• Title/Summary/Keyword: ignition hazard

Search Result 84, Processing Time 0.027 seconds

Onset and Propagation of Hydrogen-Air Premixed Flame with Multiple Kinetics (다단 반응을 고려한 수소-공기 예혼합 화염의 발생 및 전파)

  • Han Cho Young;Baek Seung Wook
    • Journal of computational fluids engineering
    • /
    • v.9 no.1
    • /
    • pp.25-33
    • /
    • 2004
  • Flame onset and propagation within hydrogen premixed gas mixture are numerically investigated in an rectangular enclosure. A detailed chemistry for hydrogen reaction is applied to anticipate the thermochemical behavior of intermediate species appropriately. To facilitate computation, 10 species and 16 elementary reaction steps for hydrogen combustion are taken into account. On the basis of 30% of hydrogen concentration in hydrogen-air mixture, the effects of position and quantity of ignition sources on the flame evolution are analyzed. From the simulation results, the methods to decrease the potential hazard caused by the flame propagation are suggested.

Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer (모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구)

  • Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

Characteristic of Auto Ignition Temperature due to the Mixture Ratio of Ethylene Glycol and Water (Ethylene Glycol과 물의 혼합비에 따른 자연발화온도 특성)

  • Kim, Jung-Hun;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.24-30
    • /
    • 2016
  • Autoignition characteristic is an important factor of all combustible substances, and a critical determinant in assessing the effectiveness of fire hazard prevention. This study investigated the autoignition characteristic of mixtures of Ethylene Glycol and water using an ASTM D2155 type ignition temperature measuring apparatus. It was possible to get the minimum temperature as $434^{\circ}C$ from 100% Ethylene Glycol within range of $75{\sim}160{\mu}l$. A volume of $100{\sim}125{\mu}l$ of a mixed sample of Ethylene Glycol and water (80 : 20) was ignited at the same temperature ($434^{\circ}C$). Also it was possible to get the auto ignition temperature as $437^{\circ}C$ from a mixed sample of Ethylene Glycol and water (60 : 40) within range of $120{\sim}160{\mu}l$. The instantaneous ignition temperatures determined for $125{\mu}l$ of each of the three samples were $579^{\circ}C$, $595^{\circ}C$ and $611^{\circ}C$, respectively. Both auto ignition temperatures and instantaneous ignition temperatures were increased through the addition of water to the samples.

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

A Study on the Characteristics of Combustion for Car Interior Materials (자동차 내장재의 연소 특성에 관한 연구)

  • Kim, Young-Tak;Kim, Hae-Rim;Park, Young-Ju;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.450-455
    • /
    • 2008
  • We have carried out the test using the cone calorimeter and the smoke density chamber to evaluate the characteristics of the combustion for the car interior materials passed horizontal burning test. We have analysed many parameters related to fire hazard. These parameters are the ignition time, the heat release rate, the maximum average rate of heat emission, the flashover propensity and specific optical density. There was a significant difference in HRR and optical smoke density. The HRR was $185{\sim}446kW/m^2$ and optical smoke density was $119{\sim}1207$. Only horizontal burning test was performed to evaluate the fire hazard for the car interior materials.

  • PDF

Study on Combustion and Explosion Hazard of Rice Bran Dusts (쌀겨 분진의 연소 및 폭발 위험성에 관한 연구)

  • 이창우;현성호;이한철;허윤행
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.93-98
    • /
    • 1999
  • We had investigated combustion properties of rice bran dusts. Decomposition of rice bran dusts with temperature were investigated using DSC and the weight loss according to temperature using TGA in order to find the thermal hazard of rice bran dusts, and the properties of dust explosion in variation of their dust with the same particle size. Using Hartman's dust explosion apparatus which estimate dust explosion by electric ignition after making dust disperse by compressed air, dust explosion experiments have been conducted by varying concentration and size of rice bran dust.According to the results for thermodynamic stability of rice bran dust, there are little change of initiation temperature of heat generation and heating value for used particle size. But initiation temperature of heat generation decreased with high heating rate whereas decomposition heat increased with particle size. Average maximum explosion pressure was $10kgf/cm^2$ for 60/70 mesh and $1.5mg/cm^2$ dust concentration.

