• Title/Summary/Keyword: ice-2

Search Result 1,286, Processing Time 0.036 seconds

Influence of Freezing Process on the Change of Ice Crystal Size and Freeze-Drying Rate in a Model System (모델 시스템에서 동결속도에 따른 얼음 결정체의 크기 및 동결건조속도의 변화)

  • Byun, Myung-Hee;Choi, Mi-Jung;Lee, Sung;Min, Sang-Gi
    • Food Science of Animal Resources
    • /
    • v.18 no.2
    • /
    • pp.164-175
    • /
    • 1998
  • The objective of this study was to investigate the effects of freezing rate on ice crystal size and freeze-drying rate. Our experiments were carried out with self-manufactured freeze-dryer. Gelatin gels (2% w / w, 80$\times$20mm) were frozen unidirectionally (Neumann's model) from the bottom at -45, -30, -20, and -15$^{\circ}C$ and followed with freeze-drying. Under the upper conditions we measured freezing rate and the change of temperature and pressure during freeze drying. Freeze-dried gelatins were cut horizontally into 5 mm thickness from the bottom and measured their pore sizes. Also freeze-drying rate(primary drying) is estimated by measuring the temperature of sample and pressure of vacuum chamber. During freeze-drying, profiles of pressure and temperature were shown constant tendency regardless of freezing temperature and we could expect the end-point of freeze drying by considering pressure and temperature together. In temperature profiles, the point which temperature increased significantly was observed during freeze-drying. There is no relationship between freeze temperature and drying rate of primary drying in our model system. As freezing temperature increased, ice crystal size(X*) which correspond to 63.2% of cumulative frequency was increased and at the same freezing temperature ice crystal size(X*) was decreased with distance from the bottom of the sample. Freezing conditions have a strong influence on the quality of the final freeze-dried products in freeze-drying system.

  • PDF

A Study on Evaluation and Improvement of Sealing Performance of Duct Cap Assembly for Ice Dispenser By Nonlinear Contact Problem Analysis (비선형 접촉문제 해석을 통한 얼음 디스펜서 덕트 캡 조립체의 밀봉성능 평가 및 개선방안 연구)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.2
    • /
    • pp.37-46
    • /
    • 2018
  • Present research is to evaluate and improve the sealing performance of the duct cap assembly for the ice dispensers through structural analysis. The nonlinear contact problems to check the sealing performance were analyzed using ANSYS software. The results of the analyses related to the sealing performance: the displacement distribution, the contact condition between the cap-silicon and the case, and the pressure distribution on the contact surface, were examined and discussed. Based on the results of the existing design of the duct cap assembly, two cases of the design modifications to improve the sealing performance were introduced. By examining the results of the two cases, a final design improvement plan was proposed and analyzed. It is shown that the sealing performance of the proposed final design is much more favorable than the existing design. The method of structural analysis and design improvement of the duct cap assembly presented in this paper will help improve the sealing performance of the ice dispenser duct caps.

The ice features of Very Low Luminosity Objects (VeLLOs): Unveiling their episodic accretion history through the spectroscopic observation of AKARI IRC

  • Kim, Jaeyeong;Lee, Jeong-Eun;Aikawa, Yuri;Kim, Il-Seok;Lee, Ho-Gyu;Jeong, Woong-Seob;Noble, Jennifer A.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.45.3-46
    • /
    • 2018
  • Although mass accretion from the disk to the central protostar is a key process of low mass star formation, the accretion mechanism is still poorly understood. To investigate "episodic accretion", which has been suggested as an accretion mechanism in low mass star formation, we have carried out near-infrared spectroscopic observations of three very low-luminosity objects (VeLLOs) and one background source, using InfraRed Camera onboard the AKARI space telescope. The ice absorption features of $H_2O$, $CO_2$, and CO were detected around the wavelengths of 3.0, 4.26, and $4.67{\mu}m$, respectively. In addition, we revealed the XCN ice feature, which is attributed to high energy UV photons produced by the episodic burst accretion. The comparisons of the ice abundances of our targets with those of other YSOs observed previously with AKARI IRC imply that the three VeLLOs had experienced burst accretions although they are now in a very quiescent phase.

