In this study we have developed a Miniature Stereo-PIV(MSPIV) system based on the concept of the Miniature PIV system which we have already developed. In this paper, we address the design and some primitive experimental results of the Miniature Stereo-PIV system. The Miniature Stereo-PIV system features relatively modest performances, but is considerably smaller, cheaper and easy to handle. The proposed Miniature Stereo-PIV system uses two one-chip-only CMOS cameras with digital output. Only two other chips are needed, one for a buffer memory and one for an interfacing logic that controls the system. Images are transferred to a personal computer (PC) via its standard parallel port. No extra hardware is required (in particular, no frame grabber board is needed).

방사선사진용 디지털 영상시스템의 정량적 평가에 관한 실험적 연구 (EXPERIMENTAL STUDY ON QUANTITATIVE EVALUATION OF FILM-BASED DIGITAL IMAGING SYSTEM)

  • 조형희;김은경
    • 치과방사선
    • /
    • 제24권1호
    • /
    • pp.137-147
    • /
    • 1994
  • A digital imaging system using Machintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quickcapture Frame Grabber Board was evaluated for quantitative analysis of standardized periapical film with aluminum step wedge. The results were as follows: 1. Correlation between Al thickness and gray level was high-positively associated(r²=0.99, p<0.001). 2. Correlation between measured weight of experimental lesion and estimated relative lesion volume by digital subtracted radiography was also high-positively associated (r²=0.98, p<0.001). 3. As exposure time was increased, mean gray level was decreased(p<0.01) and slope of regression line between Al thickness and gray level was also decreased (p<0.01). And when the exposure time was shorter than 0.2 second, the value of r² was relatively low. On the basis of the above results, it is considered that this digital imaging system using a Macintosh Ⅱ ci computer & a high resolution CCD monochrome camera will be useful in evaluating digitized image from standardized periapical film quantitatively.

  • PDF

PTV에 의한 채널캐비티 유동의 속도 및 압력계측 (Velocity and Pressure Measurement of Channel Cavity Flow by PTV)

  • 조대환;김진구;이영호
    • 태양에너지
    • /
    • 제17권3호
    • /
    • pp.59-66
    • /
    • 1997
  • 본 연구에서는 PTV기법에 의해 속도를 계측하였으며 계측시스템은 레이저를 이용한 시이트라이트와 이미지보오드를 내장한 퍼스널컴퓨터 그리고 관련 소프트웨어로 구성하였다. 속도벡터는 PTV 시스템에 의해 구하였으며 그 결과를 압력에 관한 프와송방정식에 적용하여 전유동장의 압력을 구하였다. 이때의 경계조건으로서는 벽면에서는 부착조건을 부여하였고 구동류가 흐르는 캐비티의 상부에서는 내부의 속도 값을 외삽하였다. 압력계산에 있어서 격자의 해상도는 $40{\times}40$이며 등간격의 엇갈림격자를 사용하였다. 계측결과는 유동장의 속도 및 압력분포를 잘 나타내었다.

  • PDF

적혈구 변형성의 측정과 혈액 점도와의 상관관계 연구 (Measurements of RBC deformability and its effect on blood viscosity)

  • 구윤희;박명수;신세현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1682-1686
    • /
    • 2004
  • A slit-flow apparatus with laser diffraction method has been developed with significant advances in ektacytometry design, operation and data analysis. In the slit-flow ektacytometry (or laser-diffractometry), the deformation of red blood cells subjected to continuously decreasing shear stress in slit flow is measured. A laser beam traverses a diluted blood suspension flowing through a slit and is diffracted by RBCs in the volume. The diffraction patterns are captured by a CCD-video camera, linked to a frame grabber integrated with a computer, while the differential pressure variation is measured by a pressure transducer. Both measurements of laser-diffraction image and pressure with respect to time enable to determine deformation index and the shear stress. The range of shear stress of 0 ${\sim}$ 35 Pa and measuring time is less than 2 min. When deforming under decreasing shear stress, RBCs change gradually from the prolate ellipsoid towards a circular biconcave morphology. The Deformation Index (DI) as a measure of RBC deformability is determined from an isointensity curve in the diffraction pattern using an ellipse-fitting program. The advantages of this design are simplicity, i.e., ease of operation and no moving parts, low cost, short operating time, and the disposable kit which is contacted with blood sample.

  • PDF

고로의 연소효율을 높이기 위한 미분탄 공급 시스템 개발 (Pulverized coal injection system development to raise combustion efficiencies of a blast furnace)

  • 안영진;강법성;곽남수;최경민;이민철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3163-3168
    • /
    • 2008
  • Pulverized coal (PC) has become an important auxiliary fuel in the iron and steel industry since the technique of pulverized coal injection (PCI) system was developed for iron making. Combustion efficiencies of pulverized coal in blowpipes and tuyeres under various operational are numerically predicted to recognize the performance with the locations of nozzles in a blast furnace. A variety of parameters including the pulverized coal quantities, oxygen amounts, inlet temperature of the tuyeres and mass flow rate of coal carrier gas are taken into consideration. Also In order to develop more efficient than existing coal injection system, this study applies a flame measurement system using a charge couple device (CCD) camera and frame grabber. And it has used algorithms of auto sampling from flame shape information and composed the device for location control of PCI. This study find to further improve the blast furnace performance by the control of PCI locations.

