• 제목/요약/키워드: illuminator

검색결과 59건 처리시간 0.025초

지하 역사 LED조명기구의 적용에 대한 경제성 분석 (The economical efficiency analysis of LED illuminator application at subway station)

  • 김윤식;심재석;이기승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1868-1872
    • /
    • 2010
  • The LED illuminator has merits that it has low power consumption, long life and emits low Co2 gas. As it has many merits in comparison with existing illuminator it is a realistic alternative. but its possession in illuminator market shows slow increasement unexpectedly. Because its price is very high only low power consumption can not keep pace with economical efficiency. In this paper I analyzed economical efficiency about LED illuminator when it is applied at subway station.

  • PDF

방범·방재 기능을 갖는 에너지 절약형 조명기기 구현 (The implement of energy saving illuminator with a function of crime and fire prevention)

  • 한영오
    • 한국전자통신학회논문지
    • /
    • 제5권3호
    • /
    • pp.339-343
    • /
    • 2010
  • 본 연구에서는 방범방재 기능을 갖는 에너지 절약형 조명기기를 개발하였다. 개발된 조명기기와 관리실을 지그비 무선통신으로 연결하여 조명기기에서 획득된 정보를 전송할 수 있어 편리하게 모니터링이 가능하다. 본 조명기기를 교실 또는 사무실 내부에 여러 개의 일반 형광등과 병행하여 1개만 설치하면 학교 또는 일반 건물을 위한 저비용 방범방재 및 에너지절약형 무선 네트워크 시스템 구축이 가능하다.

Intelligent Lighting Control using Wireless Sensor Networks for Media Production

  • Park, Hee-Min;Burke, Jeff;Srivastava, Mani B.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제3권5호
    • /
    • pp.423-443
    • /
    • 2009
  • We present the design and implementation of a unique sensing and actuation application -- the Illuminator: a sensor network-based intelligent light control system for entertainment and media production. Unlike most sensor network applications, which focus on sensing alone, a distinctive aspect of the Illuminator is that it closes the loop from light sensing to lighting control. We describe the Illuminator's design requirements, system architecture, algorithms, implementation and experimental results. The system uses the Illumimote, a multi-modal and high fidelity light sensor module well-suited for wireless sensor networks, to satisfy the high-performance light sensing requirements of entertainment and media production applications. The Illuminator system is a toolset to characterize the illumination profile of a deployed set of fixed position lights, generate desired lighting effects for moving targets (actors, scenic elements, etc.) based on user constraints expressed in a formal language, and to assist in the set up of lights to achieve the same illumination profile in multiple venues. After characterizing deployed lights, the Illuminator computes optimal light settings at run-time to achieve a user-specified actuation profile, using an optimization framework based on a genetic algorithm. Uniquely, it can use deployed sensors to incorporate changing ambient lighting conditions and moving targets into actuation. Experimental results demonstrate that the Illuminator handles various high-level user requirements and generates an optimal light actuation profile. These results suggest that the Illuminator system supports entertainment and media production applications.

Reflective Fourier Ptychographic Microscopy Using Segmented Mirrors and a Mask

  • Ahn, Hee Kyung;Chon, Byong Hyuk
    • Current Optics and Photonics
    • /
    • 제5권1호
    • /
    • pp.40-44
    • /
    • 2021
  • In this paper, LED arrays with segmented mirrors and a mask are presented as a new dark-field illuminator for reflective Fourier ptychographic microscopy (FPM). The illuminator can overcome the limitations of the size and the position of samples that the dark-field illuminator using a parabolic mirror has had. The new concept was demonstrated by measuring a USAF 1951 target, and it resolved a pattern in group 10 element 6 (274 nm) in the USAF target. The new design of the dark-field illuminator can enhance competitiveness of the reflective FPM as a versatile measurement method in industry.

광파이버 일루미네이터의 2층구조형 LED 집광판 설계 (Design of a Light Collector with Two-story LED Mounting Holder for a Fiber-optic Illuminator)

  • 김완호;박준석;여인선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.255-258
    • /
    • 2001
  • This paper proposes a new structure of a fiber-optic illuminator using high Lux RGB LEDs. A simulation program, LightTools, is used for the verification of the model. An LED mounting holder containing 74 RGB LEDs is used as a basic part of its light collector. Since the light output level of current LED lamps is still far below that of conventional lamps, it is required to double the right output in order to replace a conventional illuminator with a halogen lamp. An additional cone-type reflector is installed hemispherically and the resulting structure comprises a basic collector unit. To further increase the output two collector units are connected together in series. As the result, the light output increases nearly 70% with compared to a collector with a basic structure. The system efficiency can be increased more than 8 times with compared to conventional one.

  • PDF

방열판 불량품 추출을 위한 식별 시스템 구현 (Implementation of recognition system on extracting inferior goods of radiation fin)

  • 심우성;허도근;이용식
    • 제어로봇시스템학회논문지
    • /
    • 제6권1호
    • /
    • pp.91-97
    • /
    • 2000
  • In this paper, the illuminator is designed to recognize the shape and the existence of holes of radiation fin in the point that the light reflection characteristics are different according to the roughness of the material. The threshold value, the positions of holes and the black pixel nembers in the positon are obtained under the illuminator, in accordance with the reference image, by applying binary conversion and hole segmentation algorithm, as they are suggested in this paper, The existence and shape of hole are recognized by calculating the distance and feature value in the test image, which is obtained from the parameters of reference image. It is programmed to apply to GUI(Graphic User the Interface) in windows. More than 98% of recognition rate is shown, as it is applied to three different sizes of the radiation fin.

