• 제목/요약/키워드: iPROVE

검색결과 813건 처리시간 0.027초

22.9kV 배전선로 적용을 위한 DVR의 새로운 외란검출 기법 및 제어시스템 설계 (The New Voltage Event Detection Method and Control System Design for DVR Applied to 22.9kV Distribution System)

  • 김희중;정용호;권기현;박태범;문전일;전영수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권1호
    • /
    • pp.7-12
    • /
    • 2006
  • This paper proposes the new voltage event detection method using the weight factor of neural network and describes control system design for the DVR(Dynamic Voltage Restorer) consisted of a rectifier and series inverter applied to 22.9kV distribution system. As this method can express the fault level of each phase, we expect the proposed method can make up for disadvantage of synchronous detection method. Also, in this paper, the control system was designed using double deadbeat controller, As it has an inner current control loop and an outer voltage control loop, we can easily limit the current level during the transient intervals by using the current control loop. Simulation and experiment are performed to prove the analysis of the voltage event detection method and double deadbeat controller.

Experimental work on seismic behavior of various types of masonry infilled RC frames

  • Misir, I. Serkan;Ozcelik, Ozgur;Girgin, Sadik Can;Kahraman, Serap
    • Structural Engineering and Mechanics
    • /
    • 제44권6호
    • /
    • pp.763-774
    • /
    • 2012
  • Reinforced concrete frame structures with masonry infill walls constitute the significant portion of the building stock in Turkey. Therefore it is very important to understand the behavior of masonry infill frame structures under earthquake loads. This study presents an experimental work performed on reinforced concrete (RC) frames with different types of masonry infills, namely standard and locked bricks. Earthquake effects are induced on the RC frames by quasi-static tests. Results obtained from different frames are compared with each other through various stiffness, strength, and energy related parameters. It is shown that locked bricks may prove useful in decreasing the problems related to horizontal and vertical irregularities defined in building codes. Moreover tests show that locked brick infills maintain their integrity up to very high drift levels, showing that they may have a potential in reducing injuries and fatalities related to falling hazards during severe ground shakings.

곡률에 근거한 형상 측정기술 개발 (Development of Profilometry based on a Curvature Measurement)

  • 김병창
    • 한국광학회지
    • /
    • 제18권2호
    • /
    • pp.130-134
    • /
    • 2007
  • 광역의 자유곡면 형상을 나노미터 정밀도로 측정하기 위한 새로운 형상 측정법으로서 곡률에 근거한 형상 측정법을 제안한다. 곡률 형상 측정기는 피측정물을 일정간격으로 스캔하는 간섭계로써 각 국부영역의 형상으로부터 곡률을 획득하여, 이로부터 전 영역의 형상을 복원한다. 제안된 곡률 형상 측정기는 비구면 형상 측정을 위해 개발된 보상 광학계(Null optics)나 국부영역의 형상을 측정하고 결합하는 subaperture-slicking 법에 비해 측정 장비로부터 발생하는 시스템 오차를 근본적으로 제거하는 특징을 가진다. $80mm\times80mm\times25mm$ 작동구간을 갖는 Stewart Platform과 상용 트와이만 그린 간섭계를 이용하여 곡률간섭계를 구성하였으며, 자유곡면의 형상측정을 위한 첫 단계로서 잘 알려진 구면형상을 측정하고, 기존 장비의 측정값과 비교한 결과 32 mm영역에서 최대 56 nm의 차를 보임을 확인하였다.

전자거래에서 전자기록 송수신 시기 및 장소의 해석과 적용 (Interpretation and Application of Time and Place of Dispatch and Receipt of Electronic Records in Electronic Transactions)

  • 강원진;이창숙
    • 통상정보연구
    • /
    • 제9권3호
    • /
    • pp.287-304
    • /
    • 2007
  • Determination of the time and place of dispatch and receipt of electronic messages is an important element of the operation of many rules of law, particularly the timing of formation of the contract. In this paper, I reviewed interpretation and application of time and place of dispatch and receipt of electronic records in electronic transactions under the UNCITRAL(United Nations Commission on International Trade Law) Model Law on Electronic Commerce, USA Uniform Electronic Transactions Act and Korea Electronic Transactions Act. Time of dispatch and time of receipt are effective when received. The sender has the burden to prove that the electronic record is sent successfully to the information process system of the recipient. Therefore, to safety electronic transactions, the sender needs to request a confirm notice for receipt to the recipient when the electronic record is sent like the provisions of UNCITRAL Model Law on Electronic Commerce and Korea Electronic Transactions Act. By requesting the above, the sender is able to take precautionary measures for damage according to the failure of dispatch and receipt of the electronic records.