  • PDF

An experimental study on ice slurry creation by injection of an aqueous solution (수용액 분사에 의한 아이스 슬러리의 제조에 관한 실험적 연구)

  • Lee, Yong-Koo;Oh, Cheol
    • Journal of Navigation and Port Research
    • /
    • v.34 no.1
    • /
    • pp.71-75
    • /
    • 2010
  • This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by injection operating water to cooling plate. And at this experiment it used ethylene glycol-water solution and the concentration is 10 to 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank, brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter, data logger for fluid temperature measuring and a vertical circular tube with single copper plate as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 1.0 to 2.0m/s and the cooling temperature of $-17^{\circ}C$ to $-10^{\circ}C$.

The effect of pre-cooling versus topical anesthesia on pain perception during palatal injections in children aged 7-9 years: a randomized split-mouth crossover clinical trial

  • Chilakamuri, Sandeep;SVSG, Nirmala;Nuvvula, Sivakumar
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.6
    • /
    • pp.377-386
    • /
    • 2020
  • Background: To compare pain perception during palatal injection administration in children aged 7-9 years while using pre-cooling of the injection site versus application of topical anesthesia as a pre-injection anesthetic during the six months. Method: A prospective randomized split-mouth crossover trial was conducted among 30 children aged 7-9 years, who received topical application of either a pencil of ice (test group) or 5% lignocaine gel (control group) for 2 min before injection. The primary and secondary outcome measures were pain perception and child satisfaction, measured by the composite pain score and the faces rating scale, respectively. Unpaired t-test was performed to determine significant differences between groups. Results: The test group had significantly lower pain scores for self-report and behavioral measures (P < 0.0001). The changes in physiological parameters at the baseline (P = 0.74) during (P = 0.37) and after (P = 0.88) the injection prick were not statistically significant. Children felt better by the pre-cooling method (P < 0.0001). Conclusion: Ice application using a pencil of ice for 2 min reduced pain perception significantly compared to the use of a topical anesthetic. Moreover, ice application was preferred by children.

Basic Studies in Improvement of Freeze Concentration -(II) The Growth Rate and the Variety in Diameters of Ice Crystals- (동결농축(凍結濃縮)의 개선(改善)을 위한 기초적연구(基礎的硏究) -II. 빙결정(氷結晶)의 성장속도(成長速度)와 입경분포(粒徑分布)-)

  • Kong, Jai-Yul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.14 no.4
    • /
    • pp.359-364
    • /
    • 1985
  • Being used the three kinds of aqueous solution of tobacco extracts as a new experimental material, experiment and theoretical analysis are performed. Measurements are made with a apparatus designed and constructed by the author.The average diameter of the ice crystals is 0.04-0.1cm between 0.2 and $0.6^{\circ}C$ of the subcooling temperature of the solution. The growth rate of ice crystals in direction of axies A, $V_a$ is in proportion to the subcooling temperature, viz; $v_a=0.058{\Delta}t_b,\;where\;{\Delta}t_b<0.1^{\circ}C$ The growth rate of ice crystal have to be considered not only the mass diffusion and the heat transfer of rate controlling but also the process in ice crystallization. The growth rate of ice crystal is found to be independent on the concentration of the solution and a diameter of ice crystal.