  • PDF

A Study on the Ignition and Molten Mark Analysis of Ballast for Fluorescent Lamp (형광등용 안정기의 발화 및 용융흔 분석에 관한 연구)

  • 최충석;박창수;김혁수;김향곤;정재희
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.173-177
    • /
    • 1998
  • In this paper, we reported an outbreak of fire hazard of ballast for fluorescent lamp. The surface structure and composition of ballast coil analyzed by using metallurgical microscope, scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of molten mark appeared columnar structure and void. EDX analysis indicated that the molten mark spectra were composed not only of the corresponding original spectra but also of several new lines.

  • PDF

A Study on Analysis of Characteristics Combustion of Floor Covering Materials (바닥내장재의 연소특성 분석에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong;Kim, Hyun-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we analyzed the combustion characteristics of four different floor covering materials(wood, monorium, laminatedpaper, and varnish-laminated paper) with regard to their ignitibility, thermal characteristics and flame retardancy by using an ignition temperature tester, a dual cone calorimeter, a thermogravimetric analyzer and limited oxygen index, for their fire risk assessment. According to the result, monorium had the lowest ignition temperature of $325^{\circ}C$ and the laminated paper and the varnish-laminated paper promptly ignited before 7s. Further, the wood showed the largest total heat release of $100MJ/m^2$, and the varnish-laminated paper showed the highest peak heat release rate. From the thermogravimetric analysis, it was shown that all specimens underwent rapid weight loss at $300{\sim}400^{\circ}C$. The limit oxygen indices of the laminated paper and the varnish-laminated paper were in the range of 20~21%, while it was 34% for wood. This study enabled us to confirm that wood, laminated paper and varnish-laminated paper have a relatively short ignition time and are easy to burn but they all have low heat release. In contrast, wood showed the lowest fire risk among them and had excellent flame retardancy but with high heat release.

A Fire Hazard Assessment of Interior Finish Materials (건물 내장재의 화재위험성 평가 방법)

  • 김운형
    • Fire Science and Engineering
    • /
    • v.12 no.2
    • /
    • pp.17-28
    • /
    • 1998
  • To propose a new fire hazard assessment criteria of interior finish materials, the properties and incident heat flux of interior finish materials in a compartment fires are investigated and compared by using flame spread model developed by Quintiere. The properties considered on which fire growth depend are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. ISO Room Corner Test(9705) is applied in the model and the time for total energy release rate to reach 1MW is examined. The results are compared for the 24 different materials tested by EUREFIC. Dimensionless parameter a, b and ${\gamma}$b are used to develope a new method in which fire hazard of interior finish materials can be classified resulting from correlation between b and flashover time. Results show that if b greater than about zero, flashover time in the ISO Room-Corner Test is principally proportional to ignition time only.

  • PDF

A Study on the Development of Simulating Tool for Evaluation of Electrostatic Discharge (정전기 방전 평가를 위한 간이형 도구 개발에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.15-22
    • /
    • 2011
  • Explosion and fire cause about 30 reported industrial major accidents a year by ignition source which discharge of electrostatic generated to flammable gas, vapor, dust and mixtures. It brings economically and humanly very large loss that accident was caused by fire and explosion from electrostatic discharge. Thus, it is very important that electrostatic discharge energy is to be control below not to be igniting flammable mixtures. There are two kinds of analysis model for electrostatic discharge, human body model and machine model. Human body model is available the parameter of human's electrical equivalent that capacitance is 100 pF, resistance is $1.5k{\Omega}$. To simulate and visualize the electrostatic discharge from human body need a very expensive and high voltage simulator. In this paper, we measured the value of capacitance and resistance concerned with test materials and sizing of specimen and the value of charged voltage concerned with test specimen and distance to develop an electrostatic charge/discharge simulating tool for teaching with which concerned industrial employee and students. The result of experiments, we conformed that the minimum ignition energy of methane-oxygen mixtures meets well the equation $W=1/2CV^2$, and found out that the insulating material and sizing of equivalent value having human body mode are the poly ethylene of 200 mm and 300 mm of diameter. Developed electrostatic charge/discharge simulating tool has many merits; simple mechanism, low cost, no need of electric power and so on.