• 제목/요약/키워드: image center

검색결과 4,262건 처리시간 0.042초

Usefulness of Temporal Subtraction for The Detection of Interval Changes of Interstitial Lung Diseases on Chest Radiographs

  • Higashida, Yoshiharu;Ideguchi, Tadamitsu;Muranaka, Toru;Akazawa, Fumio;Miyajima, Ryuichi;Tabata, Nobuyuki;Ikeda, Hirotaka;Ohki, Masafumi;Toyofuku, Fukai;Doi, Kunio
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.454-456
    • /
    • 2002
  • The evaluation of interval changes between temporally sequential chest radiographs is necessary for the detection of new abnormalities or interval changes, such as pulmonary nodules and interstitial disease. For interstitial lung disease, the interval changes are very important for diagnosis and treatment. Especially, interstitial lung disease may show rapid changes in the radiographs, show changes in the entire lung field in minute detail, or show changes in multiple parts depending on the type. It is therefore difficult to have an accurate grasp of the condition of the disease only with conventional radiographs. The temporal subtraction technique which was developed at the University of Chicago, provides a subtraction image of the current warped image and the previous image. A temporal subtraction image, shows only differences and changes between the two images, can be very useful for a diagnosis of interstitial lung disease. However, the evaluation of the temporal subtraction technique for interstitial lung disease using receiver operating characteristic(ROC) studies has not been reported yet. Therefore, we have evaluated the clinical usefulness of a temporal subtraction technique for detection of interval changes of interstitial lung disease by ROC analysis.

  • PDF

레이다 표적 인식에서 표적에 대한 2차원 산란점 추출 및 ISAR 영상 형성에 대한 성능 개선 (Performance Improvement for 2-D Scattering Center Extraction and ISAR Image Formation for a Target in Radar Target Recognition)

  • 신승용;임호;명로훈
    • 한국전자파학회논문지
    • /
    • 제18권8호
    • /
    • pp.984-996
    • /
    • 2007
  • 본 논문에서는 표적에 의해서 산란된 산란파에 대한 2차원 산란점 추출 및 2차원 ISAR(Inverse SAR) 영상 형성에 대해서 기술하였다. 표적 에 대 한 2차원 산란점과 ISAR 영상을 획득하는 방법에는 일반적으로 2-D IFFT(Inverse Fast Fourier Transform)가 널리 사용되고 있다. 그러나 이는 영상의 해상도 면에서 질이 떨이진다는 단점이 있다. 이러한 퓨리에 변환을 바탕으로 한 방법의 단점을 보완하기 위해서 여러 가지 고해상도 신호처리의 방법이 개발되어 왔다. 본 논문에서는 2차원 산란점 추출 및 ISAR 영상을 형성하기 위해서 2-D MEMP 알고리즘과 2-D ESPRIT 알고리즘에 대해서 기술하고 있다. 이러한 각 알고리즘에 대한 성능을 나타내기 위해서 이상적인 점 산란체와 F-18 전투기에 대한 산란파를 이용하여 2차원 산란점을 예측하고 2차원 ISAR 영상을 획득하였다.

RGB 채널치환을 이용한 내시경영상 향상을 위한 예비 연구 (Enhancement of Endoscopic Images by RGB Channel Substitution Image Processing, a Preliminary Report)

  • 이동환;양찬주;정훈용;이재령;남수정;최승호
    • 대한기관식도과학회지
    • /
    • 제18권2호
    • /
    • pp.45-48
    • /
    • 2012
  • Background Neoplastic vessels tend to proliferate on the surface of malignant lesions in the aerodigestive tract. So, superficial malignant lesions can be detected earlier by enhancing mucosal vascular clarity. To enhance mucosal vascular clarity on endoscopic image, we developed an image processing algorithm of RGB (red-green-blue) channel substitution image (CSI). Methods Each pixel in original white light image (WLI) has its own value of red, green and blue channel. Various combinations of RGB channel substitution was tried on original WLI. Results To make superficial blood vessels darker than brighter background mucosa, in the CSI algorithm, RGB value in each pixel of WLI is substituted; red value to green one, green value to blue one. There was a good contrast between superficial mucosal vessels and background brighter mucosa in the CSI image. Conclusion By RGB CSI algorithm, WLI could be successfully converted to new images with enhanced mucosal vascular clarity. Using RGB CSI algorithm could provide added vascular visibility on original WLI.

  • PDF

Diagnostic Performance of Deep Learning-Based Lesion Detection Algorithm in CT for Detecting Hepatic Metastasis from Colorectal Cancer

  • Kiwook Kim;Sungwon Kim;Kyunghwa Han;Heejin Bae;Jaeseung Shin;Joon Seok Lim
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.912-921
    • /
    • 2021
  • Objective: To compare the performance of the deep learning-based lesion detection algorithm (DLLD) in detecting liver metastasis with that of radiologists. Materials and Methods: This clinical retrospective study used 4386-slice computed tomography (CT) images and labels from a training cohort (502 patients with colorectal cancer [CRC] from November 2005 to December 2010) to train the DLLD for detecting liver metastasis, and used CT images of a validation cohort (40 patients with 99 liver metastatic lesions and 45 patients without liver metastasis from January 2011 to December 2011) for comparing the performance of the DLLD with that of readers (three abdominal radiologists and three radiology residents). For per-lesion binary classification, the sensitivity and false positives per patient were measured. Results: A total of 85 patients with CRC were included in the validation cohort. In the comparison based on per-lesion binary classification, the sensitivity of DLLD (81.82%, [81/99]) was comparable to that of abdominal radiologists (80.81%, p = 0.80) and radiology residents (79.46%, p = 0.57). However, the false positives per patient with DLLD (1.330) was higher than that of abdominal radiologists (0.357, p < 0.001) and radiology residents (0.667, p < 0.001). Conclusion: DLLD showed a sensitivity comparable to that of radiologists when detecting liver metastasis in patients initially diagnosed with CRC. However, the false positives of DLLD were higher than those of radiologists. Therefore, DLLD could serve as an assistant tool for detecting liver metastasis instead of a standalone diagnostic tool.

