• Title/Summary/Keyword: ice storage

Search Result 297, Processing Time 0.034 seconds

A Study on the DSM Effect of a Refrigerant-Subcooling Refrigeration System with an Ice Storage Tank (축열조를 이용한 냉매과냉각 시스템의 전력수요관리 효과에 대한 연구)

  • Kim, Jeong-bae;Lee, Eun-Ji;Lee, Dong-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.845-851
    • /
    • 2010
  • This study was experimentally performed to find the effects of refrigerant subcooling in the refrigeration system and to propose how to get the efficient use of energy. A refrigerant-subcooling refrigeration system consisted of a typical single vapor-compression refrigeration cycle, a subcooler, and an ice storage tank. The degree of subcooling at the exit of the condenser can be increased by the heat transfer between the subcooler and the ice storage tank. The cold heat in the ice storage tank was stored by using the refrigeration cycle during night time and then used to absorb the heat from the subcooler during daytime. The cooling capacity and COP of this system were higher than those of the conventional system due to the increase in the degree of subcooling. Typically, the refrigerant-subcooling system showed superior performance to the conventional refrigeration system and would also contribute to load leveling.

An Experimental Study on the Performance Characteristics of a Refrigerant-Subcooling Refrigeration System with an Ice Storage Tank (축냉시스템을 이용한 냉매과냉각형 냉동시스템의 성능특성에 관한 실험적 연구)

  • Lee, Eun-Ji;Lee, Dong-Won;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.369-374
    • /
    • 2010
  • A refrigerant-subcooling refrigeration system consisted of a typical single vapor-compression refrigeration cycle, a subcooler, and an ice storage tank. The degree of subcooling at the exit of the condenser can be increased by the heat exchange between the subcooler and the ice storage tank. The cold heat in the ice storage tank was stored by using the refrigeration cycle during night time and then used to absorb the heat from the subcooler during daytime. The performance of the refrigerant-subcooling refrigeration system was measured by varying the degree of subcooling. In addition, the performance characteristics of the present system were compared with those of a conventional refrigeration system. The mass flow rate of the present system was higher than that of the conventional system due to the increase in the degree of subcooling. Generally, the refrigerant-subcooling system showed superior performance to the conventional refrigeration system.

Numerical Analysis for Cooling and Freezing Processes with Subcooling (과냉각을 동반한 동결과정의 수치해석)

  • Yoon, J.I.;Kim, J.D.;Kim, S.G.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.451-462
    • /
    • 1996
  • In this study, which focuses on ice storage, a fundamental study in cooling and solidification was performed, including the interesting phenomena of density inversion, supercooling and dendritic ice. A numerical study was performed for natural convection and ice formation considering existence of subcooling and dendritic ice were analyzed numerically by using finite difference method and boundary fixing method. In the mesh, the solid fraction was introduced with adding as a term to the energy conservation equation. A flow in the dendrite was modelled as a flow in a porous medium, and the momentum conservation equation was modified to incorporate resistance forces involved in flows through porous media. A numerical solution of the time dependencies of dendrite area and dense ice front was successfully obtained, and the numerical results were good agreement with experimental results. Based on this methodology, a discussion was made of phenomena and characteristics of cooling and freezing processes under various conditions.

  • PDF

Flow pattern analysis and a study on formation of slurry ice in the reversing flow (역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.202-202
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This study is experimented to observe flow pattern and formation of slurry ice in reversing flow to improve efficiency of heat transfer between fluid and freezing tube.

  • PDF

Simulation of Ice Ring Formation around Cryogenic Underground Storage Cavern using Hydro-Thermal Coupling Method (극저온 지하저장고 주변 ice ring 생성 모델링을 위한 열-수리 해석)

  • Jung Yong-Bok;Park Chan;Chung So-Keul;Jeong Woo-Cheol;Kim Ho-Yeong
    • Tunnel and Underground Space
    • /
    • v.16 no.3 s.62
    • /
    • pp.241-250
    • /
    • 2006
  • Ice ring formation, one of the core techniques in LNG storage in a lined rock cavern, is investigated through hydro-thermal coupled analysis. An ice ring acts as a secondary barrier in case of leakage of cryogenic liquid and as a primary barrier for groundwater intrusion into an LNG cavern. Therefore, the thickness and location of the ice ring are crucial factors for the safe operation of an LNG storage cavern, especially for maintaining the integrity of a primary barrier composed of concrete, PU foam, and steel membrane. Through numerical analyses, the position and thickness of the ice ring are estimated, and the temperature and groundwater level are compared with measured values. The temperature md groundwater level by numerical analyses show good agreement with the field measurements when temperature-dependent properties and phase change are taken into account. The schemes used in this paper can be applied for estimation of ice ring formation in designing a full-scale LNG cavern.