  • PDF

전력선 모뎀을 이용한 조명기기 제어연구 (A Study On Controlling An illuminator Using Power-Line Modem)

  • 최현철;김희식;김웅찬;이재황
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.129-129
    • /
    • 2000
  • This paper describes the concept and method of Controlling an illuminator using Power-Line Modem. Nowadays it is being studied and developed the Power-Line communication. The communication using Power-Line can realize Building-Automation and Home-Automation easily and chiefly. Because it has no need constructing an additional equipment. In this study it is used The Power-Line Modem, illuminators and microcontrollers which enable RS-232C serial communication.

  • PDF

눈의 광피로회복시간 검사를 위한 도구의 탐색 (Investigation of Instrument for Photostress Recovery Time Test in the Eye)

  • 김상엽;문병연;조현국
    • 한국안광학회지
    • /
    • 제18권2호
    • /
    • pp.193-196
    • /
    • 2013
  • 목적: 눈의 광피로회복시간(photostress recovery time; PSRT) 검사를 위해 직상검안경을 대체할 수 있는 도구를 탐색해보고자 하였다. 방법: 단안 최대교정시력이 0.8~1.2인 남녀 48명(평균연령 22.88세, 96안)을 대상으로 직상검안경, 투광기, 펜라이트, 카메라 플래쉬를 사용하여 PSRT 검사를 실시하였다. 결과: 직상검안경, 투광기, 펜라이트, 카메라 플래쉬로 측정된 평균 PSRT는 각각 $27.90{\pm}18.40$초, $23.73{\pm}12.99$초, $21.31{\pm}15.57$초, $18.98{\pm}11.64$초로 측정되었다. 두 눈 중 교정시력이 1.0 이상인 눈과 1.0 미만인 눈 간의 PSRT 차이는 없었다. 우위안과 비우위안 간의 PSRT 차이도 없었다. 결론: 투광기가 직상검안경과 가장 유사한 도구로 나타났으나, 카메라 플래쉬와 펜라이트도 PSRT 검사에 유용한 것으로 판단되었다.

유방촬영시 관찰조건에 따른 임상영상평가 (Evaluation of Clinical Image on Observational Condition in Mammography)

  • 김미현;김창복;지연상;동경래
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.89-95
    • /
    • 2010
  • High contrast and high resolution are the most important factors for examining mammography images. Despite of the inconveniences of screen-film, most clinics still prefer them to computed radiography(CR) and direct radiography(DR). The reading of screen-film mammography images is influenced by the brightness from the X-ray illuminator, the exam room and incoming light from outside sources. Therefore, a comparative analysis on the results of mammo phantom images would be variated by the changes in the reading environment. There was no influence on reading results from the examiners close distance eyesight(p > 0.05); however, reading of micro lesions improved with greater darkness in the X-ray film reading room and the brightness of the X-ray illuminator(p < 0.05). Also, observation of fiber and mass images were maximized at a distance of 50 cm from the reader. Now, it is possible to observe these small classification groups using a magnifying glass without being physically close to the image. For the image of mammography, obtaining high quality images is important but in order to get an accurate clinical lesions of the reading also needs to be considered the optimal environmental factors.

  • PDF

영상조명용 144[W] LED 스폿 등기구 개발에 관한연구 (A Study on the Development of LED Spot Luminaire for Image Lighting)

  • 이장원;임지원
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.271-276
    • /
    • 2010
  • 본 연구에서는 무대 방송용 LED 스폿 조명기구를 자체적으로 설계, 제작하여 조도, 배광 및 색온도를 측정하였으며, 동일한 피사체를 LED 조명과 텅스텐 할로겐 조명을 번갈아 설치하여 인물의 영상을 카메라로 촬영한 영상을 비교하여 LED 조명기구의 대체 가능성을 연구하였다. 촬영한 피사체를 분석한 결과 LED 144[W] 조명기구가 텅스텐 할로겐 1[kW] 조명기구보다 더 영상이 밝기와 색감 면에서 더 우수하였다. 144[W] LED조명기구와 텅스텐 할로겐 1[kW] 조명기구의 사용 에너지를 측정한 결과 동일 조도기준으로 LED가 80[%] 이상의 에너지 절약효과가 있는 것으로 나타났다. 할로겐 텅스텐 1[kW] 조명기구와 LED 144[W] 조명기구의 배광과 조도 분포를 비교 검토한 결과 피사체를 집중적으로 조명하는 경우, 피조면의 조도가 높아 효과적인 조명이 가능하다. 6[m]정도 천고의 공연장이나, 스튜디오에서는 LED144[W] 조명기구는 조도 문제가 없어, 기존의 텅스텐 할로겐 1[KW] 조명기구를 1:1로 대체하는 것이 가능하다.