복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구 (A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries)

  • 장지성;최원근;정재연;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

IPS-Mode Dynamic LCD-TV Realization with Low Black Luminance and High Contrast by Adaptive Dynamic Image Control Technology

  • Oh, E.Y.;Baik, S.H.;Sohn, M.H.;Kim, K.D.;Hong, H.J.;Bang, J.Y.;Kwon, K.J.;Kim, M.H.;Jang, H.;Yoon, J.K.;Chung, I.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.799-802
    • /
    • 2004
  • In this paper, the active backlight control technology with data processing algorithm was developed in order to improve image quality for IPS-mode LCD-TV applications. The image blinking problem caused by repeatedly abrupt change of the backlight luminance was solved by algorithms-Fba(Flexible Boundary algorithm) and Cfa(Cumulative Feedback algorithm)-and the optimized number and space of backlight dimming steps based on perception. In the IPS-mode 42" TFT-LCD panel, the dynamic contrast ratio can be more than twice the typical level by means of lower block luminance and higher white luminance. Additionally, Power consumption and LCD temperature was decreased.

  • PDF

53.1 Low power and low EMI display technologies based on the total image systematic approach

  • Okumura, Haruhiko;Baba, Masahiro;Takagi, Ayako;Sasaki, Hisashi;Matsuba, Mitsunori
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1081-1085
    • /
    • 2009
  • We have already developed EMI reducing techniques using lossless compression by vertically differential EMI suppression method (VDE[1]). It applies lossless modulo reduction and data bit mapping optimization for low voltage differential signaling (LVDS) transmission lines, that reduces the probability of transient bit and EMI by 12 dB [6][7]. We also improved and optimized the VDE for low power LCD interface. With this modified VDE algorithm[8], the developed FPGA was measured the reduction of the power consumption of LCD circuit by more than 15 % compared to the conventional methods in the case of 14-in LCD with SXGA resolution. The VDE algorithm is based on the total image systematic approach. In the VDE method, the present image signals are subtracted for the 1H delayed image signals and transferred to a column driver through a PCB. As the vertical correlations for image signals are very high, we expected that most of the vertically subtracted image signals remain 0 level and transient cycles become very long. As a result, the power consumption and EMI are extremely reduced for the transferred image signals on a PCB. In this paper, we discussed our proposed method by emphasizing the fact that systematic approach are important based on not only display point of view but also total system point of view.

  • PDF

Image-based Realistic Facial Expression Animation

  • Yang, Hyun-S.;Han, Tae-Woo;Lee, Ju-Ho
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 1999년도 KOBA 방송기술 워크샵 KOBA Broadcasting Technology Workshop
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, we propose a method of image-based three-dimensional modeling for realistic facial expression. In the proposed method, real human facial images are used to deform a generic three-dimensional mesh model and the deformed model is animated to generate facial expression animation. First, we take several pictures of the same person from several view angles. Then we project a three-dimensional face model onto the plane of each facial image and match the projected model with each image. The results are combined to generate a deformed three-dimensional model. We use the feature-based image metamorphosis to match the projected models with images. We then create a synthetic image from the two-dimensional images of a specific person's face. This synthetic image is texture-mapped to the cylindrical projection of the three-dimensional model. We also propose a muscle-based animation technique to generate realistic facial expression animations. This method facilitates the control of the animation. lastly, we show the animation results of the six represenative facial expressions.

규칙적 운동이 스포츠센터 이용 성인의 체구성과 신체상에 미치는 효과 (The Effect of Regular Exercise Program on Body Composition and Body Image in Adults Using One Fitness Center)

  • 오진환;임난영
    • 기본간호학회지
    • /
    • 제12권1호
    • /
    • pp.15-20
    • /
    • 2005
  • Purpose: This study was done to compare of adult body composition and body image before and after regular exercise program at a sports center. Method: The participants were 32 adults who were beginning regular exercise at a sports center in D city. The body composition was measured by body weight, soft lean mass, fat mass, percent body fat, fat distribution, degree of obesity and BMI, using the Inbody 3.0. Body image. Data were collected using structured questionnaires and analyzed using paired t-test. Results: 1. Significant improvement was shown in body composition. 2. The score for body image increased after the program, but the change was not statistically significant. Conclusion: The short-term exercise program was very effective in improving body composition, but changes in the evaluation of body image need long-term exercise. Also, we were concluded that it is very important to consider preference level when evaluating body composition and body image.

  • PDF

The Evaluation Method for Viewing Angle Image Control (VIC) Technology

  • Kwon, Jung-Bum;Park, Seung-Chul;Le, Don-Gyou;Lee, Lim-Soo;Ahn, Byung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.700-702
    • /
    • 2008
  • A new evaluation method which named 'Security Viewing Angle Factor (SVAF)' was suggested for VIC (Viewing-angle Image Control) technology to quantify a visual hiding performance of LCD. Currently, Contrast Ration (CR) is the general method to evaluate VIC technology. However, CR shows a significant difference when compared with the result of human visual system. Furthermore, a perceptional evaluation method and its conditions were established.

  • PDF