  • PDF

안면비대칭 환자의 악교정술 후 안면비대칭의 개선에 따른 악관절장애 증상의 변화 (CHANGES OF TEMPOROMANDIULAR JOINT SYMPTOMS AFTER ORTHOGNATHIC SURGERY IN THE ASYMMETRIC PROGNATHISM PATIENTS)

  • 김영삼;류동목
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권5호
    • /
    • pp.518-523
    • /
    • 2007
  • Purpose: The purpose of this study is to prove that orthognatic surgery on asymmetric prognathism patients improve the temporomandibular dysfunction. Materials and methods: All 30 patients underwent mandibular setback with B-SSRO including 22 patients Le Fort I surgery in KyungHee medical center. Preoperative and postoperative PA cephalograms & transcranial radiographs were measured midline deviation in Mx and Mn, occlusal canting change, condyle position, the temporomandibular dysfunction were checked before surgery, within 1 month after surgery, $3{\sim}6$ months, 12-24 months after surgery respectively. Results: The temporomandibular dysfunction were relieved after surgery in 17 patients of 25 patients. Conclusion: Orthognatic surgery may benefit the temporomandibular joint dysfunction in facial asymmetry patients by obtaining a postoperative stable occlusion and better physiologic neuromuscular function. Specially impovement of occlusal canting may reduce condyle displacement of midline deviation side and the temporomandibular joint dysfunction.

Structural system simulation and control via NN based fuzzy model

  • Tsai, Pei-Wei;Hayat, T.;Ahmad, B.;Chen, Cheng-Wu
    • Structural Engineering and Mechanics
    • /
    • 제56권3호
    • /
    • pp.385-407
    • /
    • 2015
  • This paper deals with the problem of the global stabilization for a class of tension leg platform (TLP) nonlinear control systems. It is well known that, in general, the global asymptotic stability of the TLP subsystems does not imply the global asymptotic stability of the composite closed-loop system. Finding system parameters for stabilizing the control system is also an issue need to be concerned. In this paper, we give additional sufficient conditions for the global stabilization of a TLP nonlinear system. In particular, we consider a class of NN based Takagi-Sugeno (TS) fuzzy TLP systems. Using the so-called parallel distributed compensation (PDC) controller, we prove that this class of systems can be globally asymptotically stable. The proper design of system parameters are found by a swarm intelligence algorithm called Evolved Bat Algorithm (EBA). An illustrative example is given to show the applicability of the main result.

DEVELOPMENT OF ROLLOVER CRITERIA BASED ON SIMPLE PHYSICAL MODEL OF ROLLOVER EVENT

  • KIM M. H.;OH J. H.;LEE J. H.;JEON M. C.
    • International Journal of Automotive Technology
    • /
    • 제7권1호
    • /
    • pp.51-59
    • /
    • 2006
  • The high potential for injury involved in rollover accidents warrants the development of a system to protect passengers against such events. To effectively implement such a protection system, it is first necessary to determine rollover criteria (i.e., real time states which indicate the occurrence of rollover events). In this paper, several rollover criteria have been developed based on simplified physical models. Such accidents are first classified into two types, untripped and tripped, according to the main cause that initiates the rollover. Characteristics of these rollover situations are identified by applying appropriate principles of dynamics to corresponding simplified physical models. Two main rollover criteria, Rotational Kinetic Energy (RKE) and Initial Kinetic Energy (IKE), are then introduced based on these characteristics. ADAMS/View simulations have been performed to verify the feasibility of the introduced rollover criteria. ADAMS/Car simulations have also been conducted to get more realistic rollover data with a complete vehicle model. Results of these experiments reveal that our established criteria prove useful for predicting whether actual rollover occurs or not.

ACTIVATED CARBON CANISTER PERFORMANCE FOR A SPARK IGNITION ENGINE

  • CHOI G. H.;CHOI K. S.;CHUNG Y. J.;KIM I. M.;DIBBLE R. W.;HAN S. B.
    • International Journal of Automotive Technology
    • /
    • 제7권1호
    • /
    • pp.9-15
    • /
    • 2006
  • Prediction of the performance of a carbon canister in vehicle evaporative emission control system has become an important aspect of overall fuel system development and design. A vehicle's evaporative emission control system is continuously working, even when the vehicle is not running, due to generation of vapors from the fuel tank during ambient temperature variations. Evaporative emissions from gasoline powered vehicles continue to be a major concern. The objective of this paper is to clarity the flow characteristics and other such fundamental data for the canister during loading and purging are needed, and this data will prove valuable in the development of the canister. This paper is to evaluate the relationship between carbon canister condition and engine performance during engine operation, and the effects of evaporative emissions on the engine performance were investigated.

Genesis of Researches on Surges in Pumping Systems in Japan

  • Yamaguchi, Nobuyuki;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.17-27
    • /
    • 2016
  • Researches on the mechanism of surging and the surge behaviors in the systems of pumps, or fans or compressors, and the effects of flow-paths had been initiated and had made a great progress in Japan in the decades from the nineteen-forties to the nineteen-sixties. In 1947, the essential cause of the surges, i.e., self-excited oscillation nature of the flow-system, was discovered analytically by Professor Sumiji Fujii of Tokyo University, and most of the characteristic behaviors of the phenomena had been explained clearly. Successive studies by many other Japanese researchers continued to prove experimentally the mechanism, to extend the analytical studies, and to attempt preventing surge occurrence, etc. in the following two decades. The historical information on the early surge studies could be helpful to some concerned people. At the same time, the basic and plain ways of discussions and reasoning about the phenomena in the pioneering researches could give us much to be learned even in the present time of high-power computing systems. Regrettably, many of the original research works have been published only in Japanese. The present review introduces very briefly the situations in memories of the pioneering researchers and engineers.

지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석 (Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.