Characteristics of Autoignited Laminar Lifted Flames in Heated Coflow Jets of Carbon Monoxide/Hydrogen Mixtures (일산화탄소/수소 혼합기의 가열된 동축류 제트에서 자발화된 층류 부상화염의 특성)

  • Choi, Byung-Chul;Chung, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.639-646
    • /
    • 2012
  • The characteristics of autoignited lifted flames in laminar jets of carbon monoxide/hydrogen fuels have been investigated experimentally in heated coflow air. In result, as the jet velocity increased, the blowoff was directly occurred from the nozzle-attached flame without experiencing a stabilized lifted flame, in the non-autoignited regime. In the autoignited regime, the autoignited lifted flame of carbon monoxide diluted by nitrogen was affected by the water vapor content in the compressed air oxidizer, as evidenced by the variation of the ignition delay time estimated by numerical calculation. In particular, in the autoignition regime at low temperatures with added hydrogen, the liftoff height of the autoignited lifted flames decreased and then increased as the jet velocity increased. Based on the mechanism in which the autoignited laminar lifted flame is stabilized by ignition delay time, the liftoff height can be influenced not only by the heat loss, but also by the preferential diffusion between momentum and mass diffusion in fuel jets during the autoignition process.

An experimental study on the fire hazard of Sheath Heater (시즈히터의 화재위험성에 관한 실험 연구)

  • Kim, Hakjoong
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.511-517
    • /
    • 2014
  • Recently, the fire by sheath heater has been occurred frequently on winter season. The sheath heater has simple internal structure and boils water simply. Therefore, the use of sheath heater has been increased. In this study, found the fire hazard property of sheath heater from understanding the fire mechanism through the experiment to get the measure for decreasing the occurrence of fire. For the analysis of the fire hazard property of the sheath heater, performed the test of temperature change and ignition temperature by using current product. On the result of test, the sheath heaters are the most dangerous appliance to arise fire. Water temperature controller attached to sheath heater is not sufficient to prevent overheating it. The sheath heater should have level switch of water and temperature controller for heater itself to shut off the power supply. Because the cause of fire by sheath heater is overheating itself in the situation of lack water.

Research Activities on Subsystem Technologies of PDE Propulsions (PDE 추진기관 부체계 기술 연구 동향)

  • Jin, Wan-Sung;Kim, Ji-Hoon;Hwang, Won-Sub;Kim, Jeong-Min;Choi, Jeong-Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.8
    • /
    • pp.712-721
    • /
    • 2015
  • Pulse Detonation Engine (PDE) has been considered as a future propulsion system for broad range of operation and higher thermal efficiency. Various subsystem technologies have been studied for more than decade to improve the performance of the potential system. New valve systems has been developed for the stable operation at high frequency including inflow-driven valve, rotary valve and valveless system. To foster the detonation initiation with a little ignition energy, plasma ignition method and DDT (deflagration to detonation transition) acceleration method such as swept ramp mechanism have been studied. Fluidic nozzle system and other nozzle system are the ongoing research topics to maximize the propulsion performance of the PDE. Present paper introduces the state of the art of PDE subsystem technologies developed in recent years.

Fabrication and Thermophysical Properties of Nickel-coated Aluminum Powder by Electroless Plating (비전해 방법을 이용한 니켈 코팅 알루미늄 분말 제조 및 열물성 평가)

  • Lee, Sanghyup;Lim, Jihwan;Noh, Kwanyoung;Yoon, Woongsup
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.4
    • /
    • pp.9-17
    • /
    • 2014
  • In this study, in order to improve the ignitability of high energy aluminum powder, natural oxide films (alumina) were chemically removed, and instead nickel coat was applied. We used an electroless plating for nickel coating and confirmed quantitatively and qualitatively a time-dependent degree of nickel coating through analysis of surface by SEM/EDS. We also conducted element analysis by XRD and thermal properties by TGA/DSC in air oxidizer environment. There results explained the ignition enhancement mechanism of the nickel-coated aluminum powder in air. The difference between coated and un-coated aluminum powder, the effectiveness of coated powder has better ignitability.

Experimental Study on the Stimulating Effect of Commercial Moxa Combustion through the Measurement of Temperature - Focused on ascending temperature gradient and effective stimulating period - (온도 측정을 통한 상용 쑥뜸의 자극효과에 대한 실험적 연구 - 승온속도 및 유효자극기를 중심으로 -)

  • Lee, Geon-Mok;Lee, Gun-Hyee;Lee, Seung-Hoon;Yang, Myung-Bok;Go, Gi-Deok;Seo, Eun-Mi;Jang, Jong-Deok;Hwang, Byung-Chan
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.64-76
    • /
    • 2002
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion objectively and to be used as the quantitative data for developing the new thermal stimulating treatment by observing the combustion characteristics of commercial moxaes. Methods : We have selected two types(large-size moxa A(LMA), large-size moxa B(LMB)) among large moxaes used widely in the clinic. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results : 1. The ascending temperature gradient measured in the central point of non-contacted surface was fastest, the average ascending temperature gradient of both moxaes was $0.0384^{\circ}C/sec$, $0.0123^{\circ}C/sec$ respectively, 3.1 times faster in LMA. The maximum ascending temperature gradient was also about 2.9 times faster in LMA. The time required for the maximum ascending temperature gradient from ignition was 254sec, 411sec respectively. 2. The minimum descending temperature gradient in the retaining period was $-0.0250^{\circ}C/sec$, $-0.0090^{\circ}C/sec$ respectively and the average descending temperature gradient was $-0.0160^{\circ}C/sec$, $-0.0037^{\circ}C/sec$ respectively on the non-contact surface. 3. On the basis of the non-contact surface($A_I$), the time at which the effective stimulus period began to occur was about 264sec, 796sec respectively after an ignition, the time at which the maximum temperature began to occur was about 373sec, 1323sec respectively after an ignition, and the maximum temperature was $0.9^{\circ}C$ higher in LMA. The maximum ascending temperature gradient was also about 4.2 times faster in LMA. Conclusion : It was thought that not only the figure of moxicombustion device, but also the form and size of moxa had influence on the combustion characteristics deciding the performance of stimulus seriously.

