협조된 SPD시스템에서 접속선의 길이가 에너지협조에 미치는 영향 (Influences of the Length of Connecting Leads on the Energy Coordination in Coordinated SPD Systems)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.91-98
    • /
    • 2014
  • For the purpose of designing and applying the optimum surge protection scheme, multi-stage coordinated surge protective device(SPD) system is suitable to successfully fulfill its tasks; first, to divert a large amount of the transient energy, second, to clamp the overvoltage to the level below the withstand impulse voltage of the equipment to be protected. The length of SPD connecting leads shall be as short as possible. Long connecting leads will degrade the protection effect of SPDs. In this paper, the influences of the length of connecting leads on the energy sharing in a coordinated SPD system were investigated experimentally, and the simulation of determining the energy sharing and protection voltage level of each SPD depending on the length of connecting leads was carried out by using P-spice program. It was confirmed that the protection voltage level and energy sharing in coordinated SPD systems are strongly influenced by the length of connecting leads.

345kV 승압용 변전소의 뇌격에 의한 이상전압 해석 (Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer)

  • 조만영;신호전;허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.

GIS 절연진단센서 설계와 연면방전에 따른 방사전자파 특성 (A Design of Insulted Diagnosis Sensor and the Characteristics of Frequency Spectrum from the Radiated Electromagnetic Waves according to Surface Discharge)

  • 박숭규;최은혁;이광식
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.27-34
    • /
    • 2012
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5GHz to 15GHz with the stop band from 0.5GHz to 10.7GHz for VSWR<2. Form results of this study, The antenna is will play an important role for the senser for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

저대역 센서 네트워크 기반의 양방향 보안등 관제 시스템 개발 (Development of a Bi-Directional Security Light Control System based on Low-Bandwidth Wireless Sensor Network)

  • 이호근;이상호;이석규;최정원
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.58-66
    • /
    • 2010
  • This paper shows an implementation and management result of wireless networks based security light control system, which performs a great role in protection of pedestrians and prevention of crime. Conventional security light units have severe limits in confirmation and inspection of security light unit failure, like wilful damage by someone or failure by influence of other equipment or failure by spontaneous heat-increase, and so on. In addition, local government offices are responsible for maintenance of security light units and as a matter of fact, most of civil complaints are about security light units. It is an obvious that the existing security light maintenance system reaches the limit and the security light maintenance problem is a difficulty of local government. Therefore, efficient security light control system is needed, which enables central control and intelligent maintenance. Moreover, the system has to be easy to control and has to be stable. In this study, wireless sensor network based security light control system is implemented, which is independent of programming language and platform, and which is simple to control and extend the system. The proven protocols, HTTP and SOAP, are utilized in order to improve the system reliability. This paper shows the excellence of our proposed system by implementing and operating it in real environment.

전국 해안지역의 오손분포도 산정에 관한 연구 (A Study on the Contamination Criterion Map of Seashore Areas in Korea)

  • 김준일;김동명
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.89-96
    • /
    • 2008
  • 삼면이 바다로 둘러 싸여 있는 우리나라는 계절풍, 해풍에 의한 염분이 포함된 수분과 중화학공업에 따른 매연, 분진이 배전설비의 표면에 부착되어, 설비의 열화로 인한 정전이 발생할 가능성이 크므로, 염분에 의한 오손등급을 평가하여 설비운영에 활용함으로써, 정전을 예방하고 정전 관련 민원을 최소화할 필요가 있다. 또한, 최근에는 이상 기상 현상으로 인해 과거에 예기치 못한 자연재해가 발생하고 있으므로, 이에 대한 기후조건과 지형자료 등을 바탕으로 새로운 오손분포 산정 알고리즘을 개발하고, 오손분포 도면을 제작하여, 이를 해안지역의 배전설비 설계에 적용하는데 본 연구의 목적이 있다.

단결정 성장을 위한 자동화 설비 시스템 개발 (Development of Auto- Equipment System for Single Crystalline growth)

  • 조현섭
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.15-19
    • /
    • 2002
  • 본 연구는 직류모터를 이용한 단결정 성장제어 시스템의 개발에 관한 것이다. 수동동작에서 샘플링된 매 시간에서의 변위값들을 일련의 명령어로 변환하여 컴퓨터의 제어 신호로서 직류모친의 위치를 조작하여 동작하도록 하는 것이다. 실제 실험에 있어서 기술상의 문제였던 가스의 정밀조정이 가능하였고 조작이 간편하여 사용상의 편리성을 얻을 수 있었다. 또한 자동 가스 조절용 직류모터의 실시간 모니터링 시스템을 연구, 개발함으로써 제품의 품질을 향상 시 킬 수 있었고, 단결정 제조 설비의 개발 또한 용이 할 것으로 사료된다.