An experimental study on heat transfer characteristics in the ice storage system of ice-on-coil type with rectangular finned tube during freezing process (직사각형 휜이 부착된 관외착빙형 빙축열조에서 응고과정시 열전달 특성에 관한 연구)

  • Kwon, H.Y.;Koh, J.Y.;Jeong, B.Y.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.61-67
    • /
    • 2000
  • The purpose of this study is to improve heat transfer by attaching rectangular fins to tube. Experiments were carried out under the following conditions - Aspect ratio$(W_f/R_f)$ is 0.7, 1.2 and 1.8. Temperature conversion between high and low positions of water in the thermal storage appeared because maximum density point of water is about $4^{\circ}C$ and inlet direction of working fluid influenced conductive heat transfer Compared with the unfinned tube(bare tube), the rectangular tube increased the ice thermal storage energy and the ice thermal storage energy was increased as aspect ratio was increased.

  • PDF

Effect of the ice pack treatment in the corrugated box for improving the storage quality of the oriental melon (Cucumis melo var. makuwa) at high temperature conditions during summer (여름철 고온 환경 조건에서 참외(Cucumis melo var. makuwa)의 저장 중 선도유지를 위한 아이스 팩 처리 포장 박스 적용 연구)

  • Choi, Woo Suk;Chung, Dae-Sung;Lee, Youn Suk
    • Food Science and Preservation
    • /
    • v.21 no.1
    • /
    • pp.25-33
    • /
    • 2014
  • The effects of the ice pack and aluminum coated board in the corrugated boxes for maintaining the quality of fresh oriental melons (Cucumis melo var. makuwa) were investigated. The harvested oriental melons were stored at a temperature of $30^{\circ}C$ for 21 days after placing them in the corrugated boxes treated with control, including ice pack and aluminum coated board. The treatment with the ice pack and aluminum coated board was identified to have maintained the relative low temperature in the corrugated box against the high temperature from the environment. For the storage study of the oriental melon, the treatments with the ice pack and aluminum coated board reduced the respiration rate, the development of external color, and total weight loss. All treatments were also effective in maintaining the firmness and decreasing the decay ratio of the oriental melon as compared to those that were controlled. However, the value of total soluble solids regarding the fruit was insignificantly affected by the ice pack treatment. The results indicated that the application of the ice pack and aluminum coated board in the corrugated box played an important role in maintaining the quality of oriental melons during storage. The combination with the ice pack and aluminum coated board had more effective values on the storage qualities for oriental melons than that with the ice pack only. Based on the results of this study, the ice pack and aluminum coated board were the useful treatments for reducing the loss of quality of the fresh oriental melons in high temperature storage conditions.

Influence of the Supercooling Degree and Cooling Rate on a Continuous Ice Formation by a Supercooled Aqueous Solution in Flow Using a Plate Heat Exchanger (판형 열교환기를 이용한 과냉각수용액에서 유동과냉도 및 냉각속도가 연속제빙에 미치는 영향)

  • Lee, Dong-Gyu;Peck, Jong-Hyeon;Hong, Hi-Ki;Kang, Chae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.647-653
    • /
    • 2007
  • In dynamic ice storage system(DISS), ice slurry is formed not only from solution freezing by mechanical removing parts but also supercooled solution. However, in order to perform continuous ice formation in the system without mechanical moving parts, supercooled aqueous solution should be formed stable through cooling heat exchanger and be dissolved uniformly in storage tank. In previous study, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

Effect of Preservative, Ever-Fresh, on Fish and Shrimp Freshness during Ice Storage (선도유지제(鮮度維持劑)(Ever-Fresh) 처리(處理)가 붕장어 학꽁치 및 새우의 선도(鮮度) 유지(維持)에 미치는 효과(效果))

  • Lee, Eung-Ho;Kang, Hoon-I;Kim, Jung-Gun;Yang, Syung-Taek;Pyeun, Jae-Hyeung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.2 no.1
    • /
    • pp.49-54
    • /
    • 1973
  • In this paper, the effect of Ever-Fresh, a kind of preservatives for fish and shellfish, on fish and shrimp during ice storage were investigated. The results are as follows: 1. K value representing the ratio of optical densities of inosine and hypoxanthine fraction and total nucleotide fraction at 250nm could be useful as an index to measure the freshness of fish and shrimp during ice storage. 2. Volatile basic nitrogen could be also useful as an index to measure the freshness of shrimp during ice storage. 3. Ever-Fresh treatment of conger eel, half-beak, and shrimp appeared effective on keeping freshness during the early stage of ice storage. 4. Ever-Fresh treated shrimp showed lower thiobarbituric acid value as compared with the control during the early stage of ice storage.

  • PDF

Experimental Study on The Running Characteristics of Showcase Using Cold Storage System (과냉각 축냉시스템을 적용한 쇼케이스의 운전 특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.22-28
    • /
    • 2012
  • The purpose of this study was to show how tomaintain high efficiency and to use reasonably when being applied the cold-heat storage systems to the showcase. An experimental study was performed to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that of the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. Using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using the stored cold-heat after being discharged from the air cooling condenser during the day time. Through the experiments, the load transfer rate for the showcase using inverter and ice storage was estimated about 30.0%. And showed that the total power consumption of the showcase with inverter could be reduced about 37% than that of the showcase without inverter.