• Title/Summary/Keyword: image acquisition characteristics

Search Result 130, Processing Time 0.026 seconds

Vicarious Radiometric Calibration of the Ground-based Hyperspectral Camera Image (지상 초분광카메라 영상의 복사보정)

  • Shin, Jung-Il;Maghsoudi, Yasser;Kim, Sun-Hwa;Kang, Sung-Jin;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.2
    • /
    • pp.213-222
    • /
    • 2008
  • Although hyperspectral sensing data have shown great potential to derive various surface information that is not usually available from conventional multispectral image, the acquisition of proper hyperspectral image data are often limited. To use ground-based hyperspectral camera image for remote sensing studies, radiometric calibration should be prerequisite. The objective of this study is to develop radiometric calibration procedure to convert image digital number (DN) value to surface reflectance for the 120 bands ground-based hyperspectral camera. Hyperspectral image and spectral measurements were simultaneously obtained from the experimental target that includes 22 different surface materials of diverse spectral characteristics at wavelength range between 400 to 900 nm. Calibration coefficients to convert image DN value to at-sensor radiance were initially derived from the regression equations between the sample image and spectral measurements using ASD spectroradiometer. Assuming that there is no atmospheric effects when the image acquisition and spectral measurements were made at very close distance in ground, we were also able to derive calibration coefficients that directly transform DN value to surface reflectance. However, these coefficients for deriving reflectance values should not be applied when the camera is used for aerial image that contains significant effect from atmosphere and further atmospheric correction procedure is required in such case.

Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form

  • Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.354-362
    • /
    • 2016
  • PURPOSE. The trueness and precision of acquired images of intraoral digital scanners could be influenced by restoration type, preparation outline form, scanning technology and the application of power. The aim of this study is to perform the comparative evaluation of the 3-dimensional reproducibility of intraoral scanners (IOSs). MATERIALS AND METHODS. The phantom containing five prepared teeth was scanned by the reference scanner (Dental Wings) and 5 test IOSs (E4D dentist, Fastscan, iTero, Trios and Zfx Intrascan). The acquired images of the scanner groups were compared with the image from the reference scanner (trueness) and within each scanner groups (precision). Statistical analysis was performed using independent two-samples t-test and analysis of variance (${\alpha}=.05$). RESULTS. The average deviations of trueness and precision of Fastscan, iTero and Trios were significantly lower than the other scanners. According to the restoration type, significantly higher trueness was observed in crown and inlay than in bridge. However, no significant difference was observed among four sites of preparation outline form. If compared by the characteristics of IOS, high trueness was observed in the group adopting the active triangulation and using powder. However, there was no significant difference between the still image acquisition and video acquisition groups. CONCLUSION. Except for two intraoral scanners, Fastscan, iTero and Trios displayed comparable levels of trueness and precision values in tested phantom model. Difference in trueness was observed depending on the restoration type, the preparation outline form and characteristics of IOS, which should be taken into consideration when the intraoral scanning data are utilized.

A Study on Characteristics of Observation Time Found in Image Evaluation of Interior Space - Focusing on Acquisition of Spatial Information by Interior Space Types - (실내공간의 이미지 평가에 나타난 주시시간 특성에 관한 연구 - 실내공간 유형별 정보획득을 중심으로 -)

  • Choi, Joo-Young;Kim, Joo-Hyun;Kim, Jong-Ha;Lee, Jeong-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.5
    • /
    • pp.96-104
    • /
    • 2011
  • Assuming that different spatial types involves the change of observation time to acquire the spatial information, this study intended to analyze the observation time by interior space types and derive the proper time for spatial evaluation. Coming to the study method, in order to analyze the characteristics of observation time in the image evaluation of interior space by types, it looked into the observation time chosen by the testees during evaluation. The findings of this study are as follows: First, the observation time differed by genders and spatial types: men's average time was longest for modern (93.3 sec.) and natural (89.4 sec.) spaces; women's average time was longest for classic space (110.7 sec.), which was the shortest for men. Second, the intensity of observation time zone differed by spatial types: this finding can imply that different design types require different establishment of observation time for evaluation even if the spatial elements are the same. Third, analyzing the distribution of time zones chosen by most testees showed that men's observation time zones were more intensely distributed than those of women. Fourthly, the observation lime for general space could be derived from the gender-based comparison that excluded the difference by types, but considering that different design types lead to different observation time, it could be seen as proper for evaluation of interior space to establish the difference of observation time by spatial types. Finally, Analysis showed the highest preference to the time '(3)'. However, obtaining information presented is the most highly effective time is '(6). Thus, the preferred time zone is different and effective, according to the results of the analysis.

