• 제목/요약/키워드: image encoding

검색결과 428건 처리시간 0.024초

Orthodontic appliances and MR image artefacts: An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners

  • Sonesson, Mikael;Al-Qabandi, Fahad;Mansson, Sven;Abdulraheem, Salem;Bondemark, Lars;Hellen-Halme, Kristina
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.63-71
    • /
    • 2021
  • Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.

이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발 (Development of JPEG2000 Viewer for Mobile Image System)

  • 김새롬;정해조;강원석;이재훈;이상호;신성범;유선국;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.124-130
    • /
    • 2003
  • 현재, 많은 병원이 방사선과 의료영상정보를 기존의 필름형태로 판독하고, 진료하는 방식에서 PACS를 도입하여 디지털 형태로 영상을 전송, 저장, 검색, 판독하는 환경으로 변화하고 있다. 한편, PACS가 가지는 가장 큰 제한점은 휴대성의 결핍이다. 본 연구는 이동형 장치가 가지는 호스트의 이동성 및 휴대성의 장점들을 살리면서, 무선 채널 용량의 한계, 무선 링크 사용이라는 제약점들을 감안하여 의료영상을 JPEG2000 영상압축 방식으로 부호화한 후 무선 환경을 고려한 전송 패킷의 크기를 결정하고자 하였으며, 무선 통신 중 발생되는 패킷 손실에 대응하기 위한 자동 오류 수정 기능도 함께 구현하고자하였다. Window 2000 운영체계에서 의료영상을 로드하고, 데이터베이스화하며, 저장하고, 다른 네트워크와 접속, 제어가 가능한 PC급 서버를 구축하였다. 영상데이터는 무선망을 통해 전송하기 때문에 가장 높은 압축비율을 지원하면서 에너지 밀도가 높은 JPEG2000 알고리즘을 사용하여 영상을 압축하였다. 또한, 무선망 사용으로 인한 패킷 손실에 대비하여, 영상을 JPEG2000 방식으로 부호화한 후 각 블록단위로 전송하였다. PDA에서 JPEG2000 영상을 복호화 하는데 걸리는 시간은 256*256 크기의 MR 뇌영상의 경우 바로 확인할 수 있었지만, 800*790 크기의 CR 흥부 영상의 경우 약 5초 정도의 시간이 걸렸다. CDMA 1X(Code-Division Multiple Access 1st Generation) 모듈을 사용하여 영상을 전송하는 경우, 256 byte/sec정도에서는 안정된 전송 결과를 보여주었고, 1 Kbyte/sec정도의 전송의 경우 중간 중간에 패킷이 손실되는 결과를 관찰할 수 있었다. 반면 무선 랜의 경우 이보다 더 큰 패킷을 전송하더라도 문제점은 발견되지 않았다. 현재의 PACS는 유선과 무선사이의 인터페이스의 부재로 인해 유무선 연동이 되지 못하고 있다. 따라서 이동형 JPEG2000 영상 뷰어는 PACS가 가지는 문제점인 휴대성을 보완하기 위하여 개발되었다. 또한 무선망이 가지는 데이터 손실에 대하여서도 허용할 수 있는 범위에서 재전송을 가능하게 함으로서 약한 연결성을 보완하였다. 본 JPEG2000 영상 뷰어 시스템은 기존 유선상의 PACS와 이동형 장치간에 유기적인 인터페이스 역할을 하리라 기대된다.

  • PDF

Design and Simulation of Depth-Encoding PET Detector using Wavelength-Shifting (WLS) Fiber Readout

  • An, Su Jung;Kim, Hyun-il;Lee, Chae Young;Song, Han Kyeol;Park, Chan Woo;Chung, Young Hyun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권5호
    • /
    • pp.305-310
    • /
    • 2015
  • We propose a new concept for a depth of interaction (DOI) positron emission tomography (PET) detector based on dual-ended-scintillator (DES) readout for small animal imaging. The detector consists of lutetium yttrium orthosilicate (LYSO) arrays coupled with orthogonal wavelength-shifting (WLS) fibre placed on the top and bottom of the arrays. On every other line, crystals that are 2 mm shorter are arranged to create grooves. WLS fibre is inserted into these grooves. This paper describes the design and performance evaluation of this PET detector using Monte Carlo simulations. To investigate sensitivity by crystal size, five types of PET detectors were simulated. Because the proposed detector is composed of crystals with three different lengths, degradation in sensitivity across the field of view was also explored by simulation. In addition, the effect of DOI resolution on image quality was demonstrated. The simulation results proved that the devised PET detector with excellent DOI resolution is helpful for reducing the channels of sensors/electronics and minimizing gamma ray attenuation and scattering while maintaining good detector performance.