  • PDF

Fire Mechanism in Power Connection Points of Outlets and Suggestion of a New Identification Method (콘센트 전원 접속구 화재 발생 메커니즘 고찰과 새로운 감식 방법 제시)

  • Park, Jin-Young;Bang, Sun-Bae;Eun, Hee-Rim;Oh, Se-Hyeok;Lee, Yoo-Bin;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.76-84
    • /
    • 2020
  • Most outlet fires occur around plug pins and plug pin receivers. However, no research has been conducted on ignitions at power connection points. This study confirms the possibility of ignition after incomplete connection, using a stranded wire, to the power connection point of an outlet. The experiment was divided into basic and reproducing experiments. The basic experiment confirmed the possibility of ignition according to the number of wire strands connected to the power connection point, and it identified the characteristics of the residue after the fire. In the reproducing experiment, lamps, vacuum cleaners, and heaters were connected to an outlet to check if the ignition at the connection advanced into a fire. The fire advanced due to the heat and arc generated at the connection point, and partial losses were identified in the U-type holder and clip. Accordingly, the results demonstrate that a fire may occur when the stranded wire is incompletely connected to the outlet. Moreover, it was confirmed that the cause of a fire can be determined based on the characteristics of the residue.

Comparison of DME HCCI Operating Ranges for the Thermal Stratification and Fuel Stratification based on a Multi-zone Modeling (Multi-zone 모델링을 통한 온도성층화와 농도성층화가 존재하는 DME HCCI 엔진의 운전영역에 관한 수치해석연구)

  • Jeong, Dong-Won;Lim, Ock-Taeck
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.35-41
    • /
    • 2011
  • This work investigates the potential of in-cylinder thermal stratification and fuel stratification for extending the operating ranges in HCCI engines, and the coupling between thermal stratification and fuel stratification. Computational results areemployed. The computations were conducted using both a custom multi-zone version and the standard single-zone version of the Senkin application of the CHEMKINII kinetics rate code, and kinetic mechanism for di-methyl ether (DME). This study shows that the potential of thermal stratification and fuels stratification for extending the high-load operating limit by a staged combustion event with reduced pressure-rise rates is very large. It was also found that those stratification offers good potential to extend low-load limit by a same mechanism in high-load. However, a combination of thermal stratification and fuel stratification is not more effective than above stratification techniques for extending the operating ranges showing similar results of fuel stratification. Sufficient condition for combustion (enough temperature for) turns misfire in low-load limit to operate engines, which also leads to knock in high-load limit abruptly due to the too high temperature with high. DME shows a potential for maximizing effect of stratification to lower pressure-rise rate due to the characteristics of low-temperature heat release.

A study on the analysis of domestic gas explosion (실내가스폭발 해석에 관한 연구)

  • Kim Sang Sub;Cha Jae Ou
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.24-29
    • /
    • 2003
  • Numerical analysis was conducted to predict the damage of indoor gas explosion for the propagation of explosion flame. Indoor gas diffusion distribution due to gas leakage was obtained by diffusion equation that adopted initial conditions from reference. Enthalpy of each gas-mixture ratio and reduced mechanism was applied to calculate flame temperature, and laminar combustion velocities with the variant of each gas concentration from reference were applied to the gas mixture. Turbulent combustion velocity was modeled by coupling of turbulent energy and laminar combustion velocity in k-$\epsilon$ model. For the analysis of flame propagation cartesian and cylindrical coordinate were used to indoor position and flame propagation respectively. The study analyzes the cause of pressure rising with the variation of flame propagation by glass damage, and the result shows that indoor pressure rising with ignition position varies window dimension.

  • PDF

Damage Effect on Glass Fibre Reinforced Plastics under Airflow by a Continuous Wave Laser (연속발진 레이저에 의한 공기 유동에 노출된 유리섬유 강화 플라스틱 손상효과)

  • Lee, Kwang Hyun;Shin, Wan-Soon;Kang, Eung-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.293-299
    • /
    • 2015
  • We analyzed the damage effect on Glass Fibre Reinforced Plastics(GFRP) under air flow by irradiation of continuous wave near-IR laser. Damage process and temporal temperature distribution were demonstrated and material characteristics were observed with laser intensity, surface flow speed and angle. Surface temperature on GFRP rapidly increased with laser intensity, and the damaged pattern was different with flow characteristics. In case of no flow, penetration on GFRP by burning and flame generation after laser irradiation was appeared at once. GFRP was penetrated by the heat generated from resin ignition. In case of laser irradiation under flow, a flame generated after burning extinguished at once by flow and penetration pattern on GFRP were differently shown with flow angle. From the results, we presented the damage process and its mechanism.

Development of Non-Electric and Delay Explosive Bolt (비전기식 지연형 폭발볼트 개발)

  • Lee YeungJo;Kim DongJin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.92-95
    • /
    • 2005
  • The present work has been developed the type of non-electric and delay explosive bolt which does not need power supply device and has the delay function in the operation of the explosive bolt. Separation device system could be minimized because of non-electric power supply system. In order to prove the mechanism of operation, the present work used to ignite the initiator the power of air resistance caused front aviation object. we can be founded from the present work that the changes in the operation load influence directly the ignition of the initiator. The design of non-electric and delay explosive bolt is the most suitable the separation system necessary to reduce the velocity of aviation object and safe landing of parachute system.

  • PDF