Gas Typed Digital X-ray Image Sensor Using PDP Fabrication Process (PDP공정을 이용한 가스 방식의 디지털 X-ray 영상 센서)

  • Kim, Chang Man;Kim, Si Hyung;Nam, Ki Chang;Kim, Sang Hee;Song, Kwang Soup
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.322-327
    • /
    • 2012
  • Parallel-plate-type scanning sensors have been commercially used for X-ray imaging sensors. In this study, we manufactured the scan typed 1D X-ray image sensor that can be used to obtain scanning images, by using the plasma display panel (PDP) fabrication process. We fabricated drift and pixel electrodes in the glass chamber and injected Xe gas at atmospheric pressure. We evaluated the intensity of a pixel signal depending on the bias voltage on the drift electrode and investigated the characteristics of shielding effect on the single pixel using lead (Pb). The adsorption rate of X-ray photon is low (4%) on the soda lime glass (1.1mm) and the electrical signal detected on the X-ray sensor was increased in the high bias voltage. We acquired digital X-ray scanning image with our DAS (data acquisition system) and sensor scanning system.

The effects of physical factors in SPECT (물리적 요소가 SPECT 영상에 미치는 영향)

  • 손혜경;김희중;나상균;이희경
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.65-77
    • /
    • 1996
  • Using the 2-D and 3-D Hoffman brain phantom, 3-D Jaszczak phantom and Single Photon Emission Computed Tomography, the effects of data acquisition parameter, attenuation, noise, scatter and reconstruction algorithm on image quantitation as well as image quality were studied. For the data acquisition parameters, the images were acquired by changing the increment angle of rotation and the radius. The less increment angle of rotation resulted in superior image quality. Smaller radius from the center of rotation gave better image quality, since the resolution degraded as increasing the distance from detector to object increased. Using the flood data in Jaszczak phantom, the optimal attenuation coefficients were derived as 0.12cm$\^$-1/ for all collimators. Consequently, the all images were corrected for attenuation using the derived attenuation coefficients. It showed concave line profile without attenuation correction and flat line profile with attenuation correction in flood data obtained with jaszczak phantom. And the attenuation correction improved both image qulity and image quantitation. To study the effects of noise, the images were acquired for 1min, 2min, 5min, 10min, and 20min. The 20min image showed much better noise characteristics than 1min image indicating that increasing the counting time reduces the noise characteristics which follow the Poisson distribution. The images were also acquired using dual-energy windows, one for main photopeak and another one for scatter peak. The images were then compared with and without scatter correction. Scatter correction improved image quality so that the cold sphere and bar pattern in Jaszczak phantom were clearly visualized. Scatter correction was also applied to 3-D Hoffman brain phantom and resulted in better image quality. In conclusion, the SPECT images were significantly affected by the factors of data acquisition parameter, attenuation, noise, scatter, and reconstruction algorithm and these factors must be optimized or corrected to obtain the useful SPECT data in clinical applications.

  • PDF

INTRODUCTION OF COMS IDACS SYSTEM FOR METEOROLOGCIAL AND OCDAN MISSION

  • Lim, Hyun-Su;Park, Durk-Jong;Koo, In-Hoi;Kang, Chi-Ho
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.67-70
    • /
    • 2006
  • KARI is developing Image Data Acquisition and Control System (IDACS) for pre-processing meteorological and ocean data acquired on geostationary orbit. This paper describes the functions and architecture of IDACS and gives its operation policy including backup operation to overcome limitation of single-configured antenna system. The COMS IDACS provides the capability to receive the raw sensor data and disseminate processed MI data to users via a satellite. From the processed image data, users can produce a set of meteorological and ocean products for a wide range of applications. Most of IDACS subsystems are being developed by Korean technologies and experience acquired from previous projects. In case of COMS geometric correction software module, as it is closely dependent on the characteristics of imagers and spacecraft bus system, it is being co-developed with overseas prime contractor who develops spacecraft bus system.