  • PDF

Ice Melting Capacity Evaluation of Applicable Materials of De-icing Fluid for High Speed Railway Rolling Stock (고속철도차량용 제빙액으로의 적용가능물질에 대한 융빙성능 평가)

  • Park, Gyoung-Won;Lee, Jun-Ku;Lee, Hong-Ki
    • Applied Chemistry for Engineering
    • /
    • v.30 no.3
    • /
    • pp.384-388
    • /
    • 2019
  • In winter season, the snow and ice accretion on the bottom of the high speed railway rolling stock and boogie part has fallen at a high speed from the ballast section (gravel section for the transmission of the rolling stock load received by sleepers and fixing sleepers), causing the gravel to be scattered, thereby damaging the railway rolling stock structures and facilities. In order to solve these problems, the gravel scattering prevention net, manual de-icing, and movable hot air machine were used, but their efficiency was low. For the more efficient de-icing than ever before, an optimum material for de-icing fluid for high speed railway rolling stock was developed by evaluating the ice melting capacity, kinematic viscosity, evaporation of the material used as a chemical de-icing fluid. Four kinds of organic acid salts (sodium formate, sodium acetate, potassium formate and potassium acetate) and two different alcohols (propylene glycol, glycerol) were used as evaluation materials. Potassium formate, potassium acetate, and propylene glycol had similar ice melting capacities in the indoor test, but the propylene glycol showed the best ice melting capacity in spraying the system simulation test. This is because the kinematic viscosity of propylene glycol was 2.989029 St, which is higher than those of other materials therefore, it could stay longer on the ice and de-icing. In addition, potassium formate and potassium acetate were difficult to be used since the crystals precipitated and adversely affected the appearance of the rolling stock. The propylene glycol is the most optimum as an de-icing fluid for the high speed railway rolling stock.

Implementation of Improved Ice Particle Collision Efficiency in Takahashi Cloud Model (Takahashi 구름모형에서의 얼음입자 충돌효율 개선)

  • Lee, Hannah;Yum, Seong Soo
    • Atmosphere
    • /
    • v.22 no.1
    • /
    • pp.73-85
    • /
    • 2012
  • The collision efficiency data for collision between graupel or hail particles and cloud drops that take into account the differences of particle density are applied to the Takahashi cloud model. The original setting assumes that graupel or hail collision efficiency is the same as that of the cloud drops of the same volume. The Takahashi cloud model is run with the new collision efficiency data and the results are compared with those with the original. As an initial condition, a thermodynamic profile that can initiate strong convection is provided. Three different CCN concentration values and therefore three initial cloud drop spectra are prescribed that represent maritime (CCN concentration = 300 $cm^{-3}$), continental (1000 $cm^{-3}$) and extreme continental (5000 $cm^{-3}$) air masses to examine the aerosol effects on cloud and precipitation development. Increase of CCN concentration causes cloud drop sizes to decrease and cloud drop concentrations to increase. However, the concentration of ice particles decreases with the increase of CCN concentration because small drops are difficult to freeze. These general trends are well captured by both model runs (one with the new collision efficiency data and the other with the original) but there are significant differences: with the new data, the development of cloud and raindrop formation are delayed by (1) decrease of ice collision efficiency, (2) decrease of latent heat from riming process and (3) decrease of ice crystals generated by ice multiplication. These results indicate that the model run with the original collision efficiency data overestimates precipitation rates.

An Experimental Study on an Ice Storage System by a Two-Phase Closed Thermosyphon (2상 밀폐 서모사이폰을 이용한 빙축열 시스템의 성능)

  • Kyung, I.S.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.2
    • /
    • pp.87-96
    • /
    • 1991
  • A two-phase closed thermosyphon is applied to an ice storage system. The thermosyphon is used to freeze the water in a storage tank. The experiment has been performed to investigate the effects of the important parameters such as the quantity of the fluid filled with, the ratio of the length of the evaporator to the condenser, and the temperature and the mass flow rate of the brine. It is found that the higher thermal performance of the thermosyphon is obtained as the ratio of the length of the evaporator section to that of the condenser section is decreased and the temperature of the brine is lowered. The increase of the quantity of the working fluid also favors the performance of the system. The experimental data can be utilized for the basic design of ice storage systems with thermosyphons.

  • PDF