배전용 변압기를 통하여 저압 전원선으로 전파되는 뇌서지 (Lightning Surges Transferred to Low-voltage AC Power Lines through Distribution Transformers)

  • 이복희;이동문;이수봉
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.94-99
    • /
    • 2003
  • 정밀하고 소형화된 전자기기 사용의 증가로 인한 전원공급의 질적 향상에 대한 필요성이 강하게 증가하고 있다. 저압전원 배전계통에서의 과도 과전압은 직격 또는 유도뢰에 의해 유도되어지고, 가정, 사무실, 공장 등의 자동화시스템이나 병원설비와 같은 중요한 시스템의 손상이나 고장의 원인이 되고 있다. 본 논문에서는 임펄스 발생기를 이용하여 배전용 변압기를 거쳐 저압 전원시스템으로 이행되는 뇌과전압의 양상에 대하여 실험적으로 조사하였다. 배전용 변압기의 1차측에 설치한 피뢰기와 수용가측 추가접지는 저압 전원시스템으로 이행되는 뇌서지전압의 제한에는 크게 기여하지 않았다.

배전계통의 순시전압변동에 의한 수용가측 영향의 현황 분석 (Present State Analysis of Customers' Effect in Power Distribution System by Momentary Voltage Variation)

  • 김재철;윤상윤;오정환;임성정
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.37-46
    • /
    • 1998
  • 본 논문에서는 배전계통에서의 순시전압변동에 의한 수용가측 영향의 현황을 분석하였다. 전력품질에 관한 수용가의 인식은 점차적으로 증대하고 있으며 무엇보다도 전압크기의 품질은 수용기측에 직접적인 영향을 줄 수 있으므로 가장 중요한 전력품질 문제이다. 특히, 자동화공정이 발달함에 따라 순시전압변동은 전자장비, 컴퓨터, 전자개폐기 둥의 민감부하를 가동정지 시키는 심각한 결과를 초래하고 있다. 본 논문에서는 순시전압변동에 의한 수용가측 설비의 정지율을 분석하기위해 전기적 외란에 민감한 부하에 대한 실험을 통해 부하별 CBEMA 곡선과 부하별 누적 CBEMA곡선을 제시하였다. 또한 수용가측 인식실태를 파악하기 위해 "전력품질에 관한 여론조사"를 실시하였으며 그 결과를 수록하였다.

  • PDF

지중방전현상에 의한 접지시스템의 써지 임피던스의 저감 (The Decreasing of Surge Impedance of Grounding System by using Discharge)

  • 정재기;강지원;양병모;김홍필
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.55-61
    • /
    • 1998
  • 일반적으로 접지시스템에서 접지저항계산은 저주파수의 전원이 대지에 인가될 때 발새외는 대지전위상승을 측정하여 계산한다. 그러나 뇌격과 써지 엄펄스와 같은 고주파수에 해당하는 전원에 대해서는 현재의 접지 시스템에서 고려하고 있지 않기 때문에 전기설비에 매우 큰 영향을 미칠 우려가 있다. 그래서 이 논문에 서는 뇌격이 전극봉에 인가되었을 때 발생되는 접지 임피던스의 과도현상을 실험하였다. 그리고 이 실험 결과는 이론적 해석과 잘 일치하였으며 지중방전현상이 임펄스 임피던스 저감에 영향올 미친다는 사실을 확인 할 수 있었다.

  • PDF

부하변동 시의 고조파제거 및 절전기 개발 (Development of the Harmonics Reduction and Energy Saving Equipment in Variable Loads)

  • 송영복;조용현;최동진
    • 조명전기설비학회논문지
    • /
    • 제20권6호
    • /
    • pp.87-95
    • /
    • 2006
  • 본 연구에서는 부하의 변동 시에 고품질의 전력을 얻기 위하여 중성선과 전력선에 흐르는 각각의 영상 전류 성분과 제3고조파 전류 성분을 감소시킬 수 있는 Zig-Zag 변압기, 그리고 그 변압기의 2차측에 3상 브리지 정류기와 케패시터로 구성된 단상 능동 필터를 제작하였다. 이 단상 능동 필터를 변압기와 비선형 부하에 연결시켜 각 상에 보상 전류를 발생시킴으로써, 비선형 부하로 인하여 발생하는 제3고조파 성분을 감소시킬 수 있었다.