  • PDF

Relationship between Forest Stands Characteristics and NASA/JPL AIRSAR Polarimetric Data Over Mountainous Terrain

  • Kim, Du-Ra;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.435-440
    • /
    • 2002
  • The objective of this study is to analyze the relationship between polarimetric radar backscatters and stand characteristics over the mountainous forest area. L- and P-band full polarimetric airborne SAR data obtained in September 2000 were processed to compare with forest stand maps and ground collected stand variables. After the geometric registration of SAR image, mean radar backscatters were extracted for those ground plots where the stand parameters, such as tree height, DBH, and basal area, were measured during and after the SAR data acquisition. Preliminary analysis was focused on the topographic influence of radar backscattering under the homogeneous forest stand condition. Topographic effects, assessed by the local incidence angles, were different obvious in L-band data while it was not clear with P-band data.

  • PDF

Image Segmentation based on Statistics of Sequential Frame Imagery of a Static Scene (정지장면의 연속 프레임 영상 간 통계에 기반한 영상분할)

  • Seo, Su-Young;Ko, In-Chul
    • Spatial Information Research
    • /
    • v.18 no.3
    • /
    • pp.73-83
    • /
    • 2010
  • This study presents a method to segment an image, employing the statistics observed at each pixel location across sequential frame images. In the acquisition and analysis of spatial information, utilization of digital image processing technique has very important implications. Various image segmentation techniques have been presented to distinguish the area of digital images. In this study, based on the analysis of the spectroscopic characteristics of sequential frame images that had been previously researched, an image segmentation method was proposed by using the randomness occurring among a sequence of frame images for a same scene. First of all, we computed the mean and standard deviation values at each pixel and found reliable pixels to determine seed points using their standard deviation value. For segmenting an image into individual regions, we conducted region growing based on a T-test between reference and candidate sample sets. A comparative analysis was conducted to assure the performance of the proposed method with reference to a previous method. From a set of experimental results, it is confirmed that the proposed method using a sequence of frame images segments a scene better than a method using a single frame image.

Registration Method between High Resolution Optical and SAR Images (고해상도 광학영상과 SAR 영상 간 정합 기법)

  • Jeon, Hyeongju;Kim, Yongil
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.5
    • /
    • pp.739-747
    • /
    • 2018
  • Integration analysis of multi-sensor satellite images is becoming increasingly important. The first step in integration analysis is image registration between multi-sensor. SIFT (Scale Invariant Feature Transform) is a representative image registration method. However, optical image and SAR (Synthetic Aperture Radar) images are different from sensor attitude and radiation characteristics during acquisition, making it difficult to apply the conventional method, such as SIFT, because the radiometric characteristics between images are nonlinear. To overcome this limitation, we proposed a modified method that combines the SAR-SIFT method and shape descriptor vector DLSS(Dense Local Self-Similarity). We conducted an experiment using two pairs of Cosmo-SkyMed and KOMPSAT-2 images collected over Daejeon, Korea, an area with a high density of buildings. The proposed method extracted the correct matching points when compared to conventional methods, such as SIFT and SAR-SIFT. The method also gave quantitatively reasonable results for RMSE of 1.66m and 2.45m over the two pairs of images.

A New 3D Active Camera System for Robust Face Recognition by Correcting Pose Variation

  • Kim, Young-Ouk;Jang, Sung-Ho;Park, Chang-Woo;Sung, Ha-Gyeong;Kwon, Oh-Yun;Paik, Joon-Ki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1485-1490
    • /
    • 2004
  • Recently, we have remarkable developments in intelligent robot systems. The remarkable features of intelligent robot are that it can track user, does face recognition and vital for many surveillance based systems. Advantage of face recognition when compared with other biometrics recognition is that coerciveness and contact that usually exist when we acquire characteristics do not exist in face recognition. However, the accuracy of face recognition is lower than other biometric recognition due to decrease in dimension from of image acquisition step and various changes associated with face pose and background. Factors that deteriorate performance of face recognition are many such as distance from camera to face, lighting change, pose change, and change of facial expression. In this paper, we implement a new 3D active camera system to prevent various pose variation that influence face recognition performance and propose face recognition algorithm for intelligent surveillance system and mobile robot system.

  • PDF