  • PDF

광학적 입자열 측정법에 의한 폴리스티렌구의 평균지름 측정 (Calibration of monodisperse polystylene spheres of size from 1 to 10 ${\mu}m$ by using optical array sizing method)

  • 강주식
    • 한국광학회지
    • /
    • 제10권1호
    • /
    • pp.21-26
    • /
    • 1999
  • 광학적 입자열 측정법을 사용하여 공칭크기가 1, 2, 3, 5, 그리고 10$\mu$m인 플로스티렌 표준구의 평균지름을 측정하고 불확도를 분석하였다. 광학적 입자열 측정법이란, 슬라이드 글라스 위에 표준입자를 6각형 구조로 배열시킨 후, 입자열의 길이를 측정하고 이를 입자의 개수로 나누어 평균지름을 구하는 평균지름을 구하는 방법을 말하는데, 본 연구에서는 CCD 카메라와 화상처리를 도입함으로써 기존의 목측에 의한 측정방법보다 정확하고 편리하게 측정할 수 있도록 하였다. 입자열의 현미경 상을 CCD카메아로 얻은 후 소프트웨어 필터를 적용시켜 입자열의 길이를 화면의 픽셀단위로 측정하였으며, 이를 실제 길이로 환산하기 위해, 스템이지 마이크로미터의 현미경 상에 역시 필터를 적용시켜 구한 길이환산계수응 곱하였다. 이 길이를 입자열을 이루는 입자의 개수로 나누고, 공기층에 의한 입자의 찌그러짐 효과를 보정한 결과, 각 입자의 평균지름은 제조 회사의 인증값과 0.7% 이내로 일치하였며, 측정불확도는 1.5% 이내로 얻어졌다.

  • PDF

Neuro-Net Based Automatic Sorting And Grading of A Mushroom (Lentinus Edodes L)

  • Hwang, H.;Lee, C.H.;Han, J.H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.1243-1253
    • /
    • 1993
  • Visual features of a mushroom(Lentinus Edodes L) are critical in sorting and grading as most agricultural products are. Because of its complex and various visual features, grading and sorting of mushrooms have been done manually by the human expert. Though actions involved in human grading looks simple, a decision making undereath the simple action comes form the results of the complex neural processing of the visual image. And processing details involved in the visual recognition of the human brain has not been fully investigated yet. Recently, however, an artificial neural network has drawn a great attention because of its functional capability as a partial substitute of the human brain. Since most agricultural products are not uniquely defined in its physical properties and do not have a well defined job structure, a research of the neuro-net based human like information processing toward the agricultural product and processing are widely open and promising. In this pape , neuro-net based grading and sorting system was developed for a mushroom . A computer vision system was utilized for extracting and quantifying the qualitative visual features of sampled mushrooms. The extracted visual features and their corresponding grades were used as input/output pairs for training the neural network and the trained results of the network were presented . The computer vision system used is composed of the IBM PC compatible 386DX, ITEX PFG frame grabber, B/W CCD camera , VGA color graphic monitor , and image output RGB monitor.

  • PDF

CCD카메라를 이용한 수종 전부도재관의 변연적합도에 관한 연구 (A STUDY ON THE MARGINAL FIT OF ALL-CERAMIC CROWNS USING CCD CAMERA)

  • 문병화;양재호;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.273-292
    • /
    • 1998
  • The purpose of this study was to evaluate marginal fit of four all-ceramic crown systems 1) conventional In-Ceram, 2) copy-milled In-Ceram using Celay system, 3) IPS Empress, 4) OPC(Optimal Pressable Ceramic). All ceramic crowns were made on epoxy dies. The fabricated crowns were sandblasted, cleaned with ultrasonic cleansing, silanated, and cemented with Bistite composite resin cement. the selected marginal areas of the crowns were the labial, lingual, mesial, and distal surface. Each selected area of surface was $0.6{\times}1.6mm$ in dimension. The image of each marginal area was captured to computer files using DT-55 Frame Grabber and light microscope connected CCD camera. The marginal gaps were measured every $70{\mu}m$ using computer image analysis program. The results obtained were summarized as follows : 1. The marginal fit of four all-ceramic crowns were significantly different from each other(p<0.01), and mean marginal fit values obtained were $31.42{\pm}16.52{\mu}m$ in conventional In-Ceram, $55.45{\pm}27.90{\mu}m$ in copy-milled In-Ceram using Celay system, $44.36{\pm}24.59{\mu}m$ in IPS Empress, $47.21{\pm}20.42{\mu}m$ in OPC. 2. In the marginal fit of conventional In-Ceraw and copy-milled In-Ceram crowns using Celay system there was no significant difference between mesiodistal and buccolingual surface, but in the marginal fit of IPS Empress and OPC crowns, there was significant difference between mesiodistal and buccolingual surface(p<0.01). 3. The marginal fit of four kinds of all-ceramic crowns was clinically acceptable.

  • PDF