웨이블릿 기반의 고속 움직임 예측 기법 (A wavelet-based fast motion estimation)

  • 배진우;선동우;유지상
    • 방송공학회논문지
    • /
    • 제8권3호
    • /
    • pp.297-305
    • /
    • 2003
  • 본 논문에서는 저비트율 부호화에 적합한 웨이블릿 기반의 고속 움직임 예측 기법을 제안한다. 제안한 논문에서는 웨이블릿 계수의 차이를 기반으로 한 중요 블록(significant block : SB) 정보를 사용하여 움직임이 존재하는 블록에 대해 선택적으로 움직임 예측함으로써 움직임 벡터의 수가 증가하는 MRME(multiresolution motion estimation)의 단점을 보완할 수 있었다. 또한 웨이블릿 변환의 특성 중 하나인 해상도 분할 특성을 이용하여 quarter-band까지 움직임을 예측하게 되고, 이에 대한 보간작업으로 영상을 재구성한다. 선택적 움직임 추정과 움직임 보상된 quarter-band의 보간작업을 통해 고주파 부대역에서 존재할 수 있는 예측 오차를 줄일 수 있었으며, 동시에 계산량도 감소시킬 수 있었다. 제안된 기법은 기존의 기법과 비교하여 약 70% 이상의 계산량을 감소시킬 수 있었으며, 영상의 화질 면에서도 0.1 ∼ 1.2dB 정도 향상되어 거의 대등한 PSNR을 유지하는 것을 모의 실험을 통하여 확인하였다.

An Incidentally Identified Sporadic Case with Adrenoleukodystrophy with the ABCD1 Mutation

  • Shin, Soon-Jung;Kim, Ja Hye;Kim, Yoo-Mi;Kim, Gu-Hwan;Lee, Beom Hee;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • 제10권1호
    • /
    • pp.43-46
    • /
    • 2013
  • Adrenoleukodystrophy (ALD) is an X-linked disorder which has diverse constellation of clinical pictures, ranging from the severe childhood cerebral form to adrenocortical insufficiency without neurological manifestations. This disorder is caused by the mutations in the ABCD1 gene encoding the adrenoleukodystrophy protein (ALDP), a transporter in the peroxisome membrane. ALD in most cases is inherited from one parent. Here, we report an incidentally identified sporadic case with ALD after traffic accident. He had adrenocortical insufficiency as well as abnormal findings in brain image. Genetic testing of ABCD1 gene revealed a previously reported mutation. With the description of clinical features of ALD in this patient, we discussed the difficulty in determining an appropriate therapeutic option for ALD patients with minimal neurological manifestation.

Performance Evaluation of a Rapid Three Dimensional Diffusion MRI

  • Numano, Tomokazu;Homma, Kazuhiro;Nishimura, Katsuyuki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.356-358
    • /
    • 2002
  • MRI, particularly diffusion weighted imaging (DWI), plays vital roles in detection of the acute brain infarction$\^$1-4/ and others metabolic changes of biological tissues. In general, every molecule in biological tissues may diffuse and move randomly in three-dimensional space. However, in clinical diagnosis, only 2D-DWI is used. The authors have developed a new method for rapid three-dimensional DWI (3D-DWI). In this method, by refocusing of the magnetized spin with the applied gradient field, direction of which is opposite to phase encoding field. Magnetized spin of $^1$H is kept under the SSFP (steady state free precession)$\^$5-6/. Under SSFP, in addition of FID, spin echo and stimulated echo are also generated, so the acquired signal is increased. The signal intensity is increased depending on flip angle (FA) of magnetized spin. This phenomenon is confirmed by human brain and phantom studies. The performance of this method is quantitatively analyzed by using both of conventional spin echo DWI and 3D-DWI. From experimental results, three dimensional diffusion weighted images are obtained correctly for liquid phantoms (water, acetone and oil), diffusion coefficient is enhanced in each image. Therefore, this method will provide useful information for clinical diagnosis.

  • PDF

고효율 엔트로피 부호화를 위한 ICMEP 알고리즘 설계 (Design of the ICMEP Algorithm for the Highly Efficient Entropy Encoding)

  • 이선근;임순자;김환용
    • 대한전자공학회논문지SD
    • /
    • 제41권4호
    • /
    • pp.75-82
    • /
    • 2004
  • 압축 과정 중에 빠른 처리율을 보여주는 렘펠-짚 알고리즘의 결합에 의하여 채널 전송율은 증가한다. 영상정보의 압축 과정동안 처리율을 향상시키기 위하여 ICMEP 알고리즘을 제안하였으며 HDTV에 적용시켜 엔트로피 부호화기를 설계하였으며 이를 검증하였다. ICMEP 엔트로피 암호기는 top-down 방식을 이용하여 설계하였으며 VHDL을 이용하여 회로 합성 및 모의실험을 수행하였다. 모의실험 결과, 구현된 ICHEP 엔트로피 부호화기는 메모리 포화방지 및 압축률 증가로 인하여 전체적인 시스템 효율이 향상됨을 확인하였다.

Fast Encoder Design for Multi-view Video

  • Zhao, Fan;Liao, Kaiyang;Zhang, Erhu;Qu, Fangying
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권7호
    • /
    • pp.2464-2479
    • /
    • 2014
  • Multi-view video coding is an international encoding standard that attains good performance by fully utilizing temporal and inter-view correlations. However, it suffers from high computational complexity. This paper presents a fast encoder design to reduce the level of complexity. First, when the temporal correlation of a group of pictures is sufficiently strong, macroblock-based inter-view prediction is not employed for the non-anchor pictures of B-views. Second, when the disparity between two adjacent views is above some threshold, frame-based inter-view prediction is disabled. Third, inter-view prediction is not performed on boundary macroblocks in the auxiliary views, because the references for these blocks may not exist in neighboring views. Fourth, finer partitions of inter-view prediction are cancelled for macroblocks in static image areas. Finally, when estimating the disparity of a macroblock, the search range is adjusted according to the mode size distribution of the neighboring view. Compared with reference software, these techniques produce an average time reduction of 83.65%, while the bit-rate increase and peak signal-to-noise ratio loss are less than 0.54% and 0.05dB, respectively.

회전 경사자계와 사상 재구성을 이용한 무소음 자기 공명 영상법 (Silent Magnetic Resonance Imaging Using Rotating and Projection Reconstruction)

  • 정성택;박세혁;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.555-558
    • /
    • 1997
  • A new approach to silent MR imaging using a rotating DC gradient has been explored and experimentally studied. As is known, acoustic or sound noise has been one of the major problems in handling patients, mainly due to the fast gradient pulsings in interaction with the main magnetic field. The sound noise is also proportionally louder as the magnetic field strength becomes larger. In this article, we have described a new imaging technique using a mechanically rotating DC gradient coil as an approach toward silent MR imaging, i.e., a mechanically rotated DC gradient effectively replaces both the phase encoding as well as the readout gradient pulsings and data obtained in this manner provides a set of project ion data which later can be used or the projection reconstructionorwithsomeinterpolation techniques one can also perform conventional 2-D FFT (Fast Fourier Transform) image reconstruction. We found, with this new technique, that the sound noise intensity compared with the conventional imaging technique, such as spin echo sequence, is reduced down to -20.7 dB or about 117.5 times. The experimental pulse sequence and its principle are described and images obtained by the new silent MR imaging technique are reported.

  • PDF

SAD 정보를 이용한 효율적인 DCT 계산 방식 (An Efficient DCT Calculation Method Based on SAD)

  • 문용호
    • 한국통신학회논문지
    • /
    • 제28권6C호
    • /
    • pp.602-608
    • /
    • 2003
  • 본 논문에서는 고속 동영상 압축을 위한 효율적인 DCT 계산 방식을 제안한다. 본 논문은 먼저 기존 움직임 추정 및 보상 과정에서 얻어지는 SAD가 양수 항과 음수 항의 합으로 분해됨을 유도한다. 그리고 이론적 분석을 통하여 기존 DCT 계산이 양수 항의 합과 음수 항의 합에 따라 DCT 생략, Reduced_DCT1, Reduced_DCT2, 그리고 DCT의 4가지 경우들로 분류될 수 있음을 보인다. 이러한 사실에 기초하여 제안 알고리듬에서는 효율적인 DCT 계산을 위하여 4가지 유형중에 하나가 선택되어 사용되어진다. 모의 실험 결과는 복원 화질의 저하와 부가 계산량 없이 평균 25.2% 정도의 계산량 감소가 이루어짐